SERVICE CATALOGUE
www.solumconsultantsltd.com
SOLUM CONSULTANTS LABORATORY SERVICES
Solum Consultants Ltd is specialized in geotechnical engineering and soils and aggregates testing.
The company was originally established in 2003 operating under the name of Solum Testing performing
soils and aggregates testing using ASTM and AASHTO procedures.
In 2006 the company was transferred to Saad A.M. Farag Ph.D., P.Eng. Mr. Farag is a geotechnical and structural engineer with over 20 years of experience in geotechnical engineering and material testing. Significant developments and improvements have been steadily achieved in all aspects of procedures leading to distinguish quality production. Solum Consultants Ltd. possesses the capacity to simultaneously run twenty-eight consolidation tests (ASTM D2435), thirty Tri-axial shear tests with pore water pressure measurements (ASTM D4767), five fully computerized Direct Shear test (ASTM D3080), and thirty-seven Hydraulic Conductivity Tests (permeability) (ASTM D5084). These developments enable Solum Consultants to effectively and efficiently handle large projects where turnaround time is of great concern. Recently, pneumatic conductivity or air permeability tests have been developed using either rigid-wall or flexible-wall methods, ASTM D6539, as well as thermal conductivity/resistively test, ASTM D5334.
Why Choose Solum for Your Geotechnical Laboratory Testing Needs?
1. Solum uses industry accepted ASTM (American Society of Testing and Materials) as well as
Corps of Engineers procedures for laboratory testing.
2. Solum offers quick turn around times on testing. Ninety-percent of our testing projects are
completed in less than 6 business days; it is not uncommon to transmit preliminary results to
our clients located at the construction site immediately after testing is completed.
3. Competitive prices.
4. Our testing results are well organized and clearly presented. Please refer to Appendix II for a
sample laboratory testing report.
5. Our testing results are transmitted electronically via email. We can also deliver results by
conventional means (ie. mail, fax) if desired.
6. Solum will pay for local sample shipping for testing order more than $100.00. For out of town
sample shipping, Solum will reimburse shipping cost up to 10% of the testing order, if
requested.
The following package will assist in determining what testing services Solum provides or what services
can be arranged. If you do not see a listing of the test you require, please contact us. All samples and
data are handled in the strictest confidentiality.
CONTACT INFORMATION
Solum Consultants Ltd. Saad A.M. Farag Principal
9, 3620-29 Street, N.E. Kathy Tcao Laboratory Manager
Calgary, Alberta, Canada Email: [email protected]
T1Y 5Z8 Tel: (403) 250-3035 Cell: (403) 619-7250
Fax: (403) 250-3021
Web: www.solumconsultantsltd.com
WATER (MOISTURE) CONTENT– ASTM D2216
LABORATORY PROCEDURE USED: ASTM D2216 - Standard Test Methods for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass RESULTS GIVEN: Water (Moisture) Content in Percent (%) by Mass REQUIRED SAMPLE SIZE FOR TESTING:
Maximum Particle Size Minimum Test Sample Size, g 4.75 mm (No.4) or smaller 150 9.5 mm (3/8 in.) 750 19.0 mm (3/4 in.) 1500 MAXIMUM PARTICLE SIZE: The smallest sieve through which 100 percent of the soil-aggregate
sample particles pass.
ATTERBERG LIMITS – ASTM D4318
LABORATORY PROCEDURE USED: ASTM D4318 - Standard Test Methods for Liquid Limit, Plastic
Limit, and Plasticity Index of Soils. Method A – Multipoint Liquid Limit
RESULTS GIVEN:
1.) Liquid Limit (LL), Plastic Limit (PL), Plasticity Index (PI) and Flow Curve.
2.) Soil classification group symbol per plasticity chart (ASTM D2487). Please refer to page 4 for
soil classification group symbol descriptions. If the soil is “nonplastic” (ie. sands or silts) the
liquid limit, plastic limit, plasticity index, flow curve and group symbol of the fine fraction cannot
be determined.
* Refer to Appendix II for a sample laboratory testing report.
REQUIRED SAMPLE SIZE FOR TESTING: 450g
BACKGROUND INFO:
When water is added to a dry soil, each particle is covered with a film of water. If the addition of water
is continued, the thickness of the water film on a particle increases. The thicker the water films around
the particle the easier for the particles to move past each other. Depending on the amount of water in
the soil, a fine-grained soil can exist in any of several states:
Liquid Limit (LL): The boundary between the semi-liquid and plastic states; measured in percent water
(moisture) content.
Plastic Limit (PL): The boundary between the plastic and semi-solid states; measured in percent water
(moisture) content.
Shrinkage Limit (SL): The boundary between the semi-solid and solid states; measured in percent water
(moisture) content.
0
10
20
30
40
50
60
0 10 20 30 40 50 60 70 80 90 100 110
Liquid Limit (LL)
Pla
stic
ity
Ind
ex(P
I)
“A” LINE“U” LINE
Equation of U-Line. Vertical at LL=16 to PI=7, then PI=0.9(LL-8)
Equation of A-Line. Horizontal at PI=4 to LL=25.5, then PI=0.73(LL-20)
CL or OL
CH or OH
MH or OH
ML or OL
CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES (UNIFIED SOIL
CLASSIFICATION SYSTEM) – ASTM D2487
LABORATORY PROCEDURE USED: ASTM D2487 - Standard Practice for Classification of Soils for
Engineering Purposes (Unified Soil Classification System)
RESULTS GIVEN:
1.) Group Symbol (please refer to page 4 for descriptions of group symbols);
2.) Group Name, upon request since some organizations don’t recognize the group name
descriptions (ie. fat or lean clay) as per ASTM D2487.
NOTE: Solum determines the group symbol and group name (upon request) free of charge if the
required testing, as stated below, is completed.
REQUIRED TESTING:
Atterberg Limits – ASTM D4318 and one of the following:
1.) Particle-Size Analysis of Soils (Full Gradation) – ASTM D422; or,
2.) Greater Than No. 200 (0.075 mm) Sieve Analysis – ASTM C136
BACKGROUND INFO:
PLASTICITY CHART
FOR CLASSIFICATION OF FINE-GRAINED SOILS AND FINE-GRAINED FRACTION OF COARSE-
GRAINED SOILS
Inorganic Silts and Very Fine Sands, Rock Flour, Silty Sands of Slight Plasticity
HIGHLY ORGANIC SOILS
GRAVELS
More than 50% of coarse
fraction retained on No. 4 (4.75
mm) sieveCOARSE-GRAINED
SOILS
More than 50% retained on
No. 200 (0.075 mm) sieve
SANDS
More than 50% of coarse
fraction passing No. 4 (4.75 mm)
sieve
CLEAN GRAVELSLess than 5%
fines
GRAVELS WITH FINES
Greater than 12% fines
CLEAN SANDS
Less than 5% fines
SANDS WITH FINES
Greater than 12% fines
INORGANIC
ORGANIC
INORGANIC
ORGANIC
MH
OL
CL
ML
SC
SM
SP
SW
GC
GM
GP
GW
PT
OH
CH
FINE-GRAINED
SOILS
50% or more passes the
No. 200 (0.075 mm) sieve
SILTS AND
CLAYS
Liquid Limit less than 50
SILTS AND
CLAYS
Liquid Limit greater than 50
Organic Silts and Organic Silty Clays of Low Plasticity
Silty Sands, Sand-Silt Mixtures, > 12% Fines *
Poorly-graded Sands, Gravelly Sands, < 5% Fines *
Well-graded Sands, Gravelly Sands, < 5% Fines *
Clayey Gravels, Gravel-Sand-Clay Mixtures, > 12% Fines *
Silty Gravels, Gravel-Sand-Silt Mixtures, > 12% Fines *
Well-graded Gravels, Gravel-Sand Mixtures, < 5% Fines *
Peat, Humus and Other Highly Organic Soils
Inorganic Silts, Micaceous or Diatomaceous Fine Sand or Silty Soils
Organic Clays of High Plasticity
Inorganic Clays of High Plasticity, Fat Clays
Inorganic Clays of Low to Medium Plasticity, Gravelly Clays, Sandy Clays, Silty Clays, Lean Clays
Clayey Sands, Sand-Clay Mixtures, > 12% Fines *
Poorly-graded Gravels, Gravel-Sand Mixtures, < 5% Fines *
UNIFIED SOIL CLASSIFICATION SYSTEM
UNIFIED SOIL CLASSIFICATION SYSTEM (Continued)
UNIFIED SOIL CLASSIFICATION SYSTEM (USCS)
MILLIMETERS INCHES SIEVE SIZES
BOULDERS > 300 > 12 ---
COBBLES 300 - 75 12 - 3 ---
COARSE 75 - 19 3.0 - 0.75 3.0" - 3/4" GRAVEL
FINE 19 - 4.75 0.75 - 0.19 3/4" - NO. 4
COARSE 4.75 - 2.00 0.19 - 0.08 NO. 4 - NO. 10
MEDIUM 2.00 - 0.425 0.08 - 0.017 NO. 10 - NO.40 SAND
FINE 0.425 - 0.075 0.017 - 0.003 NO. 40 - NO. 200
SILTS 0.075 - 0.005 0.003 – 0.0002
FINES
CLAYS < 0.005 < 0.0002
HYDROMETER TEST (INCLUDED IN ASTM D422 –
FULL GRADATION)
PARTICLE-SIZE ANALYSIS (FULL GRADATION) – ASTM D422
LABORATORY PROCEDURE USED: ASTM D422 - Standard Test Method for Particle-Size Analysis of
Soils (Includes Hydrometer Test)
RESULTS GIVEN:
1.) Percent of clay, silt, sand, gravel and cobble size;
2.) Particle-size distribution curve;
3.) Detailed table of the particle-size distribution curve plot data including sieve sizes, particle-
sizes in millimetres and a percent finer column
* Refer to Appendix II for a sample laboratory testing report.
REQUIRED SAMPLE SIZE FOR TESTING:
Nominal Maximum Size Minimum Test Sample Size, kg (lbs) 4.75 mm (No. 4) or smaller 0.5(1) 9.5 mm (3/8 in.) 1(2) 12.5 mm (1/2 in.) 2(4) 19.0 mm (3/4 in.) 5(11) 25.0 mm (1 in.) 10(22) 37.5 mm (1.5 in.) 15(33) NOMINAL MAXIMUM SIZE: The largest sieve that retains some of the soil-aggregate particles but generally not more than 10 percent by weight.
GREATER THAN NO. 200 (0.075 mm) SIEVE ANALYSIS – ASTM C136 LABORATORY PROCEDURE USED: ASTM C136 - Standard Test Method for Sieve Analysis of Fine
and Coarse Aggregates
RESULTS GIVEN:
1.) Percent of fines (less than No. 200 sieve), sand, gravel and cobble size;
2.) Particle-size distribution curve;
3.) Detailed table of the particle-size distribution curve plot data including sieve sizes, particle-sizes
in millimetres and a percent finer column.
REQUIRED SAMPLE SIZE FOR TESTING:
Nominal Maximum Size Minimum Test Sample Size, kg (lbs) 4.75 mm (No. 4) or smaller 0.5(1) 9.5 mm (3/8 in.) 1(2) 12.5 mm (1/2 in.) 2(4) 19.0 mm (3/4 in.) 5(11) 25.0 mm (1 in.) 10(22) 37.5 mm (1.5 in.) 15(33) NOMINAL MAXIMUM SIZE: The largest sieve that retains some of the soil-aggregate particles but generally not more than 10 percent by weight.
MATERIALS FINER THAN NO. 200 (0.075 mm) SIEVE – ASTM C117
LABORATORY PROCEDURE USED: ASTM C117 - Standard Test Method for Materials Finer than 75-
µm (No. 200) Sieve in Mineral Aggregates by Washing
RESULTS GIVEN: Percentage of material finer than the 0.075mm (No. 200) sieve.
REQUIRED SAMPLE SIZE FOR TESTING:
Nominal Maximum Size Minimum Dry Mass, g 4.75 mm (No. 4) or smaller 300 9.5 mm (3/8 in.) 1000 19.0 mm (3/4 in.) 2500 37.5 mm (1.5 in.) 5000 NOMINAL MAXIMUM SIZE: The largest sieve that retains some of the soil-aggregate particles but generally not more than 10 percent by weight. BACKGROUND INFO: Anything finer than the 0.075 mm (No. 200) sieve are considered to be fines
(Fines: silt, clay, rockflour); therefore, the percentage that you are given is percentage of fines in the
sample. Please see the Unified Soil Classification System on page 5 for more details.
STANDARD PROCTOR (COMPACTION CHARACTERISTICS OF SOIL) –
ASTM D698
LABORATORY PROCEDURE USED: ASTM D698 - Standard Test Methods for Laboratory Compaction
Characteristics of Soil Using Standard Effort (600kN-m/m3)
RESULTS GIVEN:
1.) Maximum Dry Density, kg/m3;
2.) Optimum Water Content, %;
3.) Dry Density vs. Water Content Plot Curve;
4.) Oversize Particles Correction for both the Maximum Dry Density and Optimum Water Content
per ASTM D4718. Please note, the oversize correction will only be given if the sample yields
5% or more of oversize particles.
* Refer to Appendix II for a sample laboratory testing report.
REQUIRED SAMPLE SIZE FOR TESTING: 20 kg (One-5 gallon pail)
NOTE: If client does not specify the procedure (A, B, or C), the choice will be based on the material
gradation. Procedure A will be used if 20% or less by weight of the material is retained on the No. 4
(4.75 mm) sieve. Procedure B will be used if more than 20% by weight of the material is retained on the
No. 4 (4.75 mm) sieve and 20% or less by weight of the material is retained on the 3/8 in. (9.5 mm)
sieve. Procedure C will be used if more than 20% by weight of the material is retained on the 3/8 in.
(9.5 mm) sieve and less than 30% by weight of the material is retained on the 3/4 in. (19.0 mm) sieve.
MODIFIED PROCTOR (COMPACTION CHARACTERISTICS OF SOIL) –
ASTM D1557
LABORATORY PROCEDURE USED: ASTM D1557 – Standard Test Methods for Laboratory
Compaction Characteristics of Soil Using Modified Effort (2,700kN-m/m3)
RESULTS GIVEN:
1.) Maximum Dry Density, kg/m3;
2.) Optimum Water Content, %;
3.) Dry Density vs. Water Content Plot Curve;
4.) Oversize Particles Correction for both the Maximum Dry Density and Optimum Water Content
per ASTM D4718. Please note, the oversize correction will only be given if the sample yields
5% or more of oversize particles.
REQUIRED SAMPLE SIZE FOR TESTING: 20-30 kg (One full 5 gallon pail)
NOTE: If client does not specify the procedure (A, B, or C), the choice will be based on the material
gradation. Procedure A will be used if 20% or less by weight of the material is retained on the No. 4
(4.75 mm) sieve. Procedure B will be used if more than 20% by weight of the material is retained on the
No. 4 (4.75 mm) sieve and 20% or less by weight of the material is retained on the 3/8 in. (9.5 mm)
sieve. Procedure C will be used if more than 20% by weight of the material is retained on the 3/8 in.
(9.5 mm) sieve and less than 30% by weight of the material is retained on the 3/4 in. (19.0 mm) sieve.
HYDRAULIC CONDUCTIVITY (PERMEABILITY) OF FINE GRAINED SOILS
(CONSTANT HEAD) – ASTM D5084
LABORATORY PROCEDURE USED: ASTM D5084 - Standard Test Method for Measurement of
Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter
RESULTS GIVEN:
1.) Hydraulic Conductivity (Permeability) at 20 degrees Celsius, k20, in cm/sec;
2.) Dry Density, kg/m3;
3.) Hydraulic Gradient;
4.) Water (Moisture) Content.
* Refer to Appendix II for a sample laboratory testing report.
BACKGROUND INFO: Hydraulic Conductivity is also known as "Coefficient of Permeability". ASTM
D5084 is the standard test method to determine the hydraulic conductivity (permeability) of fine-grained
soils where precise measurements are required.
REQUIRED SAMPLE SIZE FOR TESTING:
If the permeablility of an undisturbed sample is required, use a 3 inch o.d. Shelby tube to collect the
sample. Shelby tubes can be purchased from Solum or any drilling rig service provider. Solum also
offers Shelby tube extractors for surface samples free of charge; shipping is extra.
Solum will remould disturbed soil samples to a density and moisture content as specified by the client. If
the client has the remoulding specs (ie. standard proctor results of the soil) then 2000g of soil is
sufficient. If soil has particles greater than 4.75 mm (No. 4) then 3000g is required. If there is no proctor
data for the disturbed sample then the standard proctor test must be performed. See standard proctor –
ASTM D698 for required sample size.
HYDRAULIC CONDUCTIVITY (PERMEABILITY) OF FINE GRAINED SOILS –
FALLING HEAD METHOD
LABORATORY PROCEDURE USED: CORPS OF ENG. EM1110-2-1906, APPENDIX VII -
Measurement of Hydraulic Conductivity (Permeability) of Fine Grained Soils – Falling Head
RESULTS GIVEN:
1.) Hydraulic Conductivity (Permeability) at 20 degrees Celsius, k20, in cm/sec;
2.) Dry density (kg/m3) or percent (%) of maximum dry density.
REQUIRED SAMPLE SIZE FOR TESTING:
If the permeablility of an undisturbed sample is required, use a 3 inch o.d. Shelby tube to collect the
sample. Shelby tubes can be purchased from Solum or any drilling rig service provider. Solum also
offers Shelby tube extractors for surface samples free of charge; shipping is extra.
Solum will remould disturbed soil samples to a density and moisture content as specified by the client. If
the client has the remoulding specs (ie. standard proctor results of the soil) then 2000g of soil is
sufficient. If soil has particles greater than 4.75 mm (No. 4) then 3000g is required. If there is no proctor
data for the disturbed sample then the standard proctor test must be performed. See standard proctor –
ASTM D698 for required sample size.
BACKGROUND INFO: Hydraulic Conductivity is also known as "Coefficient of Permeability". The
falling head permeability test is good indicator of the permeability of the soil but please note, this test is
not ASTM approved. If precise measurements are required the use of standard test method ASTM
D5084 (Constant Head) is recommended.
HYDRAULIC CONDUCTIVITY (PERMEABILITY) OF GRANULAR SOILS –
ASTM D2434
LABORATORY PROCEDURE USED: ASTM D2434 – Standard Test Method for Permeability of
Granular Soils (Constant Head)
RESULTS GIVEN:
1.) Hydraulic Conductivity (Permeability) at 20 degrees Celsius, k20, in cm/sec;
2.) Dry Unit Weight, kg/m3;
NOTE: In order to limit consolidation influences during testing, this method is limited to disturbed
granular soils containing not more than 10% soil passing the No. 200 (0.075 mm) sieve.
REQUIRED SAMPLE SIZE FOR TESTING: 20 kg (Three-quarter full 5 gallon pail)
BACKGROUND INFO: This constant head method is used to measure the hydraulic conductivity
(permeability) of granular soils that may be used as embankments or when used as base courses under
roads.
THERMAL CONDUCTIVITY /RESISTIVITY OF SOILS – ASTM D5334
LABORATORY PROCEDURES USED: ASTM D5334 - Standard Test Method for Determine the
Thermal Conductivity / Resistivity of Soils ( ASTM D5334 )
RESULTS GIVEN: Thermal Resistivity, in K-cm/watt.
FACT: ASTM D5334 is the standard test method to determine the thermal conductivity/resistivity for
disturbed or undisturbed soils.
REQUIRED SAMPLE SIZE FOR TESTING:
If the resistivity of an undisturbed sample is required, use a 3 inch O/D Shelby tube to collect the
sample.
Solum will remould disturbed soil samples to a density and moisture contents as specified by the client.
If the client has the remoulding specs (ie. standard proctor results of the soil) then 2000g/point of soil is
sufficient. If soil has particles greater than 4.75 mm (No. 4) then 3000g is required. If there is no proctor
data for the disturbed sample then the standard proctor test needs to be performed.
TOTAL POROSITY, AIR-FILLED POROSITY - CORPS OF ENG. EM1110-2-1906,
APPENDIX II
LABORATORY PROCEDURE USED: CORPS OF ENG. EM1110-2-1906, APPENDIX II, Total Porosity
and Air-Filled Porosity
RESULTS GIVEN:
1.) Total Porosity, %;
2.) Air-Filled Porosity, %;
3.) Water (Moisture) Content, %.
REQUIRED SAMPLE SIZE FOR TESTING:
Undisturbed samples are collected using thin walled Shelby tubes. Samples should be undisturbed but
Solum can remould disturbed samples to densities and moisture contents as specified by client.
NOTE: This test method is not suitable for soils that contain significant amounts of particles coarser
than the 4.75mm (No. 4) sieve, organic soils or soils of low plasticity which will not be readily retained in
the cylinder.
BULK DENSITY (INSITU DENSITY) – ASTM D2937
LABORATORY PROCEDURE USED: ASTM D2937 - Standard Test Method for Density of Soil in Place
by the Drive-Cylinder Method
RESULTS GIVEN:
1.) Dry Bulk Density, kg/m3;
2.) Water (Moisture) Content, %.
REQUIRED SAMPLE SIZE FOR TESTING:
Undisturbed samples are collected using thin walled Shelby tubes.
REMARKS: This test method is not suitable for soils that contain significant amounts of particles
coarser than the 4.75mm (No. 4) sieve. This test method is also not suitable for organic soils or soils of
low plasticity which will not be readily retained in the cylinder.
SPECIFIC GRAVITY OF SOILS – ASTM D854
LABORATORY PROCEDURE USED: ASTM D854 - Standard Test Methods for Specific Gravity of Soil
Solids by Water Pycnometer
RESULTS GIVEN: Specific Gravity
REQUIRED SAMPLE SIZE FOR TESTING: 750g of Soil
REMARKS: This test method is used to determine the specific gravity of soils that pass the 4.75 mm
(No. 4) sieve.
ONE-DIMENSIONAL CONSOLIDATION PROPERTIES OF SOIL –
ASTM D2435
LABORATORY PROCEDURE USED: ASTM D2435 - Standard Test Methods for One-Dimensional
Consolidation Properties of Soils Using Incremental Loading
RESULTS GIVEN:
1.) Coefficient of Consolidation;
2.) Time-Deformation Curve
REQUIRED SAMPLE SIZE FOR TESTING:
Undisturbed samples (Shelby tubes) or disturbed samples may be remoulded to a density and moisture
condition stipulated by the agency requesting the test. Sample size: 600-1000g
FALL CONE SHEAR TEST FOR DISTURBED FINE-GRAINED CLAYEY SOIL –
ROCTEST® PROCEDURE
LABORATORY PROCEDURE USED: Fall Cone Manufacturer (ROCTEST ®) Procedure
RESULTS GIVEN:
1.) Shear Strength (t/m2) versus Water (Moisture) Content Plot.
* Refer to Appendix II for a sample laboratory testing report.
REQUIRED SAMPLE SIZE FOR TESTING: 1000-1500g of disturbed fine-grained clayey soils.
BACKGROUND INFO: The fall cone test is a fast and inexpensive way to determine the shear strength
of a soil when the water content is in the range of the plastic limit and the liquid limit.
LABORATORY MINIATURE VANE SHEAR TEST FOR SATURATED FINE-
GRAINED CLAYEY SOIL – ASTM D4648
LABORATORY PROCEDURE USED: ASTM D4648 - Standard Test Method for Laboratory Miniature
Vane Shear Test for Saturated Fine-Grained Clayey Soil
RESULTS GIVEN:
1.) Plot of undisturbed shear strength (kPa) and maximum torque (N-m).
2.) Plot of remoulded shear strength (kPa) and maximum torque (N-m).
3.) Rate of shear and time to failure
* Refer to Appendix II for a sample laboratory testing report.
REQUIRED SAMPLE SIZE FOR TESTING: (Fine-grained clayey soils only.)
1.) Undisturbed vane strength: Shelby tube sample;
2.) Machine remoulded vane strength: using above (1) failed undisturbed sample;
3.) Hand remoulded (compacted) vane strength: 2000-2500g of disturbed soil.
BACKGROUND INFO: Machine remoulded vane strength is obtained by rotating the vane rapidly
through a minimum of five to ten revolutions on the failed undisturbed specimen, similar to remoulded
field vane tests (ASTM D2573) and conducting a vane test 1 minute after the machine remoulding
process. Please note, machine remoulded shear strength is typically higher than the hand remoulded
shear strength.
DIRECT SHEAR TEST OF SOILS UNDER CONSOLIDATED DRAINED
CONDITIONS – ASTM D3080
LABORATORY PROCEDURE USED: ASTM D3080 - Standard Test Method for Direct Shear Test of
Soils Under Consolidated Drained Conditions
RESULTS GIVEN:
1.) Initial and final dry density; initial and final water content;
2.) Normal Stress, rate of deformation and shear displacement;
3.) Plot of log of time or square root of time versus deformation of those load increments where t50
(time to 50% consolidation) was determined;
4.) Plot of nominal shear stress versus percent relative lateral displacement.
NOTE: Three or more specimens are generally tested, each under a different normal load, to determine
the effects upon shear resistance and strength properties. Normal loads should be selected which
represent the field conditions being investigated.
REQUIRED SAMPLE SIZE FOR TESTING:
1.) Undisturbed samples are collected using thin walled Shelby tubes;
2.) Disturbed samples may be remoulded to a density and moisture condition stipulated by the
agency requesting the test; approximately 2000 g of soil is needed for remoulding of the test
specimen.
UNCONSOLIDATED UNDRAINED TRIAXIAL COMPRESSION TEST ON
COHESIVE SOILS – ASTM D2850
LABORATORY PROCEDURE USED: ASTM D2850 - Standard Test Method for Unconsolidated-
Undrained Triaxial Compression Test on Cohesive Soils.
RESULTS GIVEN:
1.) Specimen dry density, percent saturation, void ratio, and water content;
2.) Rate of axial strain, percent per minute; axial strain at failure, percent;
3.) Compressive strength and the values of the minor and major principal stresses at failure;
4.) Stress-strain curve;
5.) Failure sketch of specimen.
REQUIRED SAMPLE SIZE FOR TESTING:
1.) Undisturbed samples are collected using thin walled Shelby tubes;
2.) Disturbed samples may be remoulded to a density and moisture condition stipulated by the
agency requesting the test; approximately 2000 g of soil is needed for remoulding of the test
specimen.
CONSOLIDATED UNDRAINED TRIAXIAL COMPRESSION TEST ON COHESIVE
SOILS – ASTM D4767
LABORATORY PROCEDURE USED: ASTM D4767 – Standard Test Method for Consolidated
Undrained Triaxial Compression Test for Cohesive Soils
RESULTS GIVEN:
1.) Effective consolidation stress; time to 50% primary consolidation (t50);
2.) Specimen dry density, percent saturation after consolidation, void ratio, water content;
3.) The value of the principle stress difference (deviator stress) at failure and the values of the
effective minor and major principal stresses at failure;
4.) Axial strain at failure, percent; rate of strain, percent per minute;
5.) Principal stress difference and induced pore-water pressure versus axial strain curves;
6.) Failure sketch of specimen.
REQUIRED SAMPLE SIZE FOR TESTING:
1.) Undisturbed samples are collected using thin walled Shelby tubes
2.) Disturbed samples may be remoulded to a density and moisture condition stipulated by the
agency requesting the test; approximately 2000 g of soil is needed for remoulding of the test
specimen
LABORATORY RESEARCH AND DEVELOPMENT STUDIES
Solum has assisted major environmental engineering companies and Oil & Gas producers in the
following projects:
1.) Treatability Studies
2.) Remediation Engineering Studies
3.) Invertebrate Identification Studies
4.) Laboratory Sedimentation and Consolidation Tests on Tailing Ponds
5.) Geotechnical Engineering Characteristics of Tailing Ponds
6.) Solidification and Stabilization of Metal and Hydrocarbon Contaminated Soils
7.) Geotechnical Engineering Characteristics of Soil-Bentonite Mixtures due to Freeze-Thaw
Cycles
For more information please call the laboratory manager at (403) 250-3035 or email [email protected]
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
STANDARD LABORATORY TERMS AND CONDITIONS
1.0 Description of Services to be Performed by Solum Consultants Ltd. (Solum) Solum shall provide geotechnical and material laboratory testing services on samples in accordance with these terms and conditions and executed Laboratory Testing Request Forms. Solum shall perform its work in accordance with accepted laboratory standards and accepted standard operating procedures. Solum reserves the right to modify methods as necessary based upon experience and/or current scientific literature. If the Client requests a manner of analysis that varies from standard operating or recommended procedures, the Client shall not hold Solum responsible for the results. Such variations of analysis will be noted on the reports. Solum reserves the right to subcontract laboratory testing if a particular test cannot be performed by Solum. 2.0 Reports, Confidentiality and Third Parties Laboratory reports provided by Solum will be composed of a cover page, summary table of results, and other tables and figures if applicable. Reports will be e-mailed in PDF format to the individual(s) specified on the Laboratory Testing Request Forms. Laboratory reports may also be faxed or mailed to the Client upon request. Except as required by law, Solum shall not disclose testing results or reports to any party other than the Client, unless the Client, in writing, requests information to be provided to a third party. Solum shall abide by any additional confidentiality requirements requested by the Client provided that such requirements are provided to Solum at or before execution of the testing. Information provided by Solum is intended for Client use only. Any use by a third party, of reports or documents authored by Solum, or any reliance on or decisions made by a third party based on the findings described in said documents, are the sole responsibility of such third parities, and Solum accepts no responsibility of damages suffered by any third party as a result of decisions made or actions conducted. 3.0 Laboratory Testing Request Form (Chain of Custody) The laboratory testing request form must be completed by the Client and be accompanied with the samples. Testing will not commence until the laboratory testing request form has been completed. If requested by the Client, Solum shall provide a copy of the laboratory testing request form with the report. No persons other than the designated representatives for each Laboratory Testing Request Form are authorized to act regarding changes to the testing request form. Any changes or amendments of the laboratory testing request form must be in writing and be completed by the originator. 4.0 Acceptance, Contamination and Disposal of Samples Loss or damages to samples remains the responsibility of the Client until Solum representatives’ acceptance of samples by notation on the laboratory testing request form. As to any samples that are suspected of containing hazardous substances, the Client will specify the suspected or known substance and level of contamination. This information is to be stated on the laboratory testing request form and be accompanied with the samples before testing can commence. Solum may refuse acceptance of samples if it determines they present a risk to health and safety. Samples accepted by Solum shall remain the property and liability of the Client while in the custody of Solum. Solum will discard all non-contaminated samples after testing has been completed without a retention period at a fixed disposal charge, or if requested by the Client, samples may be returned to the Client at no cost to Solum. If requested by client, Solum will store samples provided the Client agrees to pay for the storage charge. Contaminated material may be returned/shipped to the Client at the Client’s expense or Solum will discard samples with disposal rates varying for samples containing higher levels of contamination, refer to price list. Soil samples requested to be stored will be stored inside the lab up to the expiration of storage period. Soil Samples will be discarded upon the expiration date of the storage period unless client requests either extending storage period or returning samples back to client at no cost to Solum. 5.0 Indemnification/Hold Harmless Solum shall protect, indemnify and save harmless Client, and its directors, officers, employees, agents, representatives, invitees and subcontractors, and at Client’s request, investigate and defend such entities form and against all claims, demands and causes of action, of every kind and character, without limitation, arising in favour of or made by third parties, on account of bodily injury, death or damage to or loss of their property resulting from any negligent act or wilful misconduct of Solum. The Client shall protect, indemnify and save harmless Solum, and its directors, officers, employees, agents, representatives, invitees and subcontractors, and at Solum’s request, investigate and defend such entities form and against all claims, demands and causes of action, of every kind and character, without limitation, arising in favour of or made by third parties, on account of bodily injury, death or damage to or loss of their property resulting from any negligent act or wilful misconduct of Client.
6.0 Limitation of Liability The total liability of Solum or its staff whether based in contract or tort, will be limited to the lesser of the fees paid or actual damages incurred by the Client. Solum will not be responsible for any consequential or indirect damages even if caused by negligence of Solum. Solum will only be liable for damages resulting form negligence of Solum. All claims by the Client shall be deemed relinquished if not made within one year after the testing date. No warranty is either expressed or implied, or intended by any agreement or by furnishing oral or written reports or findings. 7.0 Termination of Testing Work Order The Client may order work suspended or terminated upon seven days advance written notice. If work is suspended, Solum shall receive, upon resumption, an adjustment in the cost of services to compensate for additional costs incurred due to the interruption of services. Upon suspension or termination, Solum shall preserve samples provided that the Client agrees to pay the sample storage charge. 8.0 Pricing, Payments and Invoicing Invoices will be based on current Solum laboratory testing rates; rates may change without notice. Solum invoices shall be paid within thirty (30) days of receipt of the invoice. Amounts not paid when due shall bear interest at the rate of 18% per annum from the date due until the date of payment.
APPENDIX I
LABORATORY TESTING REQUEST FORM
PLEASE MAKE COPIES OF THIS FORM, COMPLETE WITH SAMPLE INFORMATION AND FAX TO SOLUM OR INCLUDE WITH SAMPLE(S). THE LABORATORY TESTING REQUEST FORM MAY
ALSO BE PRINTED FROM OUR WEBSITE: http://www.solumconsultantsltd.com/pdf/testingrequestform.pdf
9, 3620-29 Street, N.E.
Calgary, AB T1Y 5Z8
Tel.: (403) 250-3035
Fax: (403) 250-3021 SOLUM PROJECT# PAGE OF
COMPANY:
CONTACT:
ADDRESS:
PHONE: (OPTIONAL) (OPTIONAL)
FAX: (OPTIONAL) (OPTIONAL)
PROJECT #:
REGULAR (DEFAULT) PROJECT NAME:
RUSH (100% SURCHARGE)
DUE DATE: LOCATION:
SELECT: PDF REPORT & EMAIL TO: EMAIL 1:
MAIL REPORT EMAIL 2:
FAX REPORT EMAIL 3:
RELINQUISHED BY:
SIGNATURE: DATE: STORE UNTIL*:
PRINTED NAME: TIME:
RECEIVED BY: STANDARD NON-CONTAMINATED SOIL DISPOSAL (DEFAULT)*
SIGNATURE: DATE: CONTAMINATED SOIL DISPOSAL*
PRINTED NAME: TIME: RETURN SAMPLES TO PROJECT MANAGER*
SAMPLE IDENTIFICATION DEPTH SAMPLED BY / DATESAMPLE CONTAINER (PAIL/SHELBY/BAG) A
TT
ER
BE
RG
LIM
ITS
- A
ST
M D
43
18
WA
TE
R (
MO
IST
UR
E)
CO
NT
EN
T -
AS
TM
D2
21
6
pH (
P)
/
W
ater
Sol
uble
Sul
phat
es (
S)
/
Org
anic
Con
tent
(O
)
VA
PO
R,
PN
EU
MA
TIC
OR
AIR
PE
RM
EA
BIL
ITY
OF
PA
TIA
LL
Y S
AT
UR
AT
ED
S
OIL
S
- A
ST
M D
65
39
PA
RT
ICL
E-S
IZE
AN
AL
YS
IS (
FU
LL
GR
AD
AT
ION
) -
AS
TM
D4
22
GR
EA
TE
R T
HA
N N
O.
20
0 (
0.0
75
mm
) S
IEV
E A
NA
LY
SIS
- A
ST
M C
13
6
CO
NT
AM
INA
TE
D?
(Y
/N)
IF
YE
S, A
TT
AC
H D
ET
AIL
S S
UC
H A
S T
YP
E A
ND
L
EV
EL
(H
IGH
OR
LO
W)
OF
CO
NT
AM
INA
NT
.
ON
E-D
IME
NS
ION
AL
CO
NS
OL
IDA
TIO
N P
RO
PE
RT
IES
OF
SO
IL U
SIN
G
INC
RE
ME
NT
AL
LOA
DIN
G -
AS
TM
D24
35
UN
CO
NF
INE
D C
OM
PR
ES
SIV
E S
TR
EN
GT
H -
AS
TM
D2
16
6
LA
BO
RA
TO
RY
MIN
IAT
UR
E V
AN
E S
HE
AR
TE
ST
FO
R S
AT
UR
AT
ED
FIN
E-
GR
AIN
ED
CL
AY
EY
SO
IL -
AS
TM
D4
64
8
BU
LK
DE
NS
ITY
(B)
/
T
OT
AL
PO
RO
SIT
Y &
AIR
-FIL
LE
D P
OR
OS
ITY
(P)
EL
EC
RIC
AL
CO
ND
UC
TIV
ITY
(C)
/ R
ES
IST
IVIT
Y
(R)
*ALL SAMPLES WILL BE DISCARDED AFTER TESTING, UNLESS OTHERWISE NOTED; DISPOSAL, STORAGE AND SHIPPING CHARGES MAY APPLY. WHITE - REPORT COPY, YELLOW - FILE COPY, PINK - CLIENT COPY
SA
MP
LE
ST
OR
AG
E
YES
NO
CHAIN OF CUSTODY / LABORATORY TESTING REQUEST FORM
Email:[email protected]
MA
TE
RIA
LS
FIN
ER
TH
AN
NO
. 2
00
(0
.07
5 m
m)
SIE
VE
- A
ST
M C
11
7
ST
AN
DA
RD
PR
OC
TO
R -
AS
TM
D6
98
MO
DIF
IED
PR
OC
TO
R -
AS
TM
D1
55
7
HY
DR
AU
LIC
CO
ND
UC
TIV
ITY
(P
ER
ME
AB
ILIT
Y)
OF
FIN
E G
RA
INE
D S
OIL
S -
A
ST
M D
50
84
HY
DR
AU
LIC
CO
ND
UC
TIV
ITY
(P
ER
ME
AB
ILIT
Y)
OF
FIN
E G
RA
INE
D S
OIL
S -
F
AL
LIN
G H
EA
D M
ET
HO
D
(US
ED
IN
CO
NJU
NC
TIO
N W
/ P
RO
CT
OR
TE
ST
)
HY
DR
AU
LIC
CO
ND
UC
TIV
ITY
(P
ER
ME
AB
ILIT
Y)
OF
GR
AN
UL
AR
SO
ILS
(C
ON
ST
AN
T H
EA
D)
- A
ST
M D
24
34
INVOICE TO: ANALYSIS REQUESTEDREPORT TO:
TURN AROUND TIME
REPORT DISTRIBUTION
(RUSH ORDERS ONLY)
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
APPENDIX II
SAMPLE OF A GEOTECHNICAL LABORATORY TESTING REPORT
ALL SAMPLE INFORMATION, PROJECT NAMES, DATA, AND RESULTS INCLUDED IN THIS SAMPLE REPORT ARE FICTIONAL AND SHOULD BE USED FOR ILLUSTRATION PURPOSES
ONLY.
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
November 1, 2005 Environmental Engineering Company Suite 1, 2345-6 Street, N.W. Calgary, AB T7T 8Z8 Attention: John Smith EEC Project #: 12345678
SAMPLE REPORT
Geotechnical Laboratory Testing Report SOLUM Job #: 100010501024 Received: October 24, 2005 # of Samples Received: One-5 gal pail, 1 Shelby Tube Test Quantity ASTM Designation Water Content 1 D2216
Atterberg Limits 1 D4318 Full Gradation 1 D422 Standard Proctor 1 D698 Fall Cone Shear Test 1 N/A Vane Shear Test 1 D4648 Hydraulic Conductivity; Remolded at 95% of Maximum Dry Density 1 D5084 Saad A.M. Farag Laboratory Manager Solum Consultants Ltd.
Total Cover Pages: 1
#9, 3620 29 Street NE, Calgary, AB T1Y 5Z8 Ph: (403) 250-3035 Fax: (403) 250-3021 Email: [email protected]
#9, 3620 - 29 Street, NE Project Number:
Calgary, Alberta T1Y 5Z8 Client:
Ph: (403)250-3035 Project Name:
Fax: (403)250-3021 Location:
Email: [email protected] Tested By: Reviewed By:
www.solumconsultantsltd.com Date Reviewed: (dd-mm-yy)
Liqu
id L
imit(
%)
Pla
stic
Lim
it(%
)
Pla
stic
Ind
ex(
%)
Cla
ssifi
catio
n*
(US
CS
)
Cob
ble
Siz
e (%
)(7
5-3
00
mm
)
Gra
vel S
ize
(%)
(4.7
5-7
5m
m)
Sa
nd
Siz
e (
%)
(0.0
75
-4.5
mm
)
Silt
Siz
e (
%)
(0.0
05
-0.0
75
mm
)
Cla
y S
ize
(%)
(<0
.00
5m
m)
Max
imum
Dry
De
nsi
ty (
kg
/m3
)
Opt
imum
Wat
er
Co
nte
nt (
%)
Ove
r S
ize
De
nsi
ty
Co
rre
ctio
n (
kg/m
3 )
Ove
r S
ize
Opt
imum
W
ate
r C
on
ten
t C
orr
ect
ion
(%)
CCL-68680200-05 GR 40.7 83 45 38 MH 0.0 0.8 32.6 35.9 30.7 MH 1068 46.0 N/A N/A 3.6E-08
* Note: Soil classification is for material less than 0.425 mm (material used for Atterberg Limits), this includes the fine sand, silt and clay fraction of the sample. The USCS does not recognize the group symbol CI.
** Note: Soil classification is for the whole sample. Soil classification uses the Atterberg Limits results and the percent fines, percent sand and percent gravel as described in ASTM D2487.
Laboratory Analysis Summary
Atterberg Limits
Mo
istu
re C
on
ten
t(%
) Particle Size Analysis
Sa
mp
le ID
De
pth
(m
)
So
il C
las
sif
ica
tio
n**
Gro
up
Sy
mb
ols
Standard Proctor
Results
Co
ns
tan
t H
ea
d
Pe
rme
ab
ility
k20
(cm
/se
c)
12345678
Geotechnical Engineering Company
Site X Geotechnical Investigation
---
KC/SF
25-Oct-09
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
Tested by:
PREPARED SOLELY FOR THE USE OF OUR CLIENT AS SPECIFIED IN THE ACCOMPANYING REPORT. NO REPRESENTATION OF ANY KIND IS MADE TO OTHER PARITES WITH WHICH SOLUM TESTING LTD. HAS NOT ENTERED INTO A CONTRACT.
Date Tested:
Approved by:
Laboratory Compaction Characteristics of Soil - Standard Proctor (ASTM D698)
1,700
1,800
1,900
2,000
5 7 9 11 13 15 17 19
Water Content (%)
Dry
De
ns
ity
(k
g/m
3 )SAMPLE REPORT
Site X Remediation
Client: Environmental Engineering Company
Project No.: 12345678
Sample ID: TP01
Depth: 0.5 - 1.5 m
RA
26-Oct-05
OVERSIZE CORRECTIONASTM D4718
PREPARED SOLELY FOR THE USE OF OUR CLIENT AS SPECIFIED IN THE ACCOMPANYING REPORT. NO REPRESENTATION OF ANY KIND IS MADE TO OTHER PARTIES WITH WHICH SOLUM CONSULTANTS LTD. HAS NOT ENTERED INTO A CONTRACT.
100% SATURATION CURVE
MAXIMUM DRY DENSITY (γ dmax): 1,910 kg/m3
OPTIMUM WATER CONTENT (w o): 12.0%
95% = 1,815 kg/m³
Particles Retained on the No. 4 (4.75 mm) Sieve (Pc): 2.3 %
GM: 2.55 (Assumed)Corrected Max. Dry Density:
N/ACorrected Opt. Water Content:N/A
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
Plastic Limit (%)
Plasticity Index (%)
-40 Mesh Sieve (y/n)
Unified Soil Classification System
Atterberg Limits (ASTM D4318) - Method A
Number of Blows
Wet Sample Weight +Tare (g)
Liquid Limit (Oven Dried)
1 2 3
Liquid Limit (Air Dried) - Multipoint Method
32
20.70
3.81Weight of Water (g)
18.55
3.33
18.97Dry Sample Weight +Tare (g)
22.7822.21
Container ID
3.66
51.5
6.13Weight of Dry Soil (g)
10 22
---
Results
Liquid Limit (Air Dried) (%)
Liquid Limit (Oven Dried) (%) ---
11.36
5Container ID
Water Content (%)
4
30.43
51
Water Content (%)
Weight of Water (g)
Tare (g)
27.90
2.53
Dry Sample Weight +Tare (g)
14.05
Weight of Dry Soil (g)
Sample Information
24.55
Tare (g)
26.46
17.37
11.4511.24
Wet Sample Weight +Tare (g)
13.95
7.10 7.61
33
18
Plastic Limit
54.3 50.1
y
1.91
Average Water Content (%)
KC Reviewed By: SF
Date Tested: 29-Nov-11 (dd-mmm-yy)
CH
Project Number: 12345678
Client: Geotechnical Engineering Company
Project Name: Site X Geotechnical Investigation
Location: Calgary, AB
Sample ID TP01 Depth: 2.37-2.67 m
Tested By:
18.1
13.85 10.60
18.3% 18.0%
LL % Difference
Flow Curve
49
50
51
52
53
54
55
1 10 100
Number of Blows on Liquid Limit Device
Wa
ter
Co
nte
nt
(%)
25
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
0
10
20
30
40
50
60
70
0 10 20 30 40 50 60 70 80 90 100
Liquid Limit (%)
Pla
sti
cit
y I
nd
ex
(%
)
TP01
ML or OL
MH or OH
CL or OL
CH or OH
CL or ML
Tested by:
PREPARED SOLELY FOR THE USE OF OUR CLIENT AS SPECIFIED IN THE ACCOMPANYING REPORT. NO REPRESENTATION OF ANY KIND IS MADE TO OTHER PARITES WITH WHICH SOLUM TESTING LTD. HAS NOT ENTERED INTO A CONTRACT.
0.005 mm 0.075 mm 0.425 mm 2.0 mm 4.75 mm 19 mm 75 mm 300 mm
Coarse
Clay Silt Cobbles Boulders
Medium Fine Coarse
Gravel
Fine
Sand
Date Tested:
Approved by:
Particle Size Analysis (ASTM C136/D422)
0
20
40
60
80
100
0.001 0.01 0.1 1 10 100 1000
Particle Size (mm)
Per
cen
t F
iner
Th
an (
%)
Site X Remediation KC
25-Oct-05
Client: Environmental Engineering Company
12345678.00 Project No.:
Sample ID: TP01
Depth: 0.5 - 1.5 m
Cobbles:
Gravel:
Sand:
Silt:
Clay:
0.0
2.3
35.3
31.2
31.2
Particle Size (%)
PREPARED SOLELY FOR THE USE OF OUR CLIENT AS SPECIFIED IN THE ACCOMPANYING REPORT. NO REPRESENTATION OF ANY KIND IS MADE TO OTHER PARTIES WITH WHICH SOLUM CONSULTANTS LTD. HAS NOT ENTERED INTO A CONTRACT.
RA
SAMPLE REPORT
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
Client: Borehole No.: Tested by: KC / SF
Project No.: Sample No.:
Project Name: Site X Remediation Depth of Sample:
Location: Date of Testing: 17-Jan-08 ( dd -mm -yy)
DATE TIME ELAPSED TIME
TEMP. RtIN BURRETS OUT BURRETS
(MIN) (MIN) (SEC) (deg. C) READINGVOLUME
(cm3)
CHANGE
(cm3)
TOTAL
(cm3)READING
VOLUME
(cm3)
CHANGE
(cm3)
TOTAL
(cm3)
27-Jan-08 0:01 17 1.079 20 41.28 20 41.282:30 149.00 149 8940 17 1.079 19.7 40.66 0.62 0.62 21.2 43.76 2.48 2.485:00 299.00 150 9000 17 1.079 19.4 40.04 0.62 1.24 21.4 44.17 0.41 2.89
3.9E-08 cm/sec
Wet Mass: 257.37 gr Top Pore Pressure: 385 kPa Sample Height : 3.33 cm
Water Content: 27.3% Bottom Pore Pressure: 400 kPa Sample Diameter : 7.24 cm
Wet Density: 1880.7 kg/m3 Cell Pressure: 415 kPa Sample Area : 41.13 cm2
Dry Density: 1477.3 kg/m3 Hydraulic Gradient: Sample Volume : 136.85 cm3
Remarks:
INCREMENTAL TIME
TP01
Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter
( ASTM D5084 )
Hydraulic Conductivity K20 (cm/sec)
4.0-4.5 m
12345678
Envoironmental Engineering Company
Calgary, AB
46.0
Reported
3.95E-083.94E-08
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
Tested by:
Date Tested:
Approved by:
Laboratory Compaction Characteristics of Soil - Standard Proctor (ASTM D698)
y = -5.2989Ln(x) + 26.164
0
10
20
30
40
50
60
0.001 0.01 0.1 1 10 100
Shear Strength (t/m2)
Wa
ter
Co
nte
nt
(%)
Site X Remediation
Client: Environmental Engineering Company
Project No.: 12345678
Sample ID: TP01
Depth: 0.5 - 1.5 m
RA
26-Oct-05
PREPARED SOLELY FOR THE USE OF OUR CLIENT. NO REPRESENTATION OF ANY KIND IS MADE TO OTHER PARTIES WITH WHICH SOLUM CONSULTANTS LTD. HAS NOT ENTERED INTO A CONTRACT.
Shear Strength vs. Water Content (Fall Cone Test)
SAMPLE REPORT
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
Tested by:
Date Tested:
Approved by:
Laboratory Compaction Characteristics of Soil - Standard Proctor (ASTM D698)
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
Rotation (Degree)
Un
dra
ined
Sh
ear
Str
eng
th (
kPa
)
Undisturbed Undrained Shear Strength = 76.15kPaMaximum Torque = 0.3265 N/m
Site X Remediation
Client: Environmental Engineering Company
Project No.: 12345678
Sample ID: TP01
Depth: 0.5-1.5 m
RA
26-Oct-05
PREPARED SOLELY FOR THE USE OF OUR CLIENT. NO REPRESENTATION OF ANY KIND IS MADE TO OTHER PARTIES WITH WHICH SOLUM CONSULTANTS LTD. HAS NOT ENTERED INTO A CONTRACT.
Laboratory Miniature Vane Shear Test for Saturated Fine-Grained Clayey Soil - ASTM D4648
Rotation Rate: 60°/min
Remoulded Undrained Shear Strength = 32.13 kPaMaximum Torque = 0.1378 N/m
Water Content:15.5%
SAMPLE REPORT
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
Boring No. N/A Job No. N/A
Sample No. B1 Job Name N/A
Depth (ft) 5.0 m Tested By SF/KC
Date 11/5/2010 Calculated By KC
Sheet No. Checked By SF
SPECIMEN DIAMETER 7.34 (cm) MOISTURE CONTENT 21.0 (%)SPECIMEN HEIGHT 15.48 (cm) MASS OF WET SAMPLE 1273.1 (g)SPECIMEN AREA 42.27 (cm2) HEIGHT/DIAMETER RATIO 2.11SPECIMEN VOLUME 654.41 (cm3) WET BULK DENSITY 1945.4 (kg/m3)ASSUMED Gs 2.75 INITIAL SATURATION 81.3 (%)INITIAL VOID RATIO 0.71
Shear Strength 76.36 (kPa) Unconfined Compressive Strength 152.72 (kPa)Axial Failure Strain 9.47 (%)
VERT. LOAD 1 1-3 1-3)/2 DISPL. CELL
(cm) (kN) (%) (kPa) (kPa) 0.00 0.00 0.00 0.00 0.00 0.13 0.16 0.85 37.25 18.62 0.28 0.29 1.84 67.46 33.73 0.41 0.39 2.64 88.83 44.41 0.57 0.49 3.71 111.16 55.58 0.74 0.56 4.81 126.12 63.06 0.91 0.62 5.87 137.59 68.79 1.08 0.66 6.99 145.45 72.73 1.30 0.70 8.37 151.01 75.50 1.47 0.71 9.47 152.72 76.36 1.60 0.72 10.30 152.16 76.08 1.75 0.68 11.29 142.71 71.36 1.84 0.59 11.86 123.18 61.59
UNCONFINEDCOMPRESSION TEST (ASTM D2166)
S LUMTM
CONSULTANTS LTD.
Boring No. N/A Job No. N/A
Sample No. B1 Job Name N/A
Depth (ft) 5.0 m Tested By SF/KC
Date 11/5/2010 Calculated By KC
Sheet No. Checked By SF
0
100
200
0 2 4 6 8 10 12 14
Axial Strain (%)
Dev
iato
r St
ress
(kP
a)
S LUMTM
CONSULTANTS LTD.
UNCONFINEDCOMPRESSION TEST (ASTM D2166)
Stress-Strain Plot
X Remoulded
0.1270
Normal Stress (kPa)
200
400
600
---
N/A
Sample Information
Location:
Reviewed By:
(dd-mmm-yy)20-Nov-09Date of Testing:
Depth:Sample ID:
Residual Stress(kPa)
---
BH-01
Tested By: SF/KC
Horizontal Disp. (mm) Add WaterShearing Rate (mm/min)Peak Stress(kPa)
Direct Shear Test of Soils Under Consolidated Drained Conditions (ASM D3080)Project Number:
Client:
Project Name:
12345678
Geotechnical Engineering Company
Site X Geotechnical Investigation
SF
3
Specimen No.
5.6
0.1270
0.1270---
Yes
1
2
7.5
6.2
120.1
Sample Preparation Method:
222.5
309.1
---
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
Specimen3
Specimen2
Specimen1
SWELL/CONSOLIDATION TEST DATA
Client: Solum Consultants Ltd.Project: Barrhead Geotechnical InvestigationProject Number: 10012
Sample Data
Source:Sample No.: B1Elev. or Depth: 5' Sample Length(in./cm.): Location:Description:Liquid Limit: Plasticity Index: USCS: AASHTO: Figure No.: Testing Remarks:
Test Specimen Data
TOTAL SAMPLE BEFORE TEST AFTER TESTWet w+t = 57.83 g. Consolidometer # = 1 Wet w+t = 169.47 g.Dry w+t = 50.24 g. Dry w+t = 145.83 g.Tare Wt. = 14.05 g. Spec. Gravity = 2.8 Tare Wt. = 43.00 g.Height = 2.00 cm. Height = 2.00 cm.Diameter = 6.18 cm. Diameter = 6.18 cm.Weight = 124.43 g. Defl. Table = reference Set (mm/kPa)
Moisture = 21.0 % Ht. Solids = 1.2247 cm. Moisture = 23.0 %Wet Den. = 2074 kg/m3 Dry Wt. = 102.86 g.* Dry Wt. = 102.83 g. Dry Den. = 1715 kg/m3 Void Ratio = 0.633 Void Ratio = 0.618
Saturation = 92.8 %
* Initial dry weight used in calculations
End-of-Load Summary
Pressure(kPa)
FinalDial (cm.)
MachineDefl. (cm.)
Corrected(cm.)
VoidRatio
% Compression/Swell
start -0.01200 0.633 25.00 0.00660 0.00010 0.00670 0.648 0.9 Swell 50.00 -0.00480 0.00050 -0.00430 0.639 0.4 Swell
100.00 -0.03040 0.00080 -0.02960 0.619 0.9 Comprs. 200.00 -0.06840 0.00180 -0.06660 0.589 2.7 Comprs. 400.00 -0.11860 0.00270 -0.11590 0.548 5.2 Comprs. 800.00 -0.18020 0.00340 -0.17680 0.499 8.2 Comprs. 400.00 -0.17540 0.00300 -0.17240 0.502 8.0 Comprs. 100.00 -0.13320 0.00200 -0.13120 0.536 6.0 Comprs. 25.00 -0.03040 0.00010 -0.03030 0.618 0.9 Comprs.
Cc = 0.17 Pc = 132.17 kPa Cr = 0.07
Solum Consultants Ltd.
RatioMoistureSaturationInitial VoidCrCc
PcOverburdenSp. Gr.PILLDry Dens.Natural
Project:Remarks:Client:Project No.
AASHTOUSCSMATERIAL DESCRIPTION
CONSOLIDATION TEST REPORT
10 20 50 100 200 500.47
.49
.51
.53
.55
.57
.59
.61
.63
.65
.67V
oid
Rat
io
Applied Pressure - kPaCoefficients of Consolidation and Secondary Consolidation
No. Load(kPa)
Cv(cm.2/sec.)
C� No. Load(kPa)
Cv(cm.2/sec.)
C� No. Load(kPa)
Cv(cm.2/sec.)
C�
2 50.00 0.00503 100.00 0.00174 200.00 0.00015 400.00 0.00006 800.00 0.00007 400.00 0.00028 100.00 0.00009 25.00 0.0000
(kPa)(kPa)(kg/m3)
Barrhead Geotechnical InvestigationSolum Consultants Ltd.10012
0.6330.070.17132.172.8171521.0 %92.8 %
Figure
Source: Sample No.: B1 Elev./Depth: 5'
=
=D100
=
=D0
Load=
Load No.=
Project:Project No.:
Dial Reading vs. Time
Cv @ T90
0.0050 cm.2/sec.
T90
D90
Source: Sample No.: B1 Elev./Depth: 5'
2.86 min.
-0.00010
0.00026
0.00354
50.00 kPa
2
Barrhead Geotechnical Investigation10012
Square Root of Elapsed Time (min.)
Dia
l Rea
ding
(cm
.)
0 4 8 12 16 20 24 28 32 36 40-.005
-.004
-.003
-.002
-.001
.000
.001
.002
.003
.004
.005t90
FigureSolum Consultants Ltd.
Cv @ T90
0.0017 cm.2/sec.
=T90
=D100
=D90
=D0
Load=
Load No.=
Source: Sample No.: B1 Elev./Depth: 5'
8.47 min.
-0.01635
-0.01560
-0.00881
100.00 kPa
3
Square Root of Elapsed Time (min.)
Dia
l Rea
ding
(cm
.)
0 4 8 12 16 20 24 28 32 36 40-.033
-.030
-.027
-.024
-.021
-.018
-.015
-.012
-.009
-.006
-.003t90
SOLUM CONSULTANTS LTD.One-Dimensional Swell Test (ASTM D 4546)
JOB NAME N/A JOB NO. N/ABORING NO. SAMPLE NO. BH10-01 DEPTH 1.50-2.50 m TEST DATE 12/6/2009SAMPLE DESCRIPTION Silty clay w/ trace of gravels
Applied Dial Applied Dial Applied Dial
Pressure Reading Pressure Reading Pressure Reading(kPa) (in) (kPa) (in) (kPa) (in)
0 0.0000 300 -0.0293 0 0.000025 -0.0075 200 -0.0291 25 -0.001650 -0.0101 100 -0.0279 50 -0.0023100 -0.0145 50 -0.0265 100 -0.0038200 -0.0222 25 -0.0251 200 -0.0067300 -0.0293 0 -0.0208 300 -0.0105
300 -0.0215
Dial Reading Before Inundate -0.0105 in Swell Pressure 300 (kPa)
Dial Reading After Inundate -0.0215 in
Swell or Collapse Strain -1.1 (%)
Un-Loading Loading ( II )Loading ( I )
-0.050
-0.040
-0.030
-0.020
-0.010
0.000
0.010
0.020
0.030
0.040
0.050
0 100 200 300 400
Applied Pressure, (kPa)
Def
orm
atio
n, (
in)
Swell Pressure
Boring No. Job No.Sample No. Job Name Keystone XL Pipeline PS5Depth (m) Tested ByDate Calculated BySheet No. Checked By
STAGE1SPECIMEN DIAMETER 7.199 (cm) CELL PRESSURE (CP) 565.0 (kPa)SPECIMEN HEIGHT 13.376 (cm) BACK PRESSURE (BP) 165.0 (kPa)SPECIMEN AREA 40.678 (sq.cm) EFFECTIVE PRESSURE (EP) 400.0 (kPa)SPECIMEN VOLUME 544.092 (cu.cm)
Failure Criteria: Max. Deviator StressAxial Failure Strain 1.52 (%)
(�1-�3)f 144.74 (kPa) (�3)f 400.00 (kPa) (�1)f 544.74 (kPa)(�u)f 165.47 (kPa) (�3')f 234.53 (kPa) (�1')f 379.27 (kPa)
VERT. LOAD �u �1 �1-�3 �1' �3' p p' q �1' /�3'DISPL. CELL (cm) (KN) (kPa) (%) (kPa) (kPa) (kPa) (kPa) (kPa) (kPa)
0.00 0.00 0.00 0.00 0.00 400.00 400.00 400.00 400.00 0.00 10.02 0.13 15.86 0.11 30.80 414.94 384.14 415.40 399.54 15.40 1.080.03 0.22 35.85 0.23 54.55 418.70 364.15 427.28 391.42 27.28 1.150.05 0.29 55.16 0.34 71.93 416.77 344.84 435.96 380.80 35.96 1.210.06 0.35 72.39 0.46 85.67 413.27 327.61 442.83 370.44 42.83 1.260.07 0.39 86.87 0.55 96.35 409.48 313.13 448.18 361.30 48.18 1.310.09 0.42 102.04 0.66 103.63 401.59 297.96 451.81 349.77 51.81 1.350.11 0.47 117.21 0.80 113.58 396.37 282.79 456.79 339.58 56.79 1.400.13 0.50 128.24 0.95 121.42 393.18 271.76 460.71 332.47 60.71 1.450.15 0.54 144.10 1.12 130.29 386.19 255.90 465.15 321.05 65.15 1.510.18 0.57 155.82 1.33 139.19 383.37 244.18 469.59 313.77 69.59 1.570.20 0.60 165.47 1.52 144.74 379.26 234.53 472.37 306.89 72.37 1.62
08E4490
SF & KCSF SF
N/APS5-2009-064.57-5.23 m1/10/2010 CONSOLIDATED-UNDRAINED
TRIAXIAL COMPRESSION TESTASTM D4767
S LUMTM
CONSULTANTS LTD.
Boring No. N/A Job No. 08E4490Sample No. PS5-2009-06 Job Name Keystone XL Pipeline PS5Depth (m) 4.57-5.23 m Tested By SF & KCDate Calculated By SFSheet No. Checked By SF
1/10/2010
0
50
100
150
200
250
300
350
400
0 1 2 3 4 5 6
Axial Strain (%)
Dev
iato
r St
ress
(kPa
)
Effective Confining Pressure=400.0 kPaEffective Confining Pressure=600.0 kPaEffective Confining Pressure=800.0 kPa
CONSOLIDATED-UNDRAINEDTRIAXIAL COMPRESSION TEST
ASTM D4767
S LUMTM
CONSULTANTS LTD.
Boring No. N/A Job No. 08E4490Sample No. PS5-2009-06 Job Name Keystone XL Pipeline PS5Depth (m) 4.57-5.23 m Tested By SF & KCDate Calculated By SFSheet No. Checked By SF
1/10/2010 CONSOLIDATED-UNDRAINEDTRIAXIAL COMPRESSION TEST
ASTM D4767
0
100
200
300
400
500
600
0 200 400 600 800 1000 1200
Normal Stress (kPa)
Shea
r St
ress
(kPa
)
Total Stress
0
100
200
300
0 100 200 300 400 500 600 700 800 900
p' (kPa)
q (k
Pa)
Effective Confining Pressure=400.0 kPaEffective Confining Pressure=600.0 kPaEffective Confining Pressure=800.0 kPa
S LUMTM
CONSULTANTS LTD.
p-q&Mohr Chart 2
Page 1
0
100
200
300
400
500
600
0 200 400 600 800 1000 1200
Normal Stress (kPa)
Shea
r St
ress
(kPa
)
Total Stress
Effective Stress
Keystone XL Pipeline PS3 08E4490Keystone XL Pipeline PS3 08E4490Monitor ABMonitor, AB
CALIFORNIA BEARING RATIOCALIFORNIA BEARING RATIO ASTM D 1883-05 (One Water Content only)CALIFORNIA BEARING RATIO ASTM D 1883 05 (One Water Content only)
PS3 2009 09 B lkPS3-2009-09 BulkBrown Lean Clay (CL)Brown Lean Clay (CL)S h A 4 54 KSurcharge Amount: 4.54 Kg.Su c a ge ou t: .5 g.
95% O ti M i t C t t95% Optimum Moisture Contentp
10 Blows 25 Blows 56 Blows10 Blows 25 Blows 56 BlowsDry density before soak, kg/m^3 1,541 1,639 1,690Dry density before soak, kg/m 3 1,541 1,639 1,690D d it ft k k / ^3 1 554 1 649 1 698Dry density after soak, kg/m^3 1,554 1,649 1,698y y , g , , ,Moisture content before soak % 19 5 19 8 19 8Moisture content before soak, % 19.5 19.8 19.8Moisture content after soak avg % 27 4 25 3 23 7Moisture content after soak, avg., % 27.4 25.3 23.7Moisture content after soak, top 1", % 29.5 27.1 25.1Moisture content after soak, top 1 , % 29.5 27.1 25.1
ll f h k% Swell after 96 hour soak -0.83 -0.61 -0.48% Swell after 96 hour soak 0.83 0.61 0.48B i R ti 0 100" t ti 0 4 1 0 1 5Bearing Ratio, 0.100" penetration 0.4 1.0 1.5g , p
Dry Density vs CBRDry Density vs CBRDry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
Dry Density vs CBR
5
BR
Dry Density vs CBR
5
BR
Dry Density vs CBR
5
CB
R
Dry Density vs CBR
5
cted
CB
R
Dry Density vs CBR
5
cted
CB
R
Dry Density vs CBR
5
rrec
ted
CB
R
Dry Density vs CBR
5
Cor
rect
ed C
BR
Dry Density vs CBR
5
Cor
rect
ed C
BR
Dry Density vs CBR
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
25 blows per layer
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
25 blows per layer
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
25 blows per layer
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
5
Cor
rect
ed C
BR
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
0
5
Cor
rect
ed C
BR
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
0
5
1400 1600 1800
Cor
rect
ed C
BR
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
0
5
1400 1600 1800
Cor
rect
ed C
BR
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
0
5
1400 1600 1800
Cor
rect
ed C
BR
Dry Density as Molded, kg/m^3
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
0
5
1400 1600 1800
Cor
rect
ed C
BR
Dry Density as Molded, kg/m^3
Dry Density vs CBR
10 blows per layer
25 blows per layer
56 blows per layer
0
5
1400 1600 1800
Cor
rect
ed C
BR
Dry Density as Molded, kg/m^3
Dry Density vs CBR
TP-1
Sample Report
Keystone XL Pipeline PS3Keystone XL Pipeline PS3Monitor ABMonitor, AB
S i @ i i CStress vs. Penetration @ 95% Optimum Moisture ContentStress vs. Penetration @ 95% Optimum Moisture Content
100100100100100100100100100100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
10 Blows 25 Blows 56 Blows
100
)
10 Blows 25 Blows 56 Blows
100
psi )
10 Blows 25 Blows 56 Blows
100
psi )
10 Blows 25 Blows 56 Blows
50
100
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
0
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
0
50
100
Stre
ss (
psi )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
P t ti ( i )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
0
50
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Stre
ss (
psi )
Penetration ( in )
10 Blows 25 Blows 56 Blows
Sample Report
Client: Borehole No.: N/A Tested by:
Project No.: BH09-01
Project Name: Depth: 4.5-5.0 m
Location: Date : 15-Oct-09 ( dd -mm -yy)
TEMP.
(deg. C)
1 21.0 2250 270 1980 90 8.89E+01 O
2 21.0 7200 570 6630 250 2.41E+02 O
3 21.0 12560 1200 11360 290 2.72E+02 V
4 21.0 16450 2150 14300 370 3.39E+02 V
5 21.0 21000 3360 17640 500 4.47E+02 V
6 21.0 26000 4850 21150 680 5.91E+02 V
Average:
Test Method: √ Test Gas: √
Specimen Type:
Undisturbed
Wet Mass: 420.36 g Sample Height : cm
Water Content: 18.6% Sample Diameter : cm
Wet Density: 2178.0 kg/m3 Sample Area : cm2
Dry Density: 1836.5 kg/m3 Sample Volume : cm3
Remarks:
O-OutlierV-Valid
102.4Barometric Pressure (kPa):
Flexible Wall N2
1.1E-01
Pressure Drop( Pa )
Sample No.:
Rigid Wall Air
4.78
7.17
Experiment
No.
Inlet Pressure
( Pa )
Outlet Pressure
( Pa )
BubbleMeter
Reading( cc/min )
Measurement of Pneumatic Permeability of Partially Saturated Porous Material ( ASTM D6539 )
Pneumatic ConductivityKp (Darcy)
XYZ Environmental Ltd.
12345678
X Site Assessment
X Site
Qav(cc/min)
KC / SF
40.38
193.00
1.89E-01
1.53E-01
1.01E-01
9.98E-02
1.07E-01
1.18E-01
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
0
100
200
300
400
500
600
700
800
0 5000 10000 15000 20000 25000
∆ P (Pa)
QA
V (c
c/m
in)
+25% limit
-25% limit
Linear (Best Fit)
Proctor Information:
Standard Test Method for Determine the Thermal Conductivity/Resistivity of Soils (ASTM D5334)Project Number:
Client:
Project Name:
N/A
N/A
N/A
Tested By:
Date of Testing:
SFKC/SF
(dd-mmm-yy)9-Mar-10
Reviewed By:
Sample ID: TP-1 Depth:
---
Bulk
Location:
21.8
Results
4
5.0
1760.0
129
20.1
5
9.2
1758.0
3
3.4
1750.0
164
2
1.7
1737.0
266
21.8Temperature ( oC)
1
0.7
1725.0
427
24.3
Specimen No.
Moisture Content (%)
Dry Density (kg/m3)
Thermal Resistyvity (k-cm/watt)
20.4
6
13.5
1765.0
78
19.1
86
Max. Dry Density (kg/m3):
Opt. Moisture Content (%):
Target % Compaction:
Target Dry Density(kg/m3):
1855.0
14.2
95%
1762.3
S LUMTM
GEOTECHNICAL & MATERIAL TESTING LABORATORY
CONSULTANTS LTD.
Thermal Resistivity Dry-Out Curve
0
100
200
300
400
500
0.0 5.0 10.0 15.0 20.0
Moisture Content (%)
Th
erm
al
Re
sis
tiv
ity
(K
-cm
/wa
tt)