SUBMITTAL
B-139.10B
JOB: REPRESENTATIVE:
UNIT TAG: ORDER NO. DATE:
ENGINEER: SUBMITTED BY: DATE: CONTRACTOR: APPROVED BY: DATE:
DESCRIPTION: The Series e-80 is a highly efficient, heavy duty, close coupled pump designed for horizontal or vertical in-line mounting. The e-80 is available in stainless steel fitted construction, with flows up to 2500 GPM, heads to 380 feet.
Series e-80 2.5x2.5x9.5CClose Coupled In-Line Centrifugal Pump
SPECIFICATIONS
FLOW HEAD
HP RPM
VOLTS
CYCLEINPUT PHASE
ENCLOSURE
APPROX. WEIGHT
SPECIALS
MATERIALS OF CONSTRUCTION Stainless Steel Fitted
MAXIMUM WORKING PRESSURE 175 psi (12 bar) with 125# ANSI flange drilling
250 psi (17 bar) with 250# ANSI flange drilling (requires 80-S)
300 psi (21 bar) W.P. with 250# ANSI flange drilling (Requires -S and EPR-Silicon Carbide-Silicon Carbide Seal)
MOUNTING
In-Line Piping Flange Supports
PUMP VARIABLE SPEED CONTROL Integrated Technologic® Sensorless Control (ITSC)
Integrated Technologic® (IT)
External input by others
Pressure Sensor(s)
Differential Pressure Sensor(s)
Flow Sensor(s)
By Others
TYPE OF SEAL -F Standard Seal w/ Flush Line(Buna-Carbon/Ceramic)
-S Stuffing Box construction w/ Flushed MechanicalSingle Seal (EPR-Tungsten Carbide/Carbon)
-PF Stuffing Box Construction w/ Flushed Packing (Graphite Impregnated PTFE)
SUBMITTAL
B-139.10B
JOB: REPRESENTATIVE:
UNIT TAG: ORDER NO. DATE:
ENGINEER: SUBMITTED BY: DATE: CONTRACTOR: APPROVED BY: DATE:
DESCRIPTION: The Series e-80 is a highly efficient, heavy duty, close coupled pump designed for horizontal or vertical in-line mounting. The e-80 is available in stainless steel fitted construction, with flows up to 2500 GPM, heads to 380 feet.
Series e-80 2.5x2.5x9.5CClose Coupled In-Line Centrifugal Pump
SPECIFICATIONS
FLOW HEAD
HP RPM
VOLTS
CYCLEINPUT PHASE
ENCLOSURE
APPROX. WEIGHT
SPECIALS
MATERIALS OF CONSTRUCTION Stainless Steel Fitted
MAXIMUM WORKING PRESSURE 175 psi (12 bar) with 125# ANSI flange drilling
250 psi (17 bar) with 250# ANSI flange drilling (requires 80-S)
300 psi (21 bar) W.P. with 250# ANSI flange drilling (Requires -S and EPR-Silicon Carbide-Silicon Carbide Seal)
MOUNTING
In-Line Piping Flange Supports
PUMP VARIABLE SPEED CONTROL Integrated Technologic® Sensorless Control (ITSC)
Integrated Technologic® (IT)
External input by others
Pressure Sensor(s)
Differential Pressure Sensor(s)
Flow Sensor(s)
By Others
TYPE OF SEAL -F Standard Seal w/ Flush Line(Buna-Carbon/Ceramic)
-S Stuffing Box construction w/ Flushed MechanicalSingle Seal (EPR-Tungsten Carbide/Carbon)
-PF Stuffing Box Constructionw/ Flushed Packing (Graphite Impregnated PTFE)
SUBMITTAL
B-139.10B
JOB: REPRESENTATIVE:
UNIT TAG: ORDER NO. DATE:
ENGINEER: SUBMITTED BY: DATE: CONTRACTOR: APPROVED BY: DATE:
DESCRIPTION: The Series e-80 is a highly efficient, heavy duty, close coupled pump designed for horizontal or vertical in-line mounting. The e-80 is available in stainless steel fitted construction, with flows up to 2500 GPM, heads to 380 feet.
Series e-80 2.5x2.5x9.5CClose Coupled In-Line Centrifugal Pump
SPECIFICATIONS
FLOW HEAD
HP RPM
VOLTS
CYCLEINPUT PHASE
ENCLOSURE
APPROX. WEIGHT
SPECIALS
MATERIALS OF CONSTRUCTION Stainless Steel Fitted
MAXIMUM WORKING PRESSURE 175 psi (12 bar) with 125# ANSI flange drilling
250 psi (17 bar) with 250# ANSI flange drilling (requires 80-S)
300 psi (21 bar) W.P. with 250# ANSI flange drilling (Requires -S and EPR-Silicon Carbide-Silicon Carbide Seal)
MOUNTING
In-Line Piping Flange Supports
PUMP VARIABLE SPEED CONTROL Integrated Technologic® Sensorless Control (ITSC)
Integrated Technologic® (IT)
External input by others
Pressure Sensor(s)
Differential Pressure Sensor(s)
Flow Sensor(s)
By Others
TYPE OF SEAL -F Standard Seal w/ Flush Line(Buna-Carbon/Ceramic)
-S Stuffing Box construction w/ Flushed MechanicalSingle Seal (EPR-Tungsten Carbide/Carbon)
-PF Stuffing Box Constructionw/ Flushed Packing (Graphite Impregnated PTFE)
Series e-80 2.5x2.5x9.5C Close Coupled In-Line Centrifugal Pump B-139.10B
In-Line Piping DIMENSIONS - Inches (mm) STANDARD SEAL
MOTOR FRAME
A B C D E (max) F G H (max)125# ANSI 250# ANSI
R S (Max)* V (min)Suct/Disch Gauge Taps
(NPT)
Drain Tap (NPT)J N P J N P
145JM10.75 21.50 5.96 7.06 12.63 4.81 6.00 23.44 5.50 4 0.75 5.88 8 0.88 9.75 1.50 4.75 0.25 0.25
(273) (546) (151) (179) (321) (122) (152) (595) (140) (19) (149) (22) (248) (38) (121)
182JM10.75 21.50 5.96 7.06 15.31 4.81 6.00 26.13 5.50 4 0.75 5.88 8 0.88 11.75 1.00 4.75 0.25 0.25
(273) (546) (151) (179) (389) (122) (152) (664) (140) (19) (149) (22) (298) (25) (121)
184JM10.75 21.50 5.96 7.06 15.31 4.81 6.00 26.13 5.50 4 0.75 5.88 8 0.88 11.75 1.00 4.75 0.25 0.25
(273) (546) (151) (179) (389) (122) (152) (664) (140) (19) (149) (22) (298) (25) (121)
213JM10.75 21.50 5.96 7.06 19.25 4.81 6.00 30.06 5.50 4 0.75 5.88 8 0.88 14.00 0.00 4.75 0.25 0.25
(273) (546) (151) (179) (489) (122) (152) (764) (140) (19) (149) (22) (356) (121)
215JM10.75 21.50 5.96 7.06 19.25 4.81 6.00 30.06 5.50 4 0.75 5.88 8 0.88 14.00 0.00 4.75 0.25 0.25
(273) (546) (151) (179) (489) (122) (152) (764) (140) (19) (149) (22) (356) (121)
254JM10.75 21.50 5.96 7.06 24.13 5.81 6.00 35.94 5.50 4 0.75 5.88 8 0.88 17.00 0.00 4.75 0.25 0.25
(273) (546) (151) (179) (613) (148) (152) (913) (140) (19) (149) (22) (432) (121)
256JM10.75 21.50 5.96 7.06 24.13 5.81 6.00 35.94 5.50 4 0.75 5.88 8 0.88 17.00 0.00 4.75 0.25 0.25
(273) (546) (151) (179) (613) (148) (152) (913) (140) (19) (149) (22) (432) (121)
284JM10.75 21.50 5.96 7.06 23.63 5.81 6.00 35.44 5.50 4 0.75 5.88 8 0.88 16.13 4.63 4.75 0.25 0.25
(273) (546) (151) (179) (600) (148) (152) (900) (140) (19) (149) (22) (410) (117) (121)
286JM10.75 21.50 5.96 7.06 25.13 5.81 6.00 36.94 5.50 4 0.75 5.88 8 0.88 16.13 4.63 4.75 0.25 0.25
(273) (546) (151) (179) (638) (148) (152) (938) (140) (19) (149) (22) (410) (117) (121)
324JM10.75 21.50 5.96 7.06 26.00 5.81 6.00 37.81 5.50 4 0.75 5.88 8 0.88 18.75 5.38 4.75 0.25 0.25
(273) (546) (151) (179) (660) (148) (152) (960) (140) (19) (149) (22) (476) (137) (121)
326JM10.75 21.50 5.96 7.06 26.00 5.81 6.00 37.81 5.50 4 0.75 5.88 8 0.88 18.75 5.38 4.75 0.25 0.25
(273) (546) (151) (179) (660) (148) (152) (960) (140) (19) (149) (22) (476) (137) (121)
Dimensions are subject to change. Not to be used for construction purposes unless certified.
NOTE: For Single phase Motors add 1" to dimensions E & H.
*Dimensions are for ODP Motors. For TEFC add S dimension to dimensions E & H.
Xylem Inc. 8200 N. Austin Avenue, Morton Grove, IL 60053 Phone: (847)966-3700 Fax: (847)965-8379 www.xylem.com/bellgossett
Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. © 2019 Xylem Inc.
1P0354
Series e-80 2.5x2.5x9.5C Close Coupled In-Line Centrifugal Pump B-139.10B
In-Line Piping DIMENSIONS - Inches (mm) STUFFING BOX
MOTOR FRAME
A B C D E (max) F G H (max)125# ANSI 250# ANSI
R S (Max)* V (min)Suct/Disch Gauge Taps
(NPT)
Drain Tap (NPT)J N P J N P
145JP10.75 21.50 5.96 7.06 12.63 7.94 6.00 26.56 5.50 4 0.75 5.88 8 0.88 9.75 1.50 4.75 0.25 0.25
(273) (546) (151) (179) (321) (202) (152) (675) (140) (19) (149) (22) (248) (38) (121)
182JP10.75 21.50 5.96 7.06 15.31 7.94 6.00 29.25 5.50 4 0.75 5.88 8 0.88 11.75 1.00 4.75 0.25 0.25
(273) (546) (151) (179) (389) (202) (152) (743) (140) (19) (149) (22) (298) (25) (121)
184JP10.75 21.50 5.96 7.06 15.31 7.94 6.00 29.25 5.50 4 0.75 5.88 8 0.88 11.75 1.00 4.75 0.25 0.25
(273) (546) (151) (179) (389) (202) (152) (743) (140) (19) (149) (22) (298) (25) (121)
213JP10.75 21.50 5.96 7.06 19.25 8.69 6.00 33.94 5.50 4 0.75 5.88 8 0.88 14.00 0.00 4.75 0.25 0.25
(273) (546) (151) (179) (489) (221) (152) (862) (140) (19) (149) (22) (356) (121)
215JP10.75 21.50 5.96 7.06 19.25 8.69 6.00 33.94 5.50 4 0.75 5.88 8 0.88 14.00 0.00 4.75 0.25 0.25
(273) (546) (151) (179) (489) (221) (152) (862) (140) (19) (149) (22) (356) (121)
254JP10.75 21.50 5.96 7.06 24.13 8.69 6.00 38.81 5.50 4 0.75 5.88 8 0.88 17.00 0.00 4.75 0.25 0.25
(273) (546) (151) (179) (613) (221) (152) (986) (140) (19) (149) (22) (432) (121)
256JP10.75 21.50 5.96 7.06 24.13 8.69 6.00 38.81 5.50 4 0.75 5.88 8 0.88 17.00 0.00 4.75 0.25 0.25
(273) (546) (151) (179) (613) (221) (152) (986) (140) (19) (149) (22) (432) (121)
284JP10.75 21.50 5.96 7.06 23.63 8.69 6.00 38.31 5.50 4 0.75 5.88 8 0.88 16.13 4.63 4.75 0.25 0.25
(273) (546) (151) (179) (600) (221) (152) (973) (140) (19) (149) (22) (410) (117) (121)
286JP10.75 21.50 5.96 7.06 25.13 8.69 6.00 39.81 5.50 4 0.75 5.88 8 0.88 16.13 4.63 4.75 0.25 0.25
(273) (546) (151) (179) (638) (221) (152) (1011) (140) (19) (149) (22) (410) (117) (121)
324JP10.75 21.50 5.96 7.06 26.00 8.69 6.00 40.69 5.50 4 0.75 5.88 8 0.88 18.75 5.38 4.75 0.25 0.25
(273) (546) (151) (179) (660) (221) (152) (1033) (140) (19) (149) (22) (476) (137) (121)
326JP10.75 21.50 5.96 7.06 26.00 8.69 6.00 40.69 5.50 4 0.75 5.88 8 0.88 18.75 5.38 4.75 0.25 0.25
(273) (546) (151) (179) (660) (221) (152) (1033) (140) (19) (149) (22) (476) (137) (121)
Dimensions are subject to change. Not to be used for construction purposes unless certified.
NOTE: For Single phase Motors add 1" to dimensions E & H.
*Dimensions are for ODP Motors. For TEFC add S dimension to dimensions E & H.
Xylem Inc. 8200 N. Austin Avenue, Morton Grove, IL 60053 Phone: (847)966-3700 Fax: (847)965-8379 www.xylem.com/bellgossett
Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. © 2019 Xylem Inc.
1P0354
Series e-80 2.5x2.5x9.5C Close Coupled In-Line Centrifugal Pump B-139.10B
Flange Support Mounting DIMENSIONS - Inches (mm) STANDARD SEAL
MOTOR FRAME
AHF
BOLTINGHB
2HE BOLTING
HAHH DIA
E (max) F G H (max)125# ANSI 250# ANSI
R S (Max)* V (min)Suct/Disch
Gauge Taps (NPT)
Drain Tap (NPT)J N P J N P
145JM10.75 23.73 27.23 21.50 25.00 0.88 12.63 4.81 7.00 24.44 5.50 4 0.75 5.88 8 0.88 9.75 1.50 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (321) (122) (178) (621) (140) (19) (149) (22) (248) (38) (121)
182JM10.75 23.73 27.23 21.50 25.00 0.88 15.31 4.81 7.00 27.13 5.50 4 0.75 5.88 8 0.88 11.75 1.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (389) (122) (178) (689) (140) (19) (149) (22) (298) (25) (121)
184JM10.75 23.73 27.23 21.50 25.00 0.88 15.31 4.81 7.00 27.13 5.50 4 0.75 5.88 8 0.88 11.75 1.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (389) (122) (178) (689) (140) (19) (149) (22) (298) (25) (121)
213JM10.75 23.73 27.23 21.50 25.00 0.88 19.25 4.81 7.00 31.06 5.50 4 0.75 5.88 8 0.88 14.00 0.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (489) (122) (178) (789) (140) (19) (149) (22) (356) (121)
215JM10.75 23.73 27.23 21.50 25.00 0.88 19.25 4.81 7.00 31.06 5.50 4 0.75 5.88 8 0.88 14.00 0.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (489) (122) (178) (789) (140) (19) (149) (22) (356) (121)
254JM10.75 23.73 27.23 21.50 25.00 0.88 24.13 5.81 7.00 36.94 5.50 4 0.75 5.88 8 0.88 17.00 0.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (613) (148) (178) (938) (140) (19) (149) (22) (432) (121)
256JM10.75 23.73 27.23 21.50 25.00 0.88 24.13 5.81 7.00 36.94 5.50 4 0.75 5.88 8 0.88 17.00 0.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (613) (148) (178) (938) (140) (19) (149) (22) (432) (121)
284JM10.75 23.73 27.23 21.50 25.00 0.88 23.63 5.81 7.00 36.44 5.50 4 0.75 5.88 8 0.88 16.13 4.63 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (600) (148) (178) (926) (140) (19) (149) (22) (410) (117) (121)
286JM10.75 23.73 27.23 21.50 25.00 0.88 25.13 5.81 7.00 37.94 5.50 4 0.75 5.88 8 0.88 16.13 4.63 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (638) (148) (178) (964) (140) (19) (149) (22) (410) (117) (121)
324JM10.75 23.73 27.23 21.50 25.00 0.88 26.00 5.81 7.00 38.81 5.50 4 0.75 5.88 8 0.88 18.75 5.38 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (660) (148) (178) (986) (140) (19) (149) (22) (476) (137) (121)
326JM10.75 23.73 27.23 21.50 25.00 0.88 26.00 5.81 7.00 38.81 5.50 4 0.75 5.88 8 0.88 18.75 5.38 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (660) (148) (178) (986) (140) (19) (149) (22) (476) (137) (121)
Dimensions are subject to change. Not to be used for construction purposes unless certified.
NOTE: For Single phase Motors add 1" to dimensions E & H.
*Dimensions are for ODP Motors. For TEFC add S dimension to dimensions E & H.
Xylem Inc. 8200 N. Austin Avenue, Morton Grove, IL 60053 Phone: (847)966-3700 Fax: (847)965-8379 www.xylem.com/bellgossett
Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. © 2019 Xylem Inc.
Series e-80 2.5x2.5x9.5C Close Coupled In-Line Centrifugal Pump B-139.10B
Flange Support Mounting DIMENSIONS - Inches (mm) STUFFING BOX
MOTOR FRAME
AHF
BOLTINGHB
ZHE BOLTING
HAHH DIA
E (max) F G H (max)125# ANSI 250# ANSI
R S (Max)* V (min)Suct/Disch
Gauge Taps (NPT)
Drain Tap (NPT)J N P J N P
145JP10.75 23.73 27.23 21.50 25.00 0.88 12.63 7.94 7.00 27.56 5.50 4 0.75 5.88 8 0.88 9.75 1.50 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (321) (202) (178) (700) (140) (19) (149) (22) (248) (38) (121)
182JP10.75 23.73 27.23 21.50 25.00 0.88 15.31 7.94 7.00 30.25 5.50 4 0.75 5.88 8 0.88 11.75 1.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (389) (202) (178) (768) (140) (19) (149) (22) (298) (25) (121)
184JP10.75 23.73 27.23 21.50 25.00 0.88 15.31 7.94 7.00 30.25 5.50 4 0.75 5.88 8 0.88 11.75 1.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (389) (202) (178) (768) (140) (19) (149) (22) (298) (25) (121)
213JP10.75 23.73 27.23 21.50 25.00 0.88 19.25 8.69 7.00 34.94 5.50 4 0.75 5.88 8 0.88 14.00 0.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (489) (221) (178) (887) (140) (19) (149) (22) (356) (121)
215JP10.75 23.73 27.23 21.50 25.00 0.88 19.25 8.69 7.00 34.94 5.50 4 0.75 5.88 8 0.88 14.00 0.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (489) (221) (178) (887) (140) (19) (149) (22) (356) (121)
254JP10.75 23.73 27.23 21.50 25.00 0.88 24.13 8.69 7.00 39.81 5.50 4 0.75 5.88 8 0.88 17.00 0.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (613) (221) (178) (1011) (140) (19) (149) (22) (432) (121)
256JP10.75 23.73 27.23 21.50 25.00 0.88 24.13 8.69 7.00 39.81 5.50 4 0.75 5.88 8 0.88 17.00 0.00 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (613) (221) (178) (1011) (140) (19) (149) (22) (432) (121)
284JP10.75 23.73 27.23 21.50 25.00 0.88 23.63 8.69 7.00 39.31 5.50 4 0.75 5.88 8 0.88 16.13 4.63 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (600) (221) (178) (999) (140) (19) (149) (22) (410) (117) (121)
286JP10.75 23.73 27.23 21.50 25.00 0.88 25.13 8.69 7.00 40.81 5.50 4 0.75 5.88 8 0.88 16.13 4.63 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (638) (221) (178) (1037) (140) (19) (149) (22) (410) (117) (121)
324JP10.75 23.73 27.23 21.50 25.00 0.88 26.00 8.69 7.00 41.69 5.50 4 0.75 5.88 8 0.88 18.75 5.38 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (660) (221) (178) (1059) (140) (19) (149) (22) (476) (137) (121)
326JP10.75 23.73 27.23 21.50 25.00 0.88 26.00 8.69 7.00 41.69 5.50 4 0.75 5.88 8 0.88 18.75 5.38 4.75 0.25 0.25
(273) (603) (692) (546) (635) (22) (660) (221) (178) (1059) (140) (19) (149) (22) (476) (137) (121)
Dimensions are subject to change. Not to be used for construction purposes unless certified.
NOTE: For Single phase Motors add 1" to dimensions E & H.
*Dimensions are for ODP Motors. For TEFC add S dimension to dimensions E & H.
Xylem Inc. 8200 N. Austin Avenue, Morton Grove, IL 60053 Phone: (847)966-3700 Fax: (847)965-8379 www.xylem.com/bellgossett
Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. © 2019 Xylem Inc.
B-139.10BSeries e-80 2.5x2.5x9.5C Close Coupled In-Line Centrifugal Pump With Integrated Technologic® Control
TECHNOLOGIC STANDARD FEATURES
CONTROL METHOD WITH INTEGRATED
TECHNOLOGIC® SENSORLESS CONTROL (ITSC)
Factory configured for sensorless operation.
CONTROL METHOD WITH INTEGRATED
TECHNOLOGIC® (IT)
Field configurable for sensor by others, building management system input, or optional sensor(s) provided.
ENCLOSURE NEMA 12 (same as IP55 & UL type 12)
POWER DISCONNECT SWITCH
Included standard. Fused Disconnect Switch optional with three phase input voltage.
HARMONIC SUPPRESSION Integrated non-saturating dual DC link reactors provide better harmonic performance than a 5% AC line reactor.
COOLING Fan-cooled through temperature controlled and easy replacement.
AMBIENT TEMPERATURE RATING
14°F to 113°F (-10°C to 45°C)
COMMUNICATION PROTOCOLS
BACnet, Modbus RTU, N2 Metasys, FLN Apogee
ANALOG INPUTS 2 configurable for either voltage (0 to 10VDC) or current(0/4 to 20mA)
ANALOG OUTPUTS 1 (0/4 to 20mA) up to 500 ohm load accurate to 1% of full scale
DIGITAL INPUTS 4 (0 to 24VDC), NPN or PNP, 0 to 24VDC, on 5 msec scan interval, Up to 2 can be configured as pulse inputs.
DIGITAL OUTPUTS 2 (0 to 24VDC), 40mA max current, configurable as pulse outputs.
RELAY OUTPUTS 2 programmable, 240VAC or 400VAC up to 2 A
MINIMUM CONTROL HEAD _______ ft (default set to 40% of design head if not unknown)
Xylem Inc. 8200 N. Austin Avenue, Morton Grove, IL 60053 Phone: (847)966-3700 Fax: (847)965-8379 www.xylem.com/bellgossett
Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. © 2019 Xylem Inc.
B-139.10BSeries e-80 2.5x2.5x9.5C Close Coupled In-Line Centrifugal Pump With Integrated Technologic® ControlDIMENSIONS - Inches (mm) STANDARD SEAL
MOTOR FRAME
VFD Rv Zv W Hv Xv
145JM
A511.78 12.31 9.50 30.14 1.19
(299) (313) (241) (766) (30)
B114.07 13.91 9.50 32.49 2.79
(357) (353) (241) (825) (71)
182JM
A512.78 13.19 9.50 29.28 0.69
(325) (335) (241) (744) (17)
B115.07 14.79 9.50 30.28 2.29
(383) (376) (241) (769) (58)
184JM
A512.78 13.19 9.50 29.28 0.69
(325) (335) (241) (744) (17)
B115.07 14.79 9.50 30.28 2.29
(383) (376) (241) (769) (58)
213JM
A513.53 13.83 9.50 32.70 0.31
(344) (351) (241) (831) (8)
B115.84 15.84 9.50 34.30 0.88
(402) (402) (241) (871) (22)
B215.84 15.84 9.50 40.04 0.88
(402) (402) (241) (1017) (22)
215JM
A513.53 13.83 9.50 31.23 0.31
(344) (351) (241) (793) (8)
B115.84 15.84 9.50 32.77 0.88
(402) (402) (241) (832) (22)
B215.84 15.84 9.50 38.51 0.88
(402) (402) (241) (978) (22)
C117.81 19.04 12.10 40.53 4.08
(452) (484) (307) (1029) (104)
254JM 0.00 0.00 0.00 0.00 0.00 0.00
256JM
B116.83 16.70 9.50 38.38 1.38
(427) (424) (241) (975) (35)
B216.83 16.70 9.50 42.84 1.38
(427) (424) (241) (1088) (35)
C118.83 18.97 12.09 43.72 3.28
(478) (482) (307) (1110) (83)
C219.61 (21) 14.59 48.38 5.58
(498) (540) (371) (1229) (142)
284JM
B117.58 17.36 9.50 37.75 1.75
(446) (441) (241) (959) (44)
B217.58 17.36 9.50 42.20 1.75
(446) (441) (241) (1072) (44)
C119.58 19.63 12.09 44.61 3.66
(497) (498) (307) (1133) (93)
C220.36 (22) 14.59 47.76 5.96
(517) (557) (371) (1213) (151)
286JM
B217.58 17.36 9.50 43.70 1.75
(446) (441) (241) (1110) (44)
C119.58 19.63 12.09 46.11 3.66
(497) (498) (307) (1171) (93)
C220.36 (22) 14.59 49.26 5.96
(517) (557) (371) (1251) (151)
324JM
B218.58 18.22 9.50 43.05 2.25
(472) (463) (241) (1093) (57)
C120.58 20.48 12.09 43.39 4.16
(523) (520) (307) (1102) (106)
C221.58 21.95 14.59 47.95 5.69
(548) (558) (371) (1218) (144)
326JM
C120.58 20.48 12.09 43.39 4.16
(523) (520) (307) (1102) (106)
C221.58 21.95 14.59 47.95 5.69
(548) (558) (371) (1218) (144)
STUFFING BOX
MOTOR FRAME
VFD Rv Zv W Hv Xv
145JP
A511.78 12.31 9.50 33.27 1.19
(299) (313) (241) (845) (30)
B114.07 13.91 9.50 35.62 2.79
(357) (353) (241) (905) (71)
182JP
A512.78 13.19 9.50 32.41 0.69
(325) (335) (241) (823) (17)
B115.07 14.79 9.50 33.41 2.29
(383) (376) (241) (849) (58)
184JP
A512.78 13.19 9.50 32.41 0.69
(325) (335) (241) (823) (17)
B115.07 14.79 9.50 33.41 2.29
(383) (376) (241) (849) (58)
213JP
A513.53 13.83 9.50 36.58 0.31
(344) (351) (241) (929) (8)
B115.84 15.84 9.50 38.17 0.88
(402) (402) (241) (970) (22)
B215.84 15.84 9.50 43.91 2.48
(402) (402) (241) (1115) (63)
215JP
A513.53 13.83 9.50 35.11 0.31
(344) (351) (241) (892) (8)
B115.84 15.84 9.50 36.64 0.88
(402) (402) (241) (931) (22)
B215.84 15.84 9.50 42.38 0.88
(402) (402) (241) (1076) (22)
C117.81 19.04 12.10 44.40 4.08
(452) (484) (307) (1128) (104)
254JP 0.00 0.00 0.00 0.00 0.00 0.00
256JP
B116.83 16.70 9.50 41.25 1.38
(427) (424) (241) (1048) (35)
B216.83 16.70 9.50 45.71 1.38
(427) (424) (241) (1161) (35)
C118.83 18.97 12.09 46.59 3.28
(478) (482) (307) (1183) (83)
C219.61 (21) 14.59 51.25 5.58
(498) (540) (371) (1302) (142)
284JP
B117.58 17.36 9.50 40.63 1.75
(446) (441) (241) (1032) (44)
B217.58 17.36 9.50 45.08 1.75
(446) (441) (241) (1145) (44)
C119.58 19.63 12.09 47.48 3.66
(497) (498) (307) (1206) (93)
C220.36 (22) 14.59 50.63 5.96
(517) (557) (371) (1286) (151)
286JP
B217.58 17.36 9.50 46.58 1.75
(446) (441) (241) (1183) (44)
C119.58 19.63 12.09 48.98 3.66
(497) (498) (307) (1244) (93)
C220.36 (22) 14.59 52.13 5.96
(517) (557) (371) (1324) (151)
324JP
B218.58 18.22 9.50 45.92 2.25
(472) (463) (241) (1166) (57)
C120.58 20.48 12.09 46.27 4.16
(523) (520) (307) (1175) (106)
C221.58 21.95 14.59 50.83 5.69
(548) (558) (371) (1291) (144)
326JP
C120.58 20.48 12.09 46.27 4.16
(523) (520) (307) (1175) (106)
C221.58 21.95 14.59 50.83 5.69
(548) (558) (371) (1291) (144)
NOTE: Drives with single phase input have three phase output and include three phase motors. Kv=2 (50)