24
Series CA9 Contactors The modern contactor for industrial applications up to 630kW (@415V AC) NHP Electrical Engineering Products 1300 NHP NHP 0800 NHP NHP nhp.com.au nhp-nz.com NZ AUS MOTOR CONTROL AND DRIVES

Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

  • Upload
    others

  • View
    29

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

Series CA9 ContactorsThe modern contactor for industrial applications up to 630kW (@415V AC)

NHP Electrical Engineering Products 1300 NHP NHP0800 NHP NHP

nhp.com.aunhp-nz.comNZ

AUS

MOTOR CONTROL AND DRIVES

Page 2: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

THE NHP DIFFERENCE

WHAT MAKES NHP DIFFERENT FROM OUR COMPETITORS ARE THESE THREE DISTINCT PROMISES.

SINCE 1968, NHP HAS BEEN AN INDEPENDENT AUSTRALIAN OWNED COMPANY PASSIONATE ABOUT PROVIDING OUR CUSTOMERS WITH LOCAL CHOICE POWERED BY GLOBAL PARTNERS.

With 50 years of electrical and engineering industry excellence and over 45 locations across Australia and New Zealand, at NHP it is our local people and footprint that helps us understand your specific project needs, no matter how big or small.

While we go to market with over 15,000 stocked items, we are much more than a product supplier. Together with our extensive network of global partners, we offer choice in product, choice in technology, choice in service, choice in support and ultimately choice in how you deal with us – whether that be in person or online, where and when you need us.

This enables NHP to customise integrated solutions and bring to life smart and secure technologies that automate production, control power and manage energy.

When it comes to finding a local partner with a global network for your next project, choosing NHP will unlock a world of expertise, knowledge and experience across electrical and automation products, systems and solutions.

THE POWER OF CHOICE

C

M

Y

CM

MY

CY

CMY

K

NHP_MessagingBanner ALL 950X1900 .pdf 1 1/08/2017 1:01 PM

THE POWER OF LOCAL

C

M

Y

CM

MY

CY

CMY

K

NHP_MessagingBanner ALL 950X1900 .pdf 2 1/08/2017 1:01 PM

THE POWER OF GLOBAL PARTNERS

C

M

Y

CM

MY

CY

CMY

K

NHP_MessagingBanner ALL 950X1900 .pdf 3 1/08/2017 1:01 PM

In your local community, city and industry, we understand your specific project needs.

Choice in product, technology, service, and support enabling

you to customise and push boundaries.

With a global network of suppliers, we bring

the world’s best products and knowledge to your

doorstep.

Page 3: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

3

Product Line Overview 4

CA9 Contactors Overview 5

CA9 Catalogue Scheme 6

CA9 Product Selection 7

CEP7-EE Electronic Overload Relay 8

Accessories for CA9 Contactors 9

Renewal Parts 12

Contactor Cross Reference 14

Technical Information

General Data 16

Dimensions 17

Why NHP 23

Contents Page

Page 4: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

4

Contactors Safety Contactors

Series CA8 CA7 CA9 CAS7

AC-1 Ith Current Rating 12A 97A 2650A 97A

AC-3 Current Rating 5…12A 9…97A 116...1060A 9...97A

Features

• Mini-contactors• Uniform panel mounting

dimensions• Panel mounting or

mounting on 35mm DIN rail

• AC or DC coil control• Made of environmentally

friendly materials

• Panel mounting or mounting on 35mm DIN rail

• AC or DC coil control• Reversible coil terminals

(line or load side)• Common accessories• Made of environmentally

friendly materials

• Panel mounting• 116...370-(EI)

AC/DC electronic coil or optional with PLC interface

• 400...2650-EI AC/DC with PLC interface

• Made of environmentally friendly materials

• Mechanically linked auxiliary contacts

• Front-mounted auxiliary contacts: - Permanently fixed - Protective cover to prevent manual operation - Red contact housing for easy identification

• AC and DC operating coils• SUVA third-party

certification

Contacts

3 main poles with internal N/O or N/C auxiliary contact,

or 4 main polesOptional front-mounted

2– or 4- pole external auxiliary contact block

3 main poles with internal N/O or N/C auxiliary

contact or 4 main polesOptional front–

or side-mounted1-, 2- or 4-pole external auxiliary contact block

3 main poles with 2 auxiliary contacts (1N/O and 1N/C)

Optional side-mounted 2-pole external auxiliary

contact block

3 main poles with N/C mechanically linked or

mirror feedback contacts

Coil Voltages AC = 24...600V, 50/60 HzDC = 12...250V

AC = 12...600V, 50/60HzDC = 9...250V 24...500V 50/60 Hz / DC AC = 12...600V, 50/60Hz

DC = 12...250V

Optional Overload Relays Bi-metallic (CT8) Electronic (CEP7) or bi-metallic (CT7N) Electronic (CEP7) Electronic (CEP7) or

bi-metallic (CT7N)

Optional Accessories

• Front-mount auxiliary contacts

• Surge suppressors• Electronic timers• Mechanical interlocks

• Front or side-mount auxiliary contacts

• Surge suppressors• Electronic or pneumatic

timers• Mechanical interlocks• Mechanical latches

• Side-mount auxiliary contacts

• Mechanical interlocks• Terminal lugs• Terminal shields• Connecting bars

• Side-mount auxiliary contacts

• Surge suppressors• Electronic timers• Mechanical interlocks

Page 5: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

5

CA9 Contactors OverviewSprecher+Schuh’s CA9 contactor line combines the simple function of our popular CA7 series with the rugged performance demanded in this wide kilowatt range. CA9 contactors offer a smaller footprint than traditional contactors in this size class.

A broad selection for your motor starting applicationsThe CA9 range consists of sixteen contactors in six frame sizes covering motors from 55 to 630kW at 415V AC and from 55 to 600kW at 1000V AC. This line is ideally suited for demanding applications such as steel mills, rock quarries, mines or for any application where a sturdy, durable contactor is needed.

Rugged and reliableCA9 contactors conform to IEC/EN 60947 and can be operated at rated voltages up to 1000V AC. High thermal and switching capacities guarantee reliable operation and long life.

Arc quenching extends contact lifeAll CA9 contactors are designed with sophisticated arc quenching techniques that extinguish damaging breaking arcs quickly. This is accomplished by guiding the arc away from the contacts and into “arc chambers” which are built-in to every CA9 cover.

Safety firstCA9 arc chambers are completely enclosed (without arc exhaust vents), offering the best protection against hot arcing gases. A large safety distance in front of the contactor is unnecessary. CA9 contactors are also designed so that operation is impossible if the arc chambers are removed. Conversely, once the contactor is energised, the arc chambers cannot be removed.

Electronic coils offer many advantagesBehind the attractive outward appearance of the CA9 contactor are advanced engineering solutions that offer convenience and savings. The entire line is equipped with an electronically controlled coil that reduces pick-up currents by 80% on average. Holding current is also reduced.

Optimum protectionCA9 contactors and Terasaki MCCBs are the ideal starter combination for motor starting applications, including Type 2 co-ordination for IE3 premium efficiency motors.

90mm 105mm 140mm 186mm 210mm 438mm

860A1060A2050A2650A

580A750A

1260A

400A460A

265A305A 370A

190A205A

116A146A

Page 6: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

6

CA9 Catalogue SchemeThis catalogue number chart provides a general guide to creating a CA9 catalogue number to match your application. Not all possible combinations are valid. Consult NHP for product selection and safety contactor options.

CONTACTOR SIZE

AC-3, 400 / 415V CA9-...

116A 116

146A 146

190A 190

205A 205

265A 265

305A 305

370A 370

400A 400

460A 460

580A 580

750A 750

860A 860

1060A 1060

1260A 1) 1260

2050A 1) 2050

2650A 1) 2650

PLC INTERFACE 2)

Type Ref No.

Without PLC interface Blank

With PLC interface EI

AUXILIARY CONTACT CONFIGURATION

Std. Aux. Contacts Ref No.

N/O N/C

1 1 11

OPTIONS

Connections Sizes Ref No.

Bar Connections 116…2650 blank

With Built-in Lugs 116…146 L

CONTROL VOLTAGE

V Coil Code Sizes

24-60V AC/DC 24W 116…370

48-130V AC/DC 48W 116…370

100-250V AC/DC 120W 116…370

250-500V AC/DC 480W 116…370

24-60V DC (w/ PLC Input) 24W 400…750, 1260

48-130V AC/DC (w/ PLC Input) 48W 400…750, 1260

100-250V AC/DC (w/ PLC Input) 120W 116…2650

250-500V AC/DC (w/ PLC Input) 480W 116…750, 1260

SERIES

CA9 Contactor CA9

CA9 116 EI 11 120W L

A

CA9

Con

tact

ors

A91visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Non-Reversing, Three Pole Contactors With AC/DC Coil, Series CA9 (Open type only) ➊➌

Contactors - AC/DC CoilThree Pole - Series CA9

CA9-_-EI coils are electronically controlled coils with the following characteristics:• Ability to connect directly to a low level signal source such as a PLC ~15VDC

(6mA) to 33VDC (20mA)• Very low pull-in and holding current for contactors in this size class• Threshold voltages for pull-in and drop-out are very precisely defined, eliminating

“chattering”• Supply voltage dips are bridged without extra equipment

CA9-860-EI contactor

Ie [A]Ratings for Switching AC Motors (AC2 / AC3 ) Auxiliary

Contacts per Contactor

Open Type

kW (50 Hz) UL/CSA HP (60 Hz)

AC-3 AC-1220- 240V

380- 400V

3 Ø

(400V) (690V) 415V 440V 500V 690V 1000V 200V 230V 460V 575V NO NC Catalog Number Price

116 160 37 55 55 75 75 55 ~ 30 40 75 100 1 1CA9-116-11-✱-L ➋

CA9-116-EI-11-✱-L ➋

760810

146 225 45 75 75 90 90 90 75 40 50 100 125 1 1CA9-146-11-✱-L ➋

CA9-146-EI-11-✱-L ➋

913963

190 275 55 90 90 110 90 132 110 50 60 125 150 1 1CA9-190-11-✱CA9-190-EI-11-✱

15301580

205 350 55 110 110 132 110 160 132 60 75 150 200 1 1CA9-205-11-✱CA9-205-EI-11-✱

17401790

265 400 75 132 132 160 160 200 132 75 100 200 250 1 1CA9-265-11-✱CA9-265-EI-11-✱

18901940

305 500 90 160 160 160 200 250 132 100 125 250 300 1 1CA9-305-11-✱CA9-305-EI-11-✱

21202170

370 600 110 200 200 200 220 315 132 125 150 300 350 1 1CA9-370-11-✱CA9-370-EI-11-✱

28302880

400 600 110 200 220 220 250 315 220 125 150 350 400 1 1 CA9-400-EI-11-✱ 4150

460 700 132 250 250 250 315 355 280 150 200 400 500 1 1 CA9-460-EI-11-✱ 5250

480 800 160 315 355 355 400 500 355 200 250 500 600 1 1 CA9-580-EI-11-✱ 7510

750 1050 220 400 425 450 530 600 400 250 300 600 700 1 1 CA9-750-EI-11-✱ 11000

860 1350 250 475 500 560 560 800 555 ~ 400 800 1000 1 1 CA9-860-EI-11-✱ 17000

1060 1650 315 560 630 710 710 1000 600 ~ 450 900 1150 1 1 CA9-1060-EI-11-✱ 19300

~ 1260 ~ ~ ~ ~ ~ ~ ~ ~ ~ 1 1 CA9-1260-EI-11-✱ 15900

~ 2050 ~ ~ ~ ~ ~ ~ ~ ~ ~ 1 1 CA9-2050-EI-11-✱ 22600

~ 2650 ~ ~ ~ ~ ~ ~ ~ ~ ~ 1 1 CA9-2650-EI-11-✱ 25200

Specify Catalog Number

Replace (✱) with Coil Code See Coil Codeson this page

Ordering Instructions ➊ “-EI” designates contactor coil with PLC input. ➋ CA9-116(-EI)…146(-EI) include terminal lugs. To order with terminal bolts remove

the letter “-L” at the end of the catalog number. For example CA9-116(-EI)-✱-11-L becomes CA9-116(-EI)-✱-11.

➌ For UL/CSA Elevator duty rating, consult Technical Information on page A103.➍ Coil is rated 24V…60V DC only.

Coil Codes Electronic Coils V 24-60V 48-130V 100-250V 250-500VCA9-116…370 AC/DC 24W 48W 120W 480W

CA9-116-EI…370-EI

AC/DC with PLC Input

~ ~ 120W 480WCA9-400-EI…750-EI 24W ➍ 48W 120W 480W

CA9-860-EI…1060-EI ~ ~ 120W ~CA9-1260-EI 24W ➍ 48W 120W 480W

CA9-2050-EI…2650-EI ~ ~ 120W ~

CA9-116 contactor

CA9-400-EI contactor

Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for ordering information.

Supply voltage

ContactorA1 A2

24V0V

COMMON

OFF_N

ONX5

1

2

3

ON

OFFPLC Interface “EI” connection

Notes: 1) AC-1 only 2) “-EI” designates contactor coil with PLC input. Selections CA9-116...370 with “EI” requires use of control logic terminals 1,2,3. CA9-400 contactors and larger include an integral switch to select use of “EI”.

PLC interface 2)CA9-_-EI coils are electronically controlled coils with the following characteristics:

• Ability to connect directly to a low level signal source such as a PLC ~15V DC (6mA) to 33V DC (20mA)

• Very low pull-in and holding current for contactors in this size class

• Threshold voltages for pull-in and drop-out are very precisely defined, eliminating “chattering”

• Supply voltage dips are bridged without extra equipment

Page 7: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

7

CA9 Product selectionThree Pole Contactors with AC/DC coil ¹)

Rated operationalcurrent Ie (A)

Ratings for switching AC motors (AC-3)

Auxiliary contacts per contactor

AC-3 (400/415V) 60º C

AC-1 (690V)40º C

kW (50Hz) StandardMax.

400V 415V 690V 1000V N/O N/C Catalogue No.

116  160  55  55  63  55  1  1  8 CA9-116-11-U 2) 

CA9-116-EI-11-U 2)

146  225  75  75  90  75  1  1  8 CA9-146-11-U 

CA9-146-EI-11-U 

190  275  90  90  132  110  1  1  8 CA9-190-11-U 

CA9-190-EI-11-U 

205  350  110  110  160  132  1  1  8 CA9-205-11-U 

CA9-205-EI-11-U 

265  400  132  132  200  132  1  1  8 CA9-265-11-U 

CA9-265-EI-11-U 

305  500  160 160 

250  132  1  1  8 CA9-305-11-U 

CA9-305-EI-11-U 

370  600  200  200  315  132  1  1  8 CA9-370-11-U 

CA9-370-EI-11-U 

400  600  200  220  315  220  1  1  8  CA9-400-EI-11-U 

460  700  250  250  355  280  1  1  8  CA9-460-EI-11-U 

580  800  315  355  500  355  1  1  8  CA9-580-EI-11-U 

750  1050  400  425  600  400  1  1  8  CA9-750-EI-11-U 

860  1350  475  500  800  555  1  1  8  CA9-860-EI-11-U 

1060  1650  560  630  1000  600  1  1  8  CA9-1060-EI-11-U 

-  1260  -  -  -  -  1  1  8  CA9-1260-EI-11-U 

-  2050  -  -  -  -  1  1  8  CA9-2050-EI-11-U 

-  2650  -  -  -  1  1  8  CA9-2650-EI-11-U 

UCoil voltage codes

The Catalogue No. Listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue No. (e.g., CA9-116-11-120W)

Electronic Coils V 24…60V 48…130V 100…250V 250…500V

CA9-116…370 AC/DC 24W 48W 120W 480W

CA9-116-EI…370-EI

AC/DC with PLC input

- - 120W 480W

CA9-400-EI…750-EI 24W 3) 48W 120W 480W

CA9-860-EI…1060-EI - - 120W -

CA9-1260-EI 24W 3) 48W 120W 480W

CA9-2050-EI…2650-EI - - 120W -

Notes: 1) “-EI” designates contactor coil with PLC input. Selections CA9-116...370 with “EI” requires use of control logic on terminals 1, 2, 3. CA9-400 contactors and larger include an integral switch to select use of “EI” 2) To order with built-in terminal lugs, add “-L” to the end of the Catalogue No. For example CA9-116(-EI)-U-11 becomes

CA9-116(-EI)-U-11-L 3) Coil is rated 24…60V DC only

CA9-116 Contactor

CA9-400-EI Contactor

CA9-860-EI Contactor

Page 8: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

8

Overload relay 1) 2)

Directly Mounts to Contactor… 3) CT Ratio Adjustment range (A) Catalogue No.

CA9-116...146(-EI) 150:5 30...150 CEP7-EEHJ

CA9-190...205(-EI) 200:5 40...200 CEP7-EEJJ

Notes: 1) Three phase CEP7 units are only designed for three phase applications 2) The reset time of a CEP7 set in the automatic mode is approximately 120 seconds 3) This reference is not intended to be a guide for selecting contactors. Size overload relays using the full load current of the motor 4) Kit includes electronic overload relay, panel adaptor and three current transformers 5) For 1000V AC applications, 1000 volt insulated cable is required to pass through the CT aperture

CEP7-EE Electronic Overload RelayThe CEP7-EE solid-state overload relays offer superior motor protection with advanced features such as:

• Selectable trip class (10, 15, 20 and 30) and field-installable modules

• Lower energy consumption compared to bi-metallic overload relays

• A wide current adjustment range of 5:1

• Robust, self-powered design with mechanical and electrical mounting

• Automatic or Manual Reset for three phase applications

• Direct mounting to CA9 contactors up to 200A

• Full range of accessories available, contact NHP

Current Transformer Kits 4) 5)

Above 200A there are no CEP7 overloads for direct mounting to CA9 contactors. Use overload relay Cat. No.CEP7-EECB, mounting bracket Cat. No. CEP7-EPB and separate 5P10-5A current transformers. Alternatively, current transformer kits can be used.

For use with Contactor CT Ratio Adjustment Range (A) Kit Catalogue No.

CA9-265...400 400:5 80...400 CT-KIT-400A

CA9-460...580 600:5 120...600 CT-KIT-600A

CA9-750...860 800:5 160...800 CT-KIT-800A

• Rated operation voltage Ue = 690V AC. For 1000V AC applications, a CT option is required

Page 9: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

9

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

Auxiliary Contact Blocks

Description N/O N/CContactArrangement For use with... Catalogue No.

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1

CA9-116…370Inside left or right

CA9-S1-11

CA9-400…2650Inside left or right

CA9-S3-11

1 1

CA9-116…370Outside left or right

CA9-S2-11

CA9-400…2650Outside left or right

CA9-S4-11

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0

CA9-116…370Inside left or right

CA9-S1-B10 1)

CA9-400…2650Inside left or right

CA9-S3-B10 1)

0 1

CA9-116…370Inside left or right

CA9-S1-B01 1)

CA9-400…2650Inside left or right

CA9-S3-B01 1)

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

Note: 1) Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.

Positioning of auxilary contactUp to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor.As standard, one auxiliary contact block (1 N/O and 1 N/C) is mounted at the factory (inside left position).

Accessories for CA9 Contactors

Page 10: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

10

Terminal Lugs

Description Wire sizes For use with… Catalogue No.

Order 1 Pkg for 3 lugs

• Includes 1 set of 3 lugs for use on either Line or Load Side• Order qty of 2 for both

2x16mm² to 150mm² CA9-190(-EI)…205(-EI) CA9-TL205

2x 25mm² to 185mm² CA9-265(-EI)…370(-EI) CA9-TL370

2x 25mm² to 240mm² CA9-265(-EI)…370(-EI) CA9-TL370B

3x 70mm² to 240mm² CA9-400-EI…460-EI CA9-TL580

2x 70mm² to 240mm² CA9-580-EI…750-EI, CA9-1260-EI CA9-TL750

4x 120mm² to 240mm² CA9-860-EI CA9-TL860

4x 70mm² to 300mm² CA9-1060-EI CA9-TL1060

6x 70mm² to 300mm² CA9-1060-EI CA9-TL1060B

Terminal Enlargements

Description For use with… Catalogue No.

• Enlargement pieces designed to increase the width of the contactor terminal pads in order to allow larger connections to be mounted

CA9-116(-EI)…146(-EI) CA9-TE146

CA9-190(-EI)…205(-EI) CA9-TE205

CA9-265(-EI)…370(-EI) CA9-TE370

CA9-400-EI…460-EI CA9-TE460

CA9-580-EI…750-EI CA9-TE750

CA9-1260-EI CA9-TE1260

Accessories for CA9 Contactors

Mechanical Interlocks

Description For use with… Catalogue No.

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00

CA9-400…750,CA9-1260 1)

CA9-M2-00

CA9-860…1060,CA9-2050…2650 2)

CA9-M3-00

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146to CA9-190…205

CA9-M4-00

CA9-190…205to CA9-265…370

CA9-M5-00

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

A

CA9

Con

tact

ors

A94visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

See page A109 for terminal wire ranges.

Terminal Lugs and Accessories

Lug or Accessory Connection Wire Sizes For use with…Catalog Number

Price

Order 1 Pkg for 2 kits

Terminal Lug Kit - • Standard for CA9-116-_-L…146-_-L• Includes 2 sets, one for Line side and

one for Load Side

2 x 6 AWG…3/0 AWG CA9-116(-EI)…146(-EI) CA9-CL146 26

Order 1 Pkg for 3 lugs

Terminal Lugs• Includes 1 set of 3 lugs for use on

either Line or Load Side. • Order qty of 2 for both.

6 AWG…300 MCM CA9-190(-EI)…205(-EI) CA9-TL205 78

4 AWG…400 MCM CA9-265(-EI)…370(-EI) CA9-TL370 116

2 x 4 AWG…500 MCM CA9-265(-EI)…370(-EI) CA9-TL370B 170

3 x 2/0 AWG…500 MCM CA9-400-EI…460-EI CA9-TL580 300

2 x 2/0 AWG…500 MCM CA9-580-EI…750-EI, CA9-1260-EI CA9-TL750 434

4 x 4/0 AWG…500 MCM CA9-860-EI CA9-TL860 578

4 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060 821

6 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060B 1098

Terminal Enlargements• Enlargement pieces designed to increase the width of the contactor

terminal pads in order to allow larger connections to be mounted

CA9-116(-EI)…146(-EI) CA9-TE146 94

CA9-190(-EI)…205(-EI) CA9-TE205 119

CA9-265(-EI)…370(-EI) CA9-TE370 184

CA9-400-EI…460-EI CA9-TE460 236

CA9-580-EI…750-EI CA9-TE750 315

CA9-1260-EI CA9-TE1260 418

Terminal Extensions• Extension pieces designed to extend the main terminals of contactors

for combined mounting of contactors and connection sets

CA9-116(-EI)…146(-EI) CA9-TX146 67

CA9-190(-EI)…205(-EI) CA9-TX205 82

CA9-265(-EI)…370(-EI) CA9-TX370 149

CA9-400-EI…460-EI CA9-TX460 161

CA9-580-EI…750-EI CA9-TX750 220

Terminal Shrouds

Accessory Description For use with... Catalog Number Price

For contactors with Terminal Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-190(-EI)…205(-EI) CA9-TS205C 57

CA9-265(-EI)…370(-EI) CA9-TS370C 57

CA9-400-EI…460-EI CA9-TS460C 85

CA9-580-EI…750-EI, 1260-EI CA9-TS750C 101

For contactors with Compression Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-116(-EI)…146(-EI) CA9-TS146L 59

CA9-190(-EI)…205(-EI) CA9-TS205L 59

CA9-265(-EI)…370(-EI) CA9-TS370L 59

CA9-400-EI…460-EI CA9-TS460L 87

CA9-580-EI…750-EI CA9-TS750L 103For IP20 protection between contactor and overload relay on a non-reversing starter

CAT9-116(-EI)…146(-EI) CA9-TC146 42CAT9-190(-EI)…205(-EI) CA9-TC205 54

For IP20 protection between contactor and overload relay on a reversing starter

CAUT9-116(-EI)…146(-EI) CA9-TCR146 74

CAUT9-190(-EI)…205(-EI) CA9-TCR205 84

A

CA9

Con

tact

ors

A94visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

See page A109 for terminal wire ranges.

Terminal Lugs and Accessories

Lug or Accessory Connection Wire Sizes For use with…Catalog Number

Price

Order 1 Pkg for 2 kits

Terminal Lug Kit - • Standard for CA9-116-_-L…146-_-L• Includes 2 sets, one for Line side and

one for Load Side

2 x 6 AWG…3/0 AWG CA9-116(-EI)…146(-EI) CA9-CL146 26

Order 1 Pkg for 3 lugs

Terminal Lugs• Includes 1 set of 3 lugs for use on

either Line or Load Side. • Order qty of 2 for both.

6 AWG…300 MCM CA9-190(-EI)…205(-EI) CA9-TL205 78

4 AWG…400 MCM CA9-265(-EI)…370(-EI) CA9-TL370 116

2 x 4 AWG…500 MCM CA9-265(-EI)…370(-EI) CA9-TL370B 170

3 x 2/0 AWG…500 MCM CA9-400-EI…460-EI CA9-TL580 300

2 x 2/0 AWG…500 MCM CA9-580-EI…750-EI, CA9-1260-EI CA9-TL750 434

4 x 4/0 AWG…500 MCM CA9-860-EI CA9-TL860 578

4 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060 821

6 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060B 1098

Terminal Enlargements• Enlargement pieces designed to increase the width of the contactor

terminal pads in order to allow larger connections to be mounted

CA9-116(-EI)…146(-EI) CA9-TE146 94

CA9-190(-EI)…205(-EI) CA9-TE205 119

CA9-265(-EI)…370(-EI) CA9-TE370 184

CA9-400-EI…460-EI CA9-TE460 236

CA9-580-EI…750-EI CA9-TE750 315

CA9-1260-EI CA9-TE1260 418

Terminal Extensions• Extension pieces designed to extend the main terminals of contactors

for combined mounting of contactors and connection sets

CA9-116(-EI)…146(-EI) CA9-TX146 67

CA9-190(-EI)…205(-EI) CA9-TX205 82

CA9-265(-EI)…370(-EI) CA9-TX370 149

CA9-400-EI…460-EI CA9-TX460 161

CA9-580-EI…750-EI CA9-TX750 220

Terminal Shrouds

Accessory Description For use with... Catalog Number Price

For contactors with Terminal Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-190(-EI)…205(-EI) CA9-TS205C 57

CA9-265(-EI)…370(-EI) CA9-TS370C 57

CA9-400-EI…460-EI CA9-TS460C 85

CA9-580-EI…750-EI, 1260-EI CA9-TS750C 101

For contactors with Compression Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-116(-EI)…146(-EI) CA9-TS146L 59

CA9-190(-EI)…205(-EI) CA9-TS205L 59

CA9-265(-EI)…370(-EI) CA9-TS370L 59

CA9-400-EI…460-EI CA9-TS460L 87

CA9-580-EI…750-EI CA9-TS750L 103For IP20 protection between contactor and overload relay on a non-reversing starter

CAT9-116(-EI)…146(-EI) CA9-TC146 42CAT9-190(-EI)…205(-EI) CA9-TC205 54

For IP20 protection between contactor and overload relay on a reversing starter

CAUT9-116(-EI)…146(-EI) CA9-TCR146 74

CAUT9-190(-EI)…205(-EI) CA9-TCR205 84

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

Note: 1) Mounting plate ordered separately, contact NHP 2) Mounting plate included

Terminal Lug Kit

Description Wire sizes For use with… Catalogue No.

Order 1 Pkg for 2 kits

• Standard for CA9-116-_-L…146-_-L• Includes 2 sets, one for Line side and one for Load Side

2x 16mm² to 70mm² CA9-116(-EI)…146(-EI) CA9-CL146

A

CA9

Con

tact

ors

A94visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

See page A109 for terminal wire ranges.

Terminal Lugs and Accessories

Lug or Accessory Connection Wire Sizes For use with…Catalog Number

Price

Order 1 Pkg for 2 kits

Terminal Lug Kit - • Standard for CA9-116-_-L…146-_-L• Includes 2 sets, one for Line side and

one for Load Side

2 x 6 AWG…3/0 AWG CA9-116(-EI)…146(-EI) CA9-CL146 26

Order 1 Pkg for 3 lugs

Terminal Lugs• Includes 1 set of 3 lugs for use on

either Line or Load Side. • Order qty of 2 for both.

6 AWG…300 MCM CA9-190(-EI)…205(-EI) CA9-TL205 78

4 AWG…400 MCM CA9-265(-EI)…370(-EI) CA9-TL370 116

2 x 4 AWG…500 MCM CA9-265(-EI)…370(-EI) CA9-TL370B 170

3 x 2/0 AWG…500 MCM CA9-400-EI…460-EI CA9-TL580 300

2 x 2/0 AWG…500 MCM CA9-580-EI…750-EI, CA9-1260-EI CA9-TL750 434

4 x 4/0 AWG…500 MCM CA9-860-EI CA9-TL860 578

4 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060 821

6 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060B 1098

Terminal Enlargements• Enlargement pieces designed to increase the width of the contactor

terminal pads in order to allow larger connections to be mounted

CA9-116(-EI)…146(-EI) CA9-TE146 94

CA9-190(-EI)…205(-EI) CA9-TE205 119

CA9-265(-EI)…370(-EI) CA9-TE370 184

CA9-400-EI…460-EI CA9-TE460 236

CA9-580-EI…750-EI CA9-TE750 315

CA9-1260-EI CA9-TE1260 418

Terminal Extensions• Extension pieces designed to extend the main terminals of contactors

for combined mounting of contactors and connection sets

CA9-116(-EI)…146(-EI) CA9-TX146 67

CA9-190(-EI)…205(-EI) CA9-TX205 82

CA9-265(-EI)…370(-EI) CA9-TX370 149

CA9-400-EI…460-EI CA9-TX460 161

CA9-580-EI…750-EI CA9-TX750 220

Terminal Shrouds

Accessory Description For use with... Catalog Number Price

For contactors with Terminal Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-190(-EI)…205(-EI) CA9-TS205C 57

CA9-265(-EI)…370(-EI) CA9-TS370C 57

CA9-400-EI…460-EI CA9-TS460C 85

CA9-580-EI…750-EI, 1260-EI CA9-TS750C 101

For contactors with Compression Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-116(-EI)…146(-EI) CA9-TS146L 59

CA9-190(-EI)…205(-EI) CA9-TS205L 59

CA9-265(-EI)…370(-EI) CA9-TS370L 59

CA9-400-EI…460-EI CA9-TS460L 87

CA9-580-EI…750-EI CA9-TS750L 103For IP20 protection between contactor and overload relay on a non-reversing starter

CAT9-116(-EI)…146(-EI) CA9-TC146 42CAT9-190(-EI)…205(-EI) CA9-TC205 54

For IP20 protection between contactor and overload relay on a reversing starter

CAUT9-116(-EI)…146(-EI) CA9-TCR146 74

CAUT9-190(-EI)…205(-EI) CA9-TCR205 84

A

CA9

Con

tact

ors

A93visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

➊ Contact blocks cannot be mounted on the outside of CA9-S1-B* or CA9-S3-B*.➋ Mounting plate ordered separately.➌ Mounting plate included.

Auxiliary Contact Blocks Auxiliary

Contact Blocks Description NO NCContact

Arrangement For use with...Catalog Number Price

Auxiliary Contact Block for Side Mounting• 2-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Low power switching down to 24V 50mA

1 1NO 14

NO 13

NC 22

NC 21NO 44 NC 32

NC 31NO 43

CA9-116…370Inside left or right

CA9-S1-11 19.50

CA9-400…2650Inside left or right

CA9-S3-11 19.50

1 1NO 54

NO 53

NC 62

NC 61NO 84 NC 72

NC 71NO 83

CA9-116…370Outside left or right

CA9-S2-11 19.50

CA9-400…2650Outside left or right

CA9-S4-11 19.50

Low Power Auxiliary Contact Block for Side Mounting• 1-Pole• Two-way numbering for right or left mounting• Easy mounting without tools• Mirror contact performance to main contactor poles• Electronic compatible, 3V 1mA

1 0NO 18

NO 17NO 28

NO 27

CA9-116…370Inside left or right

CA9-S1-B10 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B10 ➊ 46

0 1NC 16

NC 15NC 26

NC 25

CA9-116…370Inside left or right

CA9-S1-B01 ➊ 46

CA9-400…2650Inside left or right

CA9-S3-B01 ➊ 46

NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the CA9 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory (inside left position).

Mechanical Interlocks Accessory Description For use with... Catalog Number Price

• Mechanical only, without auxiliary contacts• Interlocking of two same size contactors

CA9-116…CA9-370 CA9-M1-00 74

CA9-400…750, CA9-1260 ➋

CA9-M2-00 198

CA9-860…1060, CA9-2050…2650 ➌

CA9-M3-00 629

• Mechanical only, without auxiliary contacts• Interlocking of two different size contactors

CA9-116…146 to CA9-190…205

CA9-M4-00 74

CA9-190…205 to CA9-265…370

CA9-M5-00 74

• Rod for vertical mounting reversing contactors CA9-400…750 CA9-VR750 251

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

Inside Left position(CA9-S3)

Outside Left position(CA9-S4)

Inside Right position(CA9-S3)

Outside Right position(CA9-S4)

Inside Left position(CA9-S1)

Outside Left position(CA9-S2)

CA9-116…370 CA9-400…2650

Verticalmechanical interlock

CA9-VR750

Horizontal mechanical interlock

CA9-M_-00

Horizontal mechanical interlock CA9-M_-00

Vertical mechanical interlock CA9-VR750

Page 11: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

11

Accessories for CA9 Contactors

Terminal Shrouds

Description For use with… Catalogue No.

For contactors with compression lugs• Package contains 2 shrouds, one for line and one for load• Not applicable when using CA9-PW- Power wiring kits

CA9-190(-EI)…205(-EI) CA9-TS205C

CA9-265(-EI)…370(-EI) CA9-TS370C

CA9-400(-EI)…460(-EI) CA9-TS460C

CA9-580(-EI)…750(-EI), 1260-(EI) CA9-TS750C

For contactors with terminal lugs• Package contains 2 shrouds, one for line and one for load• Not applicable when using CA9-PW- Power wiring kits

CA9-116(-EI)…146(-EI) CA9-TS146L

CA9-190(-EI)…205(-EI) CA9-TS205L

CA9-265(-EI)…370(-EI) CA9-TS370L

CA9-400(-EI)…460(-EI) CA9-TS460L

CA9-580(-EI)…750(-EI) CA9-TS750L

Power Wiring Connection Kits

Application For use with… Catalogue No.

Reversing power wiring kits

CA9-116(-EI)…146(-EI) CA9-PW146

CA9-190(-EI)…205(-EI) CA9-PW205 1)

CA9-116(-EI)…370(-EI) CA9-PW370 1)

CA9-400-EI…460-EI CA9-PW460 2)

CA9-580-EI…750-EI CA9-PW750 2)

Delta contactor Star contactor

CA9-116(-EI)…146(-EI) CA9-116(-EI)…146(-EI) CA9-PWD146

CA9-190(-EI)…205(-EI) CA9-116(-EI)…146(-EI) CA9-PWD190

Star-delta power wiring kits

CA9-190(-EI)…205(-EI) CA9-190(-EI)…205(-EI) CA9-PWD205

CA9-265(-EI)…370(-EI) CA9-190(-EI)…205(-EI) CA9-PWD265

CA9-265(-EI)…370(-EI) CA9-265(-EI)…370(-EI) CA9-PWD370

CA9-400-EI…460-EI CA9-400-EI…460-EI CA9-PWD460

CA9-580-EI…750-EI CA9-400-EI…460-EI CA9-PWD580

CA9-580-EI…750-EI CA9-580-EI…750-EI CA9-PWD750

Shorting bar

CA9-116(-EI)…146(-EI) CA9-PWY146

CA9-190(-EI)…205(-EI) CA9-PWY205

CA9-265(-EI)…370(-EI) CA9-PWY370

CA9-400-EI…460-EI CA9-PWY460

CA9-580-EI…750-EI CA9-PWY750

Notes: 1) Power wiring kit includes one set of terminal extensions CA9-TX_. If terminal lugs CA9-TL are to be used on line and load side of reversing contactor, a second set of CA9-TX terminal extensions is required.

2) If terminal lugs CA9-TL_are to be used on the line and load side of reversing contactor, two sets of terminal extensions CA9-TX, are also required (none included).

A

CA9

Con

tact

ors

A95visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

Power Wiring Connection Kits Connection Kits Application For use with… Catalog Number Price

CA9-PW146

CA9-PWD460

Reversing Power Wiring Kits

CA9-116(-EI)…146(-EI) CA9-PW146 189

CA9-190(-EI)…205(-EI) CA9-PW205 ➊ 249

CA9-265(-EI)…370(-EI) CA9-PW370 ➊ 397

CA9-400-EI…460-EI CA9-PW460 ➋ 549

CA9-580-EI…750-EI CA9-PW750 ➋ 725

Wye-Delta Power Wiring Kits

Delta Contactor Wye Contactor

CA9-116(-EI)…146(-EI) CA9-116(-EI)…146(-EI) CA9-PWD146 235

CA9-190(-EI)…205(-EI) CA9-116(-EI)…146(-EI) CA9-PWD190 346

CA9-190(-EI)…205(-EI) CA9-190(-EI)…205(-EI) CA9-PWD205 364

CA9-265(-EI)…370(-EI) CA9-190(-EI)…205(-EI) CA9-PWD265 423

CA9-265(-EI)…370(-EI) CA9-265(-EI)…370(-EI) CA9-PWD370 505

CA9-400-EI…460-EI CA9-400-EI…460-EI CA9-PWD460 658

CA9-580-EI…750-EI CA9-400-EI…460-EI CA9-PWD580 756

CA9-580-EI…750-EI CA9-580-EI…750-EI CA9-PWD750 880

Shorting Bar

CA9-116(-EI)…146(-EI) CA9-PWY146 46

CA9-190(-EI)…205(-EI) CA9-PWY205 97

CA9-265(-EI)…370(-EI) CA9-PWY370 108

CA9-400-EI…460-EI CA9-PWY460 109

CA9-580-EI…750-EI CA9-PWY750 155

Mounting Plates (For CA9-116…750 Contactors)

Application Description For use with… Catalog Number Price

Non-Reversing Starters CA9-116(-EI)…146(-EI) CA9-MS146 43

CA9-190(-EI)…205(-EI) CA9-MS205 52

Reversing Contactors

CA9-116(-EI)…146(-EI) CA9-MR146 51

CA9-190(-EI)…205(-EI) CA9-MR205 63

CA9-265(-EI)…370(-EI) CA9-MR370 79

CA9-400-EI…460-EI CA9-MR460 93

CA9-580-EI…750-EI CA9-MR750 116

Reversing StartersCA9-116(-EI)…146(-EI) CA9-MRS146 88

CA9-190(-EI)…205(-EI) CA9-MRS205 106

➊ Power wiring kit includes one set of terminal extensions CA9-TX_. If terminal lugs CA9-TL_ are to be used on line and load side of reversing contactor, a second set of CA9-TX_ terminal extensions is required.

➋ If terminal lugs CA9-TL_ are to be used on the line and load side of reversing contactor, two sets of terminal extensions CA9-TX_ are also required (none included).

A C

A9 C

onta

ctor

s

A95visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

Power Wiring Connection Kits Connection Kits Application For use with… Catalog Number Price

CA9-PW146

CA9-PWD460

Reversing Power Wiring Kits

CA9-116(-EI)…146(-EI) CA9-PW146 189

CA9-190(-EI)…205(-EI) CA9-PW205 ➊ 249

CA9-265(-EI)…370(-EI) CA9-PW370 ➊ 397

CA9-400-EI…460-EI CA9-PW460 ➋ 549

CA9-580-EI…750-EI CA9-PW750 ➋ 725

Wye-Delta Power Wiring Kits

Delta Contactor Wye Contactor

CA9-116(-EI)…146(-EI) CA9-116(-EI)…146(-EI) CA9-PWD146 235

CA9-190(-EI)…205(-EI) CA9-116(-EI)…146(-EI) CA9-PWD190 346

CA9-190(-EI)…205(-EI) CA9-190(-EI)…205(-EI) CA9-PWD205 364

CA9-265(-EI)…370(-EI) CA9-190(-EI)…205(-EI) CA9-PWD265 423

CA9-265(-EI)…370(-EI) CA9-265(-EI)…370(-EI) CA9-PWD370 505

CA9-400-EI…460-EI CA9-400-EI…460-EI CA9-PWD460 658

CA9-580-EI…750-EI CA9-400-EI…460-EI CA9-PWD580 756

CA9-580-EI…750-EI CA9-580-EI…750-EI CA9-PWD750 880

Shorting Bar

CA9-116(-EI)…146(-EI) CA9-PWY146 46

CA9-190(-EI)…205(-EI) CA9-PWY205 97

CA9-265(-EI)…370(-EI) CA9-PWY370 108

CA9-400-EI…460-EI CA9-PWY460 109

CA9-580-EI…750-EI CA9-PWY750 155

Mounting Plates (For CA9-116…750 Contactors)

Application Description For use with… Catalog Number Price

Non-Reversing Starters CA9-116(-EI)…146(-EI) CA9-MS146 43

CA9-190(-EI)…205(-EI) CA9-MS205 52

Reversing Contactors

CA9-116(-EI)…146(-EI) CA9-MR146 51

CA9-190(-EI)…205(-EI) CA9-MR205 63

CA9-265(-EI)…370(-EI) CA9-MR370 79

CA9-400-EI…460-EI CA9-MR460 93

CA9-580-EI…750-EI CA9-MR750 116

Reversing StartersCA9-116(-EI)…146(-EI) CA9-MRS146 88

CA9-190(-EI)…205(-EI) CA9-MRS205 106

➊ Power wiring kit includes one set of terminal extensions CA9-TX_. If terminal lugs CA9-TL_ are to be used on line and load side of reversing contactor, a second set of CA9-TX_ terminal extensions is required.

➋ If terminal lugs CA9-TL_ are to be used on the line and load side of reversing contactor, two sets of terminal extensions CA9-TX_ are also required (none included).

A

CA9

Con

tact

ors

A94visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

See page A109 for terminal wire ranges.

Terminal Lugs and Accessories

Lug or Accessory Connection Wire Sizes For use with…Catalog Number

Price

Order 1 Pkg for 2 kits

Terminal Lug Kit - • Standard for CA9-116-_-L…146-_-L• Includes 2 sets, one for Line side and

one for Load Side

2 x 6 AWG…3/0 AWG CA9-116(-EI)…146(-EI) CA9-CL146 26

Order 1 Pkg for 3 lugs

Terminal Lugs• Includes 1 set of 3 lugs for use on

either Line or Load Side. • Order qty of 2 for both.

6 AWG…300 MCM CA9-190(-EI)…205(-EI) CA9-TL205 78

4 AWG…400 MCM CA9-265(-EI)…370(-EI) CA9-TL370 116

2 x 4 AWG…500 MCM CA9-265(-EI)…370(-EI) CA9-TL370B 170

3 x 2/0 AWG…500 MCM CA9-400-EI…460-EI CA9-TL580 300

2 x 2/0 AWG…500 MCM CA9-580-EI…750-EI, CA9-1260-EI CA9-TL750 434

4 x 4/0 AWG…500 MCM CA9-860-EI CA9-TL860 578

4 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060 821

6 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060B 1098

Terminal Enlargements• Enlargement pieces designed to increase the width of the contactor

terminal pads in order to allow larger connections to be mounted

CA9-116(-EI)…146(-EI) CA9-TE146 94

CA9-190(-EI)…205(-EI) CA9-TE205 119

CA9-265(-EI)…370(-EI) CA9-TE370 184

CA9-400-EI…460-EI CA9-TE460 236

CA9-580-EI…750-EI CA9-TE750 315

CA9-1260-EI CA9-TE1260 418

Terminal Extensions• Extension pieces designed to extend the main terminals of contactors

for combined mounting of contactors and connection sets

CA9-116(-EI)…146(-EI) CA9-TX146 67

CA9-190(-EI)…205(-EI) CA9-TX205 82

CA9-265(-EI)…370(-EI) CA9-TX370 149

CA9-400-EI…460-EI CA9-TX460 161

CA9-580-EI…750-EI CA9-TX750 220

Terminal Shrouds

Accessory Description For use with... Catalog Number Price

For contactors with Terminal Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-190(-EI)…205(-EI) CA9-TS205C 57

CA9-265(-EI)…370(-EI) CA9-TS370C 57

CA9-400-EI…460-EI CA9-TS460C 85

CA9-580-EI…750-EI, 1260-EI CA9-TS750C 101

For contactors with Compression Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-116(-EI)…146(-EI) CA9-TS146L 59

CA9-190(-EI)…205(-EI) CA9-TS205L 59

CA9-265(-EI)…370(-EI) CA9-TS370L 59

CA9-400-EI…460-EI CA9-TS460L 87

CA9-580-EI…750-EI CA9-TS750L 103For IP20 protection between contactor and overload relay on a non-reversing starter

CAT9-116(-EI)…146(-EI) CA9-TC146 42CAT9-190(-EI)…205(-EI) CA9-TC205 54

For IP20 protection between contactor and overload relay on a reversing starter

CAUT9-116(-EI)…146(-EI) CA9-TCR146 74

CAUT9-190(-EI)…205(-EI) CA9-TCR205 84

Terminal Extensions

Description For use with… Catalogue No.

• Extension pieces designed to extend the main terminals of contactors for combined mounting of contactors and connection sets

CA9-116(-EI)…146(-EI) CA9-TX146

CA9-190(-EI)…205(-EI) CA9-TX205

CA9-265(-EI)…370(-EI) CA9-TX370

CA9-400-EI…460-EI CA9-TX460

CA9-580-EI…750-EI CA9-TX750

A

CA9

Con

tact

ors

A94visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Accessories - Field InstallableCA9 Contactors

See page A109 for terminal wire ranges.

Terminal Lugs and Accessories

Lug or Accessory Connection Wire Sizes For use with…Catalog Number

Price

Order 1 Pkg for 2 kits

Terminal Lug Kit - • Standard for CA9-116-_-L…146-_-L• Includes 2 sets, one for Line side and

one for Load Side

2 x 6 AWG…3/0 AWG CA9-116(-EI)…146(-EI) CA9-CL146 26

Order 1 Pkg for 3 lugs

Terminal Lugs• Includes 1 set of 3 lugs for use on

either Line or Load Side. • Order qty of 2 for both.

6 AWG…300 MCM CA9-190(-EI)…205(-EI) CA9-TL205 78

4 AWG…400 MCM CA9-265(-EI)…370(-EI) CA9-TL370 116

2 x 4 AWG…500 MCM CA9-265(-EI)…370(-EI) CA9-TL370B 170

3 x 2/0 AWG…500 MCM CA9-400-EI…460-EI CA9-TL580 300

2 x 2/0 AWG…500 MCM CA9-580-EI…750-EI, CA9-1260-EI CA9-TL750 434

4 x 4/0 AWG…500 MCM CA9-860-EI CA9-TL860 578

4 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060 821

6 x 1/0 AWG…750 MCM CA9-1060-EI CA9-TL1060B 1098

Terminal Enlargements• Enlargement pieces designed to increase the width of the contactor

terminal pads in order to allow larger connections to be mounted

CA9-116(-EI)…146(-EI) CA9-TE146 94

CA9-190(-EI)…205(-EI) CA9-TE205 119

CA9-265(-EI)…370(-EI) CA9-TE370 184

CA9-400-EI…460-EI CA9-TE460 236

CA9-580-EI…750-EI CA9-TE750 315

CA9-1260-EI CA9-TE1260 418

Terminal Extensions• Extension pieces designed to extend the main terminals of contactors

for combined mounting of contactors and connection sets

CA9-116(-EI)…146(-EI) CA9-TX146 67

CA9-190(-EI)…205(-EI) CA9-TX205 82

CA9-265(-EI)…370(-EI) CA9-TX370 149

CA9-400-EI…460-EI CA9-TX460 161

CA9-580-EI…750-EI CA9-TX750 220

Terminal Shrouds

Accessory Description For use with... Catalog Number Price

For contactors with Terminal Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-190(-EI)…205(-EI) CA9-TS205C 57

CA9-265(-EI)…370(-EI) CA9-TS370C 57

CA9-400-EI…460-EI CA9-TS460C 85

CA9-580-EI…750-EI, 1260-EI CA9-TS750C 101

For contactors with Compression Lugs• Package contains 2 shrouds, one for Line

and one for Load side

CA9-116(-EI)…146(-EI) CA9-TS146L 59

CA9-190(-EI)…205(-EI) CA9-TS205L 59

CA9-265(-EI)…370(-EI) CA9-TS370L 59

CA9-400-EI…460-EI CA9-TS460L 87

CA9-580-EI…750-EI CA9-TS750L 103For IP20 protection between contactor and overload relay on a non-reversing starter

CAT9-116(-EI)…146(-EI) CA9-TC146 42CAT9-190(-EI)…205(-EI) CA9-TC205 54

For IP20 protection between contactor and overload relay on a reversing starter

CAUT9-116(-EI)…146(-EI) CA9-TCR146 74

CAUT9-190(-EI)…205(-EI) CA9-TCR205 84

Page 12: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

12

Electronic coil (typical) For use with… Voltage Coil code Catalogue No.

CA9-116

24-60V AC/DC 24W CA9-TG913

48-130V AC/DC 48W CA9-TG914

100-250V AC/DC 120W CA9-TG915

250-500V AC/DC 480W CA9-TG916

CA9-116-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE913

250-500V AC/DC w/ PLC Interface 480W CA9-TGE914

CA9-146

24-60V AC/DC 24W CA9-TG901

48-130V AC/DC 48W CA9-TG902

100-250V AC/DC 120W CA9-TG903

250-500V AC/DC 480W CA9-TG904

CA9-146-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE903

250-500V AC/DC w/ PLC Interface 480W CA9-TGE904

CA9-190CA9-250

24-60V AC/DC 24W CA9-TG905

48-130V AC/DC 48W CA9-TG906

100-250V AC/DC 120W CA9-TG907

250-500V AC/DC 480W CA9-TG908

CA9-190-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE915

250-500V AC/DC w/ PLC Interface 480W CA9-TGE916

CA9-205-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE907

250-500V AC/DC w/ PLC Interface 480W CA9-TGE908

CA9-265...370

24-60V AC/DC 24W CA9-TG909

48-130V AC/DC 48W CA9-TG910

100-250V AC/DC 120W CA9-TG911

250-500V AC/DC 480W CA9-TG912

CA9-265-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE917

250-500V AC/DC w/ PLC Interface 480W CA9-TGE918

CA9-305-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE919

250-500V AC/DC w/ PLC Interface 480W CA9-TGE920

CA9-370-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE911

250-500V AC/DC w/ PLC Interface 480W CA9-TGE912

CA9-400-EI,CA9-460-EI

24-60V DC 24W CA9-THE901

48-130V AC/DC 48W CA9-THE902

100-250V AC/DC 120W CA9-THE903

250-500V AC/DC 480W CA9-THE904

CA9-580...750-EI,CA9-1260-EI

24-60V DC 24W CA9-TJE901

48-130V AC/DC 48W CA9-TJE902

100-250V AC/DC 120W CA9-TJE903

250-500V AC/DC 480W CA9-TJE904

CA9-860-EI...1060-EI, CA9-2050-EI

100-250V AC/DC 120WCA9-TKE903 1)

CA9-TKE904 2)

CA9-2650-EI 100-250V AC/DC 120WCA9-TLE903 1)

CA9-TLE904 2)

A

CA9

Con

tact

ors

A96visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B6www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Renewal PartsCA9 Contactors

Renewal Coils - AC/DC, Electronic CoilElectronic Coil

(typical) For use with... Voltage Coil Code Catalog NumberPrice/

Set

Replacement Coil without EI Interface includes coil and cover

Replacement Coil with EI Interface includes coil, cover and face plate

CA9-116

24-60V AC/DC 24W CA9-TG913

97

48-130V AC/DC 48W CA9-TG914

100-250V AC/DC 120W CA9-TG915

250-500V AC/DC 480W CA9-TG916

CA9-116-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE913

250-500V AC/DC w/ PLC Interface 480W CA9-TGE914

CA9-146

24-60V AC/DC 24W CA9-TG901

48-130V AC/DC 48W CA9-TG902

100-250V AC/DC 120W CA9-TG903

250-500V AC/DC 480W CA9-TG904

CA9-146-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE903

250-500V AC/DC w/ PLC Interface 480W CA9-TGE904

CA9-190

CA9-205

24-60V AC/DC 24W CA9-TG905

48-130V AC/DC 48W CA9-TG906

100-250V AC/DC 120W CA9-TG907

250-500V AC/DC 480W CA9-TG908

CA9-190-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE915

250-500V AC/DC w/ PLC Interface 480W CA9-TGE916

CA9-205-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE907

250-500V AC/DC w/ PLC Interface 480W CA9-TGE908

CA9-265…370

24-60V AC/DC 24W CA9-TG909

48-130V AC/DC 48W CA9-TG910

100-250V AC/DC 120W CA9-TG911

250-500V AC/DC 480W CA9-TG912

CA9-265-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE917

250-500V AC/DC w/ PLC Interface 480W CA9-TGE918

CA9-305-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE919

250-500V AC/DC w/ PLC Interface 480W CA9-TGE920

CA9-370-EI100-250V AC/DC w/ PLC Interface 120W CA9-TGE911

250-500V AC/DC w/ PLC Interface 480W CA9-TGE912

CA9-400-EI, CA9-460-EI

24-60V DC 24W CA9-THE901

48-130V AC/DC 48W CA9-THE902

100-250V AC/DC 120W CA9-THE903

250-500V AC/DC 480W CA9-THE904

CA9-580…750-EI,CA9-1260-EI

24-60V DC 24W CA9-TJE901

48-130V AC/DC 48W CA9-TJE902

100-250V AC/DC 120W CA9-TJE903

250-500V AC/DC 480W CA9-TJE904

CA9-860-EI…1060-EI,CA9-2050-EI

100-250V AC/DC 120WCA9-TKE903 ➊

CA9-TKE904 ➋

CA9-2650-EI 100-250V AC/DC 120WCA9-TLE903 ➊

CA9-TLE904 ➋

➊ One set of two (2) coils.➋ Printed circuit board.

Notes: 1) One set of two (2) coils 2) Printed circuit board

Renewal parts

Page 13: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

13

Renewal Contact Kits and Arc Chutes

Description For use with… Catalogue No.

Contact kits

CA9-116(-EI) CA9-A116

CA9-146(-EI) CA9-A146

CA9-190(-EI) CA9-A190

CA9-205(-EI) CA9-A205

CA9-265(-EI) CA9-A265

CA9-305(-EI) CA9-A305

CA9-370(-EI) CA9-A370

CA9-400-EI CA9-A400

CA9-460-EI CA9-A460

CA9-580-EI CA9-A580

CA9-750-EI CA9-A750

CA9-860-EI CA9-A860

CA9-1060-EI CA9-A1060

CA9-1260-EI CA9-A1260

CA9-2050-EI CA9-A2050

CA9-2650-EI CA9-A2650 1)

Arc chutes

CA9-400-EI…460-EI CA9-C460

CA9-580-EI…750-EICA9-1260-EI

CA9-C750

CA9-860-EI…1060-EICA9-2050-EI

CA9-C1060

CA9-2650-EI CA9-C2650

Replacement Terminal Hardware

Description For use with… Catalogue No.

Standard screws and washers

CA9-116…146(-EI) CA9-HF146

CA9-190…205(-EI) CA9-HF205

CA9-265…370(-EI) CA9-HF370

CA9-400…460-EI CA9-HF460

CA9-580-EI…750-EICA9-1260-EI

CA9-HF750

CA9-860-EI...1060-EICA9-2050-EI

CA9-HF2050

CA9-2650-EI CA9-HF2650

A

CA9

Con

tact

ors

A97visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B6www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Renewal PartsCA9 Contactors

➊ Movable contacts only.

Renewal Contact Kits and Arc Chutes

Description For use with... Catalog NumberPrice/

Set

Contact Kits

CA9-116(-EI) CA9-A116 292

CA9-146(-EI) CA9-A146 468

CA9-190(-EI) CA9-A190 582

CA9-205(-EI) CA9-A205 754

CA9-265(-EI) CA9-A265 945

CA9-305(-EI) CA9-A305 1130

CA9-370(-EI) CA9-A370 1350

CA9-400-EI CA9-A400 1620

CA9-460-EI CA9-A460 2000

CA9-580-EI CA9-A580 2910

CA9-750-EI CA9-A750 3930

CA9-860-EI CA9-A860 4840

CA9-1060-EI CA9-A1060 5590

CA9-1260-EI CA9-A1260 4150

CA9-2050-EI CA9-A2050 5910

CA9-2650-EI CA9-A2650 ➊ 6380

Arc Chutes

CA9-400-EI…460-EI CA9-C460 310

CA9-580-EI…750-EI, CA9-1260-EI

CA9-C750 448

CA9-860-EI…1060-EI, CA9-2050-EI

CA9-C1060 650

CA9-2650-EI CA9-C2650 938

Replacement Terminal Hardware

Description For use with... Catalog NumberPrice/

Set

Standard Screws

and Washers

CA9-116…146(-EI) CA9-HF146 39.80

CA9-190…205(-EI) CA9-HF205 52.80

CA9-265…370(-EI) CA9-HF370 67.10

CA9-400…460-EI CA9-HF460 80.80

CA9-580, 750, 1060-EI CA9-HF750 122.00

CA9-2050-EI CA9-HF2050 114.00

CA9-2650-EI CA9-HF2650 169.00

A

CA9

Con

tact

ors

A97visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B6www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Renewal PartsCA9 Contactors

➊ Movable contacts only.

Renewal Contact Kits and Arc Chutes

Description For use with... Catalog NumberPrice/

Set

Contact Kits

CA9-116(-EI) CA9-A116 292

CA9-146(-EI) CA9-A146 468

CA9-190(-EI) CA9-A190 582

CA9-205(-EI) CA9-A205 754

CA9-265(-EI) CA9-A265 945

CA9-305(-EI) CA9-A305 1130

CA9-370(-EI) CA9-A370 1350

CA9-400-EI CA9-A400 1620

CA9-460-EI CA9-A460 2000

CA9-580-EI CA9-A580 2910

CA9-750-EI CA9-A750 3930

CA9-860-EI CA9-A860 4840

CA9-1060-EI CA9-A1060 5590

CA9-1260-EI CA9-A1260 4150

CA9-2050-EI CA9-A2050 5910

CA9-2650-EI CA9-A2650 ➊ 6380

Arc Chutes

CA9-400-EI…460-EI CA9-C460 310

CA9-580-EI…750-EI, CA9-1260-EI

CA9-C750 448

CA9-860-EI…1060-EI, CA9-2050-EI

CA9-C1060 650

CA9-2650-EI CA9-C2650 938

Replacement Terminal Hardware

Description For use with... Catalog NumberPrice/

Set

Standard Screws

and Washers

CA9-116…146(-EI) CA9-HF146 39.80

CA9-190…205(-EI) CA9-HF205 52.80

CA9-265…370(-EI) CA9-HF370 67.10

CA9-400…460-EI CA9-HF460 80.80

CA9-580, 750, 1060-EI CA9-HF750 122.00

CA9-2050-EI CA9-HF2050 114.00

CA9-2650-EI CA9-HF2650 169.00

Renewal parts

Note: 1) Moveable contact only

Page 14: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

14

Series CA6 to Series CA9 1)

Rated operational currentIe (A)

Ratings for switching AC motors AC-3Series CA6obsolete

Series CA9equivalent 2)

AC-3 (400/415V)60º C

AC-1 (690V)40º C

kW (50Hz)Catalogue No. Catalogue No.

400V 415V 690V 1000V

115 250 63 66 111 63 CA6-115

116 160 55 55 63 55 CA9-116

140 250 78 82 111 75 CA6-140

146 225 75 75 90 75 CA9-146

180 250 90 105 135 90 CA6-180

190 275 90 90 132 110 CA9-190

205 350 110 110 160 132 CA9-205

210 350 118 122 205 110 CA6-210

250 350 140 145 250 132 CA6-250

265 400 132 132 200 132 CA9-265

300 450 170 176 293 160 CA6-300

305 500 160 160 250 132 CA9-305

370 600 200 200 315 220 CA9-370

400 600 200 220 315 220 CA9-400

420 500 238 250 424 255 CA6-420

460 700 250 250 355 280 CA9-460

580 800 315 355 500 355 CA9-580

630 800 355 355 500 - CA6-630

750 1050 400 425 600 400 CA9-750

860 1000 500 500 - - CA6-860

860 1350 475 500 800 555 CA9-860

Contactor Cross Reference

Notes: 1) Available auxiliary contacts may vary. See selection pages for more information

2) Cross reference recommendations are based on an inductive load (AC-3 Amps), whereby the CA9 has a rated operational current Ie (A) AC-3, 400V, 60º C, greater than or equal to that of the CA6

Page 15: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

15

Technical information

Related isolation voltage Ui

IECUL; CSA

[V][V]

CA9-116...2650

1000V600V

Rated voltage Uimp [kV] 8

Rated voltage Ue Main Contacts

AC 50/60HzDC

[V][V]

115, 200, 230, 240, 400, 415, 460, 500, 575, 690, 100024, 48, 110, 220, 440

Operating frequency for AC loads [Hz] 50/60Hz

Electromagnetic compatibility IEC 60947-1 Environment A

Insulation class of the coil Class F per IEC 60947-4-1

Rated coil frequency AC 50/60 Hz, DC

Ambient temperatureStorageOperation at rated voltage

[ºC][ºC]

-40...+70-40...+70

Max. Altitude of installation site [m] 3000

Resistance to shock IEC 60068-2-27

Resistance to vibration IEC 60068-2-6

Protection classContactor main contactContactor coil terminalsAuxillary contacts

IP00IP2X (in connected state)IP2X (in connected state)

Standards IEC/EN60947-4-1: 2010 +A1:2012- Low-voltage switch gear and control gear - Part 4-1: Contactors and motor starters - electromechanical contactors and motor starters.

Note: Contact NHP for complete technical specifications

Mounting position

A

CA9

Con

tact

ors

A115visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-116…146-_-L (Contactors/Reversing Contactors)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

30 M4

100

(3.9

4)55.5

(2.1

8)

150

(5.9

1)

90

D

10

30(1.18)

19.5

(0.7

7)

126

Series CA9-116-EI…146-EI-_-L (Contactors/Reversing Contactors with PLC Interface)

90

30(1.18)

D

150

(5.9

1)

10

55.5

(2.1

8)

19.5

(0.7

7)

142.5 30 M4 10

0 (3

.94)

DimensionsCA9 Contactors

30°

120°

180°

180°

Mounting Position

Page 16: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

16

Contact NHP for infromation on adaptor plates for retro-fit applications

Approximate height and width comparisonsDimensions are shown in mm. Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.Approximate height and width comparisons:

new 100-E contactors to equivalent 100-D/G contactors15

0

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

12017

0

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

Copyright © 2017 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.

Allen-Bradley, Listen.Think.Solve., Rockwell Automation, Studio Logix 5000 Designer and Rockwell Software are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.

Publication MIGRAT-PP033A-EN-P – April 2018

210

273

100-E580…100-E750

210 (8.27)

344

(13.

54)

100-E1260

310

255

D630/860

280 (11.02)

307

(12.

07)

G860

E860, E1060, E2050

392

(15.

43)

438 (17.24)

334 (13.15)

490

(19.

29)

G1000/G1200

Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

Copyright © 2017 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.

Allen-Bradley, Listen.Think.Solve., Rockwell Automation, Studio Logix 5000 Designer and Rockwell Software are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.

Publication MIGRAT-PP033A-EN-P – April 2018

210

273

100-E580…100-E750

210 (8.27)

344

(13.

54)

100-E1260

310

255

D630/860

280 (11.02)

307

(12.

07)

G860

E860, E1060, E2050

392

(15.

43)

438 (17.24)

334 (13.15)

490

(19.

29)

G1000/G1200

CA9 116/146CA6 115/140Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

CA9 205CA6 210

Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/46020

7

155

D420

Approximate height and width comparisons:new 100-E contactors to equivalent 100-D/G contactors

150

Dimensions are shown in millimeters (inches). Drawing scales vary by size of contactors and are intended to provide approximate visual comparisons only.

E116/146

105

196

10 140

225

10

E265/305/370

120

170

100-D115/140

10 90

120

170

D180

207

155

D300

E190

105

196

10

E205

207

155

D210

186

268

E400/460

207

155

D420

CA9 190CA6 180

CA9 265/305/370CA6 300

CA9 400/460CA6 420 CA9 580/750CA6 630/860

Page 17: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

17

CA9-116...146-_-L (contactors)

CA9-116-EI...146-EI-_-L (contactors with PLC interface)

A

CA9

Con

tact

ors

A115visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-116…146-_-L (Contactors/Reversing Contactors)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

30 M4

100

55.5

150

90

D

10

30

19.5

126

Series CA9-116-EI…146-EI-_-L (Contactors/Reversing Contactors with PLC Interface)

90

30

D

150

10

55.5

19.5

142.5 30 M4 10

0

DimensionsCA9 Contactors

30°

120°

180°

180°

Mounting Position

Dimensions

Series CA9-190...205 (contactors)

A

CA9

Con

tact

ors

A116visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-190…205 (Contactors/Reversing Contactors)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

105 ø 8.5

35

196

10

152

83.5

35.5 5

29.5

35 M5

165

Series CA9-190-EI…205-EI (Contactors/Reversing Contactors with PLC Interface)

105 ø 8.5

35

196

10

83.5

35.5 5

29.5

169.5

35 M5

165

(6.5

0)

DimensionsCA9 Contactors

Dimensions are in mm. Dimensions not intended for manufacturing purposes A

CA9

Con

tact

ors

A115visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-116…146-_-L (Contactors/Reversing Contactors)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

30 M4

100

55.5

150

90

D

10

30

19.5

126

Series CA9-116-EI…146-EI-_-L (Contactors/Reversing Contactors with PLC Interface)

90

30

D

150

10

55.5

19.5

142.5 30 M4

100

DimensionsCA9 Contactors

30°

120°

180°

180°

Mounting Position

Page 18: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

18

CA9-265...370 (contactors)

CA9-256-EI...370-EI (contactors with PLC interface)

A

CA9

Con

tact

ors

A117visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-265…370 (Contactors/Reversing Contactors)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

140

19.5ø 10.5

43.75

180

94.7

225

35.5 5

33.4

1043.75 M5

187

Series CA9-265-EI…370-EI (Contactors/Reversing Contactors with PLC Interface)

140

19.5 ø 10.5

43.75

94.7

225

35.5 5

33.4

10 195.5

43.75 M5

187

DimensionsCA9 Contactors

CA9-190-EI...205-EI (contactors with PLC interface)

A

CA9

Con

tact

ors

A117visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-265…370 (Contactors/Reversing Contactors)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

140

19.5ø 10.5

43.75

180

94.7

225

35.5 5

33.4

1043.75 M5

187

Series CA9-265-EI…370-EI (Contactors/Reversing Contactors with PLC Interface)

140

19.5 ø 10.5

43.75

94.7

225

35.5 5

33.4

10 195.5

43.75 M5

187

DimensionsCA9 Contactors

Dimensions Dimensions are in mm. Dimensions not intended for manufacturing purposes

A

CA9

Con

tact

ors

A116visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-190…205 (Contactors/Reversing Contactors)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

105 ø 8.5

3519

6

10

152

83.5

35.5 5

29.5

35 M5

165

Series CA9-190-EI…205-EI (Contactors/Reversing Contactors with PLC Interface)

105 ø 8.5

35

196

1083

.5

35.5 5

29.5

169.5

35 M5

165

(6.5

0)

DimensionsCA9 Contactors

Page 19: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

19

CA9-400-EI...460-EI (contactors with PLC interface)

A

CA9

Con

tact

ors

A118visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-400-EI…460-EI (Contactors/Reversing Contactors with PLC Interface)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

63

186

11.5

268

ø 10.5216

48.5 6

278

ø 6.5 63

248

M5

Series CA9-580-EI, CA9-750-EI (Contactors/Reversing Contactors with PLC Interface)

72

210

40 22.5

11.5

273

ø 12.5ø 6.5

242

48.5 6

283

72

249

M6

DimensionsCA9 Contactors

25 25.5

CA9-580-EI...750-EI (contactors with PLC interface)

Dimensions Dimensions are in mm. Dimensions not intended for manufacturing purposes

A

CA9

Con

tact

ors

A118visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-400-EI…460-EI (Contactors/Reversing Contactors with PLC Interface)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

63

186

11.5

268

ø 10.5216

48.5 6

278

ø 6.5 63

248

M5

Series CA9-580-EI, CA9-750-EI (Contactors/Reversing Contactors with PLC Interface)

72

210

40 22.5

11.5

273

ø 12.5ø 6.5

242

48.5 6

283

72

249

M6

DimensionsCA9 Contactors

25 25.5

Page 20: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

20

CA9-1260-EI (contactors with PLC interface)

CA9-860-EI, CA9-1060-EI, CA9-2050-EI, CA9-2650-EI (contactors with PLC interface)

A

CA9

Con

tact

ors

A119visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-1260-EI (Contactors with PLC Interface)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

50

72

72

210

344

313

263

72

ø 7

ø 7

27 24

9 242

46.5 8

72

249

M6

Series CA9-860-EI, CA9-1060-EI, CA9-2050-EI, CA9-2650-EI (Contactors with PLC Interface)

40

CA9-2050, 2650

40ø 13

136 136

80 ø 9

B

438

A 312

C

244

101

40 27

30

17

40

17

10

CA9-860, 1060

13

136

136

M8

312

Dim CA9-860, 1060, 2050

CA9-2650

A 392 422

B 47 53

C 10 25

DimensionsCA9 ContactorsDimensions Dimensions are in mm. Dimensions not intended for manufacturing purposes

A

CA9

Con

tact

ors

A119visit www.sprecherschuh.com/ecatalog for pricing and the most up to date informationSSNA2018

Discount Schedule B7www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

Series CA9-1260-EI (Contactors with PLC Interface)Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

50

72

72

210

344

313

263

72

ø 7

ø 7

27

249

242

46.5 8

72

249

M6

Series CA9-860-EI, CA9-1060-EI, CA9-2050-EI, CA9-2650-EI (Contactors with PLC Interface)

40

CA9-2050, 2650

40ø 13

136 136

80 ø 9

B

438

A 312

C

244

101

40 27

30

17

40

17

10

CA9-860, 1060

13

136

136

M8

312

Dim CA9-860, 1060, 2050

CA9-2650

A 392 422

B 47 53

C 10 25

DimensionsCA9 Contactors

Page 21: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

21

CEP7 Overload Relay mounted to CA9 Contactor (116-205A)

B C

EP7

Over

load

s

B24visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B3www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

F

I

J

BC

D

A

E

G

H

KL

B

I

A

K

45(1.77)

53(2.087)

G

LF

C

D

EH

CEP7 Current Transformer Models mounted to CA9 Contactor (116-205A)

30

100

135

100

90

120

341.23 219.1

3.58

Ø5.5

35

165

279.7

3.58

100

135

59.46

55.11

120

105

392.3

152.8

152.8

CA9-116 AND CA9-146 CONTACTORS SHOWN CA9-190 AND CA9-205 CONTACTORS SHOWN

Ø5.5

CEP7-CT

DimensionsCEP7 Solid State Overload Relays

M

OVER LOADRELAY

L1

L1

T1 T2 T3

L2 L3

L2 L3

H1(Dot) H1(Dot) H1(Dot)

H2 H2 H2

X1 1X1X

X2X2X2CT1

T1 T2T3

CT2 CT3

DIMENSIONS mm (inches)

A B C D E F G H I J K L

CEP7-CT-UL-300 27.29 (1.09) 134.4 (5.29) 123.2 (4.85) 59.4 (2.34) 115.8 (4.56) 54.1 (2.13) 44.45 (1.75) 96 (3.78) 63.5 (2.50) 4.3 (0.17) 27.4 (1.08) 54.1 (2.13)CEP7-CT-UL-600 83.31 (3.28) 79.5 (3.13) 68.6 (2.7) 32.5 (1.27) 60.96 (2.40) 50 (1.96) 40.4 (1.59) 44.45 (1.75) 29 (1.14) 3 (0.118) 24 (0.94) 50 (1.96)CEP7-CT-CE-300 96 (3.75) 108.5 (4.27) 105.5 (4.85) 48.3 (1.90) 95 (3.74) 4.5 (0.177) 57 (2.24) 70 (3.75) 44 (1.73) ~ 40 (1.58) 72 (2.83)CEP7-CT-CE-400 71 (2.80) 88.5 (3.48) 85.5 (2.7) 36.75 (1.27) 70 (2.75) 6.5 (0.26) 57 (2.24) 50 (1.97) 32 (1.26) ~ 40 (1.58) 72 (2.83)

CEP7-CT-CECEP7-CT-UL

Dimensions Dimensions are in mm. Dimensions not intended for manufacturing purposes

B

CEP

7 Ov

erlo

ads

B24visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

Discount Schedule B3www.sprecherschuh.com/ecatalog - All pricing shown in US dollars

F

I

J

BC

D

A

E

G

H

KL

B

I

A

K

45(1.77)

53(2.087)

G

LF

C

D

EH

CEP7 Current Transformer Models mounted to CA9 Contactor (116-205A)

30

100

135

100

90

120

341.23 219.1

3.58

Ø5.5

35

165

279.7

3.58

100

135

59.46

55.11

120

105

392.3

152.8

152.8

CA9-116 AND CA9-146 CONTACTORS SHOWN CA9-190 AND CA9-205 CONTACTORS SHOWN

Ø5.5

CEP7-CT

DimensionsCEP7 Solid State Overload Relays

M

OVER LOADRELAY

L1

L1

T1 T2 T3

L2 L3

L2 L3

H1(Dot) H1(Dot) H1(Dot)

H2 H2 H2

X1 1X1X

X2X2X2CT1

T1 T2T3

CT2 CT3

DIMENSIONS mm (inches)

A B C D E F G H I J K L

CEP7-CT-UL-300 27.29 (1.09) 134.4 (5.29) 123.2 (4.85) 59.4 (2.34) 115.8 (4.56) 54.1 (2.13) 44.45 (1.75) 96 (3.78) 63.5 (2.50) 4.3 (0.17) 27.4 (1.08) 54.1 (2.13)CEP7-CT-UL-600 83.31 (3.28) 79.5 (3.13) 68.6 (2.7) 32.5 (1.27) 60.96 (2.40) 50 (1.96) 40.4 (1.59) 44.45 (1.75) 29 (1.14) 3 (0.118) 24 (0.94) 50 (1.96)CEP7-CT-CE-300 96 (3.75) 108.5 (4.27) 105.5 (4.85) 48.3 (1.90) 95 (3.74) 4.5 (0.177) 57 (2.24) 70 (3.75) 44 (1.73) ~ 40 (1.58) 72 (2.83)CEP7-CT-CE-400 71 (2.80) 88.5 (3.48) 85.5 (2.7) 36.75 (1.27) 70 (2.75) 6.5 (0.26) 57 (2.24) 50 (1.97) 32 (1.26) ~ 40 (1.58) 72 (2.83)

CEP7-CT-CECEP7-CT-UL

CA9-116 and CA9-146 contactors shown

CA9-190 and CA9-205 contactors shown

Page 22: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

22

Dimensions

Electronic overload relay and panel adapter are loose supplied and shown assembled in the below diagram

Dimensions are in mm. Dimensions not intended for manufacturing purposes

Rockwell Automation Publication 193-TD011C-EN-P - May 2018 19

E1 Plus Overload Relay Specifications

Figure 11 - Panel Adapter Mounted

Panel Adapter Cat. No.

Overload Cat. No.

Width A Height B Depth C D E1 E2 F H1 H2 H3 J

193-EPB

193-ED B193-EE B

193R-EE B193S-EE B

45(1-25/32

116.5 (4-19/16)

92.7 (3-21/32) 4.4 (11/64) 11.4

(0.45)57.9

(2-9/32)62.5

(2-15/32) 95 (3-3/4) 30(1-3/16)

75(2-31/32)

52.1 (2-3/64)

193-EPD193-EE D

193R-EE D193S-EE D

45(1-25/32

112.4 (4-7/16)

108.7 (4-9/32) 4.4 (11/64) 11.4

(0.45)57.9

(2-9/32)62.5

(2-15/32) 95 (3-3/4) 30(1-3/16)

75(2-31/32)

52.1 (2-3/64)

193-EPE193-EE E

193R-EE E193S-EE E

72(2-53/64)

107.4 (4-15/64) 127 (5/32) 5.5 (5/32) 26.4

(1-1/32)54.5

(2-9/64)48.3

(1-29/32)90

(3-23/64)60

(2-23/64) — 43.3 (1-45/64)

2 T1 4 T2 6 T3

75

52.1

62.5

92.7

45

95

11.44.4

30

57.9

116

L1

1 3 5

L 2 L3

A 41 x 21 51 x 20 64 x 19 10 x 24= + + +

Current Transformer Kits

CT Window

Page 23: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

23

Why NHPWhile our customers’ challenges may be complex, their ultimate goal is simple: run a profitable, safe and sustainable operation.

At NHP we’re committed to servicing the needs of our customers. With 50 years of experience in the electrical and engineering industry, our specialist teams work collaboratively to design and deliver solutions to maximise the success of your project.

We bring together internationally recognised automation, power distribution and motor control products with local knowledge and expertise to deliver best practice services from concept design through to installation and after-sales service, including project management.

Extensively trained and qualified service

technicians

NHP project management

24/7/365 Emergency service

National service network

Extensive local stockholding

A partnership with NHP will provide you with:

Customised manufactured

solutions

Page 24: Series CA9 Contactors - NHP Electrical CA9-116 contactor CA9-400-EI contactor Note: CA9-190…2650 open-type contactors include terminal bolts. If lugs are required, see page A94 for

NHP Electrical Engineering Products A.B.N. 84 004 304 812

NHP96722 03 /19

© Copyright NHP 2019

For more information, scan to download the NHP eCatalogues App o�ering exclusive video content, catalogues and literature!

For more information, scan to download the NHP eCatalogues App offering exclusive

video content, catalogues and literature

AUSTRALIAnhp.com.au

SALES 1300 NHP NHP

[email protected]

NEW ZEALANDnhp-nz.com

SALES 0800 NHP NHP

[email protected]