1
Series 9X / CE Version Direct Spark with Flame rectification for use in European Community Industry standard wiring Diagnostic LED Agency Certifications CSA ANSI Z21.20 CSA C22.2 No. 199-M89 Selection Options Waiting time (pre-purge), inter-waiting (Inter-purge) timings Sensing method: Selectable trial time in auto recycle, or lockout mode Single or dual rod flame sensing applications Vollatile or Non-Volatile reset Flame Stabilization Quick Start Alarm Output Contact Capable Controls for ordering instructions Made in USA Description The 9X Series with dual microprocessor and redundant circuitry designed to meet stringent CE requirements for new or replacement applications. Also has North American and Australian Gas certifications These include central furnaces, space heaters, tumblers, residential and commercial boilers, and commercial cooking applications. Control wiring is standardized to retrofit easily into existing applications. The ignition system features a temperature stabilized detection circuit that allows greater pilot flame variations without false flame response. The valve drive relay are rated for extended mechanical and electrical operations using 16 Amp heavy duty relays CE requires Volatile lockout which requires the unit to be reset via a power cycling of the equipment of Non-Volatile lockout which requires a remote switch sense. ODL "Optical Data Link" programming is designed into this for immediate downloading of programs. Features Dual Microprocessor safety design Highly Stable Flame Sensing Programmable characteristics Inter-waiting (Inter-purge), Waiting (Pre-purge) and Safety (Trail) delays are configurable. Replaces many competitive units. Operating Temperature 80°C Volatile or Non-Volatile Lockout reset (CE requirement) Applications Gas Furnaces Residential and Commercial Boilers Water / Space Heaters Commercial Cooking Appliances SPECIFICATIONS Spa and Pool Heaters Power Input: 24 Vac 50 / 60 Hz Power Consumption: 4.8 Va Max Main Relay: 5 Amps Flame Sensing: 0.15 uA Minimum Gas Types: Natural, LP or Manufactured Alarm Relay: 1 Amp @ 24 Vac Style: Enclosed in Flameproof housing Temperature: -40 - 80°C Operating humidity: 95% non-condensing Rectification Electrical: 16 Amp Heavy duty relays Operating current: 0.2 Amps Mounting position: multipoise 123mm x 80mm x 38mm Pilot burner rating: 1,500 BTU's / Hour max. Spark Gap: 5 mm / 0.20 inches Connections: 1/4" male Fast-ons® CE EN 298:2003 INPUT VOLTAGES DESCRIPTION Main burner rating: 400,000 BTU's / Hour max. Dimensions: Intermittent Series shown 630-860-6514 www.capablecontrols.com [email protected] 790 Maple Lane Bensenville, Illinois 60106 inc. Capable Controls Capable Controls Inc. Certified to Standards AG206 and AG210

SERIES 9X MAILER - Capable Controls 9X CE DSI.pdf · 2018-05-30 · The ignition system features a temperature stabilized detection circuit that allows greater pilot flame variations

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SERIES 9X MAILER - Capable Controls 9X CE DSI.pdf · 2018-05-30 · The ignition system features a temperature stabilized detection circuit that allows greater pilot flame variations

Series 9X / CE VersionDirect Spark with Flame rectification for use in European Community

Industry standard wiringDiagnostic LED

Agency Certifications

CSA ANSI Z21.20

CSA C22.2 No. 199-M89

Selection OptionsWaiting time (pre-purge), inter-waiting (Inter-purge) timings

Sensing method:Selectable trial time in auto recycle, or lockout modeSingle or dual rod flame sensing applicationsVollatile or Non-Volatile resetFlame StabilizationQuick StartAlarm OutputContact Capable Controls for ordering instructionsMade in USA

DescriptionThe 9X Series with dual microprocessor and redundant circuitry designed to meet stringent CE requirements for new or replacement applications.Also has North American and Australian Gas certificationsThese include central furnaces, space heaters, tumblers, residential and commercial boilers, and commercial cooking applications.Control wiring is standardized to retrofit easily into existing applications.The ignition system features a temperature stabilized detection circuit that allows greater pilot flame variations without false flame response.The valve drive relay are rated for extended mechanical and electrical operations using 16 Amp heavy duty relaysCE requires Volatile lockout which requires the unit to be reset via a power cycling of the equipment of Non-Volatile lockout which requires a remote switch sense.ODL "Optical Data Link" programming is designed into this for immediate downloading of programs.

FeaturesDual Microprocessor safety designHighly Stable Flame SensingProgrammable characteristicsInter-waiting (Inter-purge), Waiting (Pre-purge)and Safety (Trail) delays are configurable.Replaces many competitive units.Operating Temperature 80°C

Volatile or Non-Volatile Lockout reset (CE requirement)

ApplicationsGas FurnacesResidential and Commercial BoilersWater / Space HeatersCommercial Cooking Appliances SPECIFICATIONSSpa and Pool Heaters

Power Input: 24 Vac 50 / 60 HzPower Consumption: 4.8 Va Max

Main Relay: 5 Amps

Flame Sensing: 0.15 uA MinimumGas Types: Natural, LP or Manufactured

Alarm Relay: 1 Amp @ 24 VacStyle: Enclosed in Flameproof housingTemperature: -40 - 80°COperating humidity: 95% non-condensing

RectificationElectrical: 16 Amp Heavy duty relays

Operating current: 0.2 AmpsMounting position: multipoise

123mm x 80mm x 38mmPilot burner rating: 1,500 BTU's / Hour max.

Spark Gap: 5 mm / 0.20 inchesConnections: 1/4" male Fast-ons®

CE EN 298:2003

INPUT VOLTAGES DESCRIPTION

Main burner rating: 400,000 BTU's / Hour max.

Dimensions:

Intermittent Series shown

630-860-6514 www.capablecontrols.com [email protected] Maple Lane Bensenville, Illinois 60106

inc.

CapableControls

Capable Controls Inc.

Certified to Standards AG206 and AG210