24
CAB LES CAN SERIES 90 & SERIES 90HV REFERENCE MANUAL SECTION 7.0 PROGRAM October 7, 1993

SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

CAB LES CAN

SERIES 90 & SERIES 90HV

REFERENCE MANUAL

SECTION 7.0

PROGRAM

October 7, 1993

Page 2: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page ii

Page 3: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page iii

• TABLE OF CONTENTS

INTRODUCfION .................................................................................................... 1

DISCUSSION .................................................................................................. 1

CROSS REFERENCE LABEl.S ................................................................. 2

PROGRAM FUNCfIONS ..................................................................................... 2

EDITOR ........................................................................................................... 2

COMPILE ........................................................................................................ 3

LEARN ............................................................................................................. 4 l.earning with Components .................................................................. 5

IMPORT ........................................................................................................... 6 Import Sources ....................................................................................... 6

Model 4000 Program ................................................................... 6 Model 512 Program ..................................................................... 6 Menu Program ............................................................................. 7

• Text File ........................................................................................ 7 Running Import ..................................................................................... 7

Import-From Location ................................................................ 8 Import-To Location ..................................................................... 9

LOAD PROGRAM ...................................................................................... 12

TEXT IMPORT SPECIFICATIONS .................................................................. 14

DISCUSSION ................................................................................................ 14

TEXT FILE FORMAT ................................................................................ 14

DATA FORMATS ....................................................................................... 15 Wire List. ............................................................................................... 15 Cross Reference List ........................................................................... 17 Program Options ................................................................................. 18 Lamp Driver List ................................................................................. 19

Page 4: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

Page 5: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 1

INTRODUCTION

DISCUSSION

The Program category is used to create, load, import, and edit wire list programs for testing and assembly. The Learn function, using a completed known-good assembly, is the typical method used in creating wire lists for test applications. It stores the continuities in an arrangement that enhances test speed. When a known-good assembly is not available for a test program, however, the wire list can be entered through the keyboard using the Edit function.

For most build applications, the Edit function (Program Editor) is used, in order to control the wiring sequence and thus maintain uniformity among assemblies. The program editor also is used to enter cross references or make engineering changes in the wire list, or when programming components.

There are three ways to create a wire list program:

• EDIT - for entering a wire list program through the keyboard, using the Program Editor.

• LEARN - for creating a wire list automatically by scanning a Known-Good assembly connected to the scanner boards.

• IMPORT - for acquiring an existing wire list program that was created from another source.

Programs already in disk memory may be obtained through a Load Program function. When a wire list program has been created or edited, a test file is generated by a Compile function.

Programming functions are selected through the Program category from the main screen. From the main screen, move the category highlighting bar to the Program selection, which then displays the program window as shown below.

Cablescan Series 90 I Series 90HV Copyright 1992, CABlESCAN, INC.

Run Print Program System Options r- Editor----I-------..",...&

I Compile Learn I Import I

, Load Program I 1,_, .. , .. ",_" __ , ___ ':: __ , __ ",,, "J

Page 6: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 2

To select a mode, move the scrolling bar to highlight the desired mode, and • press ENTER. The desired selection also may be executed by pressing the mtensified letter of the mode.

A separate Programming Manual provides details on how to use the Program Editor.

CROSS REFERENCE LABELS

When the Series 90 creates a wire list using Learn, the resulting wire list is saved using tester point numbers. Harness connector/pin numbers can then be entered as cross references, relating each tester point number to the corresponding harness connector/pin number. Once the cross references are entered, faults are displayed using connector/pin references.

PROGRAM FUNCTIONS

EDITOR

The Editor function is used to enter the Program Editor: Just move the highlighting bar to Editor, using the down arrow key, and press ENTER. The Program Editor takes a few seconds to load.

The Series 90 Program Editor is window-driven; its edit command categories are displayed • across the top of the screen as shown below. Selection of a category results in a window (for the category chosen), which in turn provides further selections. The category windows are opened by holding the AL T key while pressing the first letter of the category. For details on using the Program Editor, refer to the Series 90 Programming Manual.

Cablescan Series 90 Editor

Files Views Edit Print I~rt

Series 90 Directory List

Delta Production 01/24/1983 17:41:00 Delta Incoming Receiving 04/06/1987 07:32:12 Omega Final Tests 04/11/1990 10:52:26

Arrow Keys = Move Hilite F1 = Help Esc = Exit Menu Enter = Select

(Editor Screen)

Page 7: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 3

COMPILE

The Compile function is used to process the wire list after it has been edited. When a wire list program has been created or modified through the Editor, a test file must be generated ( compiled). The Compile function must be performed before the program can be used for testing.

When the compile function is executed, it applies to the program name previously loaded and displayed in the upper right corner of the screen. Use the Load Program function to load a different program for compiling. If a program has not been loaded before selecting Compile, the Load Program function automatically is executed first.

COMPILING A PROGRAM

1. Move the highlighting bar to Load Program, using the down or up arrow, and press ENTER.

2. To load a program, follow the instructions later in this section on the Load Program mode. When the program has been loaded, the program name will be displayed at the top right corner of the screen. This is the program that will be processed to generate the test file when the Compile function is selected.

3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display one of two windows:

a) IF TEST FILE ALREADY EXISTS - the highlighting bar is positioned over the Yes answer; press ENTER to compile the program.

Cablescan Series 90 / Series 90HV

Run Print Program

I Edi tor Coq:>i le

[ program name

System Options

l A compiled test file exists for this program. Compile anyway?

I No Yes

Page 8: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

b) SCREEN DURING COMPILING - if test file does not exist, compiling • window will open.

LEARN

Cablescan Series 90 I Series 90HV [ program name

Run Print Program

I Editor Compi le

Generating Test File •••

From A1J4-63 To J3-U

Warnings: Errors :

(Compiling Window)

System Options

The Learn function is used to create a wire list program automatically by scanning a completed known-good assembly and storing the continuities. The test parameters, such as the threshold value used during learn, are determined by the default settings. Once the • assembly is scanned, the monitor displays the number of continuities learned, with a check sum code. The check sum is generated according to how the continuities are arran~ed in the wire list. This code can be used to double check if two learn-known-good operatIons yield the same wire list. In addition to the check sum, the number of circuits in the wire list will be displayed.

LEARNING A KNOWN-GOOD ASSEMBLY

1. Move the highlighting bar to Load Program, using the down or up arrow, and press ENTER.

2. To load a program, follow the instructions later in this section on the Load Program mode. When the program has been loaded, the program name will be displayed at the top right corner of the screen. The learned continuities will be stored with the displayed program name.

3. Scroll up to Learn and press ENTER, or press the letter L. If a program has not previously been loaded, Load Program mode is automatically executed first. If the file name is not a new one, the warning message shown below is displayed.

Page 9: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program

Cablescan Series 90 I Series 90HV

Run Print Program

I Editor CQq)ile Learn

[ program name

System

I Replace existing test file?

I No Yes

Options

,..--------------------- 8:05:30 Use intensified letters to make your selection.

Use Mouse or Arrow Keys to Select, ~~ Enter to execute. F1 for Help

(Test File Replace Query)

PageS

4. The highlighting bar is positioned over the Yes answer. Press ENTER to run Learn, and the information screen shown below is displayed.

Cablescan Series 90 I Series 90HV

Run Print Program

I Editor CQq)ile learn

learning point:

learn range: Tester range:

Circuits:

Checksum:

[ program name

System Options

I 000213

1 - 512 1 - 512

157

43170

r--------------------- 8:05:30 Use intensified letters to make your selection.

Use Mouse or Arrow Keys to SeLect, ~ Enter to execute. Fl for Help

(Learn Information Screen)

Learning with Components

Page 10: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 6

IMPORT

The Import function is used to import wire list programs created by other means: wire lists from the Cablescan Model 512 or Model 4000; programs downloaded from CAD and saved in ASCII (Text) files; or wire list programs entered from a text editor. Once a program is imported into the Series 90 it must be processed with the compile function. When Import is selected, an Import window is opened, as shown below:

Cablescan Series 90 / Series 90HV [ program name

I Run Print Program System Options ----~---------------~ Editor

Coq:Ii le Learn I~rt ------..,

Model 4000 Program ModeL 512 Program Menu Program Text FiLe

.------------------------------------ 8:05:30 I Use intensified Letters to make your seLection.

--------------------~ Use Mouse or Arrow Keys to SeLect, 4-J Enter to execute. F1 for HeLp

(Import WindoW)

To select an Import source from the opened window, press the highlighted letter or use the arrow keys to move the scrolling bar to the desired source, and then press ENTER.

Import Sources

Model 4000 Program

This function is used to import a wire list program that was created for the Model 4000C. The program is typically imported into the Series 90 system through the 3.5-inch floppy disk since the Model 4000 does not use a DOS disk format.

Model 512 Program

This function is used to import a wire list program that was created for the Model 512. There are two ways to import Model 512 programs:

• Inserting a Model 512 3.5-inch floppy diskette into the Series 90 and running the Import Model 512 program from drive A.

• Using DOS to copy a Model 512 3.5-inch floppy diskette onto the Series 90 hard disk and then running the Import Model 512 Program from Drive C.

The Model 512 uses a DOS disk format.

Page 11: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 7

Menu Program

The Menu Program selection is used to import wire list programs that were created for the Model 4000 using the Menu program. A Menu wire list program is made up of four ASCII files: the wire list file, cross reference file, option file, and assignment file. They have file extensions of SRC, CRF, OPT, and ASN. There are two ways to import Menu programs:

• Inserting a Menu program saved on a 3.5-inch floppy diskette into the Series 90 and running the Import Menu Program from drive A.

• Using DOS to copy the Menu program from the 3.5-inch floppy diskette onto the Series 90 hard disk and then running the Import Menu Program from Drive C.

The second method is required if the Menu program is contained on multiple diskettes. If picture files are also being imported, the Menu program must be copied into a directory structure identical to the one used from which it came. The Import Menu Program from Drive C can then be run after the Menu files and picture files are copied into the appropriate directories using DOS.

Text File

The Text File selection is used to import a wire list from another source. This includes programs downloaded from CAD and saved in ASCII files, wire list programs entered from a text editor, and programs output from a database system. Refer to the back of this section for the Text File format specifications.

Running Import

The location of the program to be imported (Import-From) and the location for saving the program (Import-To) are specified through selection windows. The (Import-From) location such as drive, directory, and file name is specified first, while an "IMPORT FROM .. ," message is displayed on the lower left screen. While specifying the Import-To, location, an "IMPORT TO ... " message is displayed. Selection windows are used to specify the following import information:

IMPORT-FROM LOCATION IMPORT-TO LOCATION

III Series 90 Program Directory II 90 Program Name

Page 12: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 8

Import-From Location

The Import function must begin with specifying the Import-From Location.

1.

SPECIFYING THE IMPORT - FROM LOCATION

With the Import Category window opened, move the highlighting bar to one of the Import functions, using the down arrow, and press ENTER. A disk drive select window, as shown below, will appear.

Select Import Drive.

A: B: C: F: (Network) G: (Network)

(Drive Select Window)

2. Scroll down to the disk drive letter containing the program to be imported and press ENTER. (Model 4000 and 512 programs are imported from drive A.) Network drives will also be listed (as shown above) if the Series 90 is running on a network. A directory select window for the selected drive will then replace the drive select window. Two example directory windows are shown below; one for a disk containing multiple subdirectories, and one for a disk with only the single root directory:

C: A:

c:\ A:\ t-FNlTEST ~ARNESS ACKPlN

CBS ADAPTERS

~fVTEST UllD f-/?RAW

t::AINTBRUSH f-\:II I CTURES

PS 1 LwoRD

(Directory Select Windows)

3. Scroll down to the directory containing the program to be imported, using the down arrow, and press ENTER. A Program Select window is opened corresponding to the previous drive and directory selections.

Page 13: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 9

The programs listed in a program select window are determined by the import function selected. Model 4000 programs can be imported only from floppy diskettes. Therefore, Model 4000 selection lIsts all the programs on drive A. Model 512 and Menu Programs have specific file extensions, EHT and SRC respectively. A Model 512 selection lists programs with EHT extensions (i.e. A:\*.EHT), and a Menu Program selection lists programs with a SRC extension (C:\directory\*.SRC). Text files do not require a specific extension and therefore a Text File selection lists all files in the selected directory (C:\directory\ *. *). Program select window examples are:

A:\*.EHT C:\CABLESCN\*.SRC C:\DBASE\*.*

5120EMO MENUDEMO TEXTDEMO.TXT 5290497 5290808 5290808.DOC DEMOHARN REARHARN REARHARN.WPF DASH-PNL DASH-OPL DASH-OPL.TXT

l CHASSIS l MENUDEMO l MENUDEMO.WS

(Model 512 Programs) (Menu Programs) (Text Files)

4. Scroll down to the program to be imported, using the down arrow, and press ENTER. A Directory Listing window or a Program Listing window will be displayed for selecting the Import-To location (to save the imported program).

Import-To Location

Mter the Import-From location has been specified, Import opens either a Directory Listing window or a Program Listing window. If a program has been loaded since the Series 90 was turned on, the Directory Listing window will be displayed. If a program had been previously loaded, a Program Listing window will display a program list for the directory to which that program belongs, and the cursor will be positioned on that program.

SPECIFYING THE IMPORT - TO LOCATION

Specifying the Program Directory

The Directory Listing window displays the existing Series 90 program directories, any of which may be selected as the Import-To directory. A new directory is added by pressing the INSERT key, which opens a window for entering a directory name. The Directory Listing window is shown below:

Program Directories

Delta Incoming Receiving 04/06/1987 07:32 12 Delta Production I 01/24/1983 I 17:41 00

omega Final Tests 04/11/1990 10:52 26

(Directory Listing Window)

Page 14: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 10

1. Before a program can be imported, the Import-To directory must be selected. If the display shows a Program Listing window (as shown below) instead of the Directory Listing window, press ESC. The Directory Listing window (as shown above) win then replace the Program Listing window.

2. Scroll down to the desired directory and press ENTER, or type in the directory name and press ENTER. A Program Listing window for that directory will then be displayed.

Adding aNew Directory

1. To create a new directory selection, press INSERT. A directory name entry window will open.

2. Type the new directory name, and then press ENTER. An empty Program Listing window for that directory will then be displayed.

Specifying the Program Name

The Program Listing window displays the program names contained in a specific directory. The name under which the import program is to be saved is selected from this window. New program names are added by pressing the INSERT key, which opens a program name entry window. The Program Listing window is shown below:

Directory: Delta Production

5210932 Assembly 02/25/1984 16:40:59 5210945 Cable Assembly 05/07/1988 06:31:11 5290234 Adapter Harness 03/10/1989 09:51:25

(Program Listing Window)

L With the Program Listing window displayed, scroll down to the desired program name and press ENTER. or just type the program name and press ENTER.

To load a program from a different directory while the Program Listing window is on Listing will the

'.A.,'-""Ui<. procedure

Page 15: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 11

Adding a New Program Name

1. To create a new program name, press INSERT. A program name entry window will open.

2. Type the new program name, and then press ENTER. The wire list screen will then be displayed.

Import Window

Mter all of the Import locations have been specified, the program is imported into the Series 90 and saved to the specified program name. While importing, an Import window displays the various data types and files as the program is read into the Series 90. The data types consist of Cross References, Wire List, Program Options, etc. After the program is imported, it may be loaded into the Program Editor for editing or compiling so that it can be used by Test, Build, or Print.

The top line of the Import window displays the program Import-from location. The remaining lines display information corresponding to the function being performed. Various messages such as Creating Wire List, Reading Source file, Reading Assignment File, etc. will be displayed on the second line. The remaining lines display the actual data being read. A Import window with an example display is shown below:

Importing from A:\DEMO.EHT Creating Cross-Reference ....

Point: 8 Label: XA1-08

(Import Window)

Page 16: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 12

LOAD PROGRAM

The Load Pro~ram function is used to retrieve wire list programs from disk and load them into the tester s memory, where they are stored with 24-character file names. When numerous programs are stored on the work station, separate directories help to locate a program. Directories can be used to group programs by job, application, operator, etc.

If more than one directory is used, a directory listing window is displayed. A directory is selected by scrolling down to the desired line and pressing ENTER. A program listing window for the selected directory is then displayed. If only one directory is present, no directory list is displayed and the program list is immediately displayed. A program is loaded by moving the highlighting bar to the desired program and pressing ENTER.

The 24-character file name is then displayed at the top right corner of the screen. When the program is loaded, the options are set according to the program and default settings. Any of these changes in the options remain for the displayed program until Load Program loads another program. The options can be returned to the original settings by reloading the program.

LOADING A PROGRAM

1. Scroll the highlighting bar down to Load Program and press ENTER. (Load Program can also be executed by pressing P.) When executing the Load Program mode for the first time, a Directory Listing window is displayed, as shown below.

The directory list will be bypassed next time a program is loaded. •

Cablescan Series 90 / Series 90HV Copyright 1992, CABLESCAN, INC.

Run Print Options Program System ~----------------·~I-E-d-it-o-r----~

Campi le

Program Directories

Delta Production 01/24/1983 17:41:00 Delta Incoming Receiving 04/06/1987 07:32:12 Omega Final Tests 04/11/1990 10:52:26

r-------------------------------------- 8:05:30 Use intensified letters to make your selection.

Use Mouse or Arrow Keys to Select, ~ Enter to Execute. F1 for Help

(Directory Listing Window)

2. Scroll down to the desired directory and press ENTER. A directory also can be selected by typing in the directory name and pressing ENTER. As the name is typed, the highlighting bar automatically moves in response. The directory listing window will then be replaced with a program list window.

Page 17: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program

Cablescan Series 90 / Series 90HV Copyright 1992, CABLESCAN, INC.

Run Print Program

I Editor COIIfIile

Di rectory: Delta Production

5210932 Assembly 02/25/1984 5210945 Cable Assembly 05/07/1988 5290234 Adapter Harness 03/10/1989

System Options

16:40:59 06:31:11 09:51:25

r-------------------- 8:05:30 Use intensified letters to make your selection.

Use Mouse or Arrow Keys to Select, ~ Enter to Execute. F1 for Help

(Program Listing Window)

(To select a different directory, press ESC, and the Directory Listing window will open again, enabling a new directory selection. )

Page 13

3. With the program listing window on display, either scroll down to the desired program name and press ENTER, or type the name and press ENTER. After the program is loaded, the name will appear in the upper right corner of the screen, and the program listing window will close.

4. To load a different program:

• From the same directory - execute Load Program. The Program Selection window for the previously selected directory will open.

• From a different directory - execute Load Program and press ESC. The Directory Listing window will replace the Program Listing window. Pressing ESC a second time will terminate the Load Program mode.

Page 18: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 14

TEXT IMPORT SPECIFICATIONS

DISCUSSION

The Text File function is used to import wire list programs from other sources such as databases, CAD files, and ASCII files. Importing from these sources is accomplished through an ASCII file written in a specific format. The wire list information from other sources must be processed and saved to an ASCII file as specified below. The Text File function is then run to load the ASCII file into the Series 90. Refer to Import in this section for discussion and procedures for importing.

TEXT FILE FORMAT

A wire list program has of five types of data. Each of these five data types is written into its respective section of the ASCII file, with each type identified by its keyword enclosed in square brackets, e.g., [keyword]. The data associated with the keyword then follow. The five data-type sections of the ASCII file and their keywords are shown below:

• Wire List [WIRES]

• Cross Reference List [POINTS]

• Program Options [OPTIONS]

• Lamp Driver List [LAMPS]

• Build Operations [OPERATIONS]

A Series 90 program requires at least the Wire List and Cross Reference List. The Program Options, Lamp Driver List, and Build Operations are optional.

Each line of data has two or more fields, which are separated by commas. Fields that contain commas, such as in Operations, are additionally separated by double quotation (") characters. (Data strings within the fields cannot contain double quotation characters.) Leading and trailing spaces on each line preceding and following the data fields are disregarded. Tab and non-printing characters are converted to spaces. (When using a word processor, save the import file with its ASCII or Text-only option to remove the non-printing characters. )

Page 19: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 15

DATA FORMATS

Field formats for the five data types are described below. Wire List and Cross Reference List data are required for importing into the Series 90; the others are optional. Each data type must begin with its keyword enclosed in square brackets.

Wire List

Wire List data are required for a wire list program. The keyword is [WIRES]. Refer to the Wire List section in the Programming manual for additional information on the various fields. Each line entered in the wire list represents a continuity and consists of eight data fields as shown below.

<From>,<To>,<Comment>,<Component>,<Orientation>,<Value 1 >,<Value 2>,<Value 3>

The first three fields describe the circuit connection and are interpreted the same with or without a component in the circuit. The fourth field specifies wire only, or the type of component contained in the circuit. The fifth field is used for components, such as diodes and electrolytic capacitors, where a component direction is important. The remaining fields specify the component values and tolerances.

Comment

- specifies where the wire originates. The From field can have up to 16 alphanumeric characters.

Valid inputs: 1 to 16 alphanumeric characters

- specifies the terminating end of the wire. The To field can have up to 16 alphanumeric characters. The first character cannot have a dollar ($) sign character; it is reserved for a build only circuit which is not tested for continuity.

Valid inputs: 1 to 16 alphanumeric characters

- is used to display a 32-character comment on the second line of the build display screen. The Comment (Circuit Label) can have up to 32 alphanumeric characters.

VaHd innut~: 1 to alphanumeric

or

or

of the to

Page 20: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 16

Value Fields for Wires

The three value fields for wire (continuity) circuits are optional. When the value fields are omitted, the circuit is tested according to the values entered under Program Options [OPTIONS] as described later in this section. These value fields are specified only when a particular circuit is to be tested differently. The three fields are interpreted as follows:

Value 1

Value 2

Value 3

- specifies in scientific notation the continuity threshold for a wire component (W).

Valid inputs: 1 to 1.0E+3

- specifies in seconds the dwell time, or pause, from the time voltage is applied to the time circuit to the time continuity is tested.

Valid inputs: 0 to 9.9, in.1 increments

- specifies the applied test voltage in scientific notation.

Valid inputs: 2.0E-03 or 5.12

Value Fields for Components

The following value field specifications are for resistors (R), capacitors (C), and diodes (D). • Interpretation of the Value 1 and 2 fields depends on Value 3. If Value 3 has TOLERANCE entered, Value 1 is a nominal value and Value 2 is the tolerance. If Value 3 has RANGE entered, Value 1 is the lower limit of the value and Value 2 is the upper limit value.

Value 1

Value 2

Value 3

- specifies in scientific notation either the nominal value or lower limit of the component. Capacitors are in farads, resistors in ohms, and diodes (forward voltage drop) in volts. Components are specified as follows:

Capacitors = 5.0E-1O to 1.OE-2 Resistors = 1.0 to 9.9E+5 Diodes = 5.0E-2 to 4.8

- specifies either a tolerance in decimal or the upper value limit of the component range.

Valid inputs: Tolerance = .10 to .99 Range = (see component range above)

- specifies use of Value 1 and Value 2 fields, tolerance or range (upper and lower limits).

Valid inputs: TOLERANCE or RANGE

Page 21: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 17

• Cross Reference List

The Cross Reference List section of the file begins with the keyword [POINTS]. Cross Reference represents the interface wiring from the tester to the harness under test. The test point is where the interface wire originates at the tester. Refer to the Wire List section of the Programming Manual for a discussion of the Cross Reference List. Lines in the Cross Reference List assign tester point numbers to the reference labels entered in the wire list. One or two lamp drivers may also be assigned to each test point as well as the lamp mode, blink or steady. Each line in the Cross Reference List consists of six fields as shown below.

<Label>,<Point>,<Lamp l>,<Mode l>,<Lamp 2>,<Mode 2>

The first two fields assign a wire list reference label to a tester point number. The remaining fields assign one or two lamp drivers to the Cross Reference and specify lamp operating mode, blinking or steady state. Lamps are used in the build modes to identify assembly locations on the harness board.

Label

Point

Lampl

Model

Lamp 2

Mode 2

specifies a character string used to reference a connection on the harness or fixture (i.e., connector/pin number). It can have up to 16 characters.

Valid inputs: 1 to 16 alphanumeric characters

- specifies which test point on the rear panel of the tester is interfaced to the connection relating to the Label.

Valid inputs: 1 to 131,072

- assigns a lamp driver to the test point that will activate each time the Label is displayed during build. The lamp driver is assigned using a 16-character lamp label. Lamp labels are assigned in the Lamp List described below (under Lamp Driver List).

Valid inputs: 1 to 16 alphanumeric characters

- specifies whether the lamp operates in a blinking or a steady state mode.

Valid inputs: BLINK or STEADY

- specifies a second lamp driver to the test point.

- specifies the operating mode for lamp 2.

Page 22: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

Program Options

Program Options data are not required for a wire list program. When a program is imported without Program Options, the options are set to the system default. Refer to the Options section in the Reference Manual and to the Files and Views section in the Programming Manual. The Program Options section of the file begins with the keyword [OPTIONS]. The Program Options line of data contains six fields as shown below.

<Continuity>,<Short>,<Dwell>,<Voitage>,<Start Point>,<Titie>

Continuity

Dwell

Voltage

Start Point

- specifies in ohms the continuity threshold for the wire list program. The threshold is specified in scientific notation.

Valid inputs: 1 to 1.0E+3

- specifies in ohms the shorts threshold for the wire list program. The threshold is specified in scientific notation.

Valid inputs: 1.0E+4 to 7.5E+5

- specifies in seconds the dwell time for the applied voltage. The threshold is specified in scientific notation.

Valid inputs: 1.0E-5 to 6.7E+ 1

- specifies in volts the applied test voltage. There are currently two settings for the test voltage, 0.200 and 5.12 vdc. The threshold is specified in scientific notation.

Valid inputs: 2.0E-03 or 5.12

- specifies an offset to the tester point numbers in the Cross Reference List. Normally set to one, the Start Point can be from 1 to 131,072. When the program is compiled, the value of the Start Point number is added to each point number. This allows the program to be moved relative to the scanner boards.

Valid inputs: 1 to 131,072

- specifies a 70-character print string, which is to be printed at the top of printouts for the wire list program.

Valid inputs: 1 to 70 alphanumeric characters

Page 23: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display

7.0 Program Page 19

Lamp Driver List

The Lamp Driver List section of the file begins with the keyword [LAMPS]. Lamp Driver List assigns a lamp label to each point number that is defined as a lamp driver point .. Each line in the Lamp List consists of two fields as shown below.

<Label>,<Number>

The two fields assign a reference label (used when assigning lamps in the wire 1ist) to a tester point number. Lamps are used in the build modes to identify assembly locations on the harness board.

Label

Number

- specifies a character string used to reference the lamp on the fixture. It can have up to 16 characters.

Valid inputs: 1 to 16 alphanumeric characters

- specifies which point on the rear panel of the tester is interfaced to the lamp on the fixture.

Valid inputs: 1 to 131,072

Page 24: SERIES 90 SERIES 90HVcablescan.com/download/Manuals/Archive/Series 90...3. Scroll up to Compile and press ENTER, or press the letter C. Mter a few seconds the compiler will display