11
1 Ser[LOG] System © Reveuse absolue - fotolia.de Ser[LOG] Benefit from the expandability of the data logger Ser[LOG] and its modules and create your customized measuring staon. For professional recording and processing of your meteorological data. This brochure will guide you through the possible combinaons.

Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

1

Ser[LOG] System

© Reveuse absolue - fotolia.de

Ser[LOG] Benefit from the expandability of the data logger Ser[LOG] and its modules and create your customized measuring station. For professional recording and processing of your meteorological data. This brochure will guide you through the possible combinations.

Page 2: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

2

MeteoWare_CS _3 Client

Revision: 01.11.2016 © 2015,2016 LAMBRECHT meteo GmbH MW_CS_3_Client_Manual.doc Page 34 of 53

Graph with 4 quarter screens, each with a sensor. Here the curves for the measurement series temperature PT100, relative humidity, air pressure and precipitation can be seen. Each curve has its own Y axis. The value display on the auxiliary line, at the mouse cursor, is shown for every curve.

+ 3 x

+ 2 x

Phot

os: ©

appl

er-,

©Ls

hop-

Foto

lia.c

om

22.1

7

Expansion possibilities

Das Ser[LOG] SystemAlmost unlimited possibilities with the Ser[LOG] system family! Up to 3 AnDiMod can be connected to the data logger Ser[LOG] and up to 2 AnDiMod measuring modules can be connected to the data logger Ser[LOG]Plus. You will recive 36 analog/ 11 digital inputs. In addition there are virtuals channels which can be defined by existing formula collection, e. g. dew point calculation, air pressure reduction or by freely definable formula ► A maximum of 60 channels are supported. Numerous state-of-the-art communication channels are available (Bluetooth, GSM, FTP, e-mail, SMS, Modbus-RTU, Modbus-TCP, SDI-12 etc.). The configuration is easily done with the app "Ser[LOG] Commander".

In the extraction, provision, analysis, visualization and archiving of large amounts of data the Lambrecht app "MeteoWare CS3" supports you.

Data logger Ser[LOG] for serial sensors• 6 serial interfaces (1 x configurable as SDI-12)• 2 digital status inputs• 2 potential-free relays (status inputs for recording states)

Analog/Digital Measuring Module AnDiModfor the expansion of Ser[LOG] and Ser[LOG]Plus. With RS485 bus for further analog modules. Each measuring module contains: • 12 analoge differential channels• 3 digital channels• 6 connections for the power supply of the sensors

Data logger Ser[LOG]Pluscombined Ser[LOG] + AnDiMod in one device. • 12 analog interfaces • 6 serial interfaces (1x interface assigned to AnDiMod ·

with RS485 bus for up to 2 x AnDiMod)

Page 3: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

3

Precipitation Humidity/Temperature Air Pressure Global RadiationWind

Flexible design · outstanding versatilityMany LAMBRECHT sensors are available for the composition of your individual system solution. We have summarized the selection criteria for you in an overview. So you can easily defy the growing challenges of your daily measurement tasks.

Connectable sensors

LAMBRECHT-sensor Parameter

Ser[LOG]Plus

ID 00.95770.100 000

Ser[LOG]

ID 00.95770.100 000

AnDiMod

ID 00.95770.100000

interfaces

u[sonic] Wind serial

EOLOS-IND Weather serial

com[b] Wind serial

PREOS Wind serial

ARCO-SERIAL Wind serial

WENTO-IND Weather serial

rain[e] Serie Precioitation serial

8126 X81. Air pressure serial

8095 THP series Temp./Humidity/Air pressure

serial

16103Global radiation serial/ analog

INDUSTRY Wind analog

PRO-WEA Wind analog

15189 Precipitation analog

8093.11 Temp./Humidity

analog

8121 Air pressure analog

16106Global radition analog

© Galyna Andrushko © Jan Will © Daniel Gustavsson © Lulu Berlu © ivan kmit - Fotolia.com

Page 4: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

4

One for allSer[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom for individual adjustments to your measuring tasks: • extensibility due to modular design• high flexibility due to a multitude of configuration options• many possibilities due to state-of-the-art communication interfaces Take a look at the technical data of the connectable sensors and create your individual system solution.

Serial sensors

Combined Ultrasonic Wind Sensor u[sonic] Id-No. 00.16470.000000

Measurement range: Wind direction: 0...359,9° • Wind speed: 0...75 m/s

Range of application: -40...+70 °C (with heating -50...+70 °C) • 0...100 % r. h.Accuracy: Wind direction: < 2° (> 1 m/s) RMSE • Wind speed: ± 0.2 m/s RMSE (v < 10 m/s) • ± 2 % RMSE (10 m/s < v < 65 m/s)

Static Wind Sensor com[b] Id-No. 00.16441.004112

Measurement range: Wind direction: 0...360° • Wind speed: 0.1...50 m/s

Range of application: -40...+70 °C • 100 m/s • 0...100 % r. F.

Accuracy: Wind direction: ± 3° • Wind speed: ± 0.5 m/s ± 5 % of the meas. value

Static Weather Sensor EOLOS-IND/H Id-No. 00.16430.000002 unheated • 00.16430.010002 heated

Measurement range: Wind direction: 0...360° • Wind speed: 0.1...85 m/s • Air temperature: -40...+70 °C • Relative humidity: 0...100 % r. h. • Air pressure: 600...1100 hPa

Range of application: -30...+70 °C (unheated · under non-icing conditions) • -40...+70 °C (heated) • 0...100 m/s • 0...100 % r. F. Accuracy: Wind direction: ± 3° • Wind speed: ± 0.5 m/s ± 5 % of the meas. value • Air temperature: ± 0.8 °C (v > 2 m/s) • Relative humidity: ± 3 % (10...90 %) • ± 4 % (0...100 %) • Air pressure: ± 2 hPa (-40...+85 °C) · ± 0.5 hPa at 25 °C

Static Wind Sensor PREOSId-No. 00.16440.014002

Measurement range: Wind direction: 0...360° • Wind speed: 0.1...65 m/s

Range of application: -40...+70 °C heated • 0...100 m/s • 0...100 % r. h.

Accuracy: Wind direction: ± 3° • Wind speed: ± 0.5 m/s ± 5 % of the meas. value

Page 5: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

5

Combined Wind Sensor ARCO-SERIALId-No. 00.14581.010010

Measurement range: Wind direction: 0...360° • Wind speed: 0.3 ... 75 m/sRange of application: -30...+70 °C (unheated · under non-icing conditions) • 0...80 m/s • 0...100 % r. h.Accuracy: Wind direction: ± 1° • Wind speed: ± 2 % FS at 0.3 ... 50 m/s

Combined Weather Sensor WENTO-IND Id-No. 00.14516.210001

Measurement range: Wind direction: 0...360° • Wind speed: 0.3...75 m/s • Relative humidity: 0...100 % r. F. • Air pressure: 600...1100 hPa • Air temperature: -30...+70 °C

Range of application: -30...+70 °C heated • 0...80 m/s • 0...100 % r. h.Accuracy: Wind direction: ± 1° • Wind speed: ± 2 % FS at 0.3...50 m/s • Relative humidity: ± 3 % (10...90 %); ± 4 % (0...100 %) • Air pressure: ± 2 hPa (-30...+70 °C) • Air temperature: ± 0.8 °C

PRO ModbusId-No. 00.14523.130030 • 00.14524.100030

Measurement range: Wind direction: 0...360° • Wind speed: 0.5...75 m/s

Range of application: -40...+70 °C (heated) • 0...100 m/s • 0...100 % r. h.Accuracy: Wind direction: ± 1° • Wind speed: ± 0.3 m/s ≤ 10 m/s • ± 0.5 m/s in the range of 10...60 m/s

Weighing Precipitation Sensor rain[e]Id-No. 00.15184.000000 unheated • 00.15184.400000 heated

Measurement range: 0…20 mm/min resp. 0…1200 mm/h

Range of application: 0...+70 °C (unheated) • -40...+70 °C (heated · no icing, no snowdrift)Accuracy: ± 0.1 mm/min resp. ± 6 mm/h

Weighing Precipitation Sensor rain[e]H3Id-No. 00.15184.540020

Measurement range: 0…20 mm/min or rather 0…1200 mm/hRange of application: -40...+70 °C (no icing, no snow blowing)Accuracy: ± 0.1 mm/min or rather ± 6 mm/h

Page 6: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

6

Combined Sensor THP (8095)Id-No. 00.08095.000000

Measurement range: Temperature: -40...+70 °C • Relative humidity: 0...100 % r.h. • Barometric pressure: 500...1100 hPaAccuracy: Temperature: ± 0.3 °C at (v > 2 m/s) · ± 0.4 °C (10…40 °C) · ± 0.8 °C (-10…+70 °C) • Relative humidity: ± 3 % (10...90 %) r. h. · ± 4 % (0...100 %) r. h. • Barometric pressure: ± 2 hPa (-30...+70 °C) ± 1 hPa (-10...+60 °C)

Combined Sensor THP (8095-NAV) with membrane filter for special resistance to air pollutantsId-No. 00.08095.001000

Measurement range: Temperature: -40...+70 °C • Relative humidity: 0...100 % r.h. • Barometric pressure: 500...1100 hPaAccuracy: Temperature: ± 0.3 °C at (v > 2 m/s) · ± 0.4 °C (10…40 °C) · ± 0.8 °C (-10…+70 °C) • Relative humidity: ± 3 % (10...90 %) r. h. · ± 4 % (0...100 %) r. h. • Barometric pressure: ± 2 hPa (-30...+70 °C) ± 1 hPa (-10...+60 °C)

Pyranometer (16103) 'Second class'Id-No. 00.16103.500060

Measurement range: 0...1600 W/m2

Range of application: -40...+80 °CISO classification: Second classWMO performance level: Moderate quality

Air pressure sensor 8126 X81Id-No. 00.08126.481002

Measurement range: 35...2000 hPa

Range of application: -45...+85 °C during operation

Accuracy: ± 0.0144 % FS

Serial sensors

Pyranometer (16131.5-Modbus) 'First class'Id-No. 00.16131.501030

Measurement range: 0...3000 W/m2

Range of application: -40...+80 °CISO classification: First classWMO performance level: Good quality

Page 7: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

7

Wind Sensor INDUSTRY · incl. cableId-No. 00.14567.100180 Wind direction • 00.14577.100 180 Wind speed

Measurement range: Wind direction: 0...360° • Wind speed: 0.7...50 m/s

Range of application: -30...+70 °C (heated) • 0...60 m/sAccuracy: Wind direction: ± 2° • Wind speed: < ± 2 % FS

Wind Sensor PRO-WEA · incl. cableId-No. 00.14523.130080 Wind direction • 00.14524.100080 Wind speed

Measurement range: Wind direction: 0...360° • Wind speed: 0.5...60 m/s

Range of application: -40...+70 °C heated • max. gusts 100 m/s • 0...100 % r. h.Accuracy: Wind direction: ± 2° • Wind speed: ± 0.3 m/s ≤ 10 m/s • ± 0.5 m/s...60 m/s

Serial sensors

Analog sensors

Precipitation Sensor (15189)Id-No. 00.15189.002000 · 2 cm³ volume of tipping bucket · unheated 00.15189.402000 · 2 cm³ volume of tipping bucket · heated 00.15189.004000 · 4 cm³ volume of tipping bucket · unheated 00.15189.404000 · 4 cm³ volume of tipping bucket · heated

Measurement range: 2 cm³: 0...8 mm/min • 4 cm³: 0...16 mm/minRange of application: 0…+70 °C metering (unheated · frost resistant down to -20 °C) • -20...+70 °C (heated · no icing, no snowdrift)Accuracy: ± 2 % with intensity correction

Pyranometer (16130.5-Modbus) 'Secondary standard'Id-No. 00.16130.501030

Measurement range: 0...3000 W/m2

Range of application: -40...+80 °CISO classification: Secondary standardWMO performance level: High quality

Page 8: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

8

Pyranometer (16103) 'Second class'Ident-Nr. 00.16103.500060

Measurement range: 0...1600 W/m2

Range of application: -40...+80 °CCalibration uncertainty: < 1.8 % (k = 2)

Pyranometer (16106) · incl. cableId-No. 00.16106.000080

Measurement range: 0...1400 W/m2

Range of application: -40...+60 °CCosine error: < 10 % @ 80°

Air Pressure Sensor (8121) · incl. cableId-No. 00.08121.100002

Measurement range: 600...1100 hPa • switchable to 800...1100 hPaRange of application: Altitudes 0...4000 m • Temperatures -20...+70 °C • Humidity 0...99 % r. h. Accuracy: ± 1 hPa within the range of -10...+60 °C • < ± 2 hPa within the range of -20...-10 °C

Temperature Humidity Sensor (8093.11) · incl. cableId-No. 00.08093.110000

Measurement range: Temperature: -40...+60 °C • Relative humidity: 0...100 % r. h.

Range of application: Temperature: -40...+80 °C • Humidity: 0...100 % r. h.

Accuracy: Temperature: ± 0,2 °C at -27...+70 °C · Plus: ± 0.007 °C/ °C at: < +10 °C • > + 40 °C • Relative humidity: ± 2 % r.h. at: 5...95 % r. h. • +10...+40 °C · Plus: < 0.1 % r. h./ °C at: < +10 °C • > +40 °C

Analog sensors

Air Pressure Sensor (8128) ·Id-No. 00.08128.085072 • 00.08128.095072

Measurement range: 600...1100 hPa • 800...1100 hPaRange of application: Heights 0...3200 m • Temperatures -40...+60 °CAccuracy: ± 0,5 hPa in the range of 600...1100 hPa • ± 0,3 hPa in the range of 800...1100 hPa

Page 9: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

9

Accessories listIn the overview you will find the standard accessories you need to complete your individual weather station. We are also happy to realise your individual wishes. Just get in touch with us.

Name Id-No.. Image

Voltage supply

Mains adapter 60 W, with casing 00.14966.300000

Mains adapter 150 W, with casing 00.14966.200000

Mains adapter 240 W, with casing 00.14966.500000

Mains adapter 480 W, with casing 00.14966.600000

Kommunication and software

MeteoWare CS3 - Standard 36.09340.000000 without image

MeteoWare CS3 - Network 36.09340.100000 without image

MeteoWare CS3 - Network plus 36.09340.110000 without image

MeteoWare CS3 - Station plus 36.09340.200000 without image

Kabel

Cable for u[sonic] 10 m 32.16461.060000

Cable for EOLOS, WENTO (signal + supply) 10 m 32.16420.066100

Cable for ARCO (signal + supply) 10 m 32.14581.060000

Cable for rain[e] (signal + supply) 10 m 32.15184.060000

Additional cable for rain[e] heated, 1 m 32.15184.061000

Cable for 15189 (signal) 7 m 32.15188.060090

Additional cable for 15189 heated, 1 m 32.15188.061020

Cable for sensor THP, Modbus sensors 32.14567.060010

Installation

Aluminium tripod mast ( three-legged) 2.5 mTransport length: 1,45 m · useful length: 2.50 mPipe-Ø: 55/50 mm (Peak Ø: 50 mm) · pipe wall thickness: 2 mmaccessories included:· 3 ground spikes· Fastening material for housing 380 x 380 mm· Weight: approx. 7 kg

00.14627.000000

Aluminium telescopic mast, 3 mPeak-Ø: 50 mm

00.14627.030000 ohne Abb.

Wall bracket set, 150 mm, für 3 m aluminium telescopic mast 32.14627.030100

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

1A4

Wandhalterung

Status Änderungen Datum Name

Gezeichnet

Kontrolliert

Norm

Datum Name20.03.2014 Schönfelder

Mechanische Systeme LehmannDorfstrasse 3302629 Gnaschwitzwww. teleskopmast.de

Maßstab 1:2

Werkstoff: ALMg3

100.800110.0003a Znr. ergänzt 31.08.16 TE

Abwicklung 1:5

40

150

120°

120°

6

520,8

15140

220

345

20

8,5

2x

360

106

40

2x 11

33 33

60°

3-leg tripod base for 3 m aluminium telescopic mast 32.14627.030200

Page 10: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

10

750 mm outrigger for precipitation sensor, for 3 m aluminium telescopic mast, Ø 60 mm

32.14627.030300

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A A

B B

C C

D D

E E

F F

1 A2

750mm Halbauslegerfür Niederschlagssensor 15189

100.900200.0104Status Änderungen Datum Name

Gezeichnet

Kontrolliert

Norm

Datum Name31.08.2016 Eckert

55

Klemmbacke KB55-V100.800400.0006-V

KD60 mitInbusschraube

115

Rohr Ø60x2 300lang

Rohr Ø55x2 700lang

Fuß Ø100, 15dick

750

Aluwinkel 40x40x5

770

Stainless steel mast (earth foundation) · for separate installation of precipitation sensors 15189 and rain[e] Pipe-Ø: 60 mm · Length: 1200 mm

00.15180.400000

Mast bracket for adapter 32.14966.030000

Wei

terg

abe

sow

ie V

ervi

elfä

ltigu

ng d

iese

r U

nter

lage

, Ver

wer

tung

und

Mitt

eilu

ng ih

res

Inha

lts n

icht

ge

stat

tet,

sow

ie n

icht

aus

dück

lich

zuge

stan

den.

Zuw

ider

hand

lung

ver

pflic

hten

zu

Scha

dens

ersa

tz.

Alle

Rec

hte

für

den

Fall

der

Pate

nter

teilu

ng o

der

Geb

rauc

hsm

uste

r-Ei

ntra

gung

vor

beha

lten.

Pass

ing

on a

nd d

uplic

atio

n of

thi

s do

cum

ent,

util

izat

ion

and

com

mun

icat

ion

ofit'

s co

nten

ts p

rohi

bite

d un

less

def

inite

ly p

erm

itted

. Inf

ringe

men

t is

bou

nd t

oco

mpe

nsat

ion.

All

right

s re

serv

ed fo

r pa

tent

or

regi

ster

ed p

atte

rn.

Zust. Änderungen Datum Name Dateiname Ersatz für:

Blatt

Bl

Bearb.Gepr.

Datum Name

Artikelnummer

Benennung

32.14966.030000.idw

1 / 1

20.01.2016 Krell

32.14966.030000

Masthalterung Cube

1 A4

Norm.

Revision

Bemerkung / Bestell-Nr.BenennungSach-Nr.Anz.Pos. Halteplatte33.14966.03000011 Unterlegscheibe 6,4 DIN 125 A A435.01251.60064142 Sechskantschraube M6 x 20 DIN 933 A235.09331.53380043 Sechskantmutter M6 DIN 934 A235.09341.50060044 Fächerscheibe 6,4 DIN 6798 A A435.67981.60064145je 60 cmSpannband69.61010.21000026 Spannschloss69.61010.21010027

Baugruppe wird nicht vormontiert

Weather-resistant sheet steel housing, suitable for installation of the Ser[LOG] series as well as power supply and communication unitDimensions: 380 x 380 x 210 mm

32.95666.030000

Mast bracket for sheet steel housing 32.95666.032000

Sensor shelter · Weather and radiation protection with natural ventilationtemperature operating range: -40...+70 °CNumber of lamellas: 11 piecesDimensions: Ø = 120 mm High = 300 mm (incl. mount)For mast diameter: 25...50 mmWeight: 950 gIncluded in delivery: Screw fitting for sensor-Ø 14...21 mm

00.08141.600000

Sensor shelter · Weather and radiation protection with artificial ventilationtemperature operating range: -40...+70 °CNumber of lamellas: 15 piecesDimensions: Ø = 150 mm High = 395 mm (incl. mount)For mast diameter: 25...50 mmWeight: 1.400 gIncluded in delivery: Screw fitting for sensor-Ø 14...21 mm

00.08141.600004

Page 11: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom

11

You wish to tell us something or have a question?

Your contact person:Daniel DreilichTel: +49 551 [email protected]

LAMBRECHT meteo GmbH Friedländer Weg 65-6737085 Göttingen

Tel: +49 551 4958-0 www.lambrecht.net

Weather and radiation protection shelter 8141.6 TSfor traverse system

00.08141.610000

Set wind traverse consisting of:· 1 x 33.14627.001010 Traverse 750 mm· 1 x 32.14627.007000 · 1 x 32.14627.007000 2x Cover cap· 2 x 32.14627.002000 Holder parts WIND· 1 x 32.14627.001000 Mast bracket

32.14627.010000

Set traverse for pyranometer and TH consisting of:· 1 x 33.14627.001000 Traverse 1000 mm· 1 x 32.14627.007000 2x Cover cap· 1 x 32.14627.002000 Holder parts WIND· 1 x 32.14627.003000 Holder parts RADIATION· 1 x 32.14627.004010 Holder parts SENSOR SHELTER· 1 x 32.14627.001000 Mast bracket

32.14627.011000

Set Traverse for pyranometer and sensor shelter TS consisting of:· 1 x 33.14627.001000 Traverse 1000 mm· 1 x 32.14627.007000 2x Cover cap· 1 x 32.14627.003000 Holder parts RADIATION· 1 x 32.14627.001000 Mast bracket

32.14627.011010

Other accessoriesLightning rod 32.14565.019000

1 2 3 4

Fächerscheibe Mutter

Blitzschutzstab

Masthalterung

Bohrung B5 oder B6

B4B3

B6

B1 B2

B5

Mast Ø

InstallationsanweisungBlitzschutzstab

Technische Änderungen vorbehalten

Benötigtes Werkzeug ■ Ring-/Maulschlüssel oder Steckschlüssel o SW17 Mutter (Blitzschutz)

Da die Montage i. d. R. in großen Höhen statt ndet, muss das Montagepersonal bei der Installation die betreffenden Sicherheitsbestimmungen beachten.

Installieren des Blitzschutzstabes

32.14565.019000 Blitzschutzstab 1 Blitzschutzstab2 Fächerscheiben 10,42 Muttern M10

Beispiel: Montage der Blitzschutzstange an der MasthalterungDie Bohrungen B5 und B6 der Masthalterung 32.14627.001000 sind für die Montage einer opti-onalen Blitzschutzstange vorgesehen. Siehe auch "Installationsanweisung Traversen-System".

LAMBRECHT meteo GmbH Tel +49-(0)551-4958-0Friedländer Weg 65-67 Fax +49-(0)551-4958-31237085 Göttingen E-Mail [email protected] Internet www.lambrecht.net

14.16Quality System certified by DQS according toDIN EN ISO 9001:2008 Reg. No. 003748 QM08

WiFi router 00.90251.000000 (not illustrated)

Ground terminal block 4 x 3 32.14966.015000 (not illustrated)

Bracket for mast (for wind sensors INDUSTRY and PRO-WEA) 32.14627.001010 (not illustrated)

Micro SD card 8 GB (-25...+85 °C) · industrial standard 32.95800.010000 (not illustrated)

Wall bracket THP (indoor) 32.14629.010000 (not illustrated)Technische Änderungen vorbehaltenLAMBRECHT meteo GmbH Tel +49-(0)551-4958-0

Friedlaender Weg 65-67 Fax +49-(0)551-4958-31237085 Goettingen E-Mail [email protected]

Traversensystem 14627

25.15

Set Windtraverse32.14627.010000bestehend aus:1x 33.14627.001010 Traverse 750 mm1x 32.14627.007000 Set Abdeckkappen2x 32.14627.002000 Set Sensorhalterung, rund D301x 32.14627.001000 Set Masthalterung

Set Traverse für Pyranometer und TH32.14627.011000bestehend aus:1x 33.14627.001000 Set Traverse 1000 mm1x 32.14627.007000 Set Abdeckkappen1x 32.14627.002000 Set Sensorhalterung, rund D301x 32.14627.003000 Set Sensorhalterung, groß1x 32.14627.004010 Set Befestigungszapfen 100mm.1x 32.14627.001000 Set Masthalterung

Set Traverse für Pyranometer und Wetterhütte TS32.14627.011010bestehend aus:1x 33.14627.001000 Set Traverse 1000 mm1x 32.14627.007000 Set Abdeckkappen1x 32.14627.003000 Set Sensorhalterung, groß1x 32.14627.001000 Set Masthalterung

3-Bein-Teleskopmast 2,5 m Aluminium00.14627.000000