RESEARCH POSTER PRESENTATION DESIGN © 2011 www.PosterPresentation s.com Cardiovascular Sensing A strong need for continuous, non interfering blood pressure measurements: Ambulatory Blood Pressure Measurements (ABPM) No current commercial product satisfies this need Hypertension affects 25% of the worlds population 1 in every 8 deaths is due to uncontrolled hypertension First product focus is non- interfering 24 hours ABPM Problem Technology Product A disposable patch Miniaturized electronics for excitation, collection, processing, storage and transfer/ transmission of data Optional reader (transceiver) device Dedicated software A 510 (k) is most likely adequate (according to an independent US consultant) Usage Contact David B. Bæk, [email protected] Lars Lading, [email protected] Distension from impedance sensing Arterial dimensions by multifrequency excitation: permittivity and conductivity of different tissues exhibit different frequency dependencies Arterial stiffness from pulse wave velocity Differential pressure from distension and stiffness Absolute pressure from functional relation: vessel diam. vs. pressure Distension Stiffness No counter pressure The method is model based! No wire – or hose – connections to external devices Disposable patch: no cross-contamination Why is this not common practice? Because arterial distension is (has been) difficult to measure and Arterial stiffness has been almost impossible to measure at a single location Key Features www.sense-as.com Sense A/S ContiPress™ 1) 2) 3) 4) 5) Sense A/S January 2012

Sense A/S ContiPress™ - Medgadget...RESEARCH POSTER PRESENTATION DESIGN © 2011 s.com Cardiovascular Sensing A strong need for continuous, non interfering blood pressure

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • RESEARCH POSTER PRESENTATION DESIGN © 2011

    www.PosterPresentations.com

    Cardiovascular Sensing

    �A strong need for continuous, non interfering blood pressure measurements: Ambulatory Blood Pressure Measurements (ABPM)

    �No current commercial productsatisfies this need

    �Hypertension affects 25% of the worlds population

    �1 in every 8 deaths is due to uncontrolled hypertension

    �First product focus is non-interfering 24 hours ABPM

    Problem

    Technology

    Product

    � A disposable patch

    �Miniaturized electronics for excitation, collection, processing, storage and transfer/ transmission of data

    � Optional reader (transceiver) device

    � Dedicated software

    � A 510 (k) is most likely adequate (according to an independent US consultant)

    Usage

    Contact

    David B. Bæk, [email protected]

    Lars Lading, [email protected]

    �Distension from impedance sensing

    � Arterial dimensions by multifrequency excitation: permittivity and conductivity of different tissues exhibit different frequency dependencies

    � Arterial stiffness from pulse wave velocity

    �Differential pressure from distension and stiffness

    � Absolute pressure from functional relation: vessel diam. vs. pressure

    � Distension

    � Stiffness

    � No counter pressure

    � The method is model based!

    � No wire – or hose – connections to external devices

    � Disposable patch: no cross-contamination

    Why is this not common practice?

    �Because arterial distension is (has been) difficult to measure and

    �Arterial stiffness has been almost impossible to measure at a single location

    Key Features

    www.sense-as.com

    Sense A/SContiPress™

    1) 2)

    3)

    4)

    5)