1
RESEARCH POSTER PRESENTATION DESIGN © 2011 www.PosterPresentation s.com Cardiovascular Sensing A strong need for continuous, non interfering blood pressure measurements: Ambulatory Blood Pressure Measurements (ABPM) No current commercial product satisfies this need Hypertension affects 25% of the worlds population 1 in every 8 deaths is due to uncontrolled hypertension First product focus is non- interfering 24 hours ABPM Problem Technology Product A disposable patch Miniaturized electronics for excitation, collection, processing, storage and transfer/ transmission of data Optional reader (transceiver) device Dedicated software A 510 (k) is most likely adequate (according to an independent US consultant) Usage Contact David B. Bæk, [email protected] Lars Lading, [email protected] Distension from impedance sensing Arterial dimensions by multifrequency excitation: permittivity and conductivity of different tissues exhibit different frequency dependencies Arterial stiffness from pulse wave velocity Differential pressure from distension and stiffness Absolute pressure from functional relation: vessel diam. vs. pressure Distension Stiffness No counter pressure The method is model based! No wire – or hose – connections to external devices Disposable patch: no cross-contamination Why is this not common practice? Because arterial distension is (has been) difficult to measure and Arterial stiffness has been almost impossible to measure at a single location Key Features www.sense-as.com Sense A/S ContiPress™ 1) 2) 3) 4) 5) Sense A/S January 2012

Sense A/S ContiPress™ - Medgadget · Absolute pressure from functional relation: vessel diam. vs. pressure Distension Stiffness No counter pressure ... Sense A/S ContiPress

  • Upload
    ngoanh

  • View
    214

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Sense A/S ContiPress™ - Medgadget · Absolute pressure from functional relation: vessel diam. vs. pressure Distension Stiffness No counter pressure ... Sense A/S ContiPress

RESEARCH POSTER PRESENTATION DESIGN © 2011

www.PosterPresentations.com

Cardiovascular Sensing

�A strong need for continuous, non interfering blood pressure measurements: Ambulatory Blood Pressure Measurements (ABPM)

�No current commercial productsatisfies this need

�Hypertension affects 25% of the worlds population

�1 in every 8 deaths is due to uncontrolled hypertension

�First product focus is non-interfering 24 hours ABPM

Problem

Technology

Product

� A disposable patch

�Miniaturized electronics for excitation, collection, processing, storage and transfer/ transmission of data

� Optional reader (transceiver) device

� Dedicated software

� A 510 (k) is most likely adequate (according to an independent US consultant)

Usage

Contact

David B. Bæk, [email protected]

Lars Lading, [email protected]

�Distension from impedance sensing

� Arterial dimensions by multifrequency excitation: permittivity and conductivity of different tissues exhibit different frequency dependencies

� Arterial stiffness from pulse wave velocity

�Differential pressure from distension and stiffness

� Absolute pressure from functional relation: vessel diam. vs. pressure

� Distension

� Stiffness

� No counter pressure

� The method is model based!

� No wire – or hose – connections to external devices

� Disposable patch: no cross-contamination

Why is this not common practice?

�Because arterial distension is (has been) difficult to measure and

�Arterial stiffness has been almost impossible to measure at a single location

Key Features

www.sense-as.com

Sense A/SContiPress™

1) 2)

3)

4)

5)

Sense A/S

January 2012