  • Hydrogen sulfide Gas Sensor Model Number #SS1198

    - PRODUCT DESCRIPTION -The SS1198 hydrogen sulfide gas sensors operate using well known fuel cell technology (Amperometric type). The SS1198 H2S gas sensor can detect H2S gases by taking out the energy generated by the redox reactions (oxidation/reduction) as electric energy. The SS1198 H2S gas sensors offers good, reliable detection performance and has various features that can not be expected for the conventional catalytic and semiconductor type sensors

    1) Linear outputs to gas concentrations2) Excellent reproducibility3) Excellent gas selectivity4) Low humidity dependency5) Least power consumption for battery-operated detectors6) Small-sized and light-weight for portable detectors

    DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

    Better Safety Better Life For further information: +82-33-641-1711 South Korea+83-33-641-3711 (FAX)E-mail: [email protected]

    6.75

    ReferenceElectrode

    13.5

    BOTTOM view

    Form gasket(Silicon pad)

    16.5

    0.

    3

    1.45

    4.5 0.3

    SIDE view

    100

    .5

    TOP view

    200.5SENKO label

    1.95 Sensing Electrode

    Counter Electrode

    - APPLICATIONS - Ideal for portable instrument Industry safety (Petrochemical, Refineries) Sewers, Wastewater treatment, Mining etc.

    - OUTLINE DIMENSION -

  • N. B. All performance data is based on conditions at 20, 60% RH, and 1atm

    - SPECIFICATIONS -

    Hydrogen sulfide Gas Sensor Model Number #SS1198

    DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

    Better Safety Better Life For further information: +82-33-641-1711 South Korea+82-33-641-3711 (FAX)E-mail: [email protected]

    - Temperature effects -

    Weight :Storage life :

    storage temperature :Warranty period :

    Sensor Type :Measurement Range :

    Temperature Range :Pressure Range :

    Operating Humidity :Long term drift :

    Expected Operating Life :Output signal :

    Resolution :T90 Response Time :

    Output linearity :Bias voltage :

    Electrochemical sensor (Amperometric type)0 ~ 500ppm H2S gas

    24 months and more 0.60 0.15A/ppm0.1ppm< 30 seconds for 90% responseLinearNot required

    -20 ~ 50 Atmospheric 10% 15 ~ 90 % RH (non-condensing)Less than 5% /year

    6g6 month0~20 24 month

    0 10 20 30 40 50

    0

    20

    40

    60

    80

    100

    120

    140

    Output (% of signal at 20oC)

    Temperature (oC)

    - Humidity effects -

    20 30 40 50 60 70 80

    0

    20

    40

    60

    80

    100

    120

    140

    Output (% of signal at 60%)

    Humidity (%)

  • - Cross sensitivity -

    Hydrogen sulfide Gas Sensor Model Number #SS1198

    DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

    Better Safety Better Life For further information: +82-33-641-1711 South Korea+82-33-641-3711 (FAX)E-mail: [email protected]