13
Self-compensated 3 He-K magnetometer for CPT tests T. Kornack, I. Kominis, M. Romalis Princeton University J. Allred, R. Lyman University of Washington DAMOP 2002 14:24, 29 May 2002; C4.003 Work supported by NSF, NIH, NIST, Packard Foundation, and Princeton University

Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Self-compensated 3He-K magnetometer for CPT tests

T. Kornack, I. Kominis, M. RomalisPrinceton University

J. Allred, R. LymanUniversity of Washington

DAMOP 200214:24, 29 May 2002; C4.003

Work supported by NSF, NIH, NIST,Packard Foundation, and Princeton University

Page 2: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Overview

� High sensitivity potassium magnetometer� Direct sensitivity measurements� Gradient measurements and relative sensitivity

� Test of CPT Symmetry� The 3He-K co-magnetometer� Behavior of the co-magnetometer� Self-compensating operation

� Coherent interaction of electron and nuclear spin ensembles

Page 3: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Magnetometers and Spin-Exchange Relaxation

� State-of-the-art magnetometers:� use K or Rb at a low density ∼ 109 cm−3 in a large cell, 10 - 15 cm.� obtain a linewidth of ∼ 1 Hz.� are fundamentally limited by spin-exchange relaxation.

[D. Budker (Berkeley); E. Aleksandrov (St. Petersburg)]

⇒ Spin-exchange relaxation is eliminated in low field and high pressure!

10 20 30 40 50Chopper Frequency (Hz)

in phaseout of phase

-0.1

0.0

0.1

0.2

Loc

k-in

Sig

nal (V

rms)

� Using K at high density ∼ 1014 cm−3

in a small, 2.5 cm cell.

⇒ Measured linewidth 1/T2 = 1.1 Hzdominated by spin-destruction collisions and

wall relaxation

� Unaffected by spin exchange 1/TSE =20 kHz

Page 4: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

The Potassium Magnetometer

¬/4

High PowerDiode Laser

Probe Beam

Pump Beam Field Coils

Oven

Cell

Magnetic Shields

x

zy

To computer

Photodiode

Lock-in Amplifier

Calcite Polarizer

Single Frequency

Diode LaserFaraday

Modulator

SK

By

Pump, ß+

Pro

bePr

obe

� External fields are zeroed out with coils.

� Pump laser polarizes potassium.

� Probe laser detects the tilt of the K polarization in a y magnetic field.

� Faraday rotation of the probe beam used for detection.

Page 5: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Potassium Magnetometer Sensitivity

� Applied 700 fTrms modulationat 10, 20, 30 and 40 Hz:

⇒ Measured δB = 10 fT/√

Hz� More sensitive than High Tc SQUIDs:

δB = 30 fT/√

Hz

� Less sensitive than Low Tc SQUIDs:

δB = 1 fT/√

Hz

Hz)

Noi

se s

pect

rum

(V

rms /

0 10

10-2

10-3

20 30 40 50Frequency (Hz)

� Measurement limited by Johnson noise currents flowing in the shields:

I =

√4kT∆fR

→ δB = 7± 2 fT/√

Hz

� Shot noise limit is much lower:

δB =1

γ√nT2V t

= 0.002 fT/√

Hz

� How can we get down to the shot noise limit?? Differential measurement.? Superconducting shields.

Page 6: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Magnetic Gradient Imaging

� How can we suppress the Johnson current noise and improve sensitivity?

� Using:1. Higher buffer gas pressure→ Reduces diffusion and

wall relaxation

2. Higher K densityHigher polarization pumping rate→ Increases bandwidth

3. Differential measurement→ Suppresses noise

� Predicted sensitivity:δB ∼ 0.1 fT/

√Hz

� A single probe beam samplesmany points in the cell:

Faraday Modulator

Linear Polarizer

Multi-ChannelDetector

PumpLaser

Probe Laser

S

LinearPolarization

CircularPolarization K+He

B

Gas Cell

� Sensitive to heart and brain electrical activity.

� In imaging applications, a single cell can replace an array of SQUIDs.

Page 7: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

A Test of CPT Symmetry

� CPT symmetry is exact in the Standard Model, a local field theory.

� CPT symmetry may be violated:� in String Theory or Quantum Gravity� if Lorentz symmetry is otherwise broken

� CPT violation is a vector interaction:

L = −bµψγ5γµψ = −biσi

where σi are the Pauli spin matrices.

� Interacts with spins like a magnetic field.� Presumably bi interacts with different particles differ-

ently from a magnetic field.

bi

⇒ A co-magnetometer with two spin species is sensitive to such a field.� Signal would appear as a diurnal signal.

� Expected sensitivity: bei = 10−30 GeV, bni = 10−33 GeV(Using present sensitivity δB = 10 fT/

√Hz)

� 100 times more sensitive than existing limits.� Potentially much better!

Page 8: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

The 3He-K Co-Magnetometer

� Use a 3He buffer gas in our K magnetometer:

I3He

M3He, µ3He

SK

BzMK ,µK Spin-exchange

Pump, ß+

� 3He is polarized by spin-exchange with polarized K.

� Introduce an axial field Bz:� to cancel the magnetization field of the 3He, Bz = − 8π

3 κ0M3He,so that the K magnetometer operates near zero field.

� to reduce T1 relaxation of 3He polarization due to field gradients.

Page 9: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Co-Magnetometer Self-Compensated Operation

� Introduce a perturbative field (here, Bx):

BzBxBz

(a) 3He cancels the external field Bz (b) 3He compensates for Bx

I3HeM3He Bz

SKMK

I3He

M3He

B

SKMK

K feels no changeK feels no field

� The 3He spins adiabatically track the fieldand the aggregate 3He magnetization maintains field cancellation.

⇒ K atoms are insensitive to B field perturbations!

� The magnetometer does not compensate for (CPT violating) bi fieldsbecause bi interacts with 3He and K spins differently.

Page 10: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Co-Magnetometer Perturbation Response

� Apply square wave perturbation field By,focus on DC response:

0 5 10 15 20 25Time (s)

-10

-5

0

5

10

K R

espo

nse

(arb

.)

0

1

2

3

4

App

lied

Fie

ld (

µG)Bz = 0.529 mG

Slightly UncompensatedBz = 0.536 mG

Compensated

⇒ No steady-state variation in K signal dueto perturbation; fully compensated

� Apply sine wave pertur-bation field By, analyzetransient response:

Frequency (Hz)0 20 40 60 80 100

0.0

0.5

1.0

1.5

2.0

2.5

3 He-

K M

agne

tom

er F

requ

ency

Res

pons

e (V

)

3He resonance

K resonance

Self-compensation

⇒ Fully compensated forf → 0.

Page 11: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Coupled Spin Ensembles

� Apply a step field perturbation and tune Bz for compensation:

-1.5

-1.0

-0.5

0.0

0.5

1.0

K S

igna

l (a

rb.)

Near FullCompensation

UncompensatedUncompensated

Short T2

Time (s) Time (s) Time (s) Time (s) Time (s)

� Why does T2 → 0 in fully compensated mode?� The field seen by K is BK

z = Bz +Mz, which is close to zero.⇒ 3He and K spin systems are coupled when the field seen by the electron

is so low that their precession frequencies resonate; ωK/ω3He → 1.⇒ When the 3He and K spin systems resonate, the transverse motion of

3He spin is dissipated by the much faster relaxation of K.

� The red line is given by Bloch equations with a coupling term proportionalto the product of the 3He and K magnetizations.

� All data fit to a single set of parameters.

Page 12: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Modeling Coupled Spin Ensembles

� Summarizing the previous data, we plot frequency response:

0.9 1.0 1.1 1.2 1.41.3

3

2

1

0

4

5

6

7

8

External Magnetic Field Bz (mG)

Fre

quen

cy R

espo

nse

(Hz)

3He response

K r

espo

nse

� The data clearly indicate a resonance where the K and 3He precessionfrequencies converge.

Page 13: Self-compensated 3He-K magnetometer for CPT testsphysics.princeton.edu/romalis/CPT/presentations/CPT Violation DAMOP 2002.pdf · in String Theory or Quantum Gravity ... The magnetometer

Summary

� We have demonstrated:� a K sensitive magnetometer? unaffected by spin-exchange

� a 3He-K co-magnetometer? effectively compensates for magnetic fields? reduces noise at low frequency

� We will perform a test of CPT symmetry using this facility.