Upload
vuhanh
View
217
Download
0
Embed Size (px)
Citation preview
Ins
tall
ati
on
In
str
uc
tio
ns
Ins
tall
ati
on
In
str
uc
tio
ns
(In Toronto Area only: 1-905-3061093)
Certified to comply with ASME A112.19.2M
© 2009 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
SELECTRONIC™PROXIMITY CONCEALEDURINAL FLUSH VALVE1.0 & 0.5 GPF
Concealed Flushometerfor 3/4" Top or Back Spud Urinals
CLOG RESISTANT• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and !ush valves.• Range can be adjusted manually or with optional remote control.• Sensor Features Low Battery Indicator.
M968547 REV. 1.3
To learn more about American Standard Faucets visit our website at: www.americanstandard-us.comor U.S. customer's e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
6061.3106062.310 6063.3106061.2106062.210 6063.210
6061.3056062.305 6063.3056061.2056062.205 6063.205
MODEL NUMBERS
All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
9
1
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR ACLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS FOR CHROME PLATED ITEMS:
8a. AC Power Supply [Model# 6062]8b. DC Power Supply8c. 10’ Extension Wire for Multi-AC9. Installation Instructions
1. Flush Valve Assembly2. Electrical Box3. Cover Plate with Sensor4. Supply Stop5. Sweat Solder Adapter
6. Manual Override Hoses
7a. Vacuum Breaker Flush Connection (Top Spud)
7b. Vacuum Breaker Flush Connection (Wall-Mount Back Spud)
7a
8a 8b 8c
7b
3
2
4
5
DO NOT REMOVE PROTECTIVE FILM FROM SENSOREYE UNTIL INSTALLATION IS COMPLETE.
T O P
1
6
Ins
tall
ati
on
In
str
uc
tio
ns
Ins
tall
ati
on
In
str
uc
tio
ns
(In Toronto Area only: 1-905-3061093)
Certified to comply with ASME A112.19.2M
© 2009 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
SELECTRONIC™PROXIMITY CONCEALEDURINAL FLUSH VALVE1.0 & 0.5 GPF
Concealed Flushometerfor 3/4" Top or Back Spud Urinals
CLOG RESISTANT• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and !ush valves.• Range can be adjusted manually or with optional remote control.• Sensor Features Low Battery Indicator.
M968547 REV. 1.3
To learn more about American Standard Faucets visit our website at: www.americanstandard-us.comor U.S. customer's e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
6061.3106062.310 6063.3106061.2106062.210 6063.210
6061.3056062.305 6063.3056061.2056062.205 6063.205
MODEL NUMBERS
M968547 REV. 1.3
RECOMMENDED TOOLS; Fig. 2 Fig. 21.2.3.4.5.6.7.8.9.
10.
Teflon Tape Flat Blade ScrewdriverAdjustable Wrench Tape Measure HacksawTubing CutterFileFor Sweat Connection; Solder and Torch2.5mm Hex Wrench1.5mm Hex Wrench
1 2 3
4
56
7 9 10
8
PRIOR TO INSTALLATIONNote: Prior to installing the Selectronic™Flush Valve the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
• Flush all water lines prior to operation (See Step 4). Dirt and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling!
• Protect the chrome or special finish on chrome plated items.DO NOT USE toothed tools on finished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual.
• This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
IMPORTANT:• All plumbing must be installed in accordance with applicable codes and regulations.
• Water supply lines must be sized to provide an adequate volume of water for each fixture.
2
Fig. 1Roughing-in Dimensions
GENERAL DESCRIPTION:
10'
Concealed Flushometerfor 3/4" Spud Fixtures
SELECTRONIC™PROXIMITY URINALFLUSH VALVE
60mm(2-3/4) DIA.
25mm(1) MAX.
160mm(6-1/4)
OVERRIDEBUTTON
160mm(6-1/4)
305mm(12) REF.
127X127mm(5X5 CUTOUT
FOR BOX)
FOR LOCATION OF INLETSUPPLY ON BACK INLET FIXTURES,
REFER TO FIXTURE BEING INSTALLEDFOR CORRECT HEIGHT FROM
FINISHED FLOOR
FOR 3/4 TOPSPUD FIXTURE
FINISHED FLOOR
FINISHED WALL
BACK SPUDFIXTURES
TOP SPUDFIXTURES
SENSOR
115mm-134mm(4-1/2 TO 5-1/4)
*Note: The Critical Line (-C-L-) on VacuumBreaker must typically be 6" (152mm) min.above fixture. Consult Codes for details.
-C-L-*
WALL THICKNESS
32mm(1-1/4) DIA.
32mm(1-1/4DIA.)
-C-L-
SUPPLYDN 19mm(3/4) I.P.S. 51mm (2)
+ WALL THICKNESS
114mm(4-1/2) MAX.
73 TO 137mm(2-7/8) MIN. TO5-3/8) MAX.
292mm (11-1/2) MAX.
152mm(6) MIN.
403 TO 441mm(15-7/8) MIN. TO
(17-3/8) MAX.
Exclusive, self cleaning piston-type flush valve with proximity operation and manual override. Operates on DC (batter y)or AC power. Recommended operating pressure 25psi (flowing) to 80 psi (static). Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control.
M968547 REV. 1.3
Fig. 4
Fig. 3a
Fig. 5
3
INSTALL ELECTRICAL BOXASSEMBLY; Fig. 31. Cut a 127x127mm (5"x 5") opening in finished wall for ELECTRICAL BOX (1) at the deminsion shown in Fig.3.
2. Rotate the 4 MOUNTING TABS (2) flat against the electrical box. Holding the MOUNTING TABS (2) in position install the ELECTRICAL BOX (1) into the opening.Make sure the MOUNTING TABS (2) are behind the wall.
3. Tighten the the 4 MOUNTING SCREWS (3) until the ELECTRICAL BOX (1) is almost secure in the wall. Before tighting fully rest a level at the top edge of the ELECTRICAL BOX (1) and make sure the box is level, then tighten fully. Fig. 3a.
4. *Cut a 2" hole for supply to fixture at deminsion shown.
1 Fig.3 (TOP SPUD FIXTURE ILLUSTRATED)
1
3
2
2
1
1
1. Open SUPPLY STOP (1).
3. Turn on water supply to flush line of any debris orsediment.
4. Close SUPPLY STOP (1) and turn off water supply line.
FLUSH OUT SUPPLY LINES; Fig. 53
?mm(?)
*FOR HOLE LOCATION OFSUPPLY ON BACK INLETFIXTURES, REFER TO FIXTUREBEING INSTALLED FOR CORRECTHEIGHT FROM FINISHED FLOOR
127mm(5)
*114mm(4-1-2) MAX.
305mm(12) REF.
127mm(5)
INSTALL SWEAT SOLDERADAPTER; Fig. 4CAUTION Turn water supplies off
before beginning
Note: Control stop inlet is 1" IPS. For optional sweat connection, install Sweat Solder Adapter (1) (Supplied) for 1" copper pipe supply line. Fig. 4.
1. Clean the end of the supply pipe. Push the threaded ADAPTER (1) on until it is seated against the internal stop. Sweat the ADAPTER (1) to the pipe.
2. From behind the wall install the CONTROL STOP (2) to the water supply line with the outlet positioned as required.
3. Support piping as required.
2
T O P
FILEEDGES
CLEAN & SOLDER TO ADAPTER (1)
115mm-134mm(4-1/2 TO 5-1/4)
CONTROL STOPDN 25mm(1" I.P.S.)
CONTROLSTOP
OUTLET
CLOCKWISE CLOSESCONTROL STOP
COUNTER-CLOCKWISEOPENS CONTROL STOP
T O P
T O P
2
M968547 REV. 1.3
4
Fig. 6
Fig. 6a
Fig. 6b
Fig. 6c
1
23
43/4" TOP SPUD
88a
13 1512
11
6a 7
7a5
69
FLANGE END UP
FLANGE END
10
10
16
14
BACK SPUDINSTALLATION
TOP SPUDINSTALLATION
TOP SPUDINSTALLATION
2
34 INSTALL VACUUM BREAKER ANDFLUSH CONNECTIONS; Fig. 64
1. Place the SPUD FLANGE (1) over the spud on the Fixture. Fig. 6.
2. Thread SPUD COUPLING NUT (2) onto Spud. Make sure SEAL WASHER (4) and FRICTION WASHER (3) are installed. Do not tighten fully. Fig. 6.
3. Remove the COUPLING NUTS (6) from the CHROME ELBOW (5). Make sure there are a RUBBER (7) & FIBER GASKET (8) in each. Fig. 6a.
4. With the flange end up slide the FIBER GASKET (8) and COUPLING NUT (6) onto the DOWN TUBE (9). Place the RUBBER GASKET (7) onto the flange. Now connect the COUPLING NUT (6) to the CHROME ELBOW (5) and tighten fully. Insert the DOWN TUBE (5) with CHROME ELBOW (5) into the SPUD COUPLING NUT (2) and push it down. Do not tighten fully. Fig. 6a. Note: If center line of ELBOW (5) does not line up with hole in wall, then you may cut DOWN TUBE (9).
5. Replace COUPLING NUT (6a), RUBBER (7a) and FIBER GASKET (8a) on CHROME ELBOW (5), do not tighten. Fig. 6a.
6. Measure and cut the HORIZONTAL TUBE (10) to length required. Important: Make sure that there is a minimum of 1-1/4 for engagement with coupling when making your measurement. Assemble the BRASS ELBOW (11) to the HORIZONTAL TUBE (10). Fig. 6b.
7. With the flange end toward the BRASS ELBOW (11) slide the FIBER GASKET (12) and COUPLING NUT (13) onto the HORIZONTAL TUBE (10). Place the RUBBER GASKET (14) between the flange and the BRASS ELBOW (11) and tighten assembly fully. Fig. 6b.
8. From behind the wall install the ELBOW AND TUBE ASSEMBLY (11, 10) through the hole in the wall. Install WALL ESCUTCHEON (15) onto HORIZONTAL TUBE (10). Push the tube into the CHROME ELBOW (5), do not tighten coupling nut fully. Fig. 6b.
For back spud installations: Follow steps #1 and #2 to install the spud coupling kit. Push the HORIZONTAL TUBE (10) into the spud connection on the back of the fixture. Do not tighten fully. If spud coupling kit is not required install HORIZONTAL TUBE (10) into back spud on fixture and hand tighten. Fig. 6b.
10. All installations: If required cut scored VACUUM BREAKER PIPE (16) to fit, leave a minimum of 1-1/4 (32mm) of pipe to ensure engagement with compression coupling. Install VACUUM BREAKER PIPE (16) into BRASS ELBOW (11) and hand tighten coupling nut. Fig. 6c. Note: If cutting VACUUM BREAKER PIPE (16) to size, note that Critical Line (C/L) on Vacuum Breaker must typically be 6" (152mm) above fixture. Consult Code for details.
BACK SPUDINSTALLATION
11
M968547 REV. 1.3
7
9
6
25
810
Fig. 9
Fig. 8
5
7
1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8.Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape.
INSTALL FLUSH VALVE; Fig. 85
1. Align the FLUSH VALVE (2) (Fig. 9) directly above the VACUUM BREAKER TUBE (7) and VACUUM COUPLING NUT (6). Make sure that GASKET (10) is installed.Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for the 121mm (4-3/4) dimension. Fig. 9.
2. Pull the VACUUM BREAKER TUBE (7) up to meet the threaded FLUSH VALVE CONNECTION (8) and hand tighten the COUPLING NUT (6). Align all components of the flush valve assembly. Fig. 9.
3. Lightly tighten the COUPLING NUT (5) connection first, then the VACUUM BREAKER COUPLING NUT (6) and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten all couplings to make water tight connections. Fig. 9.
4. Secure piping behind wall as required.
CONNECT FLUSH VALVE TOPIPING; Fig. 9
6
3
25
1
4
121mm,+13mm, -6mm(4-3/4)(+1/2, -1/4)
M968547 REV. 1.3
6
11
6
1. Remove the four COVER SCREWS (1) and COVER from (2) ELECTRICAL BOX (4). Fig. 10.
2. Pull the CIRCUIT BOARD (3) out from ELECTRICAL BOX (4). Fig. 10.
3. Knock out lower blank in ELECTRICAL BOX (4) with flat blade screwdriver. Install from the back of ELECTRICAL BOX (4) the POWER SUPPLY GROMMET (8). Fig. 10a.
4. Attach the SAFETY CHAIN (5) from the FRONT PANEL (6) to the MOUNTING POST (7) as shown.Feed the Red and Black wires through the back opening in the ELECTRICAL BOX (4). Fig. 10a.
5. From back of ELECTRICAL BOX (4) remove SPLIT PLUG (8a) from POWER SUPPLY GROMMET (8). Insert POWER CORD CONNECTOR (9) through POWER SUPPLY GROMMET (8). Insert POWER CORD (10) into SPLIT PLUG (8a). Push SPLIT PLUG (8a) into POWER SUPPLY GROMMET (8) to seal. Fig. 10b.
6. Insert POWER SUPPLY CONNECTOR (9) into RECEPTOR (11) on CIRCUIT BOARD (3). Install CIRCUIT BOARD (3) into ELECTRICAL BOX (4).Fig. 10b.
7. Install the SENSOR WIRE GROMMET (15) into the COVER (2) as shown. Remove the SPLIT PLUG (15a) from SENSOR WIRE GROMMET (15). Insert SENSOR WIRE CONNECTOR (12) through SENSOR WIRE GROMMET (15). Insert SENSOR WIRE (13) into SPLIT PLUG (15a). Push SPLIT PLUG (15a) into SENSOR WIRE GROMMET (15) to seal. Fig. 10c.
8. Insert SENSOR WIRE CONNECTOR (12) into CIRCUIT BOARD RECEPTOR (14) slot. Fig. 10c.
9. Replace COVER (2). Tighten COVER SCREWS (1) firmly.
CONNECT FRONT PANEL TOELECTRICAL BOX (AC POWER);Fig. 10
7 Fig. 10
Fig. 10a
Fig. 10b
Fig. 10c
T O P
T O P
1
2
3
4
4
4
6 5
7
3
8
9
11
9
8
15
2
15a
1
12
13
8a10
KNOCK OUTBLANK
BLACK &RED WIRES
14
T O P
8
T O P
7
M968547 REV. 1.3
7
T O P
1. Remove the four COVER SCREWS (1) and COVER (2) from ELECTRICAL BOX (3). Fig. 10.
2. Install BATTERY (4) into holder on DC circuit board. Press BATTERY (4) down (contacts facing downward) into position until tabs lock BATTERY (4) into place.
3. Attach the SAFETY CHAIN (5) from the FRONT PANEL (6) to the MOUNTING POST (7) as shown.Feed the Red and Black wires through the back opening in the ELECTRICAL BOX (3). Fig. 11a.
4. Install the SENSOR WIRE GROMMET (11) into the COVER (2) as shown. Remove the SPLIT PLUG (11a) from SENSOR WIRE GROMMET (11). Insert SENSOR WIRE CONNECTOR (8) through SENSOR WIRE GROMMET (11). Insert SENSOR WIRE (9) into SPLIT PLUG (11a). Push SPLIT PLUG (11a) into SENSOR WIRE GROMMET (11) to seal. Fig. 11b.
8. Insert SENSOR WIRE CONNECTOR (8) into CIRCUIT BOARD RECEPTOR (10) slot. Fig. 11b.
9. Replace COVER (2). Tighten COVER SCREWS (1) firmly.
Fig. 11a
Fig. 11b
Fig. 12
1
2
3
4
6
11
211a
8
9
1
CONNECT FRONT PANEL TOELECTRICAL BOX (DC POWERBATTERY); Fig. 11
8 Fig. 11
1. Install the two TABS (1) on the back side of FRONT PANEL (2) into the two SLOTS (3) located on the top edge of the ELECTRICAL BOX (4). Fig. 12.
2. Push on the bottom edge of the FRONT PANEL (2) until it snaps into place. If FRONT PANEL (2) will not snap into place, then loosen the MOUNTING SCREWS (6) on the ELECTRICAL BOX (4) slightley.Fig. 12.
3. To remove FRONT PANEL (2) insert WIRE KEY (5) (supplied) into the two holes located at the bottom of the FRONT PANEL (2). Push the WIRE KEY (5) up until it releases the bottom clips. Pull the bottom edge away and lift the FRONT PANEL (2) off. Fig. 12.
INSTALL FRONT PANEL; Fig. 129
PUSH TOSNAP PANELINTO PLACE
5
6
2
T O P
5
7
BLACK &RED WIRES
T O P
1
23
4
T O P
3
10
M968547 REV. 1.3
8
1
4
2
5
5
6
BLUEHOSE
BLACKHOSE
1. Push the BLACK HOSE (1) into the BOTTOM HOSE CONNECTOR (2) and the other end into the back of the OVERRIDE SWITCH (3).
2. Push the BLUE HOSE (4) into the TOP HOSE CONNECTOR (5) on the valve and the other end into the BOTTOM CONNECTOR (6) on the OVERRIDE SWITCH (3).
CONNECT OVERRIDE HOSES,AC & DC POWER; Fig. 1310
1. Push the RED WIRE CONNECTOR (1) onto the SOLENOID PIN (2) with Red Stripe. Push the BLACK WIRE CONNECTOR (3) onto the other SOLENOID PIN (4). Push the wire connectors all the way down.
2. Code approved Electrical Outlet provided by others, (120V 50/60 Hz)..
3. Plug AC POWER SUPPLY (5) into Outlet.
CONNECT SOLENOID WIRINGAND POWER SUPPLY; Fig. 1411
Fig. 13
Fig. 14
3
REDWIRE
REDSTRIPE
BLACKWIRE
ELECTRICALOUTLET
1 3
2 4
M968547 REV. 1.3
9
FOR AC-VERSION(MULTI HOOK-UP); Fig. 15, 15a
Unit #1
Unit #1
Unit #2 Unit #3
1. Remove the COVER SCREWS (1) and COVER (2) from each ELECTRICAL BOX (3).
2. See AC Version Electrical Hook-up for Unit #1 of the Multi hook-up.
3. Install SENSOR WIRE GROMMET (4) and FLUSH VALVE SENSOR WIRE (5) into the COVER (2) of each unit. Insert the flush valve sensor wire connector into the CENTER CIRCUIT BOARD RECEPTOR (6) on each unit. Fig. 15a.
4. Remove the SPLIT PLUG (7a) from the SENSOR WIRE GROMMET (7) on the left side of each ELECTRICAL BOX (3).
5. Take the 10 ft. EXTENSION WIRE (8) from Unit #2 and insert one end of the EXTENSION WIRE CONNECTOR (9) through the SENSOR WIRE GROMMET (7) on left side of Unit #1. Insert EXTENSION WIRE (8) into SPLIT PLUG (7a). Push SPLIT PLUG (7a) into SENSOR WIRE GROMMET (7) to seal. Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10). Fig. 15a.
6. Insert other end of EXTENSION WIRE (8) into SENSOR WIRE GROMMET (7) on left side of Unit #2. Insert that EXTENSION WIRE CONNECTOR (9) into the LOWER CIRCUIT BOARD RECEPTOR (10) of Unit #2. Fig. 15b.
7. On Unit #2 ELECTRICAL BOX (3) remove ROUND KNOCK-OUT (11) on the bottom of the box by pressing a flathead screwdriver into the center of the ROUND KNOCK-OUT (11). Fig 15b.
8. Insert additional SENSOR WIRE GROMMET (12) included with Unit #2 into the knock-out opening in the bottom of the ELECTRICAL BOX (3). Take the 10 FT. EXTENSION WIRE (8) from Unit #3 and insert one end into the SENSOR WIRE GROMMET (12) in the bottom of the ELECTRICAL BOX (3) of Unit #2. Insert EXTENSION WIRE CONNECTOR (9a) into TOP CIRCUIT BOARD RECEPTOR (13) on Unit #2 . Fig. 15b.
9. Insert the other end of the EXTENSION WIRE (8) from Unit #3 into the SENSOR WIRE GROMMET (7) on the left side of Unit #3. Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10) on Unit #3.
10. Repeat Steps 7 to 9 as necessary for additional Multi-AC Units.
11. Once all wire connections are made. Install the COVER (2) and COVER SCREWS (1) onto each ELECTRICAL BOX (3).
Fig. 15
Fig. 15a
Fig. 15b
12
T O P T O P T O P
27a
7
8
3
6
1
54
9
T O P
10
SENSOR WIRECONNECTOR
SENSORWIRE
FROM UNIT #2
Unit #2
7a
78
3
9a
T O P
12
7
12
8
8 8 8
1211
109
SENSOR WIRECONNECTOR
FROMUNIT #3
BACK OF BOX (3)
FROM UNIT #1
REMOVE KNOCK-OUT (11),INSERT WIRE GROMMET (12)
1
2
SENSORWIRE
SENSORWIRE
610
7
610
13
7
610
13
13
M968547 REV. 1.3
10
Fig. 17
CLOCKWISE CLOSESCONTROL STOP
COUNTER-CLOCKWISEOPENS CONTROL STOP1
2
3
57
6
T O P
1. Remove FRONT PANEL. For removing front panel see Step 9 for instructions.
2. Remove the four COVER SCREWS (1) and COVER (2) from ELECTRICAL BOX (3). Fig. 16.
3. Disconnect GREY SENSOR WIRE (4) from CIRCUIT BOARD (5).
4. Remove CIRCUIT BOARD (5) from ELECTRICAL BOX (3). Fig. 16a. 5. With your thumbs, spread the two TABS (6) on battery holder apart and remove the BATTERY (7).
2. Install NEW BATTERY (7) into holder on DC circuit board. Press BATTERY (7) down (contacts facing downward) into position until TABS (6) lock BATTERY (7) into place.
6. Install CUIRCUIT BOARD (5) and connect GREY SENSOR WIRE (4). 7. Install COVER (2) and SCREWS (1).
8. Replace and FRONT PANEL. See Step 9 for instructions on installing front panel.
HOW TO INSTALL NEW BATTERY;Fig. 1613 Fig. 16
Fig. 16a
1
4
23
5
T O P
14IMPORTANT: To avoid overflowing, the SUPPLY STOP (2) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. The fixture must be able to handle a continuous flow in case of a flush valve failure.Valve is designed to provide stated flush volume with a 10 GPM flow rate.
1. After installation is complete, peel off the PROTECTIVE FILM (1) from the sensor. Standing to one side, block the sensor with your hand for 10 seconds. Remove your hand and listen for audible “click” from within the valve.
2. Turn on SUPPLY STOP (2) 1/4 turn to 1/2 turn(CCW) and test for leaks. Note: Unit may flush for approximately 5 to 10 sec. when water is first turned on. If flow persists, turn water off and repeat step #1 above.
3. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately 3 seconds.
4. Adjust SUPPLY STOP (2) after each flush until the stated flush volume is achieved, no splashing occurs and the fixture is properly cleansed.
ADJUST SUPPLY STOP; Fig. 17
M968547 REV. 1.3
11
Fig. 19 Fig. 19a
1" - 2" (30mm - 50mm)
BLINKING LED
6
MAXIMUMDETECTION ZONE400mm TO 800mm(15-3/4" TO 31-1/2")
BLINKING LED
6
T O P
Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below.
1. Remove FRONT PANEL (1). See Step 9 for removing front panel instructions.
2. Remove the four COVER SCREWS (2) and COVER (3) from ELECTRICAL BOX (4). Fig. 18.
3. Disconnect GREY SENSOR WIRE (5) from CIRCUIT BOARD. (6).
4. Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (5) and quickly hang the FRONT PANEL (1) onto the ELECTRICAL BOX (4). Do not secure the FRONT PANEL (1) at this time. Note: You have 5 seconds after connecting cable to begin program process.
5. While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 19.
6. When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and hold in place until the LED (6) begins to blink again. Fig. 19a.Note: Maximum Detection Zone is 15-3/4" to 31-1/2", (400 to 800mm ) from sensor. 7. Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.
8. Replace COVER (3). Tighten COVER SCREWS (2) firmly.
9. Replace the FRONT PANEL (1). See Step 9 for instructions on installing front panel.
10. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor, unit will flush in approximately 3 seconds.
HOW TO SET DETECTION RANGE(If Required) ; Fig. 18 & 1915 Fig. 18
1
2
5
34
5
M968547 REV. 1.3
12
IS S
TOP
VA
LVE
OP
EN
?
LOO
K F
OR
RE
PE
ATE
DD
OU
BLE
FLA
SH
ON
SE
NS
OR
YE
SIN
STA
LL N
EW
BA
TTE
RY
TRY
MA
NU
AL
VALV
E B
UTT
ON
;W
ILL
THE
UN
IT F
LUS
H?
NO
RE
PLA
CE
PIS
TON
KIT
INS
TALL
NE
W B
ATT
ER
Y o
r P
LUG
-INA
C P
OW
ER
SU
PP
LYSE
E ST
EP 1
3, p
age
10 in
man
ual
NO
RE
PLA
CE
SE
NS
OR
NO
YE
S
NO
NO
YE
S
YE
S
OP
EN
VA
LVE
UN
IT W
ILL
ON
LY F
LUS
H M
AN
UA
LLY
LOO
K F
OR
RE
PE
ATE
DD
OU
BLE
FLA
SH
ON
SE
NS
OR
RE
TRY
AU
TOM
ATI
C F
LUS
H.
DO
ES
TH
E U
NIT
FLU
SH
?
RE
TRY
AU
TOM
ATI
C F
LUS
H.
TES
T S
EN
SO
R. D
ISC
ON
NE
CT
GR
AY F
LAT
WIR
E F
RO
M C
IRC
UIT
BO
AR
D A
ND
RE
-CO
NN
EC
T. S
EN
SO
RS
HO
ULD
FLA
SH
FO
R 5
SE
CO
ND
S.
DO
ES
IT F
LAS
H?
TES
T S
EN
SO
R. D
ISC
ON
NE
CT
GR
AY F
LAT
WIR
E F
RO
MC
IRC
UIT
BO
AR
D A
ND
RE
-CO
NN
EC
T.S
EN
SO
R S
HO
ULD
FLA
SH
FO
R 5
SE
CO
ND
S. D
OE
S IT
FLA
SH
?
CLO
SE
STO
P V
ALV
E,
RE
PLA
CE
SO
LEN
OID
KIT
.R
E-A
SS
EM
BLE
& IN
STA
LL U
NIT
.O
PE
N S
TOP
VA
LVE
.
BA
TTE
RY
LO
W;
RE
PLA
CE
BA
TTE
RY
SEE
STEP
13,
pag
e 10
in m
anua
l
NO
NO
YE
S
DO
ES
TH
E S
EN
SO
R F
LAS
HFO
R T
HE
FIR
ST
5 S
EC
ON
DS
?
NO
RE
PLA
CE
SO
LEN
OID
KIT
RE
TRY
AU
TOM
ATI
C F
LUS
H;
WA
S IT
SU
CC
ES
SFU
L?
YE
S
1. C
OV
ER
SE
NS
OR
FO
R 1
0 S
EC
ON
DS
2. U
NC
OV
ER
SE
NS
OR
FO
R 1
0 S
EC
ON
DS
.
RE
PLA
CE
BA
TTE
RY
SEE
STEP
13,
pag
e 10
in m
anua
l
MA
NU
AL
VALV
EO
BS
TRU
CTE
D.
CLO
SE
STO
P V
ALV
EA
ND
SE
RV
ICE
RE
TRY
AU
TO F
LUS
H
NO
UN
IT IS
CO
NTI
NU
OU
SLY
FLU
SH
ING
PU
SH
MA
NU
AL
FLU
SH
BU
TTO
N; D
OE
S IT
RE
TUR
N?
LOO
K F
OR
RE
PE
ATE
DD
OU
BLE
FLA
SH
ON
SE
NS
OR
NO
NO
YE
S
NO
1. C
OV
ER
SE
NS
OR
FO
R 1
0 S
EC
ON
DS
2. U
NC
OV
ER
SE
NS
OR
FO
R 1
0 S
EC
ON
DS
.
DO
ES
TH
E U
NIT
STO
P F
LUS
HIN
G?
YE
S
INS
TALL
NE
W B
ATT
ER
YSE
E ST
EP 1
3, p
age
10in
man
ual
YE
S
1. C
LOS
E S
TOP
VA
LVE
,2.
RE
PLA
CE
SO
LEN
OID
KIT
.3.
RE
-AS
SE
MB
LE A
ND
INS
TALL
UN
IT.
4. O
PE
N S
TOP
VA
LVE
.
RE
PLA
CE
SE
NS
OR
NO
TROU
BLES
HOOT
ING FL
OW CH
ARTS
UN
IT D
OE
S N
OT
FLU
SH
AT
ALL
HOT
LIN
E FO
R H
ELP
For
toll-fr
ee in
form
atio
n an
d an
swer
s to
you
r qu
estio
ns,
call:
1 (8
00
) 4
42
-19
02
Wee
kday
s 8
:00
a.m
. to
6:0
0 p
.m.
EST
IN C
AN
AD
A
1-8
00
-38
7-0
36
9
(TO
RON
TO 1
-90
5-3
06
-10
93
)W
eekd
ays
8:0
0 a
.m.
to 7
:00
p.m
. ES
T
Pro
duct
nam
es
liste
d h
ere
in a
re t
radem
ark
s of
AS
Am
eri
ca,
Inc.
IN M
EXIC
O
01
-80
0-8
39
-12
-00
M968547 REV. 1.3