Selection & use of THERMOSTATIC BLENDER VALVES Xylem Water Solutions UK Ltd Bingley Road • Hoddesdon • Hertfordshire • EN11 0BU • UK Telephone: +44 (0)1462 480380 Fax: +44 (0)1462 482422 [email protected] www.jabscoshop.com DOC581/11 For automatic temperature control of hot water supply Step-less adjustment for smooth, continuous temperature control. Prevents scalding risk from water stored above 65ºC to kill Legionella Fail-safe: hot water outlet closes if cold water supply fails Increases effective volume of stored hot water Suitable for use with Hep 2 O push-fit pipework CW268ø15mm short pipe runs CW268 15mm CW272B 22mm CW272Bø22 main delivery pipes, ø15mm branches to individual outlets

Selection & use of THERMOSTATIC BLENDER VALVES and CW272... · the system before fitting the valve. 3. Minimum 10oC temperature difference between hot and cold water supply 4. Do

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Selection & use of THERMOSTATIC BLENDER VALVES and CW272... · the system before fitting the valve. 3. Minimum 10oC temperature difference between hot and cold water supply 4. Do

Selection & use of THERMOSTATIC BLENDER VALVES

Xylem Water Solutions UK Ltd Bingley Road • Hoddesdon • Hertfordshire • EN11 0BU • UK Telephone: +44 (0)1462 480380 Fax: +44 (0)1462 482422 [email protected] www.jabscoshop.com

DOC581/11

For automatic temperature control of hot water supply

Step-less adjustment for smooth, continuous temperature control.

Prevents scalding risk from water stored above 65ºC to kill Legionella

Fail-safe: hot water outlet closes if cold water supply fails

Increases effective volume of stored hot water

Suitable for use with Hep2O push-fit pipework

CW268… ø15mm short pipe runs

CW268 15mm

CW272B 22mm

CW272B…ø22 main delivery pipes, ø15mm branches to individual outlets

Page 2: Selection & use of THERMOSTATIC BLENDER VALVES and CW272... · the system before fitting the valve. 3. Minimum 10oC temperature difference between hot and cold water supply 4. Do

CW268 & CW272B Installation instructions:

Fit the valve as shown on front sheet.

1. The valve may be installed in any orientation

2. Check that your pressurised water system has a strainer in the cold water supply line. Flush the system before fitting the valve.

3. Minimum 10oC temperature difference between hot and cold water supply

4. Do not use jointing compounds on the connections

Commissioning the valve

1. Start the pressure system and heat the water.

2. Open a hot water tap and check the temperature of the water. If the temperature needs to be adjusted:

on CW268 (15mm) simply turn the adjustment knob

on CW272B (22mm) -

1. remove the central screw and the plastic knob

2. loosen the large lock-nut

3. using a 6mm A/F spanner, turn the square nut clockwise to decrease temperature, anti clockwise to increase temperature

Xylem Water Solutions UK Ltd Bingley Road • Hoddesdon • Hertfordshire • EN11 0BU • UK Telephone: +44 (0)1462 480380 Fax: +44 (0)1462 482422 [email protected] www.jabscoshop.com

DOC581/11

LARGE BOATS and SYSTEMS with a secondary recirculation loop, ø15mm pipes to individual outlets

CW272B adjustment