Selecting A FoamPro SystemSelecting A FoamPro System
2
• Class A foam concentrates– NFPA 1150 or US Forest Service Approved
• Class B foam concentrates– Use of a lower % foam concentrate will increase the
discharge capabilities; i.e., 1%x3% versus 3%x6%.– AFFF – AR-AFFF (Viscosity considerations) – Control at each discharge
• Emulsifiers– Viscosity considerations
What Type(s) Of Foam Concentrate What Type(s) Of Foam Concentrate Do You Want To Proportion?Do You Want To Proportion?
3
What Are Water/Foam Flow What Are Water/Foam Flow Requirements?Requirements?
• What discharges require foam solution?– Pre-connected hand lines, trash lines, etc.
– 2-1/2” and/or larger discharge(s)
– Deck gun or aerial waterway (secondary feed)
• What are min. & max. GPM requirements of
solution?
• What are min. & max concentrate levels?
• Properly size proportioner, main waterway
check valve and flowmeter
4
Class B Foam Sizing ConsiderationsClass B Foam Sizing Considerations
• Performance expectations• NFPA standards• Storage requirements
(On and off vehicle)
• Logistical requirements• Concentrate proportioning rates• Control at each discharge
(AccuMax single or multi-point injection)
5
Gallons per minute of foam concentrate required
Injection Gallons per Minute WaterRate 25 50 100 200 300 400 500 10000.1% 0.025 0.05 0.1 0.2 0.3 0.4 0.5 1.00.5% 0.125 0.25 0.5 1.0 1.5 2.0 2.5 5.01.0% 0.25 0.5 1.0 2.0 3.0 4.0 5.0 10.03.0% 0.75 1.5 3.0 6.0 9.0 12.0 15.0 30.06.0% 1.5 3.0 6.0 12.0 18.0 24.0 30.0 60.0
Rate 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,0001.0% 15 20 25 30 35 40 45 503.0% 45 60 75 90 105 120 135 1506.0% 90 120 150 180 210 240 270 300
Sizing The Proportioner Sizing The Proportioner
6
Class A ExampleClass A Example
• Flow requirements – Maximum: One deck gun 500 gpm– Minimum: One 1-1/2” 35 gpm (mop up)
• Concentrate level requirements– Maximum 1.0% (exposure protection)– Minimum 0.3% (initial attack)
• Calculate concentrate requirements– Maximum: 500 gpm x 1.0% = 5 gpm– Minimum: 35 gpm x 0.3% = .105 gpm
• Choose pump and flowmeter from charts
7
Fuel Hydrocarbon Polar Solvents
Foam Type AFFF or FFFP AR/AFFF
Application .10 gpm/ft2 @ 1% .10 to .20 gpm/ft2 @ 3%Rate Formula or 3% or 6%
Spill Area 50 x 50 = 2500 sq.ft.
Critical 2500 2500Application Rate x .10 gpm/ft2 x .17gpm/ft2 250 gpm 425 gpm
Total Foam 250 gpm 425 gpm Concentrate x 15 min x .01 = 37.5 x 15 min x .03 =
191on Scene or x .03 = 112 or x .06 =
382
Class B Foam Application RatesClass B Foam Application RatesNFPA 11 or Manufacturers RateNFPA 11 or Manufacturers Rate
8
The FoamPro Product LineThe FoamPro Product Line
Model Capacity (Class A foam only)
1600 0.1-1.7 gpm
1601 0.1-1.1 gpm (Class A and/or B foam)
2001 0.01-2.6 gpm
2002 0.01-5.0 gpm
3012 0.1-12.0 gpm
Maximum operating pressure
400 psi
Model Capacity
3020 4.0 - 20.0 gpm
3040 4.0 - 40.0 gpm
3060 4.0 - 60.0 gpm
3090 6.0 - 90.0 gpm
3150 6.0-150.0 gpm
3300 10.0-300.0 gpm
Dual pump option available for flows below 3000 series minimums
Maximum operating pressure 250 psi
Product LineupProduct LineupClass A Single Point InjectionClass A Single Point Injection
10
FoamPro 1600 SeriesFoamPro 1600 Series
• Ideal applications: – Brush rigs/skid units– Fast attack vehicles– Municipal apparatus– Retrofits– Compressed Air Foam
Systems
• Treats up to:– 340 gpm @ 0.5%– 170 gpm @ 1.0%
Product LineupProduct LineupClass A And/Or B Class A And/Or B
Single Point InjectionSingle Point Injection
12
FoamPro 2000 SeriesFoamPro 2000 Series
• Ideal applications:– Municipal pumpers– Wildland pumpers– Marine and shipboard– Dual foam systems – Compressed Air Foam
Systems
• Treats up to:– 1000 gpm @ 0.5%– 500 gpm @ 1.0%
13
Capabilities Of A 5.0 GPM SystemCapabilities Of A 5.0 GPM System
Class A Attack Capability % Solution Attack Capability0.2% 2,000 GPM 200,000 cu. ft.0.5% 1,000 GPM 100,000 cu. ft.1.0% 500 GPM 50,000 cu. ft.
Solution flow and critical application rate using the Iowa formula
14
Capabilities Of A 5.0 GPM SystemCapabilities Of A 5.0 GPM System
Class B Attack Capability % Solution Attack Capability1% 500 GPM 4,980 sq. ft.3% 166 GPM 1,660 sq. ft.6% 87 GPM 830 sq. ft.
Solution flow and critical application rate on Hydrocarbon @ 0.10gpm / sq ft
15
FoamPro Model 3012FoamPro Model 3012
• Ideal applications:– Municipal pumpers– Wildland pumpers– Marine and shipboard– Dual foam systems– Compressed Air Foam
Systems
• Treats up to:– 2400 gpm @ 0.5%– 1200 gpm @ 1.0%
16
Capabilities Of A 12.0 GPM SystemCapabilities Of A 12.0 GPM System
Class A Attack Capability % Solution Attack Capability0.2% 6,000 GPM 600,000 cu. ft.0.5% 2,400 GPM 240,000 cu. ft.1.0% 1,200 GPM 120,000 cu. ft.
Solution flow and critical application rate using the Iowa formula
17
Capabilities Of A 12.0 GPM SystemCapabilities Of A 12.0 GPM System
Class B Attack Capability
% Solution Attack Capability1.0% 1,200 GPM 12,000 sq. ft.
3.0% 400 GPM 4,000 sq. ft.
6.0% 200 GPM 2,000 sq. ft.Solution flow and critical application rate on Hydrocarbon @
0.10 gpm / sq ft
AccuMax AccuMax High Flow Industrial Systems High Flow Industrial Systems
19
AccuMax Single Point SystemsAccuMax Single Point Systems
• Ideal applications:– Industrial – Municipal pumpers – Airport rescue – Aerial apparatus– Compressed Air Foam
Systems
• Treats up to:– 10,000 gpm @ 3.0%– 5,000 gpm @ 6.0%
20
WaterTank
Check Valves
WaterPump
MultipleDischarges
Flowmeter
FoamTank
Line Strainer
Digital Display Control
AccuMax Single Point InjectionAccuMax Single Point Injection
21
Size Max Accuracy Max OperatingTee Flow Range Flow Range1-1/2x1" 5 - 110 gpm 3 - 145 gpm
1-1/2" 10 - 320 gpm 3 - 380 gpm
2" 15 - 520 gpm 5 - 625 gpm
2-1/2" 20 - 750 gpm 8 - 900 gpm
3" 30 - 1150 gpm 12 -1380 gpm
4" 55 - 1980 gpm 20 - 2380 gpm6" ** 70 - 2800 gpm 30 - 3300 gpm8" ** 120 - 4800 gpm 50 - 5600 gpm
** Electromagnetic flowmeter
Determine Flowmeter RequirementsDetermine Flowmeter Requirements
22
AccuMax Multi-Point SystemsAccuMax Multi-Point Systems
• Microprocessor Control– On-demand multi-point foam
injection at each discharge– Unmatched accuracy across full
performance range
• Edwards Rotary Gear Pumps– 40, 60, 90, 120, 150 & 300 GPM
Models– All bronze construction
• Use Multiple Foam Sources– Foam tank or outboard pickup
23
• Superior Performance– No flow restrictions– Not affected by external
factors
• Calibration And Testing– Easy, fast, reuse the foam
• Applications Include:– Industrial Apparatus,
Marine
AccuMax Multi-Point SystemsAccuMax Multi-Point Systems
24
• Master Control– Provides total system
control and performance information
– Advanced self-diagnostics• Individual Line Control
– Each allows plain water or choice of injection percentage
– Displays line performance along with water & foam totals
• Digital Displays– Simple push button control– Ultra-bright LED readout
AccuMax Multi-Point Systems AccuMax Multi-Point Systems OperationsOperations
25
AccuMax Multi-Point Line ControllerAccuMax Multi-Point Line Controller& Flowmeter Sizing& Flowmeter Sizing
Discharge Injection Foam Flowmeter Size Line Size Capacity Range 1% 3% 6%
1-1/2" 1/2" 3 - 26 3-380 300-380 100-380 50-380
1-1/2" 1/2" EXT 1-26 3-380 100-380 33-380 17-380
1-1/2" 3/4" 6 - 60 3-380 N/A 200-380 100-380
2" 3/4" 6 - 60 5-625 600-625 200-625 100-625
2-1/2" 3/4" 6 - 60 8-900 600-900 200-900 100-900
1-1/2" 1" EXT 1.8-60 3-380 180-380 60-380 30-380
2" 1" EXT 1.8-60 5-625 180-625 60-625 30-625
2-1/2" 1" EXT 1.8-60 8-900 180-900 60-900 30-900
based on water flowmeter range and foam capacityWater Treatable Water Flow
26
AccuMax Multi-Point Line ControllerAccuMax Multi-Point Line Controller& Flowmeter Sizing& Flowmeter Sizing
Discharge Injection Foam Flowmeter Size Line Size Capacity Range 1% 3% 6%
3" 1-1/4" 10-100 12-1380 1000-1380 333-1380 167-1380
4" 1-1/4" 10-100 20-2380 1000-2380 333-2380 167-1667
4" 1-1/2" 16-150 135-2800 1600-2380 533-2380 267-1667
6" 1-1/2" 16-150 135-2800 1600-2800 533-2800 267-2500
8" 1-1/2" 16-150 235-5000 1600-5000 533-5000 267-2500
10" 1-1/2" 16-150 375-8100 1600-8100 533-5000 375-2500
4" 2" 24-300 20-2380 N/A 800-2380 400-2380
6" 2" 24-300 135-2800 2400-2800 800-2800 400-2800
8" 2" 24-300 235-5000 2400-5000 800-5000 400-5000
10" 2" 24-300 375-8100 2400-8100 800-8100 400-8100
based on water flowmeter range and foam capacity
Water Treatable Water Flow
27
Plumbing SuggestionsPlumbing Suggestions
• 1-1/2" or 2" Flowmeter tee– One or two preconnects and booster lines
• 2-1/2" or 3" Flowmeter tee– Two to three preconnects, 2-1/2" discharge and
supplemental feed to deck gun
• 4" Flowmeter tee– Large waterway flow i.e. preconnects, multiple 2-1/2"
discharges, deck guns and/or aerial waterway
28
FoamPro OptionsFoamPro Options
• Manual Concentrate Management System *– Controls Tank A and Tank B with manual flush
• Electronic Concentrate Management system *– Controls Tank A and Tank B with automatic flush
• MultiFlo Interface *– Digital display of individual water flows, up to 4 discharges
• Dual Injection Selector *– Allows for two separate injection points
• Advanced Feature Controller *– Offers “Auto-On” Programming
*Not Available on 1600 Series or AccuMax Multi-Point Systems
29
FoamPro OptionsFoamPro Options (cont.)(cont.)
• Poly Foam Tanks– 5, 12 and 20 gallon
• Main Waterway Check Valves– 1-1/2", 2", 2-1/2", 3", and 4" NPT, BSP, and Victalulic
• Stainless Steel Manifold– 1-1/2", 2", 2-1/2", 3", and 4" Victaulic
• Solid State Contactor– Offers higher surge protection than solenoids
• Remote Start/Stop Switch– Allows driver to activate for pump and roll operations
• System Placards– Schematic and rating
30
AccuMax Multi-Point OptionsAccuMax Multi-Point Options
• Low Flow• Manual Override• Pressure Readout at Each Discharge• High Pressure Injection (300 PSI)
• Hydraulic Pump Configurations
Product LineupProduct LineupRefill SystemsRefill Systems
32
Power-FillPower-Fill
• Improved Safety– No injuries from climbing
on top of vehicles or lifting foam containers
• Increased Efficiency– Accomplish task faster with
fewer personnel
• Added Economy– Purchase concentrate in
larger containers for less cost
• Two Models– Greater flexibility
33
D.C. ModelD.C. Model
• On-Board System– Pre-plumbed for fast, easy
operation
• Easy To Use– Microprocessor control– Push button activation– Automatic shut-off– Manual override
• Heavy Duty Pump– Up to 12 GPM– 12 volt ½ hp motor
– 24 volt available– Excellent drafting– Handles all viscosities
34
A.C. ModelA.C. Model
• Portable System– Easily moved to apparatus– Pre-plumbed piping
• Simple Operation– Full tank indicator– Momentary switch
• Heavy Duty Pump– Up to 18 GPM– 110 volt ½ hp motor– Excellent drafting– GFI protected– Handles all viscosities
35
Some Friendly AdviceSome Friendly Advice
• Define your needs– Immediate– Life of the vehicle
• Thoroughly check out all of the systems being considered– What the system will and will not do– Check with those who have experience – Consult with more than one reliable source
36
A “Solution” For A “Solution” For Every ApplicationEvery Application