4
Plug-In Recloser Control Compatibility The SEL-351R Falcon Recloser Control is a plug-compatible replacement for Cooper Kyle ® Form 3, 3A, 4, 4A, 4C, FXA, FXB, 5, and 6 recloser controls, and is compatible with popular reclosers from Cooper, G&W, Joslyn, and FKI Whipp & Bourne. Familiar “EZ” recloser control settings speed commissioning, and the SEL-351R Falcon is independently certified to IEEE C37.60-2003 recloser standards. Lightweight and Rugged One person can easily lift and quickly install this lightweight recloser control. The durable, gasketless, painted aluminum enclosure will not rust, is rugged enough for line installation, and carries a NEMA 3R rating to ensure reliable performance in all weather conditions. A swing-open NEMA 3R enclosure with a gasketed door is also available. Interface That Matches Your SEL Substation Relays There is no need to learn a new HMI; install the SEL-351R Falcon, and keep the look and feel of the front panel you already use in your substation relays. Advanced Battery-Charging and -Monitoring System The 120 Vac/Vdc powered battery-charging system monitors and tests the 24 Vdc battery and includes automatic sleep and local wake-up functions. Making Electric Power Safer, More Reliable, and More Economical ® Take Control of Your Recloser SEL-351R Falcon Recloser Control Features and Benefits SEL-351S SEL-351S SEL-351S

SEL-351R Falcon™

  • Upload
    dinhnhi

  • View
    218

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SEL-351R Falcon™

O:\MarComm\FLYERS\~Flyer_FIX\351R_Falcon_Flyer

Plug-In Recloser Control Compatibility The SEL-351R Falcon Recloser Control is a plug-compatible replacement for Cooper Kyle® Form 3, 3A, 4, 4A, 4C, FXA, FXB, 5, and 6 recloser controls, and is compatible with popular reclosers from Cooper, G&W, Joslyn, and FKI Whipp & Bourne. Familiar “EZ” recloser control settings speed commissioning, and the SEL-351R Falcon is independently certified to IEEE C37.60-2003 recloser standards.

Lightweight and RuggedOne person can easily lift and quickly install this lightweight recloser control. The durable, gasketless, painted aluminum enclosure will not rust, is rugged enough for line installation, and carries a NEMA 3R rating to ensure reliable performance in all weather conditions. A swing-open NEMA 3R enclosure with a gasketed door is also available.

Interface That Matches Your SEL Substation RelaysThere is no need to learn a new HMI; install the SEL-351R Falcon, and keep the look and feel of the front panel you already use in your substation relays.

Advanced Battery-Charging and -Monitoring SystemThe 120 Vac/Vdc powered battery-charging system monitors and tests the 24 Vdc battery and includes automatic sleep and local wake-up functions.

Making Electric Power Safer, More Reliable, and More Economical ®

Take Control of Your Recloser

SEL-351R Falcon™ Recloser Control

Features and Benefits

Making Electric Power Safer, More Reliable, and More EconomicaMaking Electric Power Safer, More Reliable, and More Economica

SEL-351S

SEL-351S

SEL-351S

Page 2: SEL-351R Falcon™

O:\MarComm\FLYERS\~Flyer_FIX\351R_Falcon_Flyer

Save Time and Simplify Settings• Save engineering time while keeping flexibility. Communicate

with the SEL-351R Falcon through any ASCII terminal, or use the acSELErator QuickSet graphical user interface.

• Develop settings offline with a menu-driven interface and completely documented help screens. Speed installation by copying existing settings files and modifying application-specific items.

Analyze Fault Records and Relay Element Response With acSELErator QuickSet

• Convert relay event reports to oscillography with time-coordinated element assertion and phasor display.

• Quickly analyze fault records and relay element response using the acSELErator

® Waveform Viewer.

Build and Edit QuickSet Design Templates With acSELErator QuickSet Designer®

• Create custom views of settings, called QuickSet Design Templates. This makes installation of a new device simple and helps ensure that new devices are applied according to your organization’s standards.

• Import and use QuickSet Design Templates with acSELErator QuickSet Software. Each device requires a reduced set of user entries because the standardized, unused, and application-specific settings are hidden by the template.

View system data and streamline relay settings with acSELErator QuickSet® Software.

Functional Overview

Compatible With acSELErator QuickSet® SEL-5030 Software

*Optional Functions

79

25

81 OU59

PGQ

27

27 59

67PGQ

50PGQ

51PGQ

67N 50N 51N

SEL-351R Falcon™ Recloser Control

1

3

Line

Bus

Time-Overcurrent • Phase • Ground • Neg. Seq.

Overcurrent • Phase • Ground • Neg. Seq.

DirectionalOvercurrent • Phase • Ground • Neg. Seq.

NeutralOvercurrent

Neutral Time-Overcurrent

DirectionalNeutral

Overcurrent SynchronismCheck

Autoreclosing

Undervoltage Overvoltage

Undervoltage Overvoltage • Phase • Ground • Neg. Seq.

Over-/Under-frequency

Resi

dual

DFR

Event Reports

SER

SequentialEvents Recorder

MET

High-AccuracyMetering

HMI

OperatorInterface

LGC

SELOGIC®

Fault Locator

BRM

Breaker WearMonitor

SEL MIRRORED BITS®

3 1

85RIOLOC

EIA-232EIA-485*

Recloser

IRIG-B

Load DataProfiling

LDP

Page 3: SEL-351R Falcon™

O:\MarComm\FLYERS\~Flyer_FIX\351R_Falcon_Flyer

Upgrade Existing Recloser Controls

• Compatible with Cooper control cables.

• “EZ” settings are similar to traditional recloser controls and compatible with acSELErator QuickSet.

• Event reports with waveform data.

Connect Three-Phase Voltage• Power and energy metering.

• Directional overcurrent protection.

Lightweight and Rugged Enclosure

• Lightweight; easy for one person to lift.

• Painted aluminum enclosure will not rust or corrode.

• Low-profile design mounts quickly on natural and fabricated poles.

• Gasketless enclosure is NEMA 3R rated.

• Optional swing-open enclosure with gasketed door and NEMA 3R rating.

Retrofit Traditional Installations Recloser Compatibility Chart

Manufacturer Recloser

SEL-351R Falcon Compatible

CooperCXE 3NOVA™ Auxiliary Powered 3RE 3RVE 3RXE 3VSA 3VSO 3VWE 3VWVE 27 3VWVE 38X 3WE 3WVE 27 3WVE 38X 3

G&WViper®-G 3Viper®-S 3

JoslynTriMod™ 300R 3

FKI Whipp & BourneGVR* 3

Other reclosers can be added on request.

*When equipped with interface module.

Recloser AccessoriesSEL offers best-in-class accessories to optimize the efficiency and utilization of your recloser controls. Many accessories can either be factory installed or supplied as a field upgrade kit.

SEL-2401 Satellite-Synchronized ClockRelay Event Correlation

Reduce system event analysis time by having perfectly aligned events from both distribution and substation devices. SCADA-based distributed time commonly provides accuracy to ±0.5 seconds. As a result, events between multiple devices cannot be compared. The SEL-2401 achieves ±100 nanosecond time accuracy.

SEL-2925 BLUETOOTH® Serial AdapterApply Easily With Low Impact and Cost

Install on the serial port of the Falcon to communicate with your BLUETOOTH-equipped laptop, tablet, or smartphone from up to 328 feet away.

Enter an 8- to 20-character encryption PIN to enable communication. The SEL-2925 is always secure, using BLUETOOTH v2.1 + EDR security.

Protect Personnel and EquipmentAvoid exposing personnel to hazardous conditions by controlling and monitoring the SEL-351R Falcon from a truck or other safe location. Keep enclosure and control house doors shut to protect equipment from weather and contaminants.

SEL Fault IndicatorsFind Faults Faster

SEL fault indicators reduce fault-finding time by as much as 50 percent, helping to restore power more quickly and efficiently. They also help reduce costly damage to the power system caused by faults and fault finding by eliminating the need to use multiple fuses for the re-fuse and sectionalize method of fault locating.

Recloser Controls and Fault Indicators Work Together

When SEL fault indicators are combined with recloser controls, they can pinpoint the exact location of a fault even on lateral feeds, something neither product can do on its own. When a fault occurs, the SEL recloser control reports the distance from the recloser to the fault; however, for lines with branches, the recloser control cannot determine on which branch of the line the fault has occurred. By following the line along the tripped fault indicators, the line crew can easily find the area of the fault.

Untripped Fault Indicator

Tripped Fault Indicator

Possible Fault Location

Page 4: SEL-351R Falcon™

O:\MarComm\FLYERS\~Flyer_FIX\351R_Falcon_Flyer

Ground Enabled—Turn ground overcurrent protection on/off.

Reclose Enabled—Turn autoreclosing on/off.

Remote Enabled—Turn remote control of SEL-351R on/off.

Alternate Settings—Switch between normal and alternate settings.

Lock—Block operation of selected operator controls.

Aux 1/Aux 2—Program the way you want (e.g., turn fast curve tripping on/off).

Wake Up—Wake up SEL-351R during extended power outage.

Close/Recloser Closed—Manually close recloser/status with optional time delay.

Trip/Recloser Open—Manually trip recloser/status with optional time delay.

For detailed specifications, refer to the SEL-351R Falcon data sheet or instruction manual available on www.selinc.com.

Simplify Panel-Mounted MeteringReduce the installed cost of feeder control panels by avoiding separately mounted metering devices. SEL-351R metered quantities include phase voltages and currents (including demand), sequence voltages and currents, power, frequency, and energy along with maximum/minimum logging of selected quantities.

Switch Sources—Keep Load in Service During Outage• Choose SEL MirrorEd BitS

® communications to securely share recloser status, source status, and other logic information between SEL-351R Falcon Recloser Controls.

• Apply voltage synchronism check on closing.

Other Communications Capabilities • DNP3 Level 2 Outstation communications protocol.

• 12 Vdc auxiliary power available for modem or radio.

Source #1

Source #2

Hospital(critical load)

Communicate directly to any SEL-351R Falcon™ Recloser Control using radio, fiber-optic, serial, or telephone communications without the need for a field RTU.

3

1

1

3

Fiber-optic or radiocommunications optional

MIRRORED BITS®

communications fiber linkup to 16 km using SEL-2815

Recloser

Recloser

Contact your SEL representative for complete packaged solutions.

Control pushbuttons are set at the factory with these default actions. These pushbuttons can be field-programmed with configurable labels to fit your application.

SEL-351R Falcon Recloser Control

Automate Your Distribution System

High-Accuracy Metering

General Specifications

Control With Front-Panel Pushbuttons

Pullman, Washington USATel: +1.509.332.1890 • Fax: +1.509.332.7990 • www.selinc.com • [email protected]

© 2008—2012 by Schweitzer Engineering Laboratories, Inc. PF00187 • 20120628

The BLUETOOTH word mark and logos are registered trademarks owned by Bluetooth SIG, Inc., and any use of such marks by SEL is under license.