2
C146-E119B LCMS-2020 Liquid Chromatograph Mass Spectrometer UFscanning UFswitching UFsensitivity 15,000 u/sec high-speed scanning 15 milliseconds high-speed polarity ionization switching time High-speed analysis with high sensitivity Seeing is Believing.

Seeing is Believing. - SHIMADZUSeeing is Believing. Printed in Japan 3295-11103-30ANS Company names, product/service names and logos used in this publication are trademarks and trade

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Seeing is Believing. - SHIMADZUSeeing is Believing. Printed in Japan 3295-11103-30ANS Company names, product/service names and logos used in this publication are trademarks and trade

C146-E119B

LCMS-2020Liquid Chromatograph Mass Spectrometer

UFscanning

UFswitching

UFsens i t iv i ty

15,000 u/sec high-speed scanning

15 milliseconds high-speed polarity ionization switching time

High-speed analysis with high sensitivity

Seeing is Believing.

Page 2: Seeing is Believing. - SHIMADZUSeeing is Believing. Printed in Japan 3295-11103-30ANS Company names, product/service names and logos used in this publication are trademarks and trade

Printed in Japan 3295-11103-30ANS

Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation and its affiliates, whether or not they are used with trademark symbol “TM” or “®”.Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.

For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.

© Shimadzu Corporation, 2012www.shimadzu.com/an/

UFscanning & UFswitching

UFscanning and UFswitching are critical for ultra-fast analysis.

UFsensitivity

UFLC/MS Measurement

Newly developed ion optical system and new Qarray® optics provide excellent sensitivity, repeatability and linearity, even in ultra-fast analysis.

Ultra-fast analysis with excellent sensitivity

Hardware features that powerfully support 3 types of UF functionality

In order to check toughness of LCMS-2020 against dirty samples, plasma samples simply precipitated with only acetonitrile were injected 2,500 times over 10 days (1L volume per injection). Excellence reproducibility of peak area was demonstrated and its RSD was 2.26%.

Toughness against dirty samples The DL capillary (desolvation line), which transfers the sample into the vacuum chamber from the ion source, can be installed and removed without breaking the vacuum, greatly speeding maintenance operations.

Easy Maintenance

In ultra-fast analysis where multicomponent may elute within 1 minute, ultra-fast (MS measurement) detection is also required. The UFswitching and UFscanning functions are what make possible such ultra-fast MS measurement.

15 milliseconds polarity switching

Positive ion measurement15,000 u/sec

Positive ion measurement15,000 u/sec

Negative ion measurement15,000 u/sec

15 milliseconds polarity switching

Calibration curve