SEE 3433 Elements of Armature Winding in DC Machines

SEE 3433 Elements of Armature Winding in DC Machines

Embed Size (px)

Citation preview

Page 1: SEE 3433 Elements of Armature Winding in DC Machines

SEE 3433Elements of Armature Winding in

DC Machines

Page 2: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

A turn – two conductors connected to an end by an end connector

Page 3: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

A coil – several turns connected in series

Page 4: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

A winding – several coils connected in series

Page 5: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

The angle between centers of adjacent poles is 180o (electrical)

N

N

S S

360o electrical = 180o mech

180o electrical = 90o mech

Page 6: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

The angle between centers of adjacent poles is 180o (electrical)

N

N

S S

If coil sides are placed 180o electrical apart, the coil is said to be full-pitch

a

b

180oelec

a b

Page 7: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

The most common ways of connecting coils for armature windings:

Lap windingWave winding

Ends of the coils are connected to the commutator bars

In DC machines most of the coils are full-pitch.

Page 8: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

Commutator bar

Lap winding

• One coil between adjacent commutator bars• 1/p of total coils are connected in series• No. of poles no. of brushes no. of parallel paths

Page 9: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

Page 10: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings

Wave winding

• p/2 coils in series between adjacent commutator bars• ½ of all coils between brushes• Regardless of no. of poles, there are always 2 parallel path• The distance between end coils (commutator pitch) is 2(C1)/p

where C is the no. of commutator bars

Page 11: SEE 3433 Elements of Armature Winding in DC Machines

Elements of an armature windings