10

Section: P. PLENARY SESSION

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Section: P. PLENARY SESSION
Page 2: Section: P. PLENARY SESSION

Section: P. PLENARY SESSIONP.1. Mid-Term Framework Programme of the Bulgarian Institute of Metrology in Supportof Innovations and CompetitivenessP.2. The Metrological Correctness of an in Vitro Researches as a Criterion of a MedicalLaboratory Diagnostics ObjectivityP.3. RELIABILITY OF MEASUREMENT INFORMATION IN THE “INDUSTRY 4.0” ERAP.4. EXCLUSIVE MEASUREMENTS

Section: I. GENERAL ASPECTS OF METROLOGY. MEASUREMENT METHODS.UNITY AND ACCURACY OF MEASUREMENTS

I.1. COMPLIENCE PROBABILITY DETERMINATION ON BASIS OF THE MONTE CARLOMETHODI.2. TRANSFER OF THE UNITS SIZE BY THE RANGE OF VALUES WITH USING THE STATEPRIMARY STANDARD OF THE UNITS OF ELECTRICAL CAPACITANCE AND DISSIPATIONFACTORI.3. REAL TIME SIGNAL PROCESSING UNDER INTENSE INTERFERENCEI.4. EXPERIMENTAL METHODS OF ASSESSING RELIABILITYI.5. SUPPLEMENTARY COMPARISON OF THE STANDARDS OF THE UNIT FOR ROUNDNESSMEASUREMENTS

Section: II. SENSORS, TRANSDUCERS AND DEVICES FOR MEASUREMENT OFPHYSICAL QUANTITIES

II.1. EXPERIMENTAL STUDY OF METROLOGICAL SELF-CONTROL CAPABILITY FORSTRAIN-GAGE PRESSURE TRANSDUCERSII.2. INSTRUMENT TRANSDUCERS FOR DETECTION OF THE PARAMETERS OFELECTROMAGNETIC PULSES OF NANOSECOND RANGEII.3. CURRENT PROBLEMS OF METROLOGICAL ASSURANCE IN THE FIELD OFMEASUREMENTS OF COATING THICKNESSII.4. INCREASE THE ACCURACY OF THE PROPAGATION TIME ESTIMATE OF THEULTRASONIC SIGNALS BY APPLYING DIGITAL PROCESSING METHODS IN A LIQUIDFLOW MEASUREMENT APPLICATIONSII.5. ARDUINO-BASED SYSTEM FOR HUMIDITY MEASUREMENTII.6. RESEARCH IN SURFACE TEMPERATURE MEASUREMENTS AT CZECH METROLOGYINSTITUTE (CMI), CZECH REPUBLICII.7. RESEARCH ON AIR-ELECTRONIC GAUGES AND METHODS FOR ELIMINATION OFINFLUENCING FACTORS

RESEARCH ON AIR-ELECTRONIC GAUGES AND METHODS FORELIMINATION OF INFLUENCING FACTORS

1) Miroslav Hristov 2) Georgi Dukendjiev1) Mag. Eng. "Mechanical Engineering and Instrumentation", Ph.D. student in theDepartment of Precision Engineering and Instrumentation, Mechanical Engineering

Faculty, Technical University of Sofia e-mail: [email protected] 2) mechanical engineer(1981). Professor (2015), PhD (1994), Department of Precision Engineering and

Instrumentation, Mechanical Engineering Faculty, Technical University of Sofia, ControlEngineering and Quality Management. e-mail: [email protected]

Abstract: Modern air gauges are directly related to the development of electronics andcomputers. This leads to some advantages associated with their exploitation. Comparedto conventional air gauges appliances in air-electronics we have a simple setup of themeasuring equipment, but it still remains complex and depends on the operator. Themain factors influencing the accuracy and metrological reliability of these devices are thesupply pressure, the non-linearity of the transformation function. These factors havebeen studied, their influence has been assessed and software offsets are proposed.Key-words: air gauges, accuracy, pressure regulatorPages from: 86 to: 90Language of the report: englishClick here for full text

Page 3: Section: P. PLENARY SESSION

II.8. METHODS FOR DETERMINING THE DYNAMIC CHARACTERISTICS OF INSTRUMENTSMEASURING PARAMETERS OF MOVING OBJECTSII.9. ABOUT ONE METHOD OF THE SURFACES COLORS MEASUREMENTII.10. CALIBRATION OF GAS FLOW METER WITH TEST BENCH ITF 2500-1-A

Section: III. MEASUREMENT AND INFORMATION SYSTEMS ANDTECHNOLOGIES

III.1. AUTOMATED CONTROL OF THE WATER LEVEL IN AN OBJECT BEING CONTROLLED(TECHNOLOGICAL TANK)III.2. MATHEMATICAL METHODS OF METROLOGY AND OPTIMIZATION APPLICATION INTHE DESIGN AND MODERNISATION OF TECHNIQUES AND DEVICES FORTHERMOPHYSICAL MEASUREMENTSIII.3. DIELECTRICS PARAMETERS MEASUREMENT WITH THE AID OF MICROWAVEMULTIMETERSIII.4. ASSESSMENT OF THE STATE OF THE COMPUTER SYSTEM BASED ON THE HURSTEXPONENTIII.5. ACCURACY OF MEASUREMENTS IN TERMS OF FPGA BASED CANNY EDGEDETECTIONIII.6. MEASUREMENT OF THE THERMO-EMF COEFFICIENT OF A SEMICONDUCTORMATERIAL FOR THE MANUFACTURE OF PELTIER THERMOELECTRIC MODULESIII.7. COMPARATIVE ANALYSIS OF INTERVAL CRITERIA FOR THE ENDING OF THETRANSIENT PROCESS IN THE MEASURING CIRCUIT

Section: IV. MEASUREMENTS IN THE INDUSTRYIV.1. THERMAL CONTROL FOR METAL CONDITION TESTING IN PIPELINES OF NUCLEARPOWER PLANTIV.2. METHODS OF MEASUREMENT AND CONTROL OF LEVELNESS AND FLATNESS OFINDUSTRIAL CONCRETE FLOORSIV.3. MEASUREMENT OF THE BURN UP OF SPENT FUEL DURING RELOAD FOR LONGTERM STORAGE IN CONSTOR 440/84IV.4. RESEARCH OF ALLOCATION EFFECT OF HEAT-RELEASING ELEMENTS TO THEOPTIMAL DIMENSION OF RADIO-ELECTRONIC DEVICESIV.5. DETERMINATION OF HEAT LOSS AND MICROCLIMATE PARAMETERS IN NON-PRODUCTION BUILDINGIV.6. METROLOGY ASSURANCE OF RADEYE SERIES SURFACE CONTAMINATIONMONITORSIV.7. THE NEED TO TAKE INTO ACCOUNT THE INFLUENCE OF MECHANICAL PARTS OFCONTROL LOOP ON THE OVERALL ACCURACY OF CONTROL IN I&C SYSTEMIV.8. PECULARITY OF METROLOGY ASSURANCE COORDINATE MEASUREMENTS OFGEOMETRICAL PARAMETERS OF THE SHAPED SURFACES.IV.9. MEASUREMENT OF GEOMETRY OF PARTS OF MAGNETIC SYSTEM OF NICA COMPLEXCOLLIDER

Section: V. MEASUREMENTS IN THE ELECTRICAL POWER ENGINEERINGV.1. RESEARCH OF INFLUENCE OF MAINS FREQUENCY DEVIATION ON VOLTAGESPECTRUM MEASUREMENT ERROR BY DFT METHODV.2. METHODS FOR METROLOGICAL CHECK OF MEASURING GENERATORSV.3. ROTORY DIODE FAILURE DETECTORV.4. APPLICATION OF THE BASIC STANDARDS FOR RADIATION PROTECTION OF 2012TO KOZLODUY NPP PLCV.5. CALIBRATION OF DIGITAL PRESSURE GAUGES, COMBINED PRESSURE GAUGES ANDVACUUM GAUGES

Section: VI. ACOUSTICS MEASUREMENTS, VIBRATION MEASUREMENTSAND DIAGNOSTICS

VI.1. MEASUREMENT OF CHANGE OF ULTRASONIC WAVES PHASE DUE TO PRESENCE OFLIQUID ON REFLECTIVE SURFACE

Page 4: Section: P. PLENARY SESSION

VI.2. EVALUATION OF UNCERTAINTY OF ACTIVE COMPONENT OF ULTRASONIC SHEARWAVES COMPLEX REFLECTION COEFFICIENT FROM THE LINE OF DEMARCATION SOLIDBODY – LIQUIDVI.3. METHODS OF MEASUREMENTS OF PARAMETERS OF THE ACOUSTIC FIELD CREATEDBY IONIZING RADIATIONVI.4. EVOLUTION AND EXTENSION OF SPECTRA'S OWN SOLUTION FOR MEASUREMENT,MONITORING AND REAL TIME DISPLAY OF ENVIRONMENTAL PARAMETERS (NOISE,VIBRATION, POWDER, METEO DATA, OTHER) - WEBNOISE.EU.VI.5. PRESENTATION OF THE RESULTS AND CONCLUSIONS OF THE REGULATORYSECOND ACOUSTIC PROJECT FOR THE NEEDS OF “SOFIA AIRPORT”, PERFORMED BYSPECTRY EOOD - A PART OF THE CONDUCTS PERMANENT MONITORING ANDMANAGEMENT OF SOIL IN THE ENVIRONMENT, FROM "SOFIA AIRPORT" EADVI.6. METROLOGICAL ASSURANCE, CONFIGURATION AND LAUNCH OF A NEW SPECTRITECHNICAL FIELD - SPECTROMETER, CALIBRATORS AND NOISE MEASURINGLABORATORY SPECTRI-LAB. ESTABLISHING ITS OWN METHODOLOGIES AND APPLYINGTHE RELEVANT INTERNATIONAL STANDARDSVI.7. IMPLEMENTATION OF THE REQUIREMENTS FOR THE ACCREDITATION OFEXECUTIVE AGENCY “BULGARIAN ACCREDITATION” SERVICES AND THE REQUIREMENTSOF THE STANDARD ISO / IEC 17020: 2012 TO THE SPECTRUM MEASUREMENT CONTROLAUTHORITY WITH SPEKTRI LTDVI.8. EQUIPMENT TESTING FOR ENVIRONMENTAL EFFECTS TO ENSURE SAFETRANSPORT

Section: VII. MEASUREMENTS IN THE ECOLOGY, BIOTECHNOLOGY,MEDICINE, AND SPORT

VII.1. AUTOMATION OF MEASUREMENT OF OBJECTS GEOMETRICAL PARAMETERSVII.2. COMPUTERIZED SYSTEM FOR INVESTIGATION OF ORGANIC MONOLAYERS AT THEAIR-WATER INTERFACE AND FOR DEPOSITION OF NANO THIN LAYERS FOLOWING THELANGMUIR AND BLODGETT METHODVII.3. PHOTOMETRIC FLICKER IN COMPUTER DISPLAYS BACKLIGHT AND A METHOD FORREDUCTION OF ITS HUMAN HEALTH EFFECTSVII.4. DISEASES OF INTERNAL ORGANS SUCH AS THE VALUE DEFINED BY USINGMEASUREMENTS SET OF PARAMETERS OF THE HEART RATEVII.5. MODERN ENGINEERING TECHNOLOGY FOR SWIMMING MEASUREMENTSVII.6. DEVELOPMENT OF SCIENTIFIC AND TECHNICAL CAPABILITIES OF THE BULGARIANINSTITUTE OF METROLOGY IN THE FIELD OF CHEMICAL ANALYSISVII.7. QUALIMETRY PEDAGOGICAL TECHNOLOGIES IN PHYSICAL CULTURE AND SPORTSVII.8. TOPICAL TASKS OF METROLOGY FOR DIAGNOSTICS OF INFANT’S BRAINPATHOLOGIES

Section: VIII. MEASUREMENTS IN HUMANITIESVIII.1. COMPUTER ANALYSIS OF MUSICAL SOUND AND PROBLEMS OF RESULTNOTATIONVIII.2. DIFFERENCES BETWEEN MEASURING DURATIONS IN THE LABORATORYEXPERIMENTS AND TIME MEASUREMENTS IN THE LIFE-SCIENCES AND HUMANITIESVIII.3. HUMANITARIAN MEASUREMENTS: PRINCIPAL PECULIARITIES (SYSTEMIC-INFORMATIONAL APPROACH)VIII.4. ‘REGRESSION TO THE MEAN’ IN CREATIVE ABILITIES: A TRIAL TO MEASURE THEPEDAGOGIC PROCESSVIII.5. ANALYSIS OF MULTIDIMENSIONAL PROBABILISTIC PROCESSES INPSYCHOLOGICAL EXPERIMENTSVIII.6. THE PERSONALITY OF THE STUDENTS DIFFERENT SPECIALIZATIONS

Section: IX. QUALITY MANAGEMENT AND CONTROL, STANDARDIZATIONAND CERTIFICATION

IX.1. THE CONTENTS AND THE DIFFERENCE BETWEEN THE TERMS „DESIGN“ AND„DEVELOPMENT“ IN THE QUALITY MANAGEMENT PROCESS „8.3 DESIGN AND DEVEL-

Page 5: Section: P. PLENARY SESSION

OPMENT OF PRODUCTS AND SERVICES“ ACCORDING TO THE ISO 9001:2015REQUIREMENTSIX.2. CONTROL STABILITY OF INDICATORS PRODUCT QUALITYIX.3. EFFICIENT SYSTEM FOR CONDUCTING QUALITY INSPECTION ON THE PRODUCTIONLINESIX.4. DETERMINATION OF SAMPLE SIZE IN STATISTICAL PROCESS CONTROL WITH ASET RISK OF INCORRECT DECISION-MAKINGIX.5. AUTOMATED SYSTEM FOR CONTROL AND MANAGEMENT OF A MACHINE FORAUTOMATIC ASSEMBLY OF CURTAIN BRACKETS AND HOOKSIX.6. ESTIMATION OF THE MEASUREMENTS’ ACCURACY DURING THE PRODUCTION OFTHE NEW LIQUOR "MENTINA"

Page 6: Section: P. PLENARY SESSION

86

RESEARCH ON AIR-ELECTRONIC GAUGES AND METHODS FOR ELIMINATION OF INFLUENCING FACTORS

Miroslav Hristov, Dukendjiev Georgi

Abstract: Modern air gauges are directly related to the development of electronics and computers. This leads to some advantages associated with their exploitation. Compared to conventional air gauges appliances in air-electron-ics we have a simple setup of the measuring equipment, but it still remains complex and depends on the operator.

The main factors influencing the accuracy and metrological reliability of these devices are the supply pressure, the non-linearity of the transformation function. These factors have been studied, their influence has been assessed and software offsets are proposed.

Key words: air gauges, accuracy, pressure regulator.

1. IntroductionAir-electronic gauges (AER) are constantly

evolving, with manufacturers' efforts aimed at re-ducing deficiencies and expanding their capabilities.

Permanent targets for improvement include metrological features and calibration methods for AER, measurement uncertainty reduction and increased reliability.

Despite the existence of various influencing factors on the accuracy of measurement with air gauges, one of the main components of the error is due to the change in supply pressure.

This error depends on the pressure regulators, which are one of the most important elements of AER.

2. Exploration of the characteristics of the IBR ae-1To determine the influencing factors, it is

necessary to study the static characteristics of

the measuring system. In this case, a function of transformation of the input magnitude is repre-sented in graphical form - displacement and the value reported by the device (Fig.1). It shows the change of the instrument reading in relative units vs. the linear displacement in μm. For this purpose a characterization was performed with 3 of the most common measuring nozzles - 1.5; 2 and 2.5 mm. The graphical representation is for a 2 mm nozzle.

In the middle part of the graph a relatively large linear region is observed. This section ap-proximates to linear as the error of non-linearity is below 2%. The non-linearity is 7.14% across the surveyed range.

Of particular importance is the hysteresis of the regulator (Fig. 2). It varies between 0.15 and 0.85 relative reading units on the digital display of IBR ae-1. Depending on the operation of the appliance, this may lead to a result error within ± 0,45 μm.

Fig.1 – Conversion function - relative unit to linear displacement in µm

Fig.1 – Conversion function - relative unit to linear displacement in µm

Display of device Right direction Display of device Reverse direction

µm µm

Page 7: Section: P. PLENARY SESSION

87

3. Pressure regulators.The correct choice of a pressure regulator is im-

portant in a metrological aspect when developing an air gauge. The solution requires familiarization with the operating conditions and principles of the regulator's operation. [1]

3.1. Types of pressure regulators:

In Fig. 3 a diagram of the non-amplifying pres-sure regulator is shown. The magnitude and stabil-ity of the working pressure is a function of several variables. The output of the analytical expression for H is based on the equation equilibrium force acting on the moving parts.

Fig.3 – Principal circuit of non-amplifier regulator: 1. valve; 2.membrane; 3.camera; 4. Inlet chamber; 5. throttle 6. spring; 7.vint; 8. spring

Fig.3 – Principal circuit of non-amplifier regulator: 1. valve; 2.membrane; 3.camera; 4. Inlet chamber;

5. throttle 6. spring; 7.vint; 8. spring

Therefore, the ability of regulators without amplification in terms of accuracy is too limited in terms of principle and construction. In this respect, regulators with an amplification are significantly superior. [1]

Fig.2 – Change hysteresis of IBR ae-1 in the range 0-70 µm.

Relative units

µm

Fig. 4 shows a schematic diagram of such a reg-ulator. There are four chambers: 1 and 6 with high pressure, 4 and 7 with working pressure. Even a slight change in working pressure ensures a strong increase (decrease) in air flow and hence great sen-sitivity of the regulator. The errors of this type of regulator caused by network pressure fluctuations and air consumption are significantly lower than those of the other type without an amplification, and a shift of the working pressure is practically not obtained. [1]

Fig.4 – Principal circuit of a regulator with amplification: 1. Input chamber; 2. valve; 3. membrane; 4. chamber with working pressure; 5. throttle; 6. a high pressure chamber; 7. chamber with working pressure; 8. Membrane; 9. Nozzle; 10. interception; 11. spring

Fig.4 – Principal circuit of a regulator with amplification: 1. Input chamber; 2. valve; 3.

membrane; 4. chamber with working pressure; 5. throttle; 6. a high pressure chamber; 7. chamber

with working pressure; 8. Membrane; 9. Nozzle; 10. interception; 11. spring

3.2. Pressure regulators offered by leading manufacturers:

One of the leading manufacturers of pressure regulators is SMC (Japan). For the purpose of the study we used two of their regulators:

- Simple (no amplification) - SMC AR20 F02H- Precision (with amplification) - SMC IR 1000The manufacturer presents the characteristics as

graphs representing the relationship between inlet and outlet pressure, consumption and hysteresis.

For the SMC AR20 F02H pressure regulators, according to the manufacturer's technical param-eters, a change in the outlet pressure is observed when the flow rate changes in a relatively small range [2,3]

Standard AERs work with inlet pressure ranging from 2-4 atm. Here, a group of curves with the clos-est characteristics is observed. A major problem in the application of AER in industrial conditions

Page 8: Section: P. PLENARY SESSION

88

where there are too many air consumers and there is a large change in the pressure to the pressure regulator. This leads to an additional stabilization error caused by the change in the rise and pressure reduction - hysteresis of the regulator. This error is around 0.1 atm.

Precision (with amplification) regulators have significantly improved performance. Again, the main influential factors here are related to the variable inlet pressure and the variable flow in industrial conditions. Here the errors that are ob-served are one order smaller than the non-amplified regulators.

4. Influence of SMC AR20 F02H and SMC IR 1000 on the accuracy of pneumatic-electron measuring instrument IBR-ae1.From the research done, the influence of the

pressure regulator on the pneumatic system IBR ae-1 is observed. The main parameters of the study are related to changes in the supply pressure and the influence it exerts on the outlet pressure of the regulators.

From graphically obtained results, for the SMC AR20 regulator, it can be concluded that when the supply pressure changes by 1 atm.in a normal range for industrial conditions of 3 to 6 atm, a change of the outlet pressure was observed by 0.02 atm. This change caused a ~ 1μm error in the investigated IBR ae-1 (Fig.5).

For the precision pressure regulator SMC IR 1000, the error of the input pressure fluctuation of 0.3 MPa causes an error in the IPR to be tested ~ 0.9 ÷ 1,3 μm (Fig.6)

Under real conditions, the oscillating pressure in the feed system rarely exceeds 1 atm, which may result in an error of ~ 0.3 μm

The main source of error in the pressure regu-lators is the hysteresis error at the supply pressure fluctuations (Fig. 7). With simple regulators, this error results in ~0.02 atm., and with the precision regulators of 0.004 to 0.008 atm. The reported result in a change in IBR ae-1 score of 1 μm in simple regulators (SMC AR20) and up to 0.5 μm in precision (SMC IR 1000)

Fig.5 – Graph of change in output pressure as a function of airflow at regulator SMC AR20

Page 9: Section: P. PLENARY SESSION

89

Fig.6 - Graph of change of output pressure as a function of input at regulator SMC IR1000

outp

ut p

ress

ure

(atm

.)

input pressure (atm.)

outp

ut p

ress

ure

(atm

.)

input pressure (atm.)

- right dir.

- revers dir.

- right dir.

- revers dir. - right dir.

- revers dir.

- right dir.

- revers dir.

outp

ut p

ress

ure

(atm

.)

input pressure (atm.)

Fig.7 – Hysteresis when changing the supply pressure of pressure regulators SMC AR20 and SMC IR1000

5. Opportunities to improve metrological and operational performance of AERsIn order to determine the dependence of the

influence factors on the AER transformation function, a regression analysis is required. The conversion function is nonlinear, but there is a lin-ear dependence between the change in the supply pressure and the change in the output parameter.

When changing the inlet pressure of the sys-tem, a family of curves and a relatively large linear region can be observed in the middle of the measuring range (Fig. 8). Based on these curves, a regression model can be calculated.

5.1. Reducing the non-linearity of the AER conversion function

The use of a regression model to calculate the conversion function introduces an error relative to the real transformation characteristic, but signifi-cantly reduces the error of the change in the input pressure. For the determination of the regression model we use an average value obtained after experimental dropping of the characteristic for different input value (linear displacement) in dif-ferent tooling (output nozzle) and different supply pressure values.

In the regression model a coefficient of cover-age between the real characteristic and the calcu-

Page 10: Section: P. PLENARY SESSION

90

lated Sm ~ 4% for the different curves is obtained. After correction of each value, a maximum error shall not exceed 0,5%

Because of the nonlinear nature of the conver-sion function, we have a fault of nonlinearity that can be compensated by importing a "fault map" in which correction values for different cases to construct approximation rights to be entered.

These actions help to directly increase the measuring range as the system can operate close to both ends of the transformation characteristic.

5.2. Compensation of supply pressure oscillation by introdction of „Error map“

The AER characteristics of the pressure reg-ulator used are pre-recorded. With the data thus obtained a database is created - "error map". For correction, it is necessary to monitor the inlet pressure change in operating mode. The resulting current value "subtracts" from the result correction database. Thus, the error of the AER indication is reduced by up to 5% depending on the working pressure and the used tooling.

6. ConclusionsThe influence of input pressure on the accuracy

of AER was studied. It is proposed to introduce into the measuring system a converter for input pressure reading and direct correction on the result by means of software compensation.

This improves the metrological characteristics of AER and simplifies the setup methodology.

The study is funded by NIS at the TU-Sofia under contract № 162ПД0034-06.

7. References[1] Semerdzhiev A., Avtomatizatsiya na kon-

trola v mashinostroeneto, S.Tehnika 1990[2] Dukendjiev G., R.Yordanov, Kontrol i

upravlenie na kachestvoto, Sofiya., Softtreyd, 2002[3] Modular Type Regulators Series AR.,

SMC Corporation, PDF Version 2009[ 4 ] P r e c i s i o n R e g u l a t o r s S e r i e s

IR1000/2000/3000, SMC Corporation, PDF Ver-sion 2009

Information for authors:Miroslav Hristov, Mag. Eng. "Mechanical

Engineering and Instrumentation", Ph.D. student in the Department of Precision Engineering and Instrumentation, Mechanical Engineering Faculty, Technical University of Sofia

e-mail: [email protected] Dukendjiev, mechanical engineer

(1981). Professor (2015), PhD (1994), Department of Precision Engineering and Instrumentation, Mechanical Engineering Faculty, Technical Uni-versity of Sofia, Control Engineering and Quality Management.

e-mail: [email protected]

Fig.8. Family curves as a function of the relative value of IBR ae-1 to linear displacement

at change of inlet pressure