FOUNDATION DETAIL SCALE 1/2"=1'-0" SECTION A-A - BASEPLATE ANCHOR BOLTS (6) REQ'D. PER FOOTING FOUNDATION PLAN SCALE 3/8"=1'-0" A A B B THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS ANY USE OF SAME WITHOUT THE EXPRESS WRITTEN PERMISSION OF VFS, LLC IS PROHIBITED SHEET NUMBER: CA1 of 2 SHEET TITLE: FOUNDATION PLAN SCALE: JOB NUMBER: DRAWN BY: CHECKED BY: 44522 AS SHOWN 137 Applewood Drive. Ilion, New York 13357 Phone: 315.865.0262 SITE: JJ SULLIVAN 229 RIVER STREET GUILFORD, CT 16'-0" x 36'-0" (2) COLUMN CANOPY JKS LRP 3'-6" SQUARE PIER 2 ' - 2 " P I E R 1'-10" EMBEDMENT (10) #5 BARS x 9'-6" LONG AT 6" C/C (TOP AND BOTTOM) 8 " 1 1/2" x 30" LONG HEADED ANCHOR ROD WITH LEVELING NUTS & WASHERS (ASTM F1554 GRADE 36) ON TOP OF & BELOW BASE PLATE 8" THREADED 2'-6" FOOTING NOTES 1. OWNER / GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FOOTING AND ANCHOR BOLT INSTALLATION. 2. ALL FOOTINGS SHALL BE CAST ON LEVEL UNDISTURBED SOIL, ROCK OR PROPERLY COMPACTED SUBGRADE. BOTTOM OF FOOTING TO BE ABOVE WATER TABLE. FOOTING SIZE BASED ON MINIMUM 2000 PSF SOIL BEARING CAPACITY AT BASE AND 150 PSF PER FOOT OF DEPTH LATERAL BEARING CAPACITY. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL SOIL PARAMETERS. 3. FOOTING CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 4. TOPS OF ALL FOOTINGS ARE ASSUMED TO BE AT SAME ELEVATION. OWNER / GENERAL CONTRACTOR SHALL PROVIDE BURIAL DEPTH FROM HIGH GRADE UNDER CANOPY. WHERE TOPS OF FOOTINGS ARE AT DIFFERENT ELEVATIONS, THE OWNER / GENERAL CONTRACTOR SHALL PROVIDE THE CANOPY MANUFACTURER WITH ALL FOOTING AND GRADE ELEVATIONS PRIOR TO CANOPY FABRICATION. VARIATIONS FROM DESIGN ELEVATIONS MAY RESULT IN INADEQUATE CLEARANCE AND UNDER SIZED FOOTINGS. 5. OWNER / GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PLACING NON-SHRINK GROUT UNDER ALL COLUMN BASES AFTER CANOPY IS LEVELED AND SECURED. 6. FOOTING REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 DEFORMED BILLET STEEL BARS WITH SPACING AS SHOWN ON DRAWING. 7. FOOTINGS ARE ASSUMED TO BE CONSTRAINED BY DRIVE MAT CONCRETE. WHERE THIS CONDITION DOES NOT EXIST, THE OWNER SHALL NOTIFY CANOPY MANUFACTURER. 8. ANCHOR BOLTS SHALL BE PLACED IN ACCORDANCE WITH THIS DRAWING. TEMPLATES SHALL BE USED TO ENSURE PROPER PLACEMENT OF ANCHOR BOLTS. ANCHOR BOLTS ARE TO BE INSTALLED SUCH THAT A MINIMUM OF 7" OF THREAD IS EXPOSED ABOVE TOP OF FOOTING. BOTTOM OF THREADS SHALL NOT END MORE THAN 3/4" ABOVE TOP OF FOOTER. PLATE 1"x20"x20" WITH GUSSETS (DETAIL D1/CA1) 4 ' - 0 " T O H I G H P O I N T O F G R A D E TEK 5 COLUMN 6"x6" COVER PLATE 5"x5" HAND HOLE HAND HOLE & COVER DETAIL D2 CA1 0 9/30/20 JKS PERMIT / APPROVAL REVISION HISTORY REV DATE BY DESCRIPTION 8 " 8 " SEE FOUNDATION DETAIL (TYP) LAWRENCE R. PILON, PE 51 MAPLEVIEW DR. PENNELLVILLE, NY. LICENSE # 017661 36'-3" 1 6 ' - 0 " 2 12 XABT1 (TEMPLATE) -XAB (1 1 2 "P x 30" ANCHORBOLT) FOR ANCHOR BOLT SHIPMENT 8" 20" 2" 8" 2" 2 " 1 6 " 2 " 2 0 " WOOD TEMPLATE 8" 8" TOP OF ALL PIERS AT SAME ELEVATION CONCRETE DRIVE 8 " 2 ' - 6 " F O U N D A T I O N (13) #5 BARS x 4'-6" LONG AT 9 1/4" C/C (TOP AND BOTTOM) 5'-0" SECTION B-B - PIER 2'-6" 2'-6" 8'-0" 2'-0" 10'-0" 3" CLEAR TYP. 1 6 ' - 0 " CONCRETE DRIVE 3'-6" SQUARE PIER 3 ' - 6 " 3'-6" (20) #6 VERTICAL BARS WITH 12" 90 HOOK 3 " 3 " 3 " 1 ' - 0 " T Y P ( U N O ) #4 HORZ. TIES AROUND PERIMETER (6) SIX LAYERS SPACING AS SHOWN BELOW 4 ' - 8 " 4 ' - 0 " 8 " 2'-0" 32'-0" 2'-3" 1 2 ' - 0 " 4 ' - 0 " 1 0 ' - 0 " 5'-0" 3'-6" 3 ' - 6 " #4 HORZ. TIES AROUND PERIMETER (6) SIX LAYERS SPACING AS SHOWN TOP OF FOOTING NON-SHRINK GROUT TO BE APPLIED & SUPPLIED AFTER CANOPY IS LEVEL & SECURED (BY OTHERS) BASEPLATE ANCHOR BOLTS: 1 1 2 "P x 30" LONG HEADED ANCHOR ROD W/LEVELING NUTS & WASHERS (F1554 GR 36) ON TOP OF & BELOW BASE PLATE CONDUIT AS REQ'D (BY OTHERS) 1 4 " TYP. 5 16 " (8) GUSSETS 3/8"x4"x4" COLUMN BASEPLATE DETAIL D1 1 " 2 " 20" x 20" CA1 50" 1 2 "

SECTION A-A - BASEPLATE SECTION B-B - PIER › wp-content › uploads › JJ-SULLIVAN-229-RIVE… · footing reinforcing steel shall be astm a615 grade 60 deformed billet steel bars

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • FOUNDATION DETAIL

    SCALE 1/2"=1'-0"

    SECTION A-A - BASEPLATE

    FOUNDATION DETAIL

    SCALE 3/8"=1'-0"

    SECTION B-B

    SECTION C-C

    ANCHOR BOLTS

    (6) REQ'D. PER FOOTING

    FOUNDATION PLAN

    SCALE 3/8"=1'-0"

    SECTION R-R

    SCALE 1/2"=1'-0"

    A

    A

    BB

    CC

    B B

    THESE PLANS ARE SUBJECT TO

    FEDERAL COPYRIGHT LAWS

    ANY USE OF SAME WITHOUT THE

    EXPRESS WRITTEN PERMISSION

    OF VFS, LLC IS PROHIBITED

    SHEET NUMBER:

    CA1 of 2

    SHEET TITLE:

    FOUNDATION PLAN

    SCALE:

    JOB NUMBER:

    DRAWN BY: CHECKED BY:

    44522

    AS SHOWN

    137 Applewood Drive.

    Ilion, New York 13357

    Phone: 315.865.0262

    SITE:

    JJ SULLIVAN

    229 RIVER STREET

    GUILFORD, CT

    16'-0" x 36'-0"

    (2) COLUMN CANOPY

    JKS LRP

    3'-6" SQUARE PIER

    2'-2"

    PIER

    1'-10"

    EMBEDMENT

    (10) #5 BARS x 9'-6" LONG

    AT 6" C/C (TOP AND BOTTOM)

    8"

    BU

    RY

    12'-0"

    3'-0"

    3'-0"

    (#) #7 VERT. BARS

    (#) #7 VERT. BARS

    #4 HORZ. TIES AT 12" CENTERS

    3" C

    LEA

    R

    ANCHOR BOLT TYP.

    HIGH POINT OF GRADE

    (4) #4 HORZ. BARS AT 16" CENTERS

    EACH WAY (4) FOUR LAYERS

    #4 VERT. BARS AT CORNERS

    AND AT CENTER OF EACH SIDE

    1 1/2" x 30" LONG HEADED ANCHOR

    ROD WITH LEVELING NUTS & WASHERS

    (ASTM F1554 GRADE 36) ON TOP OF &

    BELOW BASE PLATE

    8" THREADED

    2'-6"

    FOOTING NOTES

    1. OWNER / GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FOOTING AND ANCHOR BOLT INSTALLATION.

    2. ALL FOOTINGS SHALL BE CAST ON LEVEL UNDISTURBED SOIL, ROCK OR PROPERLY COMPACTED SUBGRADE.

    BOTTOM OF FOOTING TO BE ABOVE WATER TABLE. FOOTING SIZE BASED ON MINIMUM 2000 PSF SOIL BEARING

    CAPACITY AT BASE AND 150 PSF PER FOOT OF DEPTH LATERAL BEARING CAPACITY. CONTRACTOR SHALL BE

    RESPONSIBLE FOR VERIFYING ALL SOIL PARAMETERS.

    3. FOOTING CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI.

    4. TOPS OF ALL FOOTINGS ARE ASSUMED TO BE AT SAME ELEVATION. OWNER / GENERAL CONTRACTOR SHALL

    PROVIDE BURIAL DEPTH FROM HIGH GRADE UNDER CANOPY. WHERE TOPS OF FOOTINGS ARE AT DIFFERENT

    ELEVATIONS, THE OWNER / GENERAL CONTRACTOR SHALL PROVIDE THE CANOPY MANUFACTURER WITH ALL

    FOOTING AND GRADE ELEVATIONS PRIOR TO CANOPY FABRICATION. VARIATIONS FROM DESIGN ELEVATIONS

    MAY RESULT IN INADEQUATE CLEARANCE AND UNDER SIZED FOOTINGS.

    5. OWNER / GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PLACING NON-SHRINK GROUT UNDER ALL

    COLUMN BASES AFTER CANOPY IS LEVELED AND SECURED.

    6. FOOTING REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 DEFORMED BILLET STEEL BARS WITH SPACING

    AS SHOWN ON DRAWING.

    7. FOOTINGS ARE ASSUMED TO BE CONSTRAINED BY DRIVE MAT CONCRETE. WHERE THIS CONDITION DOES NOT

    EXIST, THE OWNER SHALL NOTIFY CANOPY MANUFACTURER.

    8. ANCHOR BOLTS SHALL BE PLACED IN ACCORDANCE WITH THIS DRAWING. TEMPLATES SHALL BE USED TO

    ENSURE PROPER PLACEMENT OF ANCHOR BOLTS. ANCHOR BOLTS ARE TO BE INSTALLED SUCH THAT A MINIMUM

    OF 7" OF THREAD IS EXPOSED ABOVE TOP OF FOOTING. BOTTOM OF THREADS SHALL NOT END MORE THAN 3/4"

    ABOVE TOP OF FOOTER.

    #4 HORZ. TIES AT 12" CENTERS

    (#) #7 VERT. BARS

    PLATE 1"x20"x20"

    WITH GUSSETS

    (DETAIL D1/CA1)

    1'-10"

    EM

    BED

    MEN

    T

    1'-0"

    MIN

    .

    LOW POINT OF GRADE

    (4) #3 TIES-TOP 12" AND

    AT 12" O.C. THEREAFTER

    6" LOCAL FROST

    LINE (MIN.)

    4'-0"

    TO

    H

    IG

    H PO

    IN

    T

    OF G

    RAD

    E

    TEK 5

    COLUMN

    6"x6" COVER PLATE

    5"x5" HAND HOLE

    HAND HOLE & COVER DETAIL

    D2

    CA1

    4'-0"

    TO

    H

    IG

    H PO

    IN

    T

    OF G

    RAD

    E

    COLUMN

    6"x8" HAND

    HOLE COVER

    TEK 5 TYP.

    4"x6" HAND HOLE

    HAND HOLE & COVER DETAIL

    D2

    CA1

    0

    9/30/20

    JKS

    PERMIT / APPROVAL

    REVISION HISTORY

    REV DATE BY DESCRIPTION

    8"

    8"

    SEE FOUNDATION DETAIL (TYP)

    LAWRENCE R. PILON, PE

    51 MAPLEVIEW DR.

    PENNELLVILLE, NY.

    LICENSE #017661

    36'-3"

    16'-0"

    2

    12

    XABT1 (TEMPLATE)

    -XAB (1

    1

    2

    " x 30" ANCHORBOLT)

    FOR ANCHOR BOLT SHIPMENT

    8"

    20"

    2"

    8"

    2"

    2"

    16"

    2"

    20"

    WOOD TEMPLATE

    8" 8"

    TOP OF ALL PIERS

    AT SAME ELEVATION

    CONCRETE DRIVE

    8"

    2'-6"

    FO

    UN

    DATIO

    N

    (13) #5 BARS x 4'-6" LONG

    AT 9 1/4" C/C (TOP AND BOTTOM)

    5'-0"

    SECTION B-B - PIER

    2'-6" 2'-6"

    8'-0" 2'-0"

    10'-0"

    3" CLEAR TYP.

    16'-0"

    CONCRETE DRIVE

    3'-6" SQUARE PIER

    3'-6"

    3'-6"

    (20) #6 VERTICAL BARS

    WITH 12" 90 HOOK

    3"

    3"

    3"

    1'-0"

    TYP

    (U

    NO

    )

    #4 HORZ. TIES

    AROUND PERIMETER

    (6) SIX LAYERS

    SPACING AS SHOWN BELOW

    4'-8"

    4'-0"

    8"

    2'-0" 32'-0" 2'-3"

    12'-0"

    4'-0"

    10'-0"

    5'-0"

    3'-6"

    3'-6"

    #4 HORZ. TIES

    AROUND PERIMETER

    (6) SIX LAYERS

    SPACING AS SHOWN

    TOP OF FOOTING

    NON-SHRINK GROUT TO BE

    APPLIED & SUPPLIED AFTER

    CANOPY IS LEVEL & SECURED

    (BY OTHERS)

    BASEPLATE

    ANCHOR BOLTS:

    1

    1

    2

    " x 30" LONG HEADED

    ANCHOR ROD W/LEVELING

    NUTS & WASHERS (F1554 GR 36)

    ON TOP OF & BELOW BASE PLATE

    CONDUIT AS REQ'D (BY OTHERS)

    1

    4

    "

    TYP.

    5

    16

    "

    (8) GUSSETS 3/8"x4"x4"

    COLUMN

    BASEPLATE DETAIL

    D1

    1"

    2"

    20" x 20"

    CA1

    50"

    12"

  • ELEVATION

    SCALE 5/16"=1'-0"

    FRAMING PLAN

    SECTION T-T

    SCALE 5/16"=1'-0"

    DETAIL U

    SCALE .05 : 1

    DETAIL V

    SCALE .05 : 1

    SECTION W-W

    SCALE 5/16"=1'-0"

    FASCIA DETAIL AT GUTTER SIDE

    DECK DETAIL

    U

    V

    Y

    AA

    THESE PLANS ARE SUBJECT TO

    FEDERAL COPYRIGHT LAWS

    ANY USE OF SAME WITHOUT THE

    EXPRESS WRITTEN PERMISSION

    OF VFS, LLC IS PROHIBITED

    SHEET NUMBER:

    CA2 of 2

    SHEET TITLE:

    FRAMING PLAN

    SCALE:

    JOB NUMBER:

    DRAWN BY: CHECKED BY:

    44522

    AS SHOWN

    137 Applewood Drive.

    Ilion, New York 13357

    Phone: 315.865.0262

    SITE:

    JJ SULLIVAN

    229 RIVER STREET

    GUILFORD, CT

    16'-0" x 36'-0"

    (2) COLUMN CANOPY

    JKS LRP

    STEEL NOTES

    1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE LATEST AISC

    SPECIFICATIONS. DESIGN, FABRICATION AND ERECTION OF COLD FORMED STEEL SECTIONS SHALL

    CONFORM TO THE LATEST AISI SPECIFICATIONS.

    2. STRUCTURAL MATERIALS:

    WIDE FLANGE SECTIONS - ASTM A992 OR A572 GRADE 50 (Fy = 50 KSI)

    ANGLES / CHANNELS - ASTM A36 (Fy = 36 KSI)

    HOLLOW STRUCTURAL SECTIONS (TUBE) - ASTM A500 GRADE B (Fy = 46 KSI)

    PIPE SECTIONS - ASTM A53, GRADE B (Fy = 35 KSI)

    PLATE - ASTM A36 (Fy = 36 KSI)

    ROOF DECK - ASTM A653, GRADE 50 (Fy = 50 KSI), GALVANIZED (G60) WITH FULL COAT OF POLYESTER

    PAINT BAKED ON OVER AN EPOXY PRIMER.

    STEEL OUTRIGGERS - ASTM A653 GR. CS (Fy = 25 KSI), GALVANIZED (G90) PER ASTM 924

    STRUCTURAL BOLTS - ASTM A325

    ANCHOR BOLTS - ASTM F1554 GR. 36; ASTM A36; OR ASTM A307 MATERIAL (Fy = 36 KSI)

    3. WELDING OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH LATEST ANSI / AWS D1.1

    4. FIELD CONNECTIONS SHALL BE BOLTED CONNECTIONS UNLESS SPECIFIED ON DRAWING.

    5. ALL STRUCTURAL BOLTED CONNECTIONS SHALL USE ASTM A325 BOLTS. BOLTED JOINTS SHALL BE

    TIGHTENED TO SNUG TIGHT PER LATEST RCSC SPECIFICATION.

    6. STRUCTURAL STEEL SHALL BE SHOP COATED WITH A RED-OXIDE RUST INHIBITIVE PRIMER. FIELD

    TOUCH-UP, FINISH PAINTING, AND MAINTENANCE SHALL BE THE RESPONSIBILITY OF THE OWNER

    (UNLESS OTHERWISE SPECIFIED).

    7. DESIGN LOADS PER 2018 CT BUILDING CODE (2015 IBC W/ CT AMENDMENTS) REQUIREMENTS:

    RISK CATEGORY II

    ROOF LIVE LOAD = 30 PSF

    FLAT ROOF SNOW LOAD = 30 PSF

    BASED ON GROUND SNOW LOAD= 30 PSF

    WIND LOADS:

    LATERAL = +/- 35 PSF (MWFRS)(USING 0.6 W FOR ASD)

    UPLIFT = +/- 20 PSF (MWFRS)(USING 0.6 W FOR ASD)

    BASED ON 135 MPH ULTIMATE WIND SPEED PER ASCE 7 EXPOSURE "B"

    IMPORTANCE FACTOR = 1.0

    SEISMIC LOADS:

    OCCUPANCY CATEGORY II, SITE CLASS "D" ASSUMED

    SEISMIC DESIGN CATEGORY "B"

    Sds = 0.188G (Ss = 0.176, Fa = 1.6), Sd1 = 0.098G (S1 = 0.061, Fv = 2.4)

    SEISMIC FORCE RESISTING SYSTEM IS NON-BLDG INVERTED PENDULUM - CANTILEVERED COLUMN, R = 2

    Cs = 0.094, DESIGN BASE SHEAR = CsxW = 0.5 KIPS / COLUMN USING EQUIVALENT LATERAL FORCE

    PROCEDURE

    DEAD LOADS:

    DECK / GUTTER / LIGHTS - 5 PSF

    FASCIA - 15 PLF

    STRUCTURAL STEEL - SELF WT

    CONCRETE - 145 PCF

    8. CANOPY USE GROUP M / CONSTRUCTION TYPE II-B

    BOLT TABLE

    MK.

    QTY.

    TYPE OF BOLT NO. OF LOCATIONS

    A 4

    3/4" DIA. X 2 1/2" BOLTS A-325

    2

    B 8

    3/4" DIA. X 2 1/2" BOLTS A-325

    3

    C 4

    3/4" DIA. X 2" BOLTS A-325

    3

    D 3

    3/4" DIA. X 2" BOLTS A-325

    3

    E 2

    3/4" DIA. X 2" BOLTS A-325

    3

    ALL STRUCTURAL BOLTED CONNECTIONS SHALL USE ASTM A-325 BOLTS.

    BOLTED JOINTS SHALL BE TIGHTENED TO SNUG TIGHT PER LATEST RCSC SPECIFICATION.

    TURN MARK NUMBERS ON BEAMS THE SAME AS SHOWN ON PLAN

    18GA.x2"x2" GALV. KNEE BRACE (#KB1) LOCATE

    AT EACH PURLIN AND FASTEN TO NEAREST OUTRIGGER

    18GA.x2"x2" GALV. KNEE BRACE (#KB1) LOCATE

    AT 8'-0" O.C. AND FASTEB TO NEAREST OUTRIGGER

    TOP OF PIER

    ABOVE CONCRETE DRIVE

    0

    9/30/20

    JKS

    PERMIT / APPROVAL

    REVISION HISTORY

    REV DATE BY DESCRIPTION

    EXTERIOR DOWNSPOUT SEE DETAIL GX/E1

    (SEE FOUNDATION PLAN FOR DIRECTION)

    INTERIOR PVC DOWNSPOUT

    SEE DETAIL G11/CA2

    DECK PANEL 20GA.x3"x16"

    IRG WHITE EMBOSSED

    LAWRENCE R. PILON, PE

    51 MAPLEVIEW DR.

    PENNELLVILLE, NY.

    LICENSE #017661

    8"

    8"

    TOP OF PIER

    ABOVE

    CONCRETE DRIVE

    * ALL STRUCTURAL STEEL *

    TO BE HOT DIP GALVANIZED

    GUTTER

    FASCIA

    3"x4" OUTLET

    3"x4" ELBOW

    3"x4" DOWNSPOUT

    COLUMN

    DECK

    DOWNSPOUT DETAIL

    3"x4" ELBOW

    36'-0"

    36'-0"

    1

    1

    2

    "

    DECK

    PURLIN

    FASCIA: ACM

    COLOR: PROGRAM WHITE

    FASCIA

    2'-0" 32'-0" 2'-3"

    36'-3"

    12'-0"

    4'-0"

    16'-0"

    3'-0"

    10'-4"

    2'-8"

    CB1

    W14x30

    CB1

    W14x30

    PB2

    W10x26

    PB1

    W10x26

    COLUMN (TYP)

    HSS-12"x12"x1/2"

    PURLIN

    2-1/2" x 18GA x 5'-0" CEE STUD

    ATTACH AT FIRST / LAST 4 PANELS

    EACH END OF CANOPY

    (2) #14 x 7/8" LAPTEK

    12" OC

    3

    16

    "

    PURLIN

    PURLIN

    CROSSBEAM

    CROSSBEAM

    3

    4

    " A-325 BOLTS & NUTS

    (4 PER CONNECTION)

    CROSSBEAM TO PURLIN CONNECTION

    S21

    PL-1/4"

    STIFFENER

    TYP

    CA2

    ( ) PLACES

    CROSSBEAM

    3/4" A-325 BOLT & NUT

    ANGLE 3x3x3/16"

    PURLIN

    1/4" STIFFENER

    CROSSBEAM BRACE DETAIL

    2

    S45

    3/16"

    CA2

    CROSSBEAM

    CROSSBEAM1/4" STIFFENER

    (NS / FS)

    CAP PLATE

    COLUMN

    TYP

    3

    16

    "

    1

    4

    "

    PL-

    3

    4

    " A-325 BOLTS & NUTS

    (8 PER CONNECTION)

    3

    8

    " GUSSET

    CROSSBEAM TO COLUMN CONNECTION

    3/4" x 14" x 24"

    S11

    CA2

    ANGLE 3x3x3/16"

    PURLIN

    3

    4

    " A-325 BOLTS & NUTS

    ANGLE LATERAL BRACE

    S31

    CA2

    #12 X 1-1/4" TEK 5 W/ WASHER

    (3) PER DECK PAN AT PURLIN

    S11

    CA2

    S21

    CA2

    S21

    CA2

    S45

    CA2

    SA7-a14

    L-3"x3"x3/16"

    LATERAL BRACE

    (TYP 4 PLCS)

    S31

    CA2

    SA7-a122

    L-3"x3"x3/16"

    LATERAL BRACE

    (TYP 3 PLCS)

    S31

    CA2

    S31

    CA2

    SA7-a147

    L-3"x3"x3/16"

    LATERAL BRACE

    (TYP 2 PLCS)

    S31

    CA2

    S31

    CA2

    6

    "

    1"

    CANOPY INSTALLER TO FIELD

    CUT & BEND TO FORM

    OVERFLOW OPENING

    CANOPY

    GUTTER

    CA2

    FIELD CUT GUTTER OVERFLOW DETAIL

    G3

    G3

    CA2

    G3

    CA2

    10'-0"12'-0"10'-0"

    36'-0"

    3'-0"

    CROSSBEAM

    19'-9" TO

    TO

    P O

    F PIER

    19'-9"

    GUTTER

    7

    1

    2

    "

    5"

    DECK

    18GA BACKER

    (FULL HEIGHT)

    18GA ZEE x 35" LONG

    AT 24" OC

    GUTTER HANGER

    18GA HAT CHANNEL

    1-1/2" TALL x 24" LONG

    (3) #10x3/4" TEKS PER CHANNEL

    18GA

    KNEE BRACE

    AT 24" OC

    ALL FASTENERS #10x3/4" TEKS AT 24"OC

    UNLESS NOTED OTHERWISE

    19'-9

    7 8

    "

    3'-0"

    SEE DOWNSPOUT DETAIL