8/7/2019 seccant dryers
1/8
KOMPRESSOREN
SECCANT REGENERATIVE DRYER
FOR AIR AND GAS
Reliably dried air and gases atlow operating costs. Whetherthe system is running conti-nuously or intermittently. Evenat a high air flow rate. That is
the BAUER KOM PRESSORENSECCANT'S strong point.
8/7/2019 seccant dryers
2/8
Maintenance-free run-ning for more economicefficiency
The SECCANT regenerativedryer effectively protectspipelines and valves fromcorrosion, icing and dirt.
Long running periods andmaintenance-free operationmake the application particu-larly economical.
To achieve maximum effi-ciency, the SECCANT is desi-gned for continuous run-ning.
Air/gas is constantly availa-ble. Operational interrup-tions due to changing filtercartridges, which arenecessary with standard f il-ter systems, are thereforeeliminated.When running intermit-tently, rinsing times arenot needed.
Regeneration merely needs apartial stream of maximum5% of the dried medium.
The pressure vessels aredesigned and manufacturedaccording to most nationaland international specifica-tions for acceptance.
Optional: With the help of an
additional filter housing con-taining activated carbon,breathing air quality accor-ding to DIN EN 12021 can beobtained.
1
4
2
3
3
TO DRY AIR AND GASES SAFELY
SECCAN T - THE M OST ECON OM IC WAY
8/7/2019 seccant dryers
3/8
PUREBR
EATHING
AI
R
KOMPRESSOREN
FOR
YOUR
SAFE
TY
KOMPRESSOREN
The B-CONTROL
fully automatically controlsall processes such as cycletimes, pressure compensation,change-over and condensatedraining. The large, eight lineLCD display with free languagechoice* provides informationon all important parameters.
* 7 languages at present5
6
7
1
The quality seal of an original BAUERcartridge stands for purest breathing air
The condensate separator
removes condensed water andoil drops from the incomingflow of air/gas.
2
The dryer chambers
are connected in a push-pulloperation. The incomingair/gas flow is dried in the firstchamber (e.g in left fig.) usinga partial stream with alreadydried air, the second chamberis being regenerated (e.g inright f ig.).The regenerating air is chan-
nelled through the chargedadsorption medium and rege-nerates the adsorber with thehelp of the partial decrease ofline pressure.
3
The change-over module
consists of main stream - as well
as regeneration stream checkvalves and compensates thepressure between the dryingchambers with a well desi-gned change-over.
4
The filter housing
with activated carbonremoves oil vapour andhydrocarbons from theairflow.The treated air correspondsin quality to pure air inaccordance withDIN EN 12021.(Optional in the regenerativedryers of the SECCANT 3A / 4A
range).
5
The particle f ilter
filters all particles from driedand deoiled air. Subsequentlythe air/gas flow is directed via
a pressure maintaining/check-valve to the connectedsystems.
6
The shut-off valve
for the regenerating air closesduring pressure compen-sation and when theSECCANT is switched off.
This allows a change-overwithout pressure drop inthe system and stops thehumidity penetrating fromoutside.
71 - B-CONTROL
2 - condensate separator
3 - dryer chambers
4 - change-over module
5 - purifier (optional-A models)
6 - particle filter7 - pressure maintaining
non-return-valve
8/7/2019 seccant dryers
4/8
YOUR SECCAN T'S COM M UN ICATION CENTRE
THE B-CONTROL
SECCANT 3 / 3A / 4 / 4A
B-M ESSENGERinforms online
the unit operator via SMS onhis/her mobile phone orpager or via fax about allimportant compressor data.
About pending maintenancework, for example or withmodels 3A and 4A about apending filter change.
Continuous control main-tains operational security
B-CONTROL fully automati-cally monitors and controlsall SECCANT'S internal func-tions like- Operating hours- Operating reports- SECURUS (optional)- Pressure dew point
(optional)
At the same time SECCANT'SB-CONTROL communicateswith the compressor's respec-tive unit control:
At start and stop the com-
pressor unit sends SECCANTan On/Off signal. SECCANTpermanently monitors itselfduring operation and sendsthe compressor a releasesignal.
If a release signal is notreceived, due to necessarymaintenance for example,the compressor is automa-tically stopped.
If the compressor unit isequipped with a B-CONTROLextended control andconnected to SECCANT via aCAN-Bus, online control andonline monitoring of SECCANTand the compressor unit canbe realised via an external
control room.As an SPC control B-CONTROLensures the unit can be pro-grammed according to custo-mer requirements.
8/7/2019 seccant dryers
5/8
KOMPRESSOREN
1
1
2
3
3
On/Off signal from the compressor unit to SECCANT
Stand by report from SECCANT to the compressor unit
Status report from SECCANT to the B-CONTROL of the compressure unit
Compressur unit swithout B-CONTROL
Compressur unitswith B-CONTROL
CAN-Bus
Standard connection 4
4 Forwarding of operat ing reports by B-MESSENGER via Fax, e-mail or SMS
8/7/2019 seccant dryers
6/8
CUSTOM -M ADE SOLUTION S
W ITH SYSTEM ENGINEERIN G
The appropriate configu-ration for each purpose
The four models 3, 3A,4 and 4 A of BAUER' SSECCANT range offer acustom-made system solu-tion for dehumidification
as well as purifying air,inert gases and rare gases.
When wiring in the conven-tional way up to three com-pressors can be connectedto the SECCANT, when usinga CAN-Bus as many com-pressors needed to obtainthe maximum delivery
quantity can be connected.
Interconnected operationcan be achieved with helpof the B-CONTROL using aCAN-Bus.
Two SECCANT and 2 com-pressors can be installed incrosswise operation. Thatway, for maintenance modeany combinations betweenthe connected compressorsand SECCANT are possible.
For strictly continuousoperation solutions, whereprocesses do not allow any
interruptions, there is alsothe possibility of a combinationusing a BAUER P rangebypass filter system.
K 22 Range
VERTICUS / KAP Range
K 23 Range
K 25/28 Range
8/7/2019 seccant dryers
7/8
KOMPRESSOREN
User
Bypass filter system
SECCANT 3 / 3A
Storage system
SECCANT 4 / 4 A
8/7/2019 seccant dryers
8/8
TECHNICAL DATA
Seccant-E 3.05. 1St subject to technical modif ications
BAUER KOMPRESSOREN GmbH
P.O.BOX 710260 . D-81452 MNCHEN
DRYGALSKI-ALLEE 37 . D-81477 MNCHEN
PHONE 0049 89 78049-0
FAX 0049 89 78049-167
Internet: www.bauer-kompressoren.dee-mail: [email protected]
KOMPRESSOREN
required to fulfill the regulation
Flow rate max.l/min / scfm
1500 / 55
90 - 4201300 - 6100
150
10
15
5
2000 2000 2000 2000
5 5 5
15 8 8
10 12 12
182 330 360
D 26W 115H 125
D 26W 165H 129
D 260W 1645H 1285
D 26W 135H 125
90 - 4201300 - 6100
90 - 4001300 - 5800
90 - 4001300 - 5800
1500 / 55 3500 / 129 3500 / 129
Nominal pressurebar / psig
DimensionsD x W x H /cm
Weightkg
Air / gasconnection mm
Condensate connection mm
Electricsupply
Filter change intervalsh
Regeneration air/ gas volume% of the compressor flow
SECCANT 3 3a 4 4a
1 phase 230 V 50/60 Hz or 24V DC
Breathing airacc. to
DIN EN 12021
Medical air *acc. to European
Pharmacy Regulations
Industrial air/CNGPurification
focuson
Nitrogen/Rare gases
Industrial airacc. to
DIN EN ISO 8573-1Oil content class 2humidity class 3
SECCANT 3
SECCANT 3A
SECCANT 4
SECCANT 4A
* CO2 removal by a separate system