4
SEC BATTERY RANGE RECYCLE LEAD RETURN Pb Industrial Battery Co. SEC Supplied Worldwide by: Visit our website at www.secbattery.com CELLYTE 2CMT/2TLAM/G Range with Catalyst SEC ETG OPzV Range with optional Catalyst

SEC BATTERY RANGE - truonggiangchulai.comtruonggiangchulai.com/Documents/Brochure-SEC.pdf · SEC BATTERY RANGE RECYCLE L E A D R E T U R Pb N SEC ... SE C/DIN TY P S .GR AVIT CAPA

Embed Size (px)

Citation preview

SEC BATTERY RANGE

RECYCLE

LE

AD

RE

TU

RNPb Industrial Battery Co.SEC

Supplied Worldwide by:

Visit our website at www.secbattery.com

SEC Industrial Battery Co.

SEC/DIN TYPE SP.GRAVITY

CAPACITY DATE

1.240

SEC Industrial Battery Co.SEC/DIN TYPE SP.GRAVITY

CAPACITYDATE

1.240

SEC Industrial Battery Co.

SEC/DIN TYPE SP.GRAVITY

CAPACITY DATE

1.240

CELLYTE 2CMT/2TLAM/G Range with Catalyst

SEC ETG OPzV Rangewith optional Catalyst

With Catalyst

With Catalyst

With Catalyst

CAPACITIES : 40 Ah to 175 Ah at C/10 to 1.75 VpcDESIGN LIFE : 12 years fitted with Catalyst in float service at 20C

CELLYTE 12FTA Bloc sealed lead acid VRLA 12 Volt Monobloc Front terminal battery range.The first battery in the world fitted with VRLA Monobloc Catalyst.CELLYTE FTA Bloc advanced AGM absorbed electrolyte technology ensures reliableperformance, safety, outstanding battery life and value, comply with BS 6290 Part 4 with flame retardant V-0 case and IEC 60896-21/22-2004.CELLYTE FTA Bloc batteries also comply with the latest specifications of the Power and Telecommunications Industry.

With Monobloc Catalyst

CELLYTE 2TLAM & G Tubular or Modular free standing 2 volt cells / batteries AGM or Gel Technology - with Catalyst.Sealed Valve Regulated Maintenance Free Lead Acid Batteries - for StandbyApplications. Free standing cells can be used in vertical or horizontal position inconventional racks or can be supplied in Zone 4 rated Seismic Modular racks. Fully complies with BS 6094 - Part 4 with flame retardant V-0 case, IEC 60896-21/22 - 2004 Capacity:100Ah to 3000Ah at C/10 to 1.80 Vpc at 20C.800 Cycles Design life 15 years with Catalyst

CELLYTE 2CMT Modular & Tubular free standing 2 volt cells /batteries AGM with Catalyst.Sealed Valve Regulated Maintenance Free Lead Acid Batteries - for StandbyApplications using Virgin Pure lead /1.6%Tin alloy for positive plate. Free standing cells can be used in vertical or horizontal position in conventional racks or can be supplied in Zone 4 rated Seismic Modular racks or Zone 0 tubular rack. Fully complies with BS 6094 - Part 4 , IEC 60896-21/22 - 2004 Capacity:100Ah to 4500Ah at C/10 to 1.80 Vpc at 20C.1200 Cycles Design life 20 years with Catalyst

CELLYTE 6/12TLA Monoblocs

CELLYTE 6/12TLA Bloc - Sealed AGM VRLA monobloc batteries CELLYTE 12TLA Bloc sealed valve regulated rechargeable batteries are maintenance free.CELLYTE 12TLA Bloc advanced AGM absorbed electrolyte technology ensures reliable performance, safety, outstanding battery life and value. The batteries comply with BS 6290 Part 4 with flame retardant V-0 case,IEC 60896-21/22-2004. CELLYTE 12TLA Bloc batteries also comply with the latest specifications of the Power and Telecommunications Industry.

CAPACITIES : 15 Ah to 240 Ah at C/10 to 1.80 VpcDESIGN LIFE : 10 years in float service at 20C

With Monobloc CatalystCELLYTE TUA Range

CELLYTE 2-12TUA Range Sealed VRLA Monobloc AGM BatteriesCELLYTE TUA Range Monobloc valve regulated rechargeable batteries supplied with Monobloc Catalyst to enhance battery performance, life and capacity. Designed for use in High Integrity Telecom, UPS and Standby Power applications.Complies withor exceeds BS 6290 - Part 4 , IEC 60896-21/22-2004 specifications. Capacity: 20Ah to 230Ah C/10 to 1.80 vpc at 20 C. Design life: 12 years with Catalyst

CELLYTE 2CMT Modular

CELLYTE 2TLAM/G Tubular

CELLYTE 12FTA/G Range

CELLYTE 2CMT/ 2TLAM/G Range

CELLYTE 2CMT or 2TLAM & G cells are in AGM or Gel manufacturedwith heavy duty ABS cover and case and thus can be offered as free standing cells for use in the horizontal or vertical position.

Design life - 15 to 20 yearsCapacity - 100Ah. to 4500Ah. at C/10

CAPACITIES : 6 Volt 1.3Ah to 12 Volt 250AhDESIGN LIFE : 5 to 8 Years in float service at 20C

CAPACITIES : 6 Volt 12Ah to 12 Volt 250AhDESIGN LIFE : 8 - 10 Years in float service at 20C

MICROLYTE Plus - Maintenance-free rechargeable sealed lead acid batteries

* Maintenance free * Leak proof / spill proof * Gas recombination * Absorbed electrolyte * Float / cycle use * Low self discharge rate* Safety valve * Lead calcium alloy * Useable in any position * Rugged design * Available in flame retardant ABS material (optional)

MICROLYTE Plus Range

MICROLYTE Red Top Range

CELLYTE 2TLA /G Range

CAPACITIES AGM: 50 Ah to 3850 Ah at C/10 to 1.75 Vpc Gel: 50Ah. to 1000Ah at C/10

DESIGN LIFE : 15 years in float service at 20C

CELLYTE 2TLA/G - Sealed Lead Acid VRLA 2 Volt Flat Pasted Plate Battery Range

SEC -2TLA 2 Volt sealed valve regulated rechargeable batteries with advancedAGM absorbed electrolyte technology batteries have a design life of 15 years at 20C and comply with BS 6290 Part 4 with flame retardant V-0 case IEC 60896-21/22 -2004.

With Catalyst

With Optional CatalystCELLYTE ETG DIN OPzV Range

CELLYTE ETG Gel RANGE - VRLA Tubular Plate Gel Batteries OPzVSealed Valve Regulated Gel Maintenance Free Lead Acid BatteriesFully recyclable GVR lead acid batteries manufactured to comply withDIN 40736 Part 3, IEC 60896-21/22-2004.

DESIGN LIFE : 15 Years in Float Service at 20C

at 20C 1200 Cycles CAPACITY : 200Ah to 3000 Ah. C/10

MICROLYTE Red Top - Maintenance-Free Rechargeable VRLA Lead Acid

Cyclic Batteries

MICROLYTE MRT batteries are designed for universal float service and cyclic applications. Battery life will depend on frequency and depth of discharge and temperature of operation. UL Recognised Component under MH 28022

With Monobloc CatalystCELLYTE 6-12TSG Range

CELLYTE 6-12TSG Solar Gel Range VRLA Deep Cycle Gel Batteries CELLYTE TSG Solar range valve regulated rechargeable batteries fitted with Monobloc Catalyst to enhance battery performance, life and performance at temperatures up to 30 C. Designed for use in daily cyclic renewable PV Solar energy applications in remote areas where reliable dependable electricity storage applications. Capacity: 50Ah to 250Ah C/100 to 1.80 vpc at 20-30 C. Design life up to 10 years with Catalyst in cyclic or float service

CELLYTE 12TLG Bloc

CELLYTE 12TLG Bloc - Sealed Gel VRLA Monobloc batteries SOLAR POWER AND DEEP CYCLE BATTERY

CAPACITIES : 20Ah to 280Ah at C/100 to 1.75 VpcDESIGN LIFE : 10 years in float service at 20C

CELLYTE 12TLG Bloc Gel, sealed valve regulated lead acid rechargeable batteries are maintenance free. Advanced gelled electrolyte gas recombination technology ensures reliable performance, safety, outstanding battery life and value. CELLYTE 12TLG batteries are designed for universal float service / deep cycling applications.

Catalyst Reduces Float CurrentOne of the most immediate, observable effects of installing a catalyst in a VRLA cell is a sudden drop in the floatcurrent..Typically float currents are one half or less when a catalyst is installed. Adding a catalyst to the cell prevents some of the oxygen reaching the negative plate and allows the negative plate to stay polarised. This means that less current needs to be supplied to the cell from the charging system, manifesting itself as lowerfloat current, leading to the following benefit :-

* Minimize water loss Gasses are recombined into water inside the cell rather than exiting the cell. Too much gas leaving the cell can lead to premature dry-out and cell failure. Cell dry is a major cause of VRLA cell failure. .* Increased life There are many potential failure modes of VRLA cells. A number of these failure modes can be mitigated by the catalyst technology such as: Cell dry out, positive plate corrosion, thermal runaway, capacity loss due to negative plate depolarization. * Minimize positive plate corrosion A reduction in float current reduces the amount of over- charge on the positive plate which directly impacts the corrosion rate. The design life of a lead acid cell is based on the corrosion of the plate barring any other unforeseen failure modes.

* Maintain cell capacity Many VRLA cells in service are failing capacity tests because their negative plates are depolarized In fact significant capacity increases have been seen on some cells just by installing a catalyst.

Benefits of Catalyst in SEC VRLA Batteries

SEC Head OfficeSEC Industrial Battery Co.Ltd.

Thorney Weir House, IverBucks SLO 9AQ, ENGLAND

Tel. 44 (0)1895 431543 Fax. 44 (0)1895 431880 europ eanoffice@ secbattery.com

SEC Industrial Battery Co.BscP.O.Box 32225Kingdom of BahrainTel: 97317 721322Fax: 97317 [email protected]

SEC Industrial Battery Co.Ltd.Unit 6, 6/f, Hewlett CentreNo. 54 Hoi Yuen Road, Kwun Tong Kowloon, Hong KongTel: 852 230 44382Fax: 852 230 [email protected]

The USA Sales Office1643 Holicong RoadPO Box 849 Buckingham,PA 18912, U.S.A.Tel: 1 215 654 9334Fax: 1 215 654 9871 [email protected]

SEC Corby OfficeSEC Industrial Battery Co. Ltd.

Unit 16 Alexander Court, Fleming Road, Earlstrees Ind. Est. Corby,

Northants, NN 17 4SWTel: 01536 264123 Fax: 01 536 264126

[email protected]

SEC SECIndustrial Battery Co. Industrial Battery Co.

Visit our website on www.secbattery.com

SEC NICKEL CADMIUM - POCKET PLATE Design life 20+ years

‘L’ Series Type KL...P-For Long Discharge Rate ( Above 3 Hrs.)11Ah to1250 Ah ‘M’ Series Type KM..P-For Medium Discharge (30 mins up to 3hrs.)18Ah to1250Ah ‘H’ Series Type KH...P-For High Discharge Rate (seconds up to1hr.) 10Ah to 250 Ah

Nickel Cadmium Pocket Plate batteries are available for a wide range of applications.

SEC Nickel-Cadmium Range

SEC Tubular OPzS Range

CAPACITIES : T-Range 100 Ah to 3000 Ah at C/10 to 1.80 Vp DESIGN LIFE : 15 years in float service at 20C

This range is specifically designed for stationary installation where cyclicdischarge may occure

TUBULAR PLATE OPzS Range Flooded Stationary Lead Acid Batteries with Tubular Positive Plates. Conforms to Din 40736

SEC Plante PS & PL RangeCAPACITIES : 75Ah to 450Ah & 500 Ah to 2000 Ah at C/10 to 1.80 Vpc

DESIGN LIFE : 20 years in float service at 20C

PLANTE POSITIVE PLATE Stationary Lead Acid Batteries withHigh Performance Plante Positive Plates to DIN type GroE40738-06/1991, BS 6290-1984 and 440-1964.

ADVANTAGESTried and tested for over 20 years. High endurance at peak current.Long service life in stand-by operation. Corrosion-resistance pole bushing

FLOODED BATTERIES

SEC Industrial Battery Co.

SEC/DIN TYPE SP.GRAVITY

CAPACITY DATE

1.240

SEC Industrial Battery Co.SEC/DIN TYPE SP.GRAVITY

CAPACITYDATE

1.240

SEC Industrial Battery Co.

SEC/DIN TYPE SP.GRAVITY

CAPACITY DATE

1.240