22
SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Embed Size (px)

Citation preview

Page 1: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

SEAP Monitoring and developing

indicatorsJoe Hayden

Energy Engineer

Page 2: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Codema – Dublin’s Energy Agency

Founded in 1997 on the initiative of Dublin City Council with support from the European Commission

Acts as the sustainable energy adviser to Dublin City Council and since Jan 2009 to Fingal and South Dublin County Councils

Page 3: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer
Page 4: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Codema – Our experience

Page 5: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

The SECURE Project

Four action plans developed: Dublin, Ireland Malmo, Sweden Hillerod, Denmark Tallinn, Estonia

Page 6: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

The Covenant of Mayors

Codema have been involved with the COM from the beginning

Participated in the development of the COM SEAP development

Submitted first SEAP in 2010

Page 7: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

The Covenant of Mayors

Page 8: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

What have we learned?

Its as complex as you make it

Many approaches and many solutions

Just make a start, then improve

Page 9: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Covenant of Mayors: Step 3

Page 10: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Progress in Accuracy: Residential Sector

Sustainable Energy Action Plan Baseline Emissions Inventory:

2006 Baseline Year

“Sample” Dwelling used

Estimated U-values &

EfficiencyMonitoring Emissions Inventory:

2011 Baseline Year

SEAI National BER Research

Tool

Actual figures for approx.

26% households in Dublin

City

Includes detailed data on

Dublin City households

Page 11: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Results: Dublin City Residential Sector

Page 12: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Results: Dublin City Residential Sector

Page 13: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Results: Dublin City Residential Sector

Page 14: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Results: Dublin City Residential Sector

Solar 4 GWh

Biomass 3.5 GWh

Heatpump 2.8 GWh

Page 15: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Results: Dublin City Residential Sector

Baseline Final Energy Usage (2006): 5.9 TWh, emitting 1,723,807 t CO2

Monitoring Final Energy Usage (2011): 4.5 TWh, emitting 1,004,643 t CO2

Energy Savings (2006-2011): 1.4 TWh, equal to 23% reduction

Carbon Emissions Savings (2006-2011): 719,164 t CO2, equal to 42% reduction

Page 16: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Sample Indicator

Page 17: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

The SEAP & Monitoring

Page 18: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

What makes a good Indicator?

1. Is from a reliable data source

2. Updated on a regular basis

Questions to ask: Can you get the information now if

you need it? Will it be published again next year

or is it a one off?

Page 19: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

COM Indicator examples

Page 20: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Data management in the LA

survey information for 132 public buildings

over 1644 electricity accounts

Over 432 gas accounts

Page 21: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

Data management in the LA

Each site has an ID number connected to its MPRN(s) + GPRN(s) + survey data + DEC data + energy saving projects + etc...

Page 22: SEAP Monitoring and developing indicators Joe Hayden Energy Engineer

LEAP Indicator 1