Supplier: Supplier Address: Sec�on 1 - Iden�fica�on Product Iden�fier: Transmission System Cleaner Intended Use Industrial Lubricant for use in enclosed systems. Uses To Avoid Applica�ons that generate oil mists in air. MAXX Solutions 4243 Gatecrest, Suite 103, San Antonio TX 78217 Supplier Phone: 210-368-9248 Emergency Phone & Hours: 210-688-4966 24 hrs, 7 days/week Sec�on 2 - Hazard Iden�fica�on Signal Word: DANGER Other than flammability, no specific data exists for this mixture. Hazard classifica�ons are calculated based on component informa�on, according to GHS protocols for the relevant hazard. Eye damage/irrita�on (Category 2B), Aspira�on Hazard (Category 1), Skin Corrosion/Irrita�on (Category 3), Hazard Statements based on component informa�on: HAZARDS: Eye contact causes eye irrita�on. May be fatal if swallowed and enters airways. Skin contact causes mild skin irrita�on. Precau�ons: Do not handle un�l all safety instruc�ons are understood. Avoid breathing fumes or mist. Avoid skin contact. Wear protec�ve clothing, gloves, and eye protec�on before handling. Use only with adequate ven�la�on. Other Hazards Not Resul�ng In Classifica�on: May be hazardous to soil dwelling organisms. Summary: Read en�re SDS prior to use. Observe all precau�ons. Use engineering controls to minimize human exposure to workplace chemicals. Substance Or Mixture Mixture Hazard Classifica�ons: Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6 PICTOGRAMS: 4243 Gatecrest, Suite 103, San Antonio TX 78217 (210) 368-9248

SDS transmission system cleaner...Avoid spraying water jet on burning hydrocarbon liquids as this may spread the fire. Use dry chemical or foam ex nguishing media. Specific Fire

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • Supplier:

    Supplier Address:

    Sec�on 1 - Iden�fica�on Product Iden�fier: Transmission System Cleaner

    Intended Use Industrial Lubricant for use in enclosed systems.

    Uses To Avoid Applica�ons that generate oil mists in air.

    MAXX Solutions

    4243 Gatecrest, Suite 103, San Antonio TX 78217

    Supplier Phone: 210-368-9248

    Emergency Phone & Hours: 210-688-4966 24 hrs, 7 days/week

    Sec�on 2 - Hazard Iden�fica�on Signal Word: DANGER Other than flammability, no specific data exists forthis mixture. Hazard classifica�ons are calculatedbased on component informa�on, according to GHSprotocols for the relevant hazard.

    Eye damage/irrita�on (Category 2B), Aspira�on Hazard (Category 1), Skin Corrosion/Irrita�on (Category 3),

    Hazard Statements based on component informa�on:HAZARDS: Eye contact causes eye irrita�on. May be fatal if swallowed and enters airways. Skin contact causes mild skinirrita�on.

    Precau�ons:Do not handle un�l all safety instruc�ons are understood. Avoid breathing fumes or mist. Avoid skin contact. Wear protec�veclothing, gloves, and eye protec�on before handling. Use only with adequate ven�la�on.

    Other Hazards Not Resul�ng In Classifica�on:May be hazardous to soil dwelling organisms.

    Summary: Read en�re SDS prior to use. Observe all precau�ons. Use engineering controls to minimize human exposure toworkplace chemicals.

    Substance Or Mixture MixtureHazard Classifica�ons:

    Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6

    PICTOGRAMS:

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

  • Sec�on 4 - First Aid Measures:

    IF SWALLOWED: Get immediate medical a�en�on. Call poison control center.

    IF INHALED: Remove affected person to fresh air and make comfortable for breathing. Get immediate medical a�en�on.

    IF IN EYES: Remove contact lenses and rinse eyes with cool water. Get immediate medical a�en�on.

    IF ON SKIN: Rinse affected area with cool water. Get immediate medical a�en�on.

    IF ON CLOTHES: Do not allow skin contact with contaminated clothing. Remove contaminated clothing and wash before re-use.

    IF EXPOSED: Contact physician if you feel unwell.

    First responders should wear clothing appropriate for industrial exposure in accordance with local codes. At a minimum, all exposedskin should be covered, and latex gloves and eye protec�on mee�ng ANSI Z87 or CSA Z94.3 should be worn. First responders shouldavoid contact with spilled material. Spills of this material present a slip hazard. If smoke, fumes, or airborne mist is present, firstresponders should use organics respirator or self contained breathing apparatus.

    Most Important Symptoms ACUTE: Respiratory effects, vision effects. DELAYED: Dermatological effects.

    Indica�on of ImmediateMedical A�en�on

    Difficulty breathing, dizziness, extreme drowsiness, eye irrita�on, loss of vision, skin rash.

    Transmission System CleanerPage 2

    Sec�on 3 - Composi�on / Informa�on on Ingredients

    HYDROTREATED PARAFFINIC DISTILLATE

    IMIDAZOLINE COMPLEX

    TALLOW AMINE MIXTURE

    TRIPROPYLENEGLYCOL MONOETHER

    64742-65-0

    68140-98-7

    61791-44-4

    25498-49-1

    60 - 100

    5 - 15

    1 - 5

    1 - 5

    Exact percentages and componentiden��es are being witheld as tradesecrets. Occupa�onal Exposure Levels,Toxicity, and Ecological informa�on oncomponents is shown in Sec�ons 8, 11,and 12 below. Users should read andunderstand the en�re SDS. More specificinforma�on on components will bereleased to medical professionals in caseof emergency.

    Component CAS Number % Range

    Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

  • Sec�on 5 - Fire Figh�ng Measures:

    AppropriateEx�nguishing Media

    Avoid spraying water jet on burning hydrocarbon liquids as this may spread the fire. Use dry chemicalor foam ex�nguishing media.

    Specific Fire Hazards Fire fighters must be protected from smoke with self contained breathing apparatus. Heavy smoke mayobscure vision. Smoke may contain oxides of carbon, nitrogen, sulfur, and chlorine.

    Special Protec�ve Ac�ons Use water spray to cool exposed containers.

    Sec�on 6- Accidental Release Measures:Personal Precau�onsSpills present a slip hazard. Ex�nguish/disconnect possible sources of igni�on near spill. Ensure adequate ven�la�on of fumes fromaffected area. Remove unneccesary personnel from area around spill. Prior to cleaning up, don protec�ve gear including chemicaland hydrocarbon resistant outer layer, latex or rubber gloves, rubber boots, and eye protec�on. Emergency responders should wearchemical and hydrocarbon resistant gear.

    Environmental Precau�onsSmall spills may be wiped up with rags. For spills >10 litres- if possible to safely do so, contain the spilled material usingdiatomaceous earth and/or absorbent pads. Dike drains and prevent material from entering sewers, ditches, drains, or watercourses. Place absorbed material into sealed storage containers and consult an environmental expert for proper disposal measures.Immediately report any discharges that escape containment to the local environmental authority or fire department.

    Methods for Cleaning UpAbsorp�on with diatomaceous earth and/or absorbent pads is best. Do not use vacuum. Do not wash hydrocarbon or chemical spillsaway into sewers or drains. Use proper disposal methods for spent absorbents and contaminated rags or clothing.

    Sec�on 7- Storage and Handling:Precau�ons for HandlingRead and understand en�re Safety Data Sheet prior to handling. Wear all appropriate protec�ve gear prior to handling. Do not allowuntrained personnel to handle this product. Handle with care to avoid spillage.

    Methods for Safe StorageStore only in original containers. Store containers indoors away from heat and flames. Store in secure loca�on with goodven�la�on. Keep container sealed when not transferring product. Protect from rain and extreme cold. Avoid storage ofhydrocarbons near strong mineral acids or materials marked 'Oxidizer'.

    Transmission System Cleaner

    Page 3Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6

    Flash Point >93C

    HazardousDecomposi�on Products

    Byproducts of combus�on include carbon dioxide, carbon monoxide, oxides of sulfur, oxides ofnitrogen, and heavy, acrid smoke.

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

  • Page 4

    Sec�on 9- Physical Proper�es:

    Appearance Clear to Hazy Liquid Upper Explosive Limit Not DeterminedOdor Low Indescript Lower Explosive Limit Not Determined

    Odor Threshold No Data Available Vapour Pressure NegligiblepH N/A oil based Vapour Density >1 (air=1)

    Mel�ng Point Liquid under intended use condi�ons Rela�ve Density 0.8-0.9 kg/l 60CFreezing Point 0 to -20 Solubility Hydrocarbons, Alcohols

    Ini�al Boiling Point No Data Available Par��on Coefficient Log KOW > 4 (mineral oil data)Boiling Range 313C - 432C Auto Igni�on Temp Not Determined

    Flash Point >93C Decomposi�on Temp Not DeterminedEvapora�on Rate

  • Sec�on 10- Physical Proper�es:

    Possibly Hazardous Reac�ons None known.

    Reac�vity May react violently if combined with strong oxidizers and heat.

    Chemical Stability Stable under recommended storage condi�ons.

    Condi�ons to Avoid Keep away from fire, sparks, and other sources of igni�on.

    Incompa�ble Materials Strong acids and materials marked 'Oxidizer'.

    Hazardous Decomposi�onProducts

    Byproducts of combus�on include carbon dioxide, carbon monoxide, oxides of sulfur, oxides ofnitrogen, and heavy, acrid smoke.

    Sec�on 11- Toxicological Informa�on:

    Likely Routes ofExposure

    Dermal and/or Eye exposure from handling. Intended use of product is within enclosed systems which do not generatemist in air.

    Symptoms of Exposure:

    Inges�on Inges�on of minimal amounts, e.g. failure to wash hands before ea�ng/smoking, is unlikely to cause symptoms.Swallowing of liquid product may cause vomi�ng and nausea.

    Inhala�on No symptoms are expected under intended use condi�ons. Exposure to concentrated fumes may cause transienthypoxia.

    Dermal/Eye Minimally irrita�ng by dermal exposure. Eye exposure may cause transient s�nging and blurred vision.

    Immediate orDelayed Effects

    Not expected from exposure to mineral or vegetable oils.

    Interac�ve Effects None Known

    Numerical Measures of Toxicity - components (all LD/LC/EC 50 values shown below are based on animal or fish data) at max range value sec�on 3.

    Page 5

    HYDROTREATED PARAFFINIC DISTILLATE: Non Hazardous; IMIDAZOLINE COMPLEX: LD50 5001 mg/Kg; TALLOW AMINE MIXTURE:Non Hazardous; TRIPROPYLENEGLYCOL MONOETHER: LD50 3200 mg/Kg

    Acute OralToxicity:

    Acute SkinToxicity:

    HYDROTREATED PARAFFINIC DISTILLATE: Non Hazardous; IMIDAZOLINE COMPLEX: Non Hazardous; TALLOW AMINE MIXTURE:Non Hazardous; TRIPROPYLENEGLYCOL MONOETHER: Non Hazardous

    Acute ToxicityInhala�on

    HYDROTREATED PARAFFINIC DISTILLATE: Non Hazardous; IMIDAZOLINE COMPLEX: No Data Available; TALLOW AMINE MIXTURE:No Data Available; TRIPROPYLENEGLYCOL MONOETHER: Non Hazardous

    Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6

    Transmission System Cleaner

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

  • Skin Corrosion: HYDROTREATED PARAFFINIC DISTILLATE: Non Irrita�ng; IMIDAZOLINE COMPLEX: Non Irrita�ng; TALLOW AMINE MIXTURE: Cat 2Irritant; TRIPROPYLENEGLYCOL MONOETHER: No Data Available

    Eye Corrosion: HYDROTREATED PARAFFINIC DISTILLATE: Non-Categorized, Suspected Eye Irritant; IMIDAZOLINE COMPLEX: Non-Categorized,Suspected Eye Irritant; TALLOW AMINE MIXTURE: Cat 2A Serious Irrita�on; TRIPROPYLENEGLYCOL MONOETHER:Non-Categorized, Suspected Eye Irritant

    RespiratorySensi�za�on:

    HYDROTREATED PARAFFINIC DISTILLATE: Non Sensi�zing; IMIDAZOLINE COMPLEX: Non Sensi�zing; TALLOW AMINE MIXTURE:No Data Available; TRIPROPYLENEGLYCOL MONOETHER: Non Sensi�zing

    SkinSensi�za�on:

    HYDROTREATED PARAFFINIC DISTILLATE: Non Sensi�zing; IMIDAZOLINE COMPLEX: Non Sensi�zing; TALLOW AMINE MIXTURE:No Data Available; TRIPROPYLENEGLYCOL MONOETHER: No Data Available

    Germ CellMutagenicity:

    HYDROTREATED PARAFFINIC DISTILLATE: No Hazard; IMIDAZOLINE COMPLEX: No Hazard; TALLOW AMINE MIXTURE: No DataAvailable; TRIPROPYLENEGLYCOL MONOETHER: No Data Available

    Carcinogen: HYDROTREATED PARAFFINIC DISTILLATE: No Hazard; IMIDAZOLINE COMPLEX: No Data Available; TALLOW AMINE MIXTURE: NoHazard; TRIPROPYLENEGLYCOL MONOETHER: No Hazard

    Reproduc�veEffects:

    HYDROTREATED PARAFFINIC DISTILLATE: No Hazard; IMIDAZOLINE COMPLEX: No Data Available; TALLOW AMINE MIXTURE: NoData Available; TRIPROPYLENEGLYCOL MONOETHER: No Data Available

    Page 6

    Sec�on 11- Toxicological Informa�on: (con�nued)

    Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6

    Transmission System Cleaner

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

  • Other Informa�on No Other Informa�on Available.

    Page 7

    Target Organ 1Exposure:

    HYDROTREATED PARAFFINIC DISTILLATE: No Hazard; IMIDAZOLINE COMPLEX: No Hazard; TALLOW AMINE MIXTURE: No DataAvailable; TRIPROPYLENEGLYCOL MONOETHER: No Data Available

    Target OrganMul�pleExposure:

    HYDROTREATED PARAFFINIC DISTILLATE: No Hazard; IMIDAZOLINE COMPLEX: No Data Available; TALLOW AMINE MIXTURE: NoData Available; TRIPROPYLENEGLYCOL MONOETHER: No Data Available

    Aspira�onHazard:

    HYDROTREATED PARAFFINIC DISTILLATE: Cat 1 Aspira�on Hazard; IMIDAZOLINE COMPLEX: No Hazard; TALLOW AMINEMIXTURE: No Data Available; TRIPROPYLENEGLYCOL MONOETHER: No Hazard

    Sec�on 11- Toxicological Informa�on: (con�nued)

    Sec�on 12- Ecological Informa�on:

    Ecological Summary Hydrocarbon mineral oils, and non-petroleum oils, have low toxicity and are inherently biodegradable. See specificinforma�on below regarding aqua�c toxicity data on components.

    Bioaccumula�on Hydrocarbon mineral oils, and non-petroleum oils, are inherently biodegradable and have low bioaccumula�on poten�al.Specific informa�on on components is shown below.

    Persistance &Degradability

    Hydrocarbon mineral oils, and non-petroleum oils, are inherently biodegradable and are not persistant. OECD 301 valuesrange from 50% to 95% in 28 days.

    Waste TreatmentEffects

    Product residues are not expected to enter publicly operated treatment works. No nega�ve effects of this mixture areknown.

    Soil Mobility Mineral oils have been shown to adhere strongly to soil. Mobility is expected to be low.

    Other AdverseEffects

    None Known

    Toxicity to aqua�c organisms, component informa�on:

    Aqua�cToxicity,Acute:

    HYDROTREATED PARAFFINIC DISTILLATE: Non Toxic; IMIDAZOLINE COMPLEX: Non Toxic; TALLOW AMINE MIXTURE: No DataAvailable; TRIPROPYLENEGLYCOL MONOETHER: Non Toxic

    Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6

    Transmission System Cleaner

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

  • Sec�on 13- Disposal Considera�ons:Disposal Containers & Methods Unused material is not a RCRA hazardous waste. Mixture with other wastes may cause

    classifica�on as hazardous waste. Users must determine compliance with local, state, and federalregula�ons for proper classifica�on and disposal of used oils and mixtures thereof. Suitablecontainers include steel and polyethylene drums and totes, for containment of used oil. Secondarycontainment is advised. Containers should be kept sealed and protected from rain and exposure.

    Physical Chemical Proper�esAffec�ng Disposal

    Changes in physical and chemical proper�es during use, such as contamina�on with lead, zinc, orother metals, may affect classifica�on for disposal. Used oils should be tested to determine metalscontent and applicable local, state, and federal regula�ons governing disposal of such fluids.

    Improper Disposal Discharging of oily wastes into any sewer , watercourse, or unregulated drain is discouraged asimproper and may result in fines, penal�es, cleanup costs, and criminal liabili�tes for responsiblepar�es.

    Precau�ons for Landfill Oily liquid should not be disposed in a landfill. Disposal of oily absorbents, rags, or other items intoa landfill should only be done with proper permission from local, state, and federal authori�es.

    HYDROTREATED PARAFFINIC DISTILLATE: No Chronic Aqua�c Toxicity; IMIDAZOLINE COMPLEX: No Chronic Aqua�c Toxicity; TALLOWAMINE MIXTURE: No Data Available; TRIPROPYLENEGLYCOL MONOETHER: No Chronic Aqua�c Toxicity

    Aqua�cToxicity,LongTerm:

    Ozone: This product neither contains, nor was manufactured with a Class lor Class ll ODS as defined by 40 CFR 82, Subpt. A, App.A + 8.

    Sec�on 14- Transport Informa�on:

    Proper Shipping Name Not Regulated UN/ID/NA Number: NA nonregulated

    Transport Hazard Class NA Packing Group NA

    Special Precau�ons None

    US DOT 49 CFR Parts 171-180:

    Labels: NA ERGCode NA

    Marine Pollutant: No

    IATA-DGR

    UN/ID Number NA nonregulatedIATA Proper Shipping Name Not Regulated

    IATA Class NA IATA Labels NAIATA Packing Group: NA

    IMDG-CODE

    IMDG Proper Shipping Name Not Regulated

    IMDG UN/ID Number NA nonregulated IMDG Shipping Class NA IMDG Packing Group NA

    IMDG Labels NA IMDG Marine Pollutant: No

    MARPOL 73/78 Annex II

    MARPOL Not available for sale in bulk marine shipments

    Page 8Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6Transmission System Cleaner

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

  • Page 9

    All Components are properly registered

    CA Prop 65 No Known Hazard or Not Listed

    Other Regula�ons

    TSCA Status:

    REACH : All components are included in the REACH registry.

    Canada WHMISHazard Class:

    No Known Hazard or Not Listed

    Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6

    Sec�on 15- Regulatory Informa�on:

    SARA 313 EHS No Known Hazard or Not Listed

    OSHA 1910.1200 Hazardous Chemical: Hazards are classified as reported in Sec�on 2 above.

    No Known Hazard or Not ListedSARA 302 EHS

    Transmission System Cleaner

    Reac�vity No Acute No Chronic No Fire No Pressure NoSARA 311/312

    US State Lists & Regula�ons:

    No Known Hazard or Not ListedIL RTK:

    No Known Hazard or Not ListedMA RTK:

    No Known Hazard or Not ListedMN RTK:

    No Known Hazard or Not ListedNJ RTK:

    No Known Hazard or Not ListedNY RTK:

    No Known Hazard or Not ListedPA RTK:

    No Known Hazard or Not ListedRI RTK:

    No Known Hazard or Not ListedSafe Drinking WaterAct:

    US State Right To Know Informa�on:

    Interna�onal Chemical Inventory Status:

    Australia AICS Canada DSL

    Canada NDSLChina IECSC Europe EINECS

    Japan ENCS Korea ECL

    Europe ELINCS New Zealand InvPhillipines PICCS

    NOTE: Informa�on provided in this sec�on reflects the best available informa�on from suppliers ofcomponents used to manufacture this mixture, as of the date of this revision shown below.

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248

  • Sec�on 16- Other Informa�on:

    Revision Date 6/13/2019

    Reasons For Revision New Informa�on From Supplier GHS

    Sec 16 Other Info This Safety Data Sheet was prepared in good faith from the most recent informa�on available, inaccordance with ST/SG/AC.10/30/Rev.6. HOWEVER, NO WARRANTY OF MERCHANTABILITY, FITNESSFOR ANY PARTICULAR PURPOSE, OR ANY OTHER WARRANTY IS EXPRESSED OR IS TO BE IMPLIEDREGARDING THE ACCURACY OR COMPLETENESS OF THE INFORMATION PROVIDED ABOVE, THE RESULTSTO BE OBTAINED FROM THE USE OF THIS INFORMATION OR THE PRODUCT, THE SAFETY OF THISPRODUCT, OR THE HAZARDS RELATED TO ITS USE. No responsibility is assumed for any damage or injuryresul�ng from abnormal use or from any failure to adhere to recommended prac�ces. The informa�onprovided above, and the product, are furnished on the condi�on that the person receiving them shallmake their own determina�on as to the suitability of the product for their par�cular purpose and on thecondi�on that they assume the risk of their use.

    Page 10

    Transmission System Cleaner

    Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6

    4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248