SDLC Y Cable
1
SDLC Y CableThe SDLC Y cable was developed for use in traffic cabinets that utilize an SDLC bus but don’t have enough SDLC connectors to add any additional devices. Inserting one of these cables between an existing SDLC cable and SDLC device provides you with an extra connector for adding devices to the SDLC bus.
Features ˿ Cable forks at one end, for a total of
three connectors. Two male connectors One female connector
˿ Can be used to provide an extra SDLC connector in a NEMA TS-2 cabinet, for adding an additional device to the SDLC bus.
˿ Cable is NEMA-compliant: Cable rated to 300V RMS and 105°C Contacts at least 15 millionths of
an inch gold plated
Connectors feature latching blocks ˿ Main cable is four feet in length;
shorter arm is eight inches in length.
WX-500-0327
Cable length 4 ft.
Male connector
Male connector
Female connector
Any SDLC device
Any SDLC device
Any SDLC device
2 www.wavetronix.com
SDLC Y Cable
Technical Specifications
Cable ˿ Main cable length: 4 ft. (1.2 m) ˿ Shorter cable arm length: 8 in. (20.3 cm) ˿ Ambient operating temperature: -30°C to 105°C ˿ 4 pair 22 AWG stranded tinned copper conductors ˿ Overall foil shielded with drain ˿ PVC jacket and insulation ˿ Complies with the following NEMA specifications:
Rated to 300V RMS Rated to 105°C
Connectors ˿ Three SDLC connectors:
Two male One female
˿ Comply with the following NEMA specifications: Connectors feature latching blocks Contacts at least 15 millionths of an inch gold plated
Ordering InformationSDLC Y cable310-0413
Wavetronix78 East 1700 SouthProvo, UT [email protected]
SDLC Y Cable
3
SDLC Y Cable Bid Specification 1.0 General. This item shall govern the purchase of a forked (Y) SDLC cable equivalent to the Wavetronix SDLC Y cable (YC).
2.0 Cable. The YC shall consist of a cable 4 feet (1.2 meters) in length with a branching arm that is 8 inches (20.3 centimeters) in length.
The YC shall have an ambient operating temperature of -30°C to 105°C.
The conductors in the YC shall consist of four pairs of 22 AWG stranded tinned copper conductors. The YC shall be foil shielded and include a drain. The YC shall have a PVC jacket and insulation.
The YC shall comply with the following NEMA specifications: it shall be rated to 300V RMS, and to 105°C.
3.0 Connectors. The YC shall have three SDLC connectors, two male and one female.
The YC’s connectors shall comply with the following NEMA specifications: they shall feature latching blocks, and the contacts shall be at least 15 millionths of an inch gold plated.