SDLC Y Cable 1 SDLC Y Cable The SDLC Y cable was developed for use in traffic cabinets that utilize an SDLC bus but don’t have enough SDLC connectors to add any additional devices. Inserting one of these cables between an existing SDLC cable and SDLC device provides you with an extra connector for adding devices to the SDLC bus. Features ˿ Cable forks at one end, for a total of three connectors. Two male connectors One female connector ˿ Can be used to provide an extra SDLC connector in a NEMA TS-2 cabinet, for adding an additional device to the SDLC bus. ˿ Cable is NEMA-compliant: Cable rated to 300V RMS and 105°C Contacts at least 15 millionths of an inch gold plated Connectors feature latching blocks ˿ Main cable is four feet in length; shorter arm is eight inches in length. WX-500-0327 Cable length 4 ft. Male connector Male connector Female connector Any SDLC device Any SDLC device Any SDLC device

SDLC Y Cable - d1upf2v1quehpe.cloudfront.net Cable a 1 SDLC Y Cable The SDLC Y cable was developed for use in traffic cabinets that utilize an SDLC bus but don’t have enough SDLC

Embed Size (px)

Citation preview

Page 1: SDLC Y Cable - d1upf2v1quehpe.cloudfront.net Cable a 1 SDLC Y Cable The SDLC Y cable was developed for use in traffic cabinets that utilize an SDLC bus but don’t have enough SDLC

SDLC Y Cable

1

SDLC Y CableThe SDLC Y cable was developed for use in traffic cabinets that utilize an SDLC bus but don’t have enough SDLC connectors to add any additional devices. Inserting one of these cables between an existing SDLC cable and SDLC device provides you with an extra connector for adding devices to the SDLC bus.

Features ˿ Cable forks at one end, for a total of

three connectors. Two male connectors One female connector

˿ Can be used to provide an extra SDLC connector in a NEMA TS-2 cabinet, for adding an additional device to the SDLC bus.

˿ Cable is NEMA-compliant: Cable rated to 300V RMS and 105°C Contacts at least 15 millionths of

an inch gold plated

Connectors feature latching blocks ˿ Main cable is four feet in length;

shorter arm is eight inches in length.

WX-500-0327

Cable length 4 ft.

Male connector

Male connector

Female connector

Any SDLC device

Any SDLC device

Any SDLC device

Page 2: SDLC Y Cable - d1upf2v1quehpe.cloudfront.net Cable a 1 SDLC Y Cable The SDLC Y cable was developed for use in traffic cabinets that utilize an SDLC bus but don’t have enough SDLC

2 www.wavetronix.com

SDLC Y Cable

Technical Specifications

Cable ˿ Main cable length: 4 ft. (1.2 m) ˿ Shorter cable arm length: 8 in. (20.3 cm) ˿ Ambient operating temperature: -30°C to 105°C ˿ 4 pair 22 AWG stranded tinned copper conductors ˿ Overall foil shielded with drain ˿ PVC jacket and insulation ˿ Complies with the following NEMA specifications:

Rated to 300V RMS Rated to 105°C

Connectors ˿ Three SDLC connectors:

Two male One female

˿ Comply with the following NEMA specifications: Connectors feature latching blocks Contacts at least 15 millionths of an inch gold plated

Ordering InformationSDLC Y cable310-0413

Wavetronix78 East 1700 SouthProvo, UT [email protected]

Page 3: SDLC Y Cable - d1upf2v1quehpe.cloudfront.net Cable a 1 SDLC Y Cable The SDLC Y cable was developed for use in traffic cabinets that utilize an SDLC bus but don’t have enough SDLC

SDLC Y Cable

3

SDLC Y Cable Bid Specification 1.0 General. This item shall govern the purchase of a forked (Y) SDLC cable equivalent to the Wavetronix SDLC Y cable (YC).

2.0 Cable. The YC shall consist of a cable 4 feet (1.2 meters) in length with a branching arm that is 8 inches (20.3 centimeters) in length.

The YC shall have an ambient operating temperature of -30°C to 105°C.

The conductors in the YC shall consist of four pairs of 22 AWG stranded tinned copper conductors. The YC shall be foil shielded and include a drain. The YC shall have a PVC jacket and insulation.

The YC shall comply with the following NEMA specifications: it shall be rated to 300V RMS, and to 105°C.

3.0 Connectors. The YC shall have three SDLC connectors, two male and one female.

The YC’s connectors shall comply with the following NEMA specifications: they shall feature latching blocks, and the contacts shall be at least 15 millionths of an inch gold plated.