10
ScopeDome USB Card ver 2.0 ScopeDome.com RELAY 4 NO NC COM RELAY 3 NO NC COM RELAY 2 NO NC COM RELAY 1 NO NC COM COM CW CCW PE L N L N PE DOME INVERTER L N PE L N PE CCD SCOPE FAN B(-) A(+) Rs485 +U GND Analog Input SW GND Free Input SW GND Scope AtHome SW GND Obser. Safe Dome Encoder OS +V GND Dome At Home SO +V GND SW GND Cloud Sensor +12V GND DC IN +12V +5V GND DC OUTPUT GND USB FUSE 8A B(-) A(+) OUT. 230V UPS 230V LINE 230V PE L N PE L N PE L N 230VAC OUTPUT 230VAC OUTPUT 230VAC OUTPUT Pins - MAIN PART

ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

Embed Size (px)

Citation preview

Page 1: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

RELAY 4

NO

NC

CO

M

RELAY 3

NO

NC

CO

M

RELAY 2

NO

NC

CO

M

RELAY 1

NO

NC

CO

M

CO

M

CW

CC

W

PEL N L NPE

DOME INVERTER

L NPE L NPE

CCD SCOPE FAN

B(-)

A(+

)

Rs485

+U

GN

D

AnalogInput

SW

GN

D

FreeInput

SW

GN

D

ScopeAtHome

SW

GN

D

Obser.Safe

DomeEncoder

OS

+V

GN

D

DomeAt Home

SO

+V

GN

D

SW

GN

D

CloudSensor

+12V

GN

D

DC IN

+12V

+5V

GN

D

DC OUTPUT

GN

D

USB

FU

SE

8A

B(-)

A(+)

OU

T. 2

30V

UP

S 2

30V

LIN

E 2

30V

PE

L

N

PE

L

N

PE

L

N

230VACOUTPUT

230VACOUTPUT

230VACOUTPUT

Pins - MAIN PART

Page 2: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

+12V

GND

DC

IN

B(-)

A(+)

Rs4

85

UP

S 2

30V

PE

L

N

LIG

HT PE

L

N+

5V

CK

DA

TA

Higrometer

GN

D

SW

GN

D

RainSensor

Shutter 1Encoder

OS

+V

GN

D

SO

+V

GN

D

+U

GN

D

1W

GN

D

1W

GN

D

Shutter 2Encoder

AnalogInput

Temp.In

Temp.Out

So1

So2

CO

M

OP

EN

CLO

SE

PEL NSc1

SW

Sc2

GN

D

So1

SW

So2

GN

D

CO

M

PEL NSc1

SW

Sc2

GN

D

Shutter Inverter - 1

OP

EN

CLO

SE

Shutter Inverter - 2Close1Sensor

Close1LS

Open1Sensor

Open1LS

Close2Sensor

Close2LS

Open2Sensor

SW

GN

D

Open2LS

Pins - WIRELES SHUTTER CONTROL MODULE

Page 3: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

Pier

Dome Rotate

Base RingPier diameter: 50 cm

ShutterInverter

Open SensorLimit Switch

Dome Top

230VACMain Power

DomeEncoder

DomeTop Light

USB

PCComputer

MS Windows XP/Vista/7

ASCOMDomeDriver

DomeInverter

M

ShutterDrive370W/3PhaseDome Top

MDomeDrive240W/3Phase

Dome Top

4x0.25 mm 4x0.25 mm

3x0.25 mm4x0.5 mm

2x0.5 mm

4x0.5 mm

3x0.25 mm

3x0.5 mm

3x0.5 mm

3x0.25 mm

3x0.5 mm

on dome base wires line

from Pier to Base Ring

44

22

33

66 5

5

5 5

99

1111

88

1010

1313

1212

1212

11

- Low voltage wires- High voltage (230VAC) wires

- Plug And Play Connectors with wire number

- Dome Parts

- Main Power (230VAC)

- Power Contacts on basering

- Main power connector on dome rotate part

Drawing info

1 1

PLUG AND PLAY WIRING DIAGRAM

Home Sensor

SV008iC5-1F

Close SensorLimit Switch

Dome Front

SV008iC5-1F

4pin 4pin3pin 3pin 4pin 4pin3pin 3pin

UPSIN

OUT

7 73x0.5 mm

X X

3p

in3p

in2p

in2p

in

4pin 3pin 3pin2pin 2pin 2pin 2pin

12V

DC

UP

SB

AT

TE

RY

+-

3x0.5 mmX X 2x0.25 mm

2x5 mm

OU

T

IN

HIGRO RAIN

UPSIN

OUT

4pin2pin

3pin 3pin 3pin 3pin 3pin 3pin 3pin 3pin

3pin 3pin 2pin 2pin 2pin 2pin 2pin 2pinUSB

3p

in3p

in3p

in

2p

in

3pin

xx

3x0.5 mm

3x0.25 mm

77

3x0.5 mm

1.5m shielded USB cable

3x0.5 mm

POWER CONTROL

LIGHT

Page 4: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

32

5

MDomeDrive240W/3Phase

RELAY 4

NO

NC

CO

M

RELAY 3

NO

NC

CO

M

RELAY 2

NO

NC

CO

M

RELAY 1

NO

NC

CO

M

CO

M

CW

CC

W

PEL N L NPE

DOME INVERTER

L NPE L NPE

CCD SCOPE FAN

B(-)

A(+

)

Rs485

+U

GN

D

AnalogInput

SW

GN

D

FreeInput

SW

GN

D

ScopeAtHome

SW

GN

D

Obser.Safe

DomeEncoder

OS

+V

GN

D

DomeAt Home

SO

+V

GN

D

SW

GN

D

CloudSensor

+12V

GN

D

DC IN

+12V

+5V

GN

D

DC OUTPUT

GN

D

USB

FU

SE

8A

B(-)

A(+)

OU

T. 2

30V

UP

S 2

30V

LIN

E 2

30V

PE

L

N

PE

L

N

PE

L

N

SV008iE5-1F

PE

CM

P1

P2

WVU

L N

PE

LN

PE

LN

UPS230/230VAC

2200W

INP

UT

OU

TP

UT

DomeEncoder

DomeAtHomeSensor

WU V

PE

230VACOUTPUT

230VACOUTPUT

230VACOUTPUT

12VDCUPS

BATTERY

+ -

+-

UPS BATTERY

BO

LT

WO

OD

/ A

AG

CL

OU

D S

EN

SO

R

230VAC/3PhaseDOME MOTORINVERTER

230VACMAIN POWER

L NPE

DIAGRAM FOR BASERING AND PIER PART

230VACPOWER CONTACTS

L NPE

6

4

7

1

Page 5: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

+12V

GND

DC

IN

B(-)

A(+)

Rs4

85

UP

S 2

30V

PE

L

N

LIG

HT PE

L

N+

5V

CK

DA

TA

Higrometer

GN

D

SW

GN

D

RainSensor

Shutter 1Encoder

OS

+V

GN

D

SO

+V

GN

D

+U

GN

D

1W

GN

D

1W

GN

D

Shutter 2Encoder

AnalogInput

Temp.In

Temp.Out

So1

So2

CO

M

OP

EN

CLO

SE

PEL NSc1

SW

Sc2

GN

D

So1

SW

So2

GN

D

CO

M

PEL NSc1

SW

Sc2

GN

D

Shutter Inverter - 1

OP

EN

CLO

SE

Shutter Inverter - 2Close1Sensor

Close1LS

Open1Sensor

Open1LS

Close2Sensor

Close2LS

Open2Sensor

SW

GN

D

Open2LS

12VDCUPS

BATTERY

+ -

PE LN

PE LN

UP

S230/2

30V

AC

2200W

INPUT

OUTPUT

+-

UP

S B

AT

TE

RY

DIAGRAM FOR ROTATE PART

SV008iE5-1F

PE

CM

P1

P2

WVU

L N

230VAC/3PhaseSHUTTER MOTORINVERTER

MShutterDrive370W/3Phase

WU V

PE

230VACPOWER CONTACTS

LN PE

HIGROMETER

DA

TA

+5V

GN

D

CK

RAIN SENSOR T

HE

MR

MO

ME

TE

RIN

DO

ME

TH

EM

RM

OM

ET

ER

OU

TS

IDE

DO

ME

Close SensorLimit Switch

Dome Front

1 2

3 4

Open SensorLimit Switch

Dome Top

1 2

3 4

WH

ITE

BR

OW

N

WH

ITE

BR

OW

N

-

+12V

DomeTop Light

Dome Top

8 9 10

11

12

13

7

7

POWER CONTROL

LIGHT

Page 6: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

RELAY 4

NO

NC

CO

M

RELAY 3

NO

NC

CO

M

RELAY 2

NO

NC

CO

M

RELAY 1

NO

NC

CO

M

CO

M

CW

CC

W

PEL N L NPE

DOME INVERTER

L NPE L NPE

CCD SCOPE FAN

B(-)

A(+

)

Rs485

+U

GN

D

AnalogInput

SW

GN

D

FreeInput

SW

GN

D

ScopeAtHome

SW

GN

D

Obser.Safe

DomeEncoder

OS

+V

GN

D

DomeAt Home

SO

+V

GN

D

SW

GN

D

CloudSensor

+12V

GN

D

DC IN

+12V

+5V

GN

D

DC OUTPUT

GN

D

USB

FU

SE

8A

B(-)

A(+)

OU

T. 2

30V

UP

S 2

30V

LIN

E 2

30V

PE

L

N

PE

L

N

PE

L

N

Alternative Encoder and Home Sensor Connection

Page 7: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.comPower Over IP control for remote observatory

Aviosys IP POWER 9258 Wi-Fi Remote Power Switch - 4 Port

PCComputer

WiFi Router

WiFi Ip Power Switch

UPS2200W

ScopeDomeWirelessShutter ControlModule

Internet/Lan

230VAC

ScopeDomeUSB Cardver. 2.0

UPS2200W

UPS230VAC

Main Power230VAC

WiFi Lan Card

230VACfrom contacts on base ring

WiFi Ip Power Switch

UPS230VAC

Dome Rotate

Base Ring

Line230VAC

Page 8: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

RELAY 4

NO

NC

CO

M

RELAY 3

NO

NC

CO

M

RELAY 2

NO

NC

CO

M

RELAY 1

NO

NC

CO

M

CO

M

CW

CC

W

PEL N L NPE

DOME INVERTER

L NPE L NPE

CCD SCOPE FAN

B(-)

A(+

)

Rs485

+U

GN

D

AnalogInput

SW

GN

D

FreeInput

SW

GN

D

ScopeAtHome

SW

GN

D

Obser.Safe

DomeEncoder

OS

+V

GN

D

DomeAt Home

SO

+V

GN

D

SW

GN

D

CloudSensor

+12V

GN

D

DC IN

+12V

+5V

GN

D

DC OUTPUT

GN

D

USB

FU

SE

8A

B(-)

A(+)

OU

T. 2

30V

UP

S 2

30V

LIN

E 2

30V

PE

L

N

PE

L

N

PE

L

N

230VACPOWER CONTACTS

L NPE

Special power control for remote cold card reset

Page 9: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

12V DC Motor

- 12V

+ 1

2V

- Mo

tor

+M

oto

rC

om

CC

W

CW

L 2

30 V

AC

N 2

30 V

AC

ScopeDome CW/CCW

to 12V DC Relay Box

M

Battery

12VPower

+-

- 12V

+ 1

2V

- Mo

tor

+M

oto

r

Co

m

CC

W

CW

L 2

30 V

AC

N 2

30 V

AC

ScopeDome CW/CCW to 12V DC Relay Box

CO

M

CW

CC

W

PE LN

DOME INVERTER

ScopeDomeUSB Card

ver. 2.0

ScopeDome CW/CCW to 12V DC Relay Box

12V DC Motors and ScopeDome card

P1

230V

P2

230V

P11 P12

CW CCW

Com

CW

CC

W

L 2

30 V

AC

N 2

30 V

AC

- 12V

+ 1

2V

- Moto

r

+- M

oto

r

P21 P22

Page 10: ScopeDome USB Card v2.0 For Manual€¦ · ups battery +--+ ups battery bol twood / aag cloud sensor 230vac/3phase dome motor inverter 230vac main power l pe n diagram for basering

ScopeDome USB Card ver 2.0 ScopeDome.com

4

56

11

1213

Dome inverter connection Shutter inverter connection

L N U V W

CM

P1

P2

PE

INVERTER CONNECTION