ScopeDome.com | 2015 |Slupsk | Poland 1
sky observatory
ScopeDome Thermostate
ver. 3.0
ver 1.1
ScopeDome.com | 2015 |Slupsk | Poland 2
Howitworks
ScopeDome thermostat is a microprocessor control relay device,
along with software allowing to maintain a constant temperature on
the basis of its measurement with built-in or external thermometer.
The measurement results are transferred via USB to a PC running
under Windows. In addition, together with the computer, the system
can work as PID controller, allowing for very precise maintaining the
desired temperature or simply control switching on and off of the
relay. Outputs system allows the use of heaters or other devices
powered by 12V DC or 230VAC. All thermostat settings are stored in
EPROM. The control software allows you to connect up to 256
thermostats for one computer.
S - S.IN S + USB
RELAY BIMETAL 230VAC 12/230V 12V DC
NC COM NO Bi.2 Bi.1 N2 N1 L1 L2 INP. Dc2 GND2 GND1 Dc1
+-
EXT. Thermometer
83.0 mm
59.0
mm
ScopeDome Thermostate
77.8 mm
Basicparameters- Maximum load of relay contacts must not exceed
10A.
- The main circuit board brought out all relay (NC /
COM / NO).
- The system has a built-in USB port optoelectronic
separation.
- 12V DC power input is protected against
reversed voltage polarity.
- Consumes a maximum of 50 mA (when the relay
is 'on' state).
Thethermostatsystemcanoperateinthreemodes
1. Autonomous (without connection to PC):
- switch on/off temperatures of the heaters are
set using the potentiometers
- by default the temperature for comparison is
read from an internal thermometer
- if you want to use the thermostat based on the
outside thermometer temperature, you can
program such operating mode when connected
to a computer through a USB port
- with a PC, you can also change the temperature
ranges using potentiometers
2. PC Control:
- in this mode, switching on/off temperatures of
the heaters are determined by the software
3. PC Manual:
- this mode is for manual control a status of the
relay
4.PID Heater:
- after calibration allows to maintain the
temperature with an accuracy of 0.05 Celsius
53.5
mm
PCBdimensions
ScopeDome.com | 2015 |Slupsk | Poland 3
Inputs,outputsandcontrolelements
USB portoutside thermometer
input (Ic2 bus)
switch on
the temperature relay
potentiometer
switch offthe temperature relay potentiometer
programmer port
main fuse 15A
LED current relay state
indicators
COM/NC/NO
relay output
Main power
12V DC
12V DC / 230 VAC
heater switch
230 VAC power
for Heateradditiona thermistor input
(protecting the heater)
internal
thermometer
ScopeDome.com | 2015 |Slupsk | Poland 4
S - S.IN S + USB
RELAY BIMETAL 230VAC 12/230V 12V DC
NC COM NO Bi.2 Bi.1 N2 N1 L1 L2 INP. Dc2 GND2 GND1 Dc1
EXT. Thermometer
ScopeDome Thermostate
Wiringdiagramof12VDCheater
12V DC Heater
Bi
+-
+-12V DC 10A
PCB and Heater main power
S - S.IN S + USB
RELAY BIMETAL 230VAC 12/230V 12V DC
NC COM NO Bi.2 Bi.1 N2 N1 L1 L2 INP. Dc2 GND2 GND1 Dc1
EXT. Thermometer
ScopeDome Thermostate
Wiringdiagramof230VACheater
230V AC Heater
Bi
+-
+-12V DC 50 mA
PCB only power
ShortCut
ShortCut
N L
230V AC Heater power
ConnectinganexternalScopeDomethermometer(PIDmode)
S - S.IN S +
EXT. Thermometer
Bro
wn
Wh
ite
BIMETAL
Bi.2 Bi.1
Optionaljumperinsteadofbimetalfortheheateroverheatingprotection
ScopeDome.com | 2015 |Slupsk | Poland 5
PCBscheme
5V
IN
GND
OUT
IC178M05
GND
T1BC847
D2
L4148
12V
GND
12V
R1
4.7k
C2
220uF/25V
C1
470uF/25VC3
100nF/25V
C4
100nF/25V
VR2?
PR1
10k
PD
.5 (
T1
)9
PD
.6 (
AIN
0)
10
PD
.7 (
AIN
1)
11
PB
.0 (
ICP
1)
12
PB
.4 (
MIS
O)
16
PB
.3 (
MO
SI)
15
PB
.2 (
SS
/OC
1B
)1
4
PB
.1 (
OC
1A
)1
3
(RE
SE
T)
PC
.62
9
(RX
D)
PD
.03
0
(TX
D)
PD
.13
1
(IN
T0
) P
D.2
32
(AD
C5
) P
C.5
28
PD.3 (INT1)1
PD.4 (XCK)2
VCC4
GND3
PB.6 (XTAL1)7
PB.7 (XTAL2)8
(AD
C4
) P
C.4
27
(AD
C3
) P
C.3
26
(AD
C2
) P
C.2
25
(ADC1) PC.124
(ADC0) PC.023
AREF20
AVCC18
(SCK) PB.517
GND5
VCC6
ADC619
GND21
ADC722
IC4
ATMEGA88_TQFP
C5
100nF/25V
GNDGND
5V
PR2
10k
C6
100nF/25V
GNDGND
5V
GND
5V
GND
5V
GND
5V
5V
GND
R24.7k
C9100nF/25V
GND
D+19
GP214
GP6/RxLED6
OSC23
OSC12
VDD1
TXD10
RXD12
RESET4
RTS11
CTS13
GP7/TxLED5
VUSB17
VSS20
GP1/USBCFG15
GP0/SSPND16
D-18
GP57
GP48
GP39
IC2
MCP2200-I/SSC14470nF/16V
C11100nF/25V
GND_USB
GND_USB
GND_USB
Q112MHz
C12
22pFC13
22pF GND_USB
LED2
G
LED1
RC10100nF/25V
GND_USB
GND_USB TXD
D1
SM4007
12V/230V
33
55
44
L1
2L
21
REL1
RM85-2011-35-1012
12VDC
OUTPUT
230VAC
5V
GND
VDD
DATAIC5
INT.SENS.
1WireB
5V
Q2
11.0592MHz
R1010k
R6
330R
R7
330R
RXD
RESET
5V
SCK
MISO
MOSI
RELAY
EXT.SENS.
5V
GND
1WireA
TX
D
RX
D
BIMETAL
1W
ire
A
1W
ire
B
GND
R9
330R
R8
330R
RED_EXT
GREEN_INT
C7100nF/25V
C8
100nF/25V
C15
1uF/10V
GND GND GND
VR1?
C16 ?
R4R
RE
LA
Y
C17?
R5R
FB1
BLM21PG221SN1D
F1
14A
IC3
ADUM1201ARZ
GND
5V
GND_USB
MOSI
VCC
RSTGND
SCK
MISO
CON8 PROG
RE
D_
EX
T
GR
EE
N_
INT
NO
NC
DC1
DC1
GND1
GND2
GND
DC2
L2
L1
NO
NC
Bi.2
Bi.1
NO
NC
GND
5V
1WireB1WireB
GND
5V
N2
N1
D+3
D-2
VBus1
GND4
CON7
USB-B-G-SMD
GND
COMM.
Bi.1
Bi.2
L
N
OUTPUT VOLTAGE SELECTION
POWER SUPPLY FOR 12VDC OUTPUTMODE
230V AC FOR 230VAC OUTPUT MODE
RELAY OUTPUTS
BIMETAL CONNECTOR
EXTERNAL SENSOR CONNECTOR
12V DC MODE:
- SHORT CIRCUIT ’INP.’ AND ’DC2’
INP.
- HEATER CONNECTED TO ’GND2’ AND ’NO’
230V AC MODE:
- SHORT CIRCUIT ’INP.’ AND ’L2’
- HEATER CONNECTED TO ’N2’ AND ’NO’
- POWER SUPPLY 12V DC CONNECTED TO "DC1" AND ’GND1’
- POWER SUPPLY 12V DC CONNECTED TO "DC1" AND ’GND1’
- HEATER POWER SUPPLY CONNECTED TO ’L1’ AND ’N1’
TEMP.ON
TEMP.OFF
R34.7k
5V
COMM.
VUSB
VUSB
LED4
G
LED3
R
BIMETAL:
- WHEN NO BIMETAL SHORT CIRCUIT Bi.1 AND Bi.2
System Requirements: - Windows XP, 7, 8, 10 (32 or 64 bit) - Dot.Net 4.0 - PL2303_Prolific_DriverInstaller_v1_11_0
Before installing the thermostat control software should install the Prolific USB port driver.
Installingsoftware
ScopeDome.com | 2015 |Slupsk | Poland 6
DriverScreenShots