PROJECT NOTES 1. IN CASE OF A DIMENSIONAL QUESTION OR DISCREPANCY. SUBMIT A REQUEST FOR INFORMATION (RFI) TO THE CONSTRUCTION COORDINATOR. 2. ONE HOUR FIRE RATED TEMPORARY CONSTRUCTION PARTITIONS SHALL BE UTILIZED WHEN CONSTRUCTION DURATION EXCEEDS 48 HOURS. PLASTIC BARRIERS ARE ACCEPTABLE WHEN CONSTRUCTION DURATION IS LESS THAN 48 HOURS. STICKY WALK - OFF DUST MATS SHALL BE PROVIDED AT ALL ENTRANCES TO CONSTRUCTION SITES. 3. SUBMIT ALL CHANGE ORDERS TO PROJECT MANAGER AND SECURE PROJECT MANAGER'S APPROVAL PRIOR TO THE COMMENCEMENT OF WORK. PROJECT SEQUENCING THE PROJECT IS INTENDED TO BE COMPLETED IN ONE PHASE. SCOPE OF WORK PROJECT DIRECTORY DESIGN MANAGER: KIDEST ALBAARI, PMP PH: (313) 577 - 3038 EMAIL:[email protected] FTCH ARCHITECT/ ENGINEERS: THIS PROJECT RENOVATES ROOM 328 AND 330, ON THE THIRD FLOOR OF THE WAYNE STATE UNIVERSITY'S RICHARD COHN BUILDING IN DETROIT, MICHIGAN. SCOPE INCLUDES ARCHITECTURAL, FIRE ALARM, ELECTRICAL, AND MECHANICAL UPGRADES AND RECONFIGURATION FOR NEW STUDENT COMMONS SPACE THAT WILL TAKE OVER BOTH ROOMS 328 AND 330. THE SPACE WILL RECEIVE NEW FINISHES AND FURNITURE THIS PROJECT WILL BE ISSUED UNDER TWO SEPARATE RPF'S AND IN TURN TWO SEPERATE CONTRACTS. 1. GENERAL CONTRACTING CONTRACT 2. FURNITURE, FURNISHINGS, AND EQUIPMENT CONTRACT FOR THE PROCURMENT AND INSTALLATION OF THE FURNITURE PACKAGE SPECIFIED IN SECTION 125000 THE RESPONSIBILITY OF EACH CONTRACT; OWNER, GENERAL CONTRACTOR, AND FURNITURE VENDOR IS DEFINED UNDER SECTION 011100 JULIET JAKOBOWSKI MAES, AIA, LEED AP, PROJECT DIRECTOR PH: (248) 324 - 1229 EMAIL: [email protected] VINCENT J. MATTINA III, AIA, CDT, ARCHITECT / PROJECT MANAGER PH: (248) 826 - 7683 EMAIL: [email protected] CARLA M. TAMBOER, INTERIOR DESIGNER PH: (616) 464 - 3894 EMAIL: [email protected] JAMES A. MILOCH, PE, LEED AP, ELECTRICAL ENGINEER PH: (248) 324 - 2127 EMAIL: [email protected] RENEE M. ZACCAGNI, PE, LEED GA, MECHANICAL ENGINEER PH: (248) 324 - 2110 EMAIL: [email protected] c o n s t r u c t o r s a r c h i t e c t s s c i e n t i s t s e n g i n e e r s Hard copy is intended to be 24"x36" when plotted. Scale(s) indicated and graphic quality may not be accurate for any other size. PROJECT NO. Drawn By Designer Reviewer Manager f i s h b e c k, t h o m p s o n, c a r r & h u b e r, i n c. PLOT INFO: © C o p y r i g h t 2 0 1 9 A l l R i g h t s R e s e r v e d www.ftch.com Engineers Scientists Architects Constructors Fishbeck, Thompson, Carr & Huber, Inc. (800) 456-3824 ACM ALUMINUM COMPOSITE MATERIAL AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AL ALUMINUM ALT ALTERNATE BF BARRIER FREE BRG BEARING CJ CONTROL JOINT CL CENTERLINE CW CURTAINWALL CLG CEILING CMU CONCRETE MASONRY UNIT CO CLEANOUT CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS DIA DIAMETER DN DOWN DS DOWNSPOUT EF EXHAUST FAN EL ELEVATION EJ EXPANSION JOINT EQ EQUAL EWC ELECTRIC WATER COOLER FD FLOOR DRAIN FRT FIRE RETARDANT TREATED FT FOOT/FEET GA GUAGE/GAGE GALV GALVANIZED GC GENERAL CONTRACTOR HB HOSE BIBB HP HIGH POINT HORIZ HORIZONTAL HVAC HEATING VENTILATING AIR CONDITIONING ID INSIDE DIAMETER IE INVERT ELEVATION IMP INSULATED METAL PANEL IN INCH/INCHES INSUL INSULATION LAV LAVATORY LED LIGHT EMITTING DIODE LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LOW POINT MFR MANUFACTURER MAX MAXIMUM MEZZ MEZZANINE MIN MINIMUM MO MASONRY OPENING MTD MOUNTED N/A NOT APPLICABLE NC NOISE CRITERIA NIC NOT IN CONTRACT NO NUMBER NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OH OVERHEAD OPP OPPOSITE ORD OVERFLOW ROOF DRAIN OS OUTSIDE PERP PERPENDICULAR PL PLATE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PVC POLYVINYL CHLORIDE R RADIUS REQD REQUIRED RD ROOF DRAIN SCH SCHEDULE SF SQUARE FOOT SGT STRUCTURAL GLAZED TILE SIM SIMILAR SP SPACE/SPACING SQ SQUARE SS STAINLESS STEEL STD STANDARD TAN TANGENT TYP TYPICAL UL UNDERWRITER'S LABORATORY UNO UNLESS NOTED OTHERWISE VERT VERTICAL VTR VENT THROUGH ROOF W/ WITH WC WATER CLOSET WH WATER HEATER W/O WITHOUT WP WEATHERPROOF WT WEIGHT GENERAL ABBREVIATIONS SEAL PROJECT INFORMATION R E V I S I O N S Wayne State University 5557 Cass Ave, Detroit, MI 48202 Cohn Building Student Commons Issued for Permits and Bids - October 31, 2019 190812 5557 Cass Ave, Detroit, MI 48202 Cohn Building Student Commons Wayne State University VJM WSU Project Number: 048-291367 39500 MacKenzie Drive, Suite 100, Novi, Michigan 48377 www.ftch.com WSU PROJECT NUMBER: 048-291367 10/31/2019 Permits and Bids C:\Work\Revit\2019_A_190812_vjmattina.rvt 10/31/2019 9:59:50 AM G101.1 COVER SHEET DRAWING INDEX G101.1 COVER SHEET LS101 LIFE SAFETY PLAN A701 FLOOR FINISH PLANS E201 THIRD FLOOR POWER AND SYSTEMS PLAN

SCOPE OF WORK Wayne State University

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SCOPE OF WORK Wayne State University

PROJECT NOTES

1. IN CASE OF A DIMENSIONAL QUESTION OR DISCREPANCY. SUBMIT A REQUEST FOR INFORMATION (RFI) TO THE CONSTRUCTION COORDINATOR.

2. ONE HOUR FIRE RATED TEMPORARY CONSTRUCTION PARTITIONS SHALL BE UTILIZED WHEN CONSTRUCTION DURATION EXCEEDS 48 HOURS. PLASTIC BARRIERS ARE ACCEPTABLE WHEN CONSTRUCTION DURATION IS LESS THAN 48 HOURS. STICKY WALK-OFF DUST MATS SHALL BE PROVIDED AT ALL ENTRANCES TO CONSTRUCTION SITES.

3. SUBMIT ALL CHANGE ORDERS TO PROJECT MANAGER AND SECURE PROJECT MANAGER'S APPROVAL PRIOR TO THE COMMENCEMENT OF WORK.

PROJECT SEQUENCING

THE PROJECT IS INTENDED TO BE COMPLETED IN ONE PHASE.

SCOPE OF WORK

PROJECT DIRECTORY

DESIGN MANAGER:

KIDEST ALBAARI, PMPPH: (313) 577-3038EMAIL:[email protected]

FTCH ARCHITECT/ ENGINEERS:

THIS PROJECT RENOVATES ROOM 328 AND 330, ON THE THIRD FLOOR OF THE WAYNE STATE UNIVERSITY'S RICHARD COHN BUILDING IN DETROIT, MICHIGAN. SCOPE INCLUDES ARCHITECTURAL, FIRE ALARM, ELECTRICAL, AND MECHANICAL UPGRADES AND RECONFIGURATION FOR NEW STUDENT COMMONS SPACE THAT WILL TAKE OVER BOTH ROOMS 328 AND 330. THE SPACE WILL RECEIVE NEW FINISHES AND FURNITURE

THIS PROJECT WILL BE ISSUED UNDER TWO SEPARATE RPF'S AND IN TURN TWO SEPERATE CONTRACTS.1. GENERAL CONTRACTING CONTRACT2. FURNITURE, FURNISHINGS, AND EQUIPMENT CONTRACT FOR THE

PROCURMENT AND INSTALLATION OF THE FURNITURE PACKAGE SPECIFIED IN SECTION 125000

THE RESPONSIBILITY OF EACH CONTRACT; OWNER, GENERAL CONTRACTOR, AND FURNITURE VENDOR IS DEFINED UNDER SECTION 011100

JULIET JAKOBOWSKI MAES, AIA, LEED AP, PROJECT DIRECTOR

PH: (248) 324-1229

EMAIL: [email protected]

VINCENT J. MATTINA III, AIA, CDT, ARCHITECT / PROJECT MANAGER

PH: (248) 826-7683

EMAIL: [email protected]

CARLA M. TAMBOER, INTERIOR DESIGNER

PH: (616) 464-3894

EMAIL: [email protected]

JAMES A. MILOCH, PE, LEED AP, ELECTRICAL ENGINEER

PH: (248) 324-2127

EMAIL: [email protected]

RENEE M. ZACCAGNI, PE, LEED GA, MECHANICAL ENGINEER

PH: (248) 324-2110

EMAIL: [email protected]

c o n s t r u c t o r s

a r c h i t e c t s

s c i e n t i s t s

e n g i n e e r s

Hard copy is intended to be24"x36" when plotted. Scale(s)

indicated and graphic quality maynot be accurate for any other size.

PROJECT NO.

Drawn By

Designer

Reviewer

Manager

f i s h b e c k, t h o m p s o n, c a r r & h u b e r, i n c.

PLO

T IN

FO

:

© C o p y r i g h t 2 0 1 9A l l R i g h t s R e s e r v e d

www.ftch.com

Engineers Scientists Architects Constructors

Fishbeck, Thompson, Carr & Huber, Inc.

(800) 456-3824

ACM ALUMINUM COMPOSITE MATERIALAFF ABOVE FINISHED FLOORAHU AIR HANDLING UNITAL ALUMINUMALT ALTERNATEBF BARRIER FREEBRG BEARINGCJ CONTROL JOINTCL CENTERLINECW CURTAINWALLCLG CEILINGCMU CONCRETE MASONRY UNITCO CLEANOUTCONC CONCRETECONST CONSTRUCTIONCONT CONTINUOUSDIA DIAMETERDN DOWNDS DOWNSPOUT

EF EXHAUST FANEL ELEVATIONEJ EXPANSION JOINTEQ EQUALEWC ELECTRIC WATER COOLERFD FLOOR DRAINFRT FIRE RETARDANT TREATEDFT FOOT/FEETGA GUAGE/GAGEGALV GALVANIZEDGC GENERAL CONTRACTORHB HOSE BIBBHP HIGH POINTHORIZ HORIZONTALHVAC HEATING VENTILATING AIR

CONDITIONINGID INSIDE DIAMETERIE INVERT ELEVATIONIMP INSULATED METAL PANEL

IN INCH/INCHESINSUL INSULATIONLAV LAVATORYLED LIGHT EMITTING DIODELLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLP LOW POINTMFR MANUFACTURERMAX MAXIMUMMEZZ MEZZANINEMIN MINIMUMMO MASONRY OPENINGMTD MOUNTEDN/A NOT APPLICABLENC NOISE CRITERIANIC NOT IN CONTRACTNO NUMBER

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALEOC ON CENTEROD OUTSIDE DIAMETEROH OVERHEADOPP OPPOSITEORD OVERFLOW ROOF DRAINOS OUTSIDEPERP PERPENDICULARPL PLATEPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPVC POLYVINYL CHLORIDER RADIUSREQD REQUIREDRD ROOF DRAINSCH SCHEDULESF SQUARE FOOT

SGT STRUCTURAL GLAZED TILESIM SIMILARSP SPACE/SPACINGSQ SQUARESS STAINLESS STEELSTD STANDARDTAN TANGENTTYP TYPICALUL UNDERWRITER'S LABORATORYUNO UNLESS NOTED OTHERWISEVERT VERTICALVTR VENT THROUGH ROOFW/ WITHWC WATER CLOSETWH WATER HEATERW/O WITHOUTWP WEATHERPROOFWT WEIGHT

GENERAL ABBREVIATIONS

SEAL

PROJECT INFORMATION

R E V I S I O N S

Wa

yn

e S

tate

Un

ive

rsit

y5

55

7 C

ass A

ve, D

etr

oit,

MI

48

20

2

Co

hn

Bu

ildin

g S

tud

en

t C

om

mo

ns

Issued for Permits and Bids - October 31, 2019

190812

5557 Cass Ave, Detroit, MI 48202

Cohn Building Student Commons

Wayne State University

VJM

WSU Project Number: 048-291367

39500 MacKenzie Drive, Suite 100, Novi, Michigan 48377

www.ftch.com

WS

U P

RO

JE

CT

NU

MB

ER

: 048-2

91367

10/31/2019 Permits and Bids

C:\W

ork

\Re

vit\2

019

_A

_19

081

2_vjm

attin

a.r

vt

10

/31/2

01

9 9

:59

:50

AM

G101.1

COVER SHEET

DRAWING INDEX

G101.1 COVER SHEETLS101 LIFE SAFETY PLANA701 FLOOR FINISH PLANSE201 THIRD FLOOR POWER AND SYSTEMS PLAN

Page 2: SCOPE OF WORK Wayne State University

60' -

6"

32' - 6"

19' -

0"

7' -0"

11' -

0"

25' - 6"

19' -

0"

6' -0"

6' -0"

1

ACDFH

2

3

4

5

6

7

8

9

10

11

12

13

14

15

B

1218 SF

STUDENT

COMMONS

80

FIRE SHUTTER

G

FIRE SHUTTER

1HR

ON GRADE

LOCATION OF DUMPSTER

EXISTING TRASH CORRAL

1HR

2HR

1HR

1HR

1HR

1HR

1HR

OCCUPANCY

ITEM CODE SECTION

REMARKSUL NO.

(HOURS)

RATINGITEM

FIRE RESISTANCE RATINGS OF STRUCTURAL ELEMENTS

TYPE OF CONSTRUCTION

BUILDING USE GROUP

CODES

(SEC. 1023.2)EXISTING1STAIR ENCLOSURES

(SEC. 713.4)EXISTING2SHAFT ENCLOSURES

(TABLE 601)EXISTING0INT.

(TABLE 601)EXISTING1INT.

ROOF CONSTRUCTION 1 EXISTING (TABLE 601)

(INCL. AMENDMENTS)

(TABLE 601)

(TABLE 601)

(TABLE 601)

(TABLE 601)

EXISTING

EXISTING

EXISTING

EXISTING

1

0

1

1

FLOOR CONSTRUCTION

NONBEARING WALLS - EXT.

BEARING WALLS - EXT.

STRUCTURAL FRAME

CONSTRUCTION TYPE: II-A (ASSUMED) NON-SPRINKLERED (MBC-SEC: 602) TYPE II (III) (ASSUMED) NON-SPRINKLERED (NFPA: 7.2.1.1)

BUILDING USE (MBC-SEC: 304)

MIXED USE NON-SEPARATED: B - BUSINESS / A-3 - ASSEMBLY

2012 NFPA 101 LIFE SAFETY CODE2015 MICHIGAN REHABILITATION CODE (AS AMENDED) - Chapters 7 & 82015 MICHIGAN MECHANICAL CODE (AS AMENDED)2015 MICHIGAN PLUMBING CODE (AS AMENDED)2017 NATIONAL ELECTRIC CODE (NEC) (AS AMENDED - MICHIGAN AMENDMENTS PART 8 RULES)2015 MICHIGAN ENERGY CODE

INTERNATIONAL ENERGY CONSERVATION CODE - 2009, SECTION 501.1ANSI/ASHRAE/IESNA STANDARD 90.1-2007 (AS AMENDED)

2015 INTERNATIONAL FIRE CODEBARRIER FREE REQUIREMENTS:

AMERICANS WITH DISABILITIES ACT (ADA)MBC-2015, CHAPTER 11ICC A117.1-2009, EXCEPT SECTIONS 611 & 707

EGRESS COMPONENTS WITHIN THE WORK AREA (TABLE 1005.3)

OCCUPANCY 80

AREA OF RENOVATION: 80 PEOPLE x 0.2"/PERSON = 16 INCHES

PROVIDED: 2 DOORS @ 33 INCHES CLEAR = 66 INCHES

FIRST THRU THIRD FLOOR: 690 PEOPLE x 0.3"/PERSON = 207 INCHES (44 MIN.)

PROVIDED: 2 STAIR @82 INCHES CLEAR = 164 INCHES

STAIRWAYS 0.3" OTHER COMPONENTS 0.2"

1 STAIR @44 INCHES CLEAR = 44 INCHES

THE DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH THE FOLLOWING

CODES, NOTIFY THE ARCHITECT OF ANY CONFLICTS

CLASSIFICATION OF WORKCLASSIFICATION TYPE (MRC-CHAPTER 5)

LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT.

OCCUPANT LOAD:

2012 NFPA 101 LIFE SAFETY CODE, TABLE 7.3.1.22015 MICHIGAN BUILDING CODE, TABLE 1004.1.2

ASSEMBLY UNCONCENTRATED (TABLES AND CHAIRS)1 / 15 NET (IN AREA OF RENOVATION)

CURRENT BUILDING OCCUPANCY (ASSUMED): GROUND FLOOR: 208 OCCFIRST FLOOR: 209 OCCSECOND FLOOR: 209 OCCTHIRD FLOOR: 209 OCCTOTAL: 835 OCC

OCCUPANTS ADDED BY RENOVATION: GROUND FLOOR: 0 OCCFIRST FLOOR: 0 OCCSECOND FLOOR: 0 OCCTHIRD FLOOR: 63 OCCTOTAL: 63 OCC

PROPOSED BUILDING OCCUPANCY INCLUDING REOVATION:GROUND FLOOR: 208 OCCFIRST FLOOR: 209 OCCSECOND FLOOR: 209 OCCTHIRD FLOOR: 272 OCCTOTAL: 898 OCC

THE PROPOSED BUILDING OCCUPANCY HAS INCREASED BY 7.5%

PLUMBING FIXTURE REQUIREMENTS:

PER THE MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS, SECTION 810 MINIMUM FIXTURES. WHERE THE OCCUPANT LOAD OF THE STORY IS INCREASED BY MORE THAN 20 PERCENT, PLUMBING FIXTURES FOR THE STORY SHALL BE PROVIDED IN QUANTITIES SPECIFIED IN THE INTERNATIONAL PLUMBING CODE BASED ON INCREASED OCCUPANT LOAD.

PROJECT COMPLIES: NO MODIFICATIONS TO THE PLUMBING FIXTURE COUNT IS REQUIRED.

MEANS OF EGRESS IN WORK AREAS:

A MINIMUM OF TWO MEANS OF EGRESS ARE PROVIDED FROM ALL RENOVATION AREAS.

COMMON PATH OF TRAVEL: 75' WITHOUT SPRINKLERS (TABLE 1006.2.1)PROJECT COMPLIES (MBC) (NFPA)

EXIT ACCESS TRAVEL DISTANCE: 200' WITHOUT SPRINKLERS (TABLE 1017.2)PROJECT COMPLIES

(NFPA 8.3.3.11)U4191CORRIDOR WALLS IN AREA OF RENOVATION

LIFE SAFTEY KEY

BUILDING CODE INFORMATION

TOTAL: 208 INCHES - PROJECT COMPLIES

THIRD FLOOR: 272 PEOPLE x 0.2"/PERSON = 54.4 INCHES

PROVIDED: 10 DOORS @ 33 INCHES CLEAR = 330 INCHES

c o n s t r u c t o r s

a r c h i t e c t s

s c i e n t i s t s

e n g i n e e r s

Hard copy is intended to be24"x36" when plotted. Scale(s)

indicated and graphic quality maynot be accurate for any other size.

PROJECT NO.

Drawn By

Designer

Reviewer

Manager

f i s h b e c k, t h o m p s o n, c a r r & h u b e r, i n c.

PLO

T IN

FO

:

© C o p y r i g h t 2 0 1 9A l l R i g h t s R e s e r v e d

www.ftch.com

R E V I S I O N S

Wa

yn

e S

tate

Un

ive

rsit

y5

55

7 C

ass A

ve, D

etr

oit,

MI

48

20

2

Co

hn

Bu

ildin

g S

tud

en

t C

om

mo

ns

190812

VJM

KEY PLAN

NORTH

WS

U P

RO

JE

CT

NU

MB

ER

: 048-2

91367

10/31/2019 Permits and Bids

C:\W

ork

\Revit\2

019

_A

_1

90

812

_ja

pym

an.r

vt

10

/31/2

01

9 8

:54

:21

AM

LS101

LIFE SAFETY PLANS

YF/CT

WTB

JP

NORTH

SCALE: 1/16" = 1'-0"

THIRD FLOOR LIFE SAFETY PLAN

#

33' - 3"

1-HOUR WALL

2-HOUR WALL

OCCUPANT COUNT

TRAVEL DISTANCE

Page 3: SCOPE OF WORK Wayne State University

LVT2

LVT1

PLANKDIRECTION

PLANKDIRECTION

LVT2

PLANKDIRECTION

LVT1

PLANKDIRECTION

LVT1

LVT1

VWC1

7'-10"

P2

P1

P1

C2

C2

C3C3

C1

C3

C3

C3C3

C4 C4

C4

C4

C5

C5

C5

C5

C5

C5

C5

C5

C5

C5

C5

C5

C5

C6

C6 C6

C6 C6

C6 C6

C6

C6

C6 C6

C6

C7

C7

C7

C7

T1

T2

T2

T3

T3 T3

T4

T5

2'-0"

11 3/4"

ALIGN

7'-10"

R 2

' - 5

"

R 5

' - 0

"

c o n s t r u c t o r s

a r c h i t e c t s

s c i e n t i s t s

e n g i n e e r s

Hard copy is intended to be24"x36" when plotted. Scale(s)

indicated and graphic quality maynot be accurate for any other size.

PROJECT NO.

Drawn By

Designer

Reviewer

Manager

f i s h b e c k, t h o m p s o n, c a r r & h u b e r, i n c.

PLO

T IN

FO

:

© C o p y r i g h t 2 0 1 9A l l R i g h t s R e s e r v e d

www.ftch.com

R E V I S I O N S

Wa

yn

e S

tate

Un

ive

rsit

y5

55

7 C

ass A

ve, D

etr

oit,

MI

48

20

2

Co

hn

Bu

ildin

g S

tud

en

t C

om

mo

ns

190812

VJM

KEY PLAN

NORTH

WS

U P

RO

JE

CT

NU

MB

ER

: 048-2

91367

10/31/2019 Permits and Bids

C:\W

ork

\Revit\2

019

_A

_1

90

812

_ja

pym

an.r

vt

10

/31/2

01

9 8

:54

:10

AM

A701

FLOOR FINISH PLANS

YF/CT

WTB

CT

NORTH

SCALE: 1/4" = 1'-0"

THIRD FLOOR FINISH PLAN

• ALL WALLS TO BE FACED WITH PLASTIC LAMINATE (PL1) UNLESS NOTED OTHERWISE.

NOTES

Page 4: SCOPE OF WORK Wayne State University

AV

A

TV

AV

AV

K

W

W

KK

K

USB

9"

USB9"

9"USB

1

USB9"

USB

9"

2

2

2

2

2

USB

USB 9"

USB

USB

USB

9"

9"

2

2

2

USB

USB

USB

USB

USB

USB

USB

USB

48"

48"

48"

48"

48"

45"

45"USB

46"

46"

46"

46"

30"

30"

30"30"

DIGITAL BULLETINBOARD. COORDINATE ALL REQUIREMENTS WITHTHE WSU A/V PREFERREDVENDOR.

72"67"

LP-3B

LP-3BA

ELP-3B

LP-3B-35AP

AP

LP-3B-23

LP-3B-31

LP-3B-5

LP-3B-3

3

2D

6D

4

34"USB

USBUSB

USB

60"

1

LP-3B-12

LP-3B-37

5

5

5

5

ACD

7

8

9

10

B

6

c o n s t r u c t o r s

a r c h i t e c t s

s c i e n t i s t s

e n g i n e e r s

Hard copy is intended to be24"x36" when plotted. Scale(s)

indicated and graphic quality maynot be accurate for any other size.

PROJECT NO.

Drawn By

Designer

Reviewer

Manager

f i s h b e c k, t h o m p s o n, c a r r & h u b e r, i n c.

PLO

T IN

FO

:

© C o p y r i g h t 2 0 1 9A l l R i g h t s R e s e r v e d

www.ftch.com

R E V I S I O N S

Wa

yn

e S

tate

Un

ive

rsit

y5557 C

ass A

ve, D

etr

oit, M

I 48202

Co

hn

Bu

ildin

g S

tud

en

t C

om

mo

ns

190812

VJM

KEY PLAN

NORTH

WS

U P

RO

JE

CT

NU

MB

ER

: 048-2

91367

10/31/2019 Permits and Bids

C:\W

ork

\Revit\2

019

_E

_1

90812

_JM

5.r

vt

10/3

1/2

01

9 1

1:4

7:0

8 A

M

E201

THIRD FLOOR POWER ANDSYSTEMS PLAN

JAM

RMM

CJM

NORTH

SCALE: 1/4" = 1'-0"

THIRD FLOOR POWER AND SYSTEMS PLAN

NOTES

1.

2.

3.

4.

REFER TO DRAWING E001 FOR THE ELECTRICAL GENERAL NOTES AND REQUIREMENTS.

CIRCUIT NUMBERS ARE SHOWN FOR GROUPING PURPOSES ONLY. UTILIZE CIRCUITS MADE AVAILABLE THROUGH DEMOLITION OR SPARE CIRCUIT BREAKERS. ALL BRANCH CIRCUIT WIRING SHALL BE NEW.

PROVIDE WIRING DEVICE COVERPLATE SAMPLES FOR REVIEW DURING THE SHOP DRAWING SUBMITTAL PROCESS.

ALL DATA CABLING AND ASSOCIATED RACEWAYS SHALL BE INSTALLED PER WAYNE STATE STANDARDS FOR COMMUNICATIONS INFRASTUCTURE - 29 JULY 2019.

KEY NOTES

1 FIRE ALARM CONTROL MODULE TO RELEASE FIRESHUTTERS UPON FIRE ALARM ACTIVATION.

2 MOUNT HORIZONTALLY IN THE VERTICAL PORTION OFTHE BENCH.

3 POWER FEED FOR FURNITURE "D" TABLE, REFER TO THECONNECTRAC DETAIL ON E501.

4 LOW VOLTAGE FEED FOR FURNITURE "D" TABLE. REFERTO THE CONNECTRAC DETAIL ON E501.

5 4#12, #12 GRD, 3/4"C.

6 RELOCATED WIRELESS ACCESS POINT.

WIRING DEVICES - MANUAL POWER SWITCH SCHEDULE

SYMBOL DESCRIPTION MANUFACTURER CATALOG NO. REMARKS

KKEYED MANUAL SWITCH PROVIDED BY FIRE

SHUTTERMANUFACTURER

WIRING DEVICES - RECEPTACLE SCHEDULE

SYMBOL DESCRIPTION MANUFACTURER CATALOG NO. REMARKS

DUPLEX RECEPTACLE HUBBELL HBL5362I MOUNT 18" AFF, UNO

DUPLEX RECEPTACLE (ABOVECOUNTER)

HUBBELL HBL5362I MOUNT HORIZONTALLY ABOVE COUNTER; 2-INCHES ABOVEBACKSPLASH, UNO

USBDUPLEX RECEPTACLE WITH TWO USBCHARGING PORTS

HUBBELL USB8300I MOUNT 18" AFF, UNO

USBDUPLEX RECEPTACLE WITH TWO USBCHARGING PORTS (ABOVE COUNTER)

HUBBELL USB8300I MOUNT HORIZONTALLY ABOVE COUNTER; 2-INCHES ABOVEBACKSPLASH, UNO

USBDOUBLE DUPLEX RECEPTACLE WITHFOUR USB CHARGING PORTS

HUBBELL (2) USB8300I MOUNT AT 18" AFF, UNO

2-GANG RECESSED WALL BOX FORVIDEO MONITOR POWER AND DATAWITH DUPLEX RECEPTACLE

LEGRANDWIREMOLD

EFSB2 MOUNT AT 18" AFF, UNO; PROVIDE (1) HUBBELL #HBL5362IDUPLEX RECEPTACLE