SCOPE OF WORK- SUPPLY OF IT HARDWARE AND SOFTWARE LICENCES
OF NAVY IT SYSTEMS / SERVERS
1. The selected bidders have to supply, install and commission the items being
procured as per the proposed layout at INS Valsura, Jamnagar, Gujarat-361150.
2. The preparation of venue, provisioning of power supply sockets, electrical
cabling and Air Conditioning will be undertaken by Indian Navy. The bidders will
have to install the IT Hardware at the designated location at INS Valsura including
configuration of Virtualisation and installation of contracted software.
3. The Technical specifications mentioned as per Appendix ‘C’ are to be
considered as minimum specifications required.
4. The Warranty for all IT Hardware and service support for all software products
in the tender will be three years (comprehensive warranty). Software Assurance is
only required where specifically mentioned in the tender document. No changes in
tender can be made at this stage.
4. The proposed layout of the installation is as follows:-
WORKSTATION
Parameter Minimum specification required
Processor Intel Xeon W 3565/E5-1607 processor, 3.2 GHz, 8 MB L3 Cache or higher
Chipset Intel X 58 chipset.
Memory 4 GB DDR3 1600 MHz, Memory expandability upto 64 GB.
Hard Disk Drive 500 GB SATA at 7200 rpm upgradeable to 2 HDD.
Keyboard Standard Keyboard
Mouse USB Optical Mouse with Scroll (OEM Make)
DVD Drive 8X DVD ROM or Higher or Optical Drive
Monitor TFT Monitor High resolution Graphics (1920x1200), 60.9 cm (24 inches) or higher
Bays Total 4 Bays with minimum 2 internal and 1 external.
PCI Slots 4 PCI / PCI Express including 1 PCI Express x 16
Ports 5 USB 2.0, 2 USB 3.0, parallel port, RJ-45, audio in, audio out, mic in.
Cabinet Mini Tower
Networking 10/100/1000 on board integrated Network Port
Graphics N-VIDIA Quadro 4000 (2GB) or higher/ ATI Firepro V7900 (2GB) or higher.
Power Supply 230 v +/- 10% single phase, 50 Hz AC
Power Management
ACPI (Advanced Configuration and Power Management)
Management System Health Monitoring Tool available with H/W box
Warranty Onsite warranty for three years from the date of commissioning
OS Certifications
Windows 7 Logo & Red Hat or SuSe Linux or
Ubantu Operating System Microsoft Windows 7 Professional (64 bit)or higher Antivirus Norton / McAfee / e-trust/ Symantec with one year
license
Storage Controller SATA Controller with RAID 0/1
Safety Certifications
FCC for EMI and UL for Safety, OS-Windows/Red Hat/Suse Linux
Security Integrated panel lock/pad lock
Keyboard USB Standard Keyboard (OEM)
Mouse USB Optical Scroll Mouse (OEM Make)
- 2 -
BLADE SERVER
BLADE SERVER FOR 10 BLADE CHASSIS
INTEL XEON SIX CORE TWO PROCESSOR
Parameter Minimum specification required
CPU 2 nos. of E5-2630v2 , 2.6GHz,15MB Smart cache, 7.2GT/S, six core,80 watts, Memory Speed 1333/1066/800 MHz, DDR3 Only or higher
Mother board OEM Motherboard
Memory 2 x 64 GB RDIMMS at 1333 MHz, scalable to 512 GB or higher
Hard Disk Drive 2 x 600 GB 10K RPM SFF SAS Hot Plug or higher
Hard Disk Controller
SAS Based supporting Raid 0/1 with 512 MB Cache
Multifunction ports Min Two 10 Gigabit Ports
Fiber Channel Ports Min 2 Ports 8 Gb/s
Management OS Independent Hardware heath Status
Keyboard Virtual KVM based remote control
Power Management Remote Power Control
Add On Items for Blade Servers
Ser Description
1
Fiber Channel Pass Through for SAN Connectivity to provide at least two number of 4 GB/s ports from each blade server to an external SAN Switch for 7 / 16 Blade System
- 3 -
SERVER STORAGE DEVICE- STORAGE AREA NETWORK (SAN)
Operating System & Clustering Support
1. The storage array should support industry-leading Operating System platforms including: Windows Server 2008 R2, Windows 2012.
2. Offered Storage Shall support all above operating systems in Clustering.
Capacity & Scalability
1. The Storage Array shall be offered with minimum 3TB usable Capacity with 7.2/15k SATA/SAS drives
2. Storage shall be scalable to minimum of 50 number of drives or greater than 25TB using 300GB SAS drives.
Controller
The storage array should support dual, redundant, hot-pluggable, active-active array controllers for high performance and reliability
Minimum Usable capacity
10 TB
Cache
1. Offered Storage Array shall be given with Minimum of 2GB cache per controller in a single unit after removing the operating system overhead.
2. Cache shall be backed up in case of power failure for indefinite time either using batteries or capacitors or any other equivalent technology.
Front-end Ports
Offered Storage subsystem shall have total of 4 number of native FC ports running at 8Gbps speed and 4 number of Native iSCSI ports running at 1Gbps speed.
Back-end
Offered Storage subsystem back-end engine shall be running on latest SAS - II (6Gbps) loop speed.
Raid Support
Offered Storage Subsystem shall support Raid 0, 1 , 1+0 , 3, 5, 5+0 and Raid 6 levels
Load Balancing & Muti-path
Multi-path and load balancing software shall be provided, if vendor does not support
- 4 -
MPIO functionality of Operating system.
SAN Switch Two 8 port 8Gbps FC switches must be provided for SAN connectivity of a storage system and server(s).
FC HBA Dual port FC HBA
BLADE SERVER CHASSIS
1. Blade Chassis shall accommodate the specified maximum number of Blade Servers with hot swappable HDD, Interconnect Modules, Power supplies, Fans and Management Modules. 2. It shall include all accessories so that it can be mounted on an Industry Standard 42 U Rack. 3. It shall be fully populated with Power Supplies with N+N redundancy. 4. It shall be supplied with the PDUs to connect Power Cables to the Chassis power input terminals. 5. It shall be fully populated with fans for cooling with adequate redundancy built in for the entire enclosure & its components. 6. It shall be complete with required number of Managed Ethernet Switches to provide at least two no of 1 Gb/s Ports connectivity from each Blade Server 7. Management Module which provides a single point of control for intelligent management of the entire console. It should provide setup & Control of Enclosure, should report asset and inventory Information for all the devices in the Enclosure. It should report Thermal & Power Information of per Server & per Enclosure and it should provide KVM functionalities & Access for all the Server Blades from the Management Module.
- 5 -
SERVER RACK- 42 U
Server rack enclosures provide door ventilation that meets or
exceeds OEM server manufacturer requirements. The depth of the rack enclosures should provides a rear power distribution channel which allows for zero-U mounting of rack Power Distribution Units. It should provide enough depth for data and power cable management. The detailed specifications for the server racks are appended below:
S.No. Specifications for Server Racks
A SUMMARY
B General Specifications.
(i) The unit shall be designed to provide a secure, managed environment for server and networking equipment.
(ii) The unit shall conform to EIA-310 Standard or Indian equivalent
(iii) The unit shall be available with a vertical equipment mounting space of 42U or (1U=1.75” or 44.45mm).
C Physical Specifications
(i) The unit shall have 42U height with minimum 1000 depth. Width will be 600MM for server racks & 750mm for network racks.
(ii) The 42U and units shall support a static load of 1200KG.
(iii) The front door of unit shall be reversible so that it may open from either side.
(iv) The RACK should have a 17’’ TFT & rail kit.
(v) The units shall have 3/2 perforated front door, perforated split rear doors, and removable side panels
(vi) All racks shall have IP20 protection and shall be inherently earthed or grounded directly to the frame.
(vii) The unit shall provide adequate ventilation to provide airflow required by the major server manufacturers.
(viii) The unit shall have clearance for wiring access of at least 3” between the inside surface of the front door and front mounting face of the vertical mounting rails.
(ix) The unit shall have clearance for wiring access of at least 1.5” between the side panel and the vertical mounting rails.
(x) The unit shall include front door lock, rear door lock and side panel lock that are keyed the same
(xi) The unit shall have mounting provisions for optional door alarm switch to monitor access to the enclosure doors.
- 6 -
INTERACTIVE WHITE BOARD
Dimension with stand External Dimensions (WxHxD) with stand: Minimum 1340 x 1210 x 76.2 mm
Panel Dimension without stand (WxH) 1175 x 1090 mm
Surface material PET Coated metal plate
Interactive Function USB 2.0
Position Sensor Ultrasonic receiver & infrared rays sensor
System Interface Requirement Any PC with USB ports
Accessories
Electronic Pen/ Stylus, Eraser, operating instruction with installation manual, batteries (if applicable), USB cable, Software CD-ROM , wall mounting kit or floor stand
TFT – MONITORS- 24”
Screen Size (Diagonal) 24”
Aspect Ratio 16:10
Effective Display Area (W x H) 14.8x11.8
Resolution 1280x1024 pixels
Contrast Ratio 200:1
Input / Output S-Video, Serial, HDMI, Ethernet, USB
Weight: Minimum 2-5 Kgs
Color Black /Grey
Note: PDU & Server Rack need to be procured along with the UPS Configurations.
- 7 -
30 KVA (With Redundant Battery Bank) UPS
(SUPPORTING: MINIMUM 4 – 5 SERVER’S, 1 STORAGE & 10 PC’S)
Power Rating 30 KVA
Configuration 30 KVA (with redundant battery bank) UPS with 30 min Backup and sealed maintenance free batteries.
PARAMETERS
INPUT
Nominal Voltage & Range
AC Input Nominal Voltage: 440/415 V, 3 Phase, 4 wire + G, 50 Hz.
Frequency 40-70Hz
Power Factor > 0.97 at 100% load
OUTPUT
Voltage range AC Output Nominal Output: 230V, 1 Phase, 4 wire + G, 50 Hz ((+ - 1%)
Voltage Distortion Max 3% @ 100% Linear Load.
Inverter Overload 150% for 30 Sec
Power Factor The UPS output shall not require de-rating for purely resistive loads (PF of 1). The potential KW and KVA ratings of the UPS output shall be equal. For loads exhibiting a power factor of 0.9 leading to 0.8 lagging, no de-rating of the UPS shall be required.
OUTPUT DISTRIBUTION
The Data Center Distribution shall be part UPS frame with By-Pass, Input/Output breakers along with snap-on type distribution miniature circuit breakers inbuilt in it.
Battery
Type
The UPS batteries shall be sealed lead acid and maintenance free.
Battery Management
The UPS shall incorporate a battery management system to continuously monitor the health of each battery bank.
- 8 -
ENVIRONMENTAL AND OTHER
Operating Ambient Temperature
0-40 degree C / 9.5 % RH or less (Non- Condensing)
Approvals ISO 14001,ISO 9001
Connectivity Should have an Ethernet port for online monitoring of UPS State
Emergency Power Off (EPO)
Required
Efficiency at Full Load
94%
NETWORKING ACTIVE COMPONENTS
NETWORKING SWITCH (Core)(L3 Switch)
48 * 10/100/1000 Base T or higher and two 10 Gig interfaces
Have a switching fabric backplane of 150 GBPS
Support's performance rating of minimum 101 Million PPS.
Support basic Layer 3 Protocol such as static routes, RIP v1/v2, DHCP relay, OSPF, OSPFV3, PBR, PIM-5M
Gigabit Ethernet Uplink Option like SX, LX, T, SR, LR
255 VLANs & Support 4000 VLAN IDs or higher, 1000 VLANs
Compact Flash Memory 64 MB and DRAM 128 MB
Support for EAP and MAC based security
8000 MAC address support or higher
Support for L2/L3 Ingress Traffic Policing
Should support IPv6 and EAL compliance
Should support VRRP / HSRP
Should support 802.1x based authentication
Should support IPv6 First hop security features to prevent spoofing attacks
Should support Unicast Reverse Path Forwarding check
Should support 802.1ae Band Security
- 9 -
NETWORKING SWITCH (Backbone)(L2/L3 switch)
24 * 10/100/1000 Base T or higher and two 10 Gig interfaces
Stackable and have a switching fabric backplane of 150 GBPS
Supports performance rating of minimum 60 Million PPS.
Support basic Layer 3 Protocol such as static routes, RIP v1/v2, DHCP relay, OSPF, OSPFV3, PBR, PIM-5M
Gigabit Ethernet Uplink Option like SX, LX, T, SR, LR
255 VLANs & Support 4000 VLAN IDs or higher, 1000 VLANs
Compact Flash Memory 64 MB and DRAM 128 MB
Support for EAP and MAC based security
8000 Unicast MAC address support or higher
Support for L2/L3 Ingress Traffic Policing
Should support IPv6 and EAL compliance.
Should support VRRP / HSRP
Should support 802.1x based authentication
Should support IPv6 First hop security features to prevent spoofing attacks
Should support Unicast Reverse Path Forwarding check
Should support 802.1ae Band Security
Supply of IT Hardware and Software Licences of Navy IT Systems / Servers
RFP No IT/009/04 Dated 02 Feb 15
Salient Timelines
• RFP Floated on - 02 Feb 15
• Pre Bid Meeting - 13 Feb 15at Sena Bhawan
• Tender Submission - 26 Feb 15(last date)
by 1200 Hrs
• Tender Opening - 26 Feb 15 at 1500 Hrs
(Note: Firms to depute maximum two reps during
tender opening)
Schedule of Requirements
IT Hardware Required
S.No Item Description Qty
1 WorkStation: As per technical specifications at Appendix C (Preferably Lenovo/IBM/HP/ Dell make) 432 Add on items for workstations: Items- 1000 GB Hard Disk, 7200 RPM, 10
3 24” TFT Monitor for high resolution graphics, (1280 x 1024), 60.9 CM/ 24”. As per technical specifications at Appendix C 20
4 Interactive Board: Min, Diagonal Size(mm) 2400, Aspect Ratio: 16:9, Linux Compatibility: No, Auto Calibration: No. As per technical specifications at Appendix C
3
5 Color copier ( size A3) Minimum copying speed: 20 Color/ 20 mono, RAM(MB) 512, Tray CapacityL 2 X 500 sheets, Hard disk - 40 GB 1
Consignee Details - The Commanding Officer (for OIC ITSS) INS Valsura Jamnagar Gujarat – 361150 (Tel – 0288-3987280/281)
Delivery Period - Delivery period for supply of items would be 60 days from the effective date of contract.
Schedule of Requirements
6 Blade Server Chasis with Storage on Blade, Max no of Blades: 10, No. of blades populated: 4, Blade configuration: As per technical specifications at Appendix C. (Preferably HP/IBM/Dell make)
1
7 Add on Items for Blade Server Console: Item: SAN Switch Brocade 4 Gb 20 Port for 6 Nos. Blade System 2
8 Server Rack 42U with dual power inputs. As per technical specifications at Appendix C 1
9 SAN System 10TB Usable Capacity on 6Gbps or Higher Disc.As per technical specifications at Appendix C
1
10 48 Port L3 Switch, GigE 4 x 1G SFP LAN Base, with 5 Yrs Onsite Warranty, Support & installation all inclusive. As per technical specifications at Appendix C
1
11 24 Port L2/L3 Switch, GE SFP IP Base, C3KX-NM-1G, with 5 Yrs Onsite Warranty, Support & installation all inclusive. As per technical specifications at Appendix C
1
12 1000BASE-SX SFP transceiver module MMF 850nm DOM, with 5 Yrs onsite warranty, support & installation. All inclusive. 2
IT Hardware Required
13 On-Line UPS with isolation transformer and Redundant battery bank, suitable for Three Phase AC Input and Single Phase AC output, Floor Mounted Type, Rating of UPS: 30 KVA, Indicative Back-up time: 30 Minutes. As per technical specifications at Appendix C.
1
Schedule of Requirements
14 (VCS5-STD-C) VMWare vCenter Server 5 Standard for vSphere 5(Per instance)(Up to 50 Licenses) 3
15 (VCS5-STD-3P-SSS-C) Production support/Subscription for vCenter Server 5 Standard for vSphere 5 for 3 years(Up to 50 Licenses)
3
16 (VS5-OSTD-C) Vmware vSphere with Operations Management Standard for 1 Processor 8
17 (VS5-OSTD-3P-SSS-C) Production support/Subscription VMware vSphere with Operations Management Standard for 03 Years 8
18 (VC-SRM5-25S-C) Vmware vCenter Site Recovery Manager 5 Standard (25 VM Pack) 1
19 (VC-SRM5-25S-3P-SSS-C) Production support/Subscription for Vmware vCenter Site Recovery Manager 5 Standard (25 VM Pack for 3 years)
1
20 Windows Server Standard 2012 R2 – 2 Processors 4
21 SQL Server Standard Core 2012 (2 Licenses) 1
22 Share Point Std CAL 2013 1
23 Project Professional 2013 with 1 Project Sever CAL 1
24 Exchange Server Standard 2013 1
25 Office Standard 2013 4
26 Visual Studio Professional with MSDN ALNG Lic+SA 1
Software Licences Required
Vendor Qualification
(a) The bidder or the group company should be an IT company registered in India and registered with Govt. / Indian
Naval Establishment/ Dept.
(b) Average annual turnover of at least Rs 1 Cr during last three years.
(c) Should be a certified partner of the OEM - Proof of certificate from OEM valid for a period of at least one
year from the tender date to be enclosed. Should also include tender specific authorisation.
(d) Similar Project Experience as detailed below.
Vendor Qualification
• Similar IT related projects must include at least one order of Rs 01 Cr
with State Govt/ Central Govt/ Defence/ PSU/Nationalised Banks/ Quasi
Govt/ Any reputed private organistaion.
• Experience of having successfully completed similar IT projects during last
7 years. Similar projects would be Supply and Installation of IT Hardware
and Software Licences.
•Work order to specify – Supply of IT Hardware viz. Blade Servers, SAN
storage etc., type of software licences supplied, product support and work
completion certificate.
Generic Instructions
• Navy reserves right to reject bids that do not contain complete data /have
incorrect data without seeking clarifications
• Bids will be page numbered: Every page including covering letter will be
numbered
• Bids without tender fees will be summarily rejected at opening stage
• Compliance matrix to be prepared as per format and to be submitted with
the bid
• PreBid Meeting only covers technical clarifications/amplifications.
No queries seeking change in RFP or commercial terms and conditions
would be entertained
Vendor Queries
Firms Attended Pre-Bid Meeting: CCS Computers, Esconet Technologies, Wipro Ltd., PC Solutions and HP
Ser Query Decision
1 The RFP Refers to Appendix ‘C’ for
specifications, but Appendix C contains
specifications for Workstation and Blade Servers
Complete Appendix ‘c’ with
specifications of all items uploaded as
corrigendum to RFP.
2 New features for blade servers which may be
included to bring value of better virtualisation and
resource management
No changes will be made to Technical
Specifications of any item. The
specifications as per Appendix C are
final and vendors are to quote for the
same..
3 RFP is silent on the Blade Enclosure
specifications
The Specifications of Blade Enclosure
are placed at Appendix C.
4 No Specifications for other Important
components like storage and switches
Specifications of all items are placed
at Appendix C.
Vendor QueriesFirms Attended Pre-Bid Meeting: CCS Computers, Esconet Technologies, Wipro Ltd., PC Solutions and HP
Ser Query Decision
5 Different firms Suggested changes to Technical
specifications of Different Items
No Changes will be made in Technical
specifications . The technical
Specifications as per Appendix C are
final.
6 Scope of work not mentioned clearly The Scope of work for installation and
Commissioning of items is uploaded
as corrigendum to RFP.
7 Requiremnet of Civil Works not mentioned Site preparation and Civil works will
be undertaken by Indian Navy. The
site will be made ready by Indian
Navy for installation and
commissioning of items being
procured.
8 Provioining of Extra items required for
Installation / Commisioing
All extra items required for installation
and commissioning and are not part of
items being procured, will be provided
by Indian Navy (such items include
power supply sockets, electric cables,
ACs, Patch panels, I/O boxes, Fibre
optic patch cords, cat 6 cable etc.)
Compliance Matrix Format
Ser Criteria Compliance
(Yes/No)
Reasons for non-compliance Supporting document
(Page No., Para No.)
1
2
3
4
5
Thank You