34
© SCHRACK SECONET AG • M. Schwantner • B-PPT-001EN.ppt• V 2.0 Schrack Seconet Fire Alarm Systems. FIRE ALARM Schrack Seconet Fire Alarm Systems. Worldwide security.

Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

FIRE ALARM

Schrack Seconet Fire Alarm Systems.

Worldwide security.

Page 2: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

CUBUS technology

New standards in detection

Integral LAN

Examples and references

Integral IP family

MX, CX, BX

IP Applications

for Fire Alarm Systems

Overview.

BX-MDH

Door holding magnet

Page 3: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral IP system family.

Modular, decentralized structure

100% redundant system

can be TCP/IP networked

X-LINE capable: up to 16 loops or 4,000 elements per control unit

Multizone extinguishing system control panel

Compact, decentralized structure

Software redundancy

can be TCP/IP networked

X-LINE capable: up to 4 loops or 1,000 elements per control unit

Single zone extinguishing system control panel

MX CX

Page 4: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral IP BX - intelligent new 1-Loop Panel.

Interfaces 1x Loop X-LINE (max. 250 elements), 1x LAN (100Mbit-TX)

Page 5: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

B5-NET4-485 Network Module

Double security thanks to real redundancy.

Two identical systems work constantly in "Hot-Stand-By-Operation“

Not only the microprocessor structure, but all other system structures, components and parts are also duplicated

The occurrence of a fault in the active section of the system causes the system to be automatically switched over to the second side of the system and for a system fault to be indicated

Page 6: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral X-LINE.

Integral Loop Circuit 2,000 m length

128 units

X-LINE 3,500 m length

250 units

B3-DAI2

B5-DXI2

up to 250 detectors/modules

up to 3,500 m loop length

Short circuit isolator in every detector/module

Single detector addressing, single detector disablement

Page 7: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

CUBUS technology - New standards in detection.

Page 8: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Multiple Sensor Detector MTD 533.

ONE fire detector for all applications

Automatically adapts to its surrounding conditions

Mechanically and electronically backward compatible

Page 9: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

CUBUS Technology.

The detector adjusts itself automatically according to its ambient conditions

The detector monitors the ambient temperature as well as the relative increase of temperature and automatically calculates the optimal smoke sensitivity for each location.

Thanks to CUBUS technology deceptive alarms can be reduced

Page 10: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Base

Smoke chamber

Heat sensor

LED light beam

Page 11: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Case

Detector Base Connection Clip

LED visible from 360°

Measuring Chamber

Infrared LED Electronic Circuitboard

Photo diode

Temperature sensor

Page 12: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

New standards in detection.

Multisensor detectors for all applications

CUBUS technology for intelligent detection

Compliant with all new EN standards prEN 54-26:2008

Point fire detectors using carbon monoxide sensors

prEN 54-30:2009 Point detectors using a combination of carbon monoxide and heat sensors

prEN 54-31:2012 Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors

prEN 54-29:2009 Point detectors using a combination of smoke and heat sensors

Page 13: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

CMD 533X MTD 533X-S/SP carbon monoxide siren /speaker integrated

Page 14: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Green building door holding magnet BX-MDH.

Page 15: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Door holding magnet BX-MDH.

directly on loop

saves energy costs, no continuous current required

permanent magnet

integrated monitoring of the door position

Page 16: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Door holding magnets – standard installation.

Permanent Power consumption

Page 17: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

New door holding magnet BX-MDH.

Permanent Power consumption

Page 18: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

IP Applications for Fire Alarm Systems.

Page 19: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral IP Network.

Page 20: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral IP Applications - Overview.

Get informations

Operating the system

Programming

Page 21: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral over IP – Applications & Benefits.

Use of existing networks (Intranet, Internet)

Standard interfaces (LAN, IP)

Messaging: Panels send information's automatically to responsible persons

Immediate intervention of specialists possible from anywhere

Page 22: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral over IP – PC terminal devices.

RemoteMESSAGE Automatic messages from control panels to a Server and visualisation on PCs.

Integral MAIL Information: the control panels send event-based emails to recipients

Page 23: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral over IP - PC terminal devices.

Integral VirtualMAP

Virtual operating control panel on PC

IAC RemoteACCESS

Support during start-up procedure, assistance in troubleshooting, remote reprogramming

Page 24: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral over IP - PC terminal devices.

100 Mbit/s

UMTS Router with certificate

Firewall

100 Mbit/s

DSL Router with certificate

Windows PC and dongle with extension RemoteACCESS via open VPN with certificate

per DSL or UMTS

Internet

Firewall

Customer router with Internet access

Firewall

Page 25: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral over IP - Mobile devices.

indication and operation of fire alarm panels independent of location of the user

Indicates information about the current state of the system

Remote help

Push-Notifications

Geodata query

Page 26: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral over IP - Mobile devices.

100 Mbit/s

UMTS Router with certificate

Firewall

Gateway PC

100 Mbit/s

Switch

Gateway PC

Firewall

WLAN Router with certificate

Customer router/modem with Internet access

iPhone, iPad or iPod touch

APP IACmobile

www.s2service.com

Internet

Page 27: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Bank branches

Supermarkets

Gas stations

Pumping stations of pipelines

Transformer stations

Safety for tourism, small industry and unattended objects.

Page 28: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Example for protecting unattended equipment.

WWW

FIRE BRIGADE

FIRE BRIGADE FIRE BRIGADE

FIRE BRIGADE

FIRE BRIGADE

Secolog, RemoteMessage IACmobile

VirtualMap

Page 29: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral LAN – Example for shopping center.

WWW

Firebrigade

WWW

Page 30: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral LAN – Example for distributed industries.

Firebrigade

Industriestr. 67

Industriestr. 72

Industriestr. 131

Industriestr. 20

Lange Allee 24

Lange Allee 53

Benatzkygasse 2-6

WWW

Pasettistraße 76

Praterstrasse 34

Bahnhof 14

Page 31: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral over IP projects

Bulgaria: – 29 H&M shops with Integral BX

– centralized service access – Remote Message – IAC/Virtual Map, E-Mails, Internet, S2S

Turkey: – Botas Refinery

– Integral IP MX in network with existing LAN Intranet

Israel: – 80 Mizrachi bank shops with Integral BX

– Virtual Map, Remote Message, Intranet

Page 32: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Integral over IP projects

India: 186 water pumping stations with Integral BX, Remote Message, Intranet (Offer phase)

Romania: APA Nova waste water treatment Bukarest – 12 panels B6/B7 in 5 different locations – Intranet, Remote Message/E-Mail – Secolog IP with 3 clients

Page 33: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Over 6000 central units / year are delivered to projects in

Europe, Africa and Asia

Is compatible with 3 past generations of fire alarm systems

dating back to the year 1985.

Currently in the airport of Vienna approximately 59.000

detectors are integrated in a network of 76 central units.

Numbers

Page 34: Schrack Seconet Brandmeldesysteme...Schrack Seconet Fire Alarm Systems. B5-NET4-485 Network Module Double security thanks to real redundancy. Two identical systems work constantly

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

01

EN.p

pt•

V 2

.0

Schrack Seconet Fire Alarm Systems.

Experienced partners

Direct connection to “IP world” IP applications, MAIL, SMS,

Push notifications to smartphones and tablet PCs

Full Redundancy, shortcut isolator, one intelligent detector,

one system family for all different dimensions of projects

>>

Advantages for you!