Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Page 2: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 2- Division - Name – Date

Schneider Electric is the Global Leader inPre Fabricated Modular Solutions

AST leads the pre-fabricated Modular Data Center Market (>20% market share)Over 600 Data Center projects successfully executed to dateProjects deployed in over 50 countriesFirst company to build a Tier 3 multi-Container Data CenterPioneered the manufacturing of high quality purpose built containerized data centers (2001)AST customers include IT leaders including IBM, HP, Dell, and Silicon Graphics

In January 2014 Schneider Electric acquired AST Modular the global leader in pre fabricated modular and containerized and modular Data Centers

Page 3: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 3- Division - Name – Date

Schneider Has Deep Experience in Delivering Pre Fabricated Solutions

Page 4: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 4- Division - Name – Date

Product Options

Page 5: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 5- Division - Name – Date

SS Modular Rooms

Our Products Include a Wide Variety of Standard and Pre-fabricated IT Room Solutions

SS Standard ISO MDC – Non-ISO

20’ & 40’ ISO-All in one containers-Multi container parks

25’ & 45’ NON ISO-All in one modules-Contiguous IT rooms

Secure IT rooms -Indoor & Out Door -Secure and any size

Smart Shelter

Page 6: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 6- Division - Name – Date

Compact ISO All-in-One (20ft Enclosure,7Racks, UPS, PDU, Overhead DX Cooling,

Standard ISO All-in-One (40ft Enclosure, up to 19 racks, PDU, overhead DX cooling

Ruggedized Solutions for Industrial (40ft Enclosure, up to 19 racks, PDU, overhead DX cooling, Ruggedized versions available

Multi-Bay IT Modules (25ft – 40ft enclosure, Non-ISO design for more space. Cooling options - In-Row CW Perimeter CW, Air Economizer Cooling, DCIM)

Modular Room (20 x 45ft Enclosure,24 Racks, PDU, 3 Perimeter CRACs CW cooling, DCIM)

AST IT Modules

3 Types of IT Modules for Different Applications

Page 7: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 7- Division - Name – Date 7

Non-ISO design is wider, taller, deeper than container and engineered to provide a spacious, functional workspace for IT personnel

Efficient, scalable design allows for custom, multi-module configurations from 20 – 240 racks

Multiple cooling solutions for chilled water, DX and air economization (In-row, Perimeter, End-of-Row)

Robust frame design simplifies installation and ganging together

Best option for a complete configurable space.

IT Module – Non ISO ”Wide Tall & Comfortable”

Overview

Walk Through Our Demo Module Outside

Page 8: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 8- Division - Name – Date

Multi Module Designs

IT Rooms are joined together to form an “open white space” IT room

Page 9: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 9- Division - Name – Date

90kW All-in-One (40ft Enclosure,10 Racks, UPS, PDU, In-Row DX Cooling, DCIM)

110kW Single Module (40ft Enclosure, 10 racks, PDU, In-Row CW cooling, DCIM)

205kW Single Module (53ft Enclosure,14

racks, PDU, In-Row CW cooling, DCIM)

240kW Dual Module

(20 x 45ft Enclosure 22 Racks, PDU, In-Row

CW cooling, DCIM)

240kW Dual Module (20 x 45ft Enclosure,24 Racks, PDU, 3 Perimeter CRACs CW cooling, DCIM)

IT Room Modules

Base Designs – IT Modules

Page 10: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 10- Division - Name – Date

90 kW All in One Pre Fabricated Data Center (Non ISO)

Page 11: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 11- Division - Name – Date

10 Rack 90 kW N+1 “All in One” Wide Body” Pre Fabricated Data Center

Page 12: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 12- Division - Name – Date

24 NetShelter Racks

240kW cooling capacity 415V distribution

@11kW per rack (2N) Power monitoring,

management and controls

Fire detection and suppression

Staging lobby for outside isolation In-Row

Cooling Units

Aisle Containment

415 Modular Power

Distribution

Staging Lobby and Electrical

Room

2 bay, 24 Rack In-Row, 240kW shown

IT Module Detail

Page 13: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 13- Division - Name – Date

25’ 5 rack 30 kW N+1 “All in One”

Page 14: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 14- Division - Name – Date

20’ 3 rack 30 kW N+1 Data Comm Room

Page 15: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 15- Division - Name – Date

Smart Shelter™ Prefab Modular Room Example Phased Deployment View of (4)100 Rack IT Bays

Phase 1 100 Racks

Phase 2100 Racks

Phase 3

Phase 4

Gensets Chillers

Page 16: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 16- Division - Name – Date

● Expandable rooms are secure, water, dust & fire proof thermally insulated modular IT rooms.

● Rooms are built sized to any requirement.

● Installed Indoors or outdoor.● Shelters can be disassembled &

relocated.● Rooms can expanded in a clean method.● No construction construction dust or

debris affecting expansion while operating.

● Visiting customers experience a “clean room” secure IT white space.

Smart Shelter™ Secure Prefab Modular Rooms

Page 17: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 17- Division - Name – Date

Sliding Rail System

Seismic Rack Mount

Echain cable managemen

t

IT Module – ISO Shipping Container

Schneider specific features

Page 18: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 18- Division - Name – Date

250kW 20ft Enclosure with UPS, Switchgear, cooling, DCIM

500kW 40ft Enclosure with UPS, Switchgear, cooling, DCIM

1.2 MW Skid mounted, UPS, Switchgear, DCIM

Power Modules

Base Designs - Power Modules

Page 19: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 19- Division - Name – Date

Critical Output

Switchboard

Air Conditioners

500kW Symmetra

PX UPS

Primary Switchboard

Fire Suppression System

Symmetra N+1 UPS(250/500kW)

5 min Runtime Switchboard w/ integrated

ATS Power monitoring,

management and controls Environmental cooling Fire Suppression UL Listed

500kW Module

Enclosed Power Modules

Page 20: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 20- Division - Name – Date

1.2 MW Skid Shown

Allows for quick deployment within an existing building that is scalable for larger data centers.

N+1 UPS MW UPS 5 min Runtime Switchboard w/ integrated ATS Power monitoring, management and controls

Skid Mounted Power Module

Page 21: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 21- Division - Name – Date

500kW Hydronics Modules (Support 3-250kW Chillers)

1000kW Hydronics Modules (Support 3-500kW Chillers)

Chiller Skids & Enclosures Packaged Chiller, pump, and Tank with connecting piping

250kW – 1.2 MW Packaged Air Cooled Chillers - Options with and without free cooling

Ecobreeze ISO frame 50kW increments up to 400kW of total cooling capacity (DCIM)

Cooling Modules

Cooling Modules

Page 22: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 22- Division - Name – Date

AST Cooling Offer – CW & DX (Pending UL Certification)

AST added Capability

Chilled Water Block Unit – CWB 100 kW

Chilled water room cooling for prefabricated IT modules without raised floors

● Fits both ISO and Non-ISO prefab modules● Designed to operate at higher water temperatures (15C)● Top return with front supply air discharge● Humidifier and electric reheat control options

Hot Corridor Heat Exchanger– HCX 20 kW - 40 kW

Overhead cooling for prefabricated ISO IT modules

● Chilled Water or Direct Expansion● No floor space - located over the racks and hot aisle/corridor● Maintenance all done from hot aisle/corridor● Requires chilled water plant or remote condensing unit

Page 23: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 23- Division - Name – Date

AST Cooling Offer – Air Economizer

Natural Free Cooling Unit – NFC 50 kWIndirect Free Cooling for small or constrained data center spaces

● Independent operating unit● Heat Pipe heat exchanger isolating indoor and outdoor air● Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling

Options● Flexibility to have external heat rejection for mechanical cooling as required

- Chilled Water Plant or External Condensing Units

Direct Free Cooling Unit – DFC 75 kWDirect Free Cooling for small or constrained data center spaces

● Uses air directly from outside for free cooling● Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling

Options● Flexibility to have external heat rejection for mechanical cooling as required

- Chilled Water Plant or External Condensing Units

Page 24: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 24- Division - Name – Date

Utility - Australia

Healthcare - Italy Military - Europe

Education - Canada

Global References

Page 25: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 25- Division - Name – Date

IT Software Company Government Customer – US

Global Bank – Denmark Cloud Service Provider – Iceland

Global References

Page 26: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 26- Division - Name – Date

Mission-Critical Services

● Consulting and Planning – Assessment, analysis, strategic planning and O&M program development services.

● Design and Construction– Engineering, design-build and construction project management of facility expansions and new facility projects.

● Commissioning – Data center and LEED commissioning from project inception to integrating testing.

● Operations and Maintenance – Managed Services and on-site Critical Facility Management.

● Energy Management– Energy assessments, system optimization, and efficiency improvement projects.

● Alarm and Incident Management – 24x7 remote monitoring services through the Schneider International Operations Center (NOC).

Lifecycle Service Solutions

Page 27: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 27- Division - Name – Date

Design-Build Benefits

2/2012 12/2013 Schneider Design Build Outcomes

Singular Accountability/Project Ownership

Fully Integrated Project Delivery

Speed to Market – Reduced Project Timelines

Fewer Change Orders – Less Cost Overruns

Continuous Project Budgeting and Scheduling

Datacenter/Mission Critical Specific Team Skill Set

Competitively Bid All Major Cost Items

Page 28: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

28

Discussion, Questions and Answers

Scott FlemingPre Fabricated Data Center [email protected](925) 963 5468

Thank you

Page 29: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 29- Division - Name – Date 29

ISO shipping container is defined to 8ft wide and lengths of 10ft, 20ft, 40ft, and 53ft in U.S.

Containers are designed to be strong, rugged, environmentally sound and easily transportable anywhere in the world

8ft width limits usable space for hot and cold aisles. Height is also limited

Schneider has unique solutions for slide racks and flexible cable trays to allow full access to front and rear of racks to overcome space limitations

Overhead cooling units (DX and CW) are available to maximize rack space

IT Module – ISO Shipping Container

Overview

Page 30: Schneider Electric 1 - Division - Name – Date Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

Schneider Electric 30- Division - Name – Date

Pow

erIT

Spa

ceC

oolin

gOne-Size Does Not Fit All

200kW – 1.2MW

5 Racks – 200 Racks

DX – Chilled Water – Direct Air – Indirect Air