Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
1.00
LAYING OF 11/3.3 KV PVC/ XLPE/PILC CABLE OF
ALUMINIUM/COPPER CONDUCTOR OF SIZE 3 X 70 SQ. MM.
TO 3 X 400 SQ. MM., IN TRAYS, STRUCTURES, PIPES,
POLES, TRENCHES ETC OF ANY SIZE.
MR 1800
2.00LAYING OF 1100V GRADE PVC/ XLPE/PILC CABLE
ALUMINIUM/COPPER CONDUCTOR IN TRAYS, STRUCTURES,
PIPES, POLES, TRENCHES ETC OF FOLLOWING SIZES.
2.01Cable up to & including 3/4x25mm2,Control cables & Telephone
Cables of all sizes with clamping etc.MR 1000
2.02Same as 2.00 but above 3/4x25mm2 to & including 3/3.5x70mm2
with clamping etc.MR 50
2.03Same as 2.00 but above 3/3.5x70mm2 to & including
3/3.5x185mm2 with clamping etc.MR 400
2.04Same as 2.00 but above 3/3.5x185mm2 to and including
3/3.5x400mm2 with clamping. MR 475
3.00LAYING OF 11/3.3 KV PVC/PILC/XLPE ARMOURED POWER
CABLE OF ANY SIZE UNDER THE GROUND INCLUDING
SUPPLY OF BRICKS AND SAND.
MR 650
4.00LAYING OF 1.1 KV PVC/PAPER INSULATED / ARMOURED
POWER CABLE UNDER THE GROUND INCLUDING SUPPLY
OF BRICKS AND SAND IF REQUIRED OF FOLLOWING SIZES:-
4.01Cable up to & including 3/4 x 50 mm2, Telephone cable/ control
cable of any size MR 90
4.02 -do- but successive cables. MR 50
NFL SUPPLY
(To be submitted in Envelope-III)
Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year 2016-17
(Section-A) Cable Laying Jobs.
Rate Amount
Cable and Cable
Glands
Cable and Cable
Glands
S.No Description Unit Quantity
Signature of issuing Authority Page 1 of A Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
NFL SUPPLY
Rate Amount
S.No Description Unit Quantity
4.03 Above 3/4 x 50mm2 to & including 3/3.5x185mm2 MR 50
4.04 -- do- but successive cables MR 50
4.05 Above 3/3.5x185mm2 to & including 3/3.5x400mm2. MR 50
4.06 -- do- but successive cable. MR 50
5.00REMOVING, ROLLING & SHFTING TO MAIN/SITE STORE AS
PER REQUIREMENT, OF 1.1KV/ 3.3KV/ 11KV PVC/ PILC/ XLPE
UNDERGROUND CABLE OF SIZE:
5.01Up to & including 3/4x 70mm2, Control Cable/ Telephone cable of
any size MR 50
5.02 -- do- but successive cables. MR 50
5.03 All sizes Above 3/3.5x 70mm2 MR 50
5.04 --do- but successive cables. MR 50
6.00REMOVING OF 1.1KV/ 3.3KV/ 11KV PVC/ XLPE/ PILC CABLE
FROM TRENCHES, TRAYS, PIPES OR STRUCTURES OF
SIZE:
6.01Up to & including 3/4x70mm2, Control Cable/ Telephone cable of
any size MR 50
6.02 All sizes Above 3/3.5x70mm2 MR 50
Cable and Cable
Glands
NIL
NIL
Signature of issuing Authority Page 2 of A Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
NFL SUPPLY
Rate Amount
S.No Description Unit Quantity
7.00
REMOVING OF 1.1KV/ 3.3KV/ 11KV UNDERGROUND CABLE
AND LAYING OF NEW OR EXISTING CABLE IN ITS PLACE
INCLUDING SUPPLY OF BRICKS AND SAND IF REQUIRED OF
SIZE:
7.01Up to & including 3/4x70mm2, Control Cable/ Telephone cable of
any size MR 50
7.02 -- do- but successive cables. MR 50
7.03 All sizes Above 3/3.5x70mm2 MR 50
7.04 -- do- but successive cables. MR 50
8.00CABLE JOINTING OF EXISTING UNDERGROUND CABLES OF
FOLLOWING SIZES:-
8.01 2/3/4 core Cable upto 70 sq.mm. No. 1
8.02 2/3/4 core Cable exeeding 70 sq.mm. Upto 240 sq.mm. No. 1
8.03 2/3/4 core Cable exeeding 240 sq.mm. Upto 400sq.mm. No. 1
Total
Cable and Cable
Glands
Jointing Kit,
Thimbles
Cable and Cable
Glands
Signature of issuing Authority Page 3 of A Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
1.00
SUPPLY, FIXING, REPLACEMENT OF VARNISHED TEAK
WOOD BATTEN / ISI MARKED PVC CASING CAPING
INCLUDING SUPPLY OF LINK CLIPS, PLASTIC SLEEVES,
SCREWS/ NAILS, U & T SHAPE BENDS ETC OF FOLLOWING
SIZES:-
1.01 12mm x 12mm MTR 360
1.02 19 x12mm MTR 625
1.03 25mm x12mm MTR 350
1.04 38mm x12mm MTR 30
1.05 50mm x 12mm MTR 5
2.00SUPPLY & LAYING OF 25MM CONDUIT IN BRICK
MASONARY/RCC WALL OR OVER THE WALL/RCC COLUMN
ETC.
2.01 PVC conduit. 2.0 mm thickness. MTR 230 NIL
2.02 MS conduit. 1.6 mm thickness. MTR 10 NIL
3.00
Supply, laying and connection of 2 x 6 sq mm flat PVC insulated
PVC sheathed copper conductor, 1100V grade cable alongwith
Supply & Laying/ Termination of 8 SWG GI Wire duly clipped with
Aluminium Clips.
MTR 30 NIL
3.01
Supply, laying and connection of 2x 10 sq mm flat PVC insulated
PVC sheathed aluminium conductor, 1100V grade cable
alongwith Supply & Laying/ Termination of 8 SWG GI Wire duly
clipped with Aluminium Clips. .
MTR 50 NIL
NIL
Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year 2016-17
(Section-B) Wiring Jobs.
QuantityUnit DescriptionS.No
Rate Amount
NFL SUPPLY
Signature of Issuing Authority Page 4 of B Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words QuantityUnit DescriptionS.No
Rate Amount
NFL SUPPLY
3.02Supply, laying and connection of 2x 10 sq mm flat PVC insulated
aluminium conductor, 1100V grade cable alongwith Supply &
Laying/ Termination of 8 SWG GI Wire in PVC conduit pipe.
MTR 40 NIL
4.00
Providing of over- head 2 core PVC short wire cable / draw wire
copper conductor 4/0.3 mm alongwith 14 SWG G.I wire, clipping
sagging on the existing supports on poles or building tops.This
includes supply of G.I wire clips and clamps where-ever required
but excludes supply of cables.
MTR 50 Cable
5.00Stringing / removing of overhead G.I telephone wires size 12 / 14
SWG or telephone wires including binding and sagging etc.
wherever required.
MTR 50 Telephone Wire
6.00Attending and rectification of overhead telephone faults to the
satisfication of Engineer Incharge.Nos 50 NIL
7.00Supply, installation, testing and commissioning of Earth Pit station
with 75 mm dia, 3 mtr long G.I pipe and connected civil masonary
work with two nos.RCC slabs of size 1000x500mm
Nos 5 NIL
8.00Laying/Removing of 25mm x3mm to 50mm x 6mm G.I / Aluminum
earthing strip directly in the ground/ on structure, walls, trays etc.
including termination of earthing connection
MTR 20 Earthing strip
9.00 EARTHING WIRE
9.01Laying/ Termination/ Dismantling of 6/8 SWG GI/AL Wire on
existing RCC poles or other structure/ wall/ underground etc..MTR 50 Earth Wire
9.02Supply & Laying/ Termination of 8 SWG GI Wire on existing RCC
poles or other structure/ wall/ underground etc..MTR 20 NIL
10.00Maintenance of earth pit such as cleaning of connections,
checking and tightening nuts/bolts, putting salt, watering etc and
recording of pit / grid resistance values with earth tester.
Nos 210 NIL
11.00
Supply and fixing/Replacement of MS board 2mm thick/ varnished
teak wood board free from crack and knots on flush mounting or
double hinged on surface mounting if required, of following sizes
without sunmica sheet.
11.01 175x100x50mm(7''x4''x2'') Nos 190 NIL
Signature of Issuing Authority Page 5 of B Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words QuantityUnit DescriptionS.No
Rate Amount
NFL SUPPLY
11.02 250x200x50mm(10''x8''x2'') Nos 50 NIL
11.03 375x300x50mm(15''x12''x2'') Nos 5 NIL
11.04 450 x 300 x 50mm(18''x12''x2'') or (18"x11"x2") Nos 5 NIL
11.05 250 x 300 x 50mm(10''x12''x2'') Nos 2 NIL
11.06 100 x 100 x 50 mm(4"x4"x2") Nos 50 NIL
12.00Supply and fixing of white glazed sunmica sheet 3mm thick
suitable for boxes of following sizes.The job also includes cutting
of sheet and fixing of switches,sockets, MCB as required at site.
12.01 175x100x50mm(7''x4'') Nos 200 NIL
12.02 250x200x50mm (10''x8'') Nos 70 NIL
12.03 375x300x50mm(15''x12'') Nos 5 NIL
12.04 100x100x50 (4"x4"x) Nos 70 NIL
12.05 Sheets of various sizes as per the requirement at site. SQ.FT. 45 NIL
13.00
Supply fixing, mounting on existing board and wiring up with
suitable size and quality of wire, piano type / tumbler Anchor /
SSK make only ISI marked switch / socket / batten holder / ceiling
roses / push button for call bells etc. as required as detailed below
:-
NIL
13.01 5 Amp piano type / tumbler switch. Nos 1250
13.02 5 Amp piano/ tumbler typeCall bell push button. Nos 35
13.035 Pin 5 amp flush/surface mounted Socket/ telephone socket &
top.Nos 500
NIL
Signature of Issuing Authority Page 6 of B Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words QuantityUnit DescriptionS.No
Rate Amount
NFL SUPPLY
13.04 15 Amp piano type / tumbler Switch Nos 380 NIL
13.05 5 pin 15 Amp/ 5-15A combined flush/surface mounted Socket. Nos 310 NIL
13.06 Angle holder / batten holder / Pendant holder etc. Nos 455
13.07 Ceiling Rose 5 Amps 2 plate. Nos 105
13.08Supply and fixing of superior quality varnished teak wood round
block free from crack & knots 75mm dia.Nos 140
14.00 Light point /ceiling mounted type light fittings
14.01Replacement of chokes, holders, condensers, starter/ base,
Electric bell etc. and rectification of any fault.Nos 15
All required
Meterial except
hardware.
14.02 Replacement of complete lighting fixture. Nos 5
All required
Meterial except
hardware.
15.00Cleaning of tube light fixture /ceiling fans installed in official
/residential buildings including removing and fixing of louvres after
cleaning of fan blades.
Nos 115 NIL
16.00
Replacement of all types / sizes / rating of iron clad double pole
switches / iron clad distribution board / single pole neutral (SPN)
switches / ICTP switches including connection etc. and rectification
of fault.
Nos 5
All required
Meterial except
hardware.
17.00
Supply / laying / rewiring and termination of single core PVC
insulated sheathed copper conductor wire of following sizes on the
existing teak wood batten/PVC casing caping ISI mark /conduit
incluiding supply of wiring clips, M.S. screws, nails, U & T bends
etc.
17.01Single core PVC insulated sheathed copper conductor wire of size
1.5 sq mm.MTR 2890
17.02Single core PVC insulated sheathed copper conductor wire of size
4.0 sq mm.MTR 1865
NIL
NIL
Signature of Issuing Authority Page 7 of B Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words QuantityUnit DescriptionS.No
Rate Amount
NFL SUPPLY
17.03Two core PVC insulated sheathed copper conductor wire of size
2.5 sq mm.MTR 15 NIL
18.00
Supply, laying/replacement of single core PVC covered copper
wire on the existing teak wood batten /PVC casing caping ISI
mark/conduit incluiding supply of wiring clips, M.S. screws, nails, U
& T bends etc.
18.01
Supply / laying / rewiring and termination of single core PVC
insulated copper conductor wire of size 1.5 Sq. mm. on the
existing teak wood batten/PVC casing caping ISI mark /conduit
incluiding supply of wiring clips, M.S. screws, nails, U & T bends
etc
MTR 15 NIL
18.02
Supply, laying/replacement of PVC covered copper earth wire of
single core, size 18 SWG on the existing teak wood batten /PVC
casing caping ISI mark/conduit incluiding supply of wiring clips,
M.S. screws, nails, U & T bends etc.
MTR 1340 NIL
19.00
Supply, laying and termination of PVC insulated PVC sheathed
copper conductor wire/telephone cable on teak wood batten after
removing of existing wiring and battens including supply of T .W
battens/PVC pipe, wiring clips, M.S. screws, nails etc.
19.01 Telephone cable of size 2 x 1.5 sq mm. MTR 100 NIL
19.02 Single core PVC insulated copper conductor wire of size 6 sq mm. MTR 95 NIL
20.00Supply & replacement of miniature S.P. circuit breakers of 16A/
25A of Standard/Sigma/Siemens make.NO. 5 NIL
21.00Dismantalling of electrical fitting, wiring, ceiling fan, energy meter
and TW boards, main service wire and its pipe etc. from quarters
and returning the same in NFL store.
QTR. 5 NIL
22.00
Erection of poles / street light tubular or RCC poles /lighting mast
and muffing the same with cement concrete including supply of
required quantity of sand, concrete and cement.
22.01 Up to height of 4 Mtr. Nos 5
22.02 Above 4 Mtr. & up to height of 8 Mtr. Nos 5
22.03 Above 8 Mtr.. Nos 5
street light tubular or
RCC poles /lighting
mast
Signature of Issuing Authority Page 8 of B Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words QuantityUnit DescriptionS.No
Rate Amount
NFL SUPPLY
23.00
Dismentaling /removing of poles / street light tubular or RCC poles
/lighting mast including back filling of earth and levelling of ground
etc. and transportation of removed poles and its associated
material to the NFL stores.
23.01 Up to height of 4 Mtr. Nos 5
23.02 Above 4 Mtr. & up to height of 8 Mtr. Nos 5
23.03 Above 8 Mtr.. Nos 5NIL
24.00
Replacement of aluminium /M.S. Junction Boxes of size maximum
300mm. x 300 mm.on wall /hieghts/ structures on peripheral road
side including the supply of Cable glands and thimbles by the
contractor.
Nos 10
Junction Box
25.00
Replacement of cable glandsand thimbles of appropriate size,
reglanding & termination for light fitting's junction boxes on
hieghts/structures on peripheral roads.
Nos 10
Required Cable
Gland & Thimble
26.00
Installation of 16 Amp metal clad main rewirable switch fuse unit
250V/ MCB box (fitted with 6 no. 1 pole MCB's) including drilling of
holes on the board and connection as required.
Nos 75
Required Switch
Fuse Unit
27.00
Installation, connections, testing and commissioning of TPN switch
fuse unit/ switch socket rating upto 100 Amps., the supply of
required fabrication material and paint shall be in the contractor's
scope.
Nos 10
Required Switch
Fuse Unit
28.00Supply and replacement of complete fuse base & carrier of
15A/30A on existing boards /cut-out in boxes and retermination.
28.01. Complete porcelain kit kat fuse 15A/30A and neutral links. Nos 30Nil
28.02Complete Bakelite moulded fuse base & carrier 15A/30A including
connector, 4-way, 16A.Nos 5
Nil
29.00
Supply and fixing of 2mm thick M.S or aluminium junction box
covers of size 175mm x 100mm on the wall after drilling and
tapping of existing junction box holes.
Nos 5
Nil
NIL
TOTAL
Signature of Issuing Authority Page 9 of B Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
1.00 Installation of new or replacement of old 1 X 40 W / 2x20 W /
4x20 W/ 2x40 watt Fl.fittings or 70/150W/250W Sodium
vapour Lamp Fitting or 125 W/250 W HPMV lamp or
60/100/300/500W Weather Proof fittings or 35 W sodium
vapour dust proof fittings. For Installation of new lighting
fixture, fabrication, supply, fixing of GI brackets and clamps if
required is in contractor's scope and shall be paid separately.
Nos 1430 Required
Fixture
About 143 semiskilled
mandays & 143 unskilled
Mandays are required for
execution of job
2.00 Complete overhauling of all kind of flame proof light fitting
including 2x20W /2x40Wflourescent tube or 125 W /250W
HPMV and 150W Sodium Vapour watt flame -proof light
fittings and its control gear box, F.P. Junction box,
replacement of defective parts, cleaning, painting,and bringing
back the light fitting in working order.The scope will include
maintainance of F.P. lighting sub distribution board and
replacement of MCB if, required.
Nos 1460 Defective
Component
of light fittings
including
J.B., MCB.
About 292 semiskilled
mandays & 292 unskilled
Mandays are required for
execution of job
3.00 Complete overhauling of 2x40 watt Fl .tube dust proof,
industrial type/decorative type light fitting or 1x125 W/1x250
W HPMV or 55/70/150W/250W Sodium vapour and its control
gear box, replacement of defective patrs, cleaning,
painting,and bringing back the light fitting in working order.
Nos 5860 Defective
Component
of light fittings
About 586 semiskilled
mandays & 586 unskilled
Mandays are required for
execution of job
4.00 Installation /replacement /removal of fault in the following dust
proof fixures
4.01 Installation /replacement of 2/3/4 way Junction Boxes. Nos 360 Junction Box About 45 semiskilled mandays
& 45 unskilled Mandays are
required for execution of job
4.02 Replacement of defective MCB in the lighting sub-distribution
board.
Nos 480 MCB About 60 semiskilled mandays
& 60 unskilled Mandays are
required for execution of job
4.03 Installation /replacement of 1 Ph./3 Ph.metalic power plug
including repair /fabrication of fixing arrangement.
Nos 240 Required
Power plug
About 30 semiskilled mandays
& 30 unskilled Mandays are
required for execution of job
Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year 2016-17
(Section-C) Lighting and other jobs.
RemarksNFL
SUPPLY
Rate AmountS.No Description Unit Quantity
Signature of Issuing Authority Page 10 of C Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
RemarksNFL
SUPPLY
Rate AmountS.No Description Unit Quantity
4.04 Removal of circuit/ No light fault in the lighting circuit which
feed more than 2 No. Light fittings from a junction box/D.B..
Nos 2560 Nil About 128 semiskilled
mandays & 128 unskilled
Mandays are required for
execution of job
4.05 Rectification of fault and replacement of its components
including general cleaning, if required, of aviation light fixtures
mounted on the top of the chimneys, flare stack, prilling tower,
gas vessels etc.
Nos 100 Defective
Component
About 20 semiskilled mandays
& 20 unskilled Mandays are
required for execution of job
5.00 Replacement of Any or more accessories i.e. tube rod/lamp
/starter /choke /condenser /holder/glass/ wire guard gasket /
starter holder / lamp holder/rectification of circuit fault in light
fittings such as 2 x20W, 2 x 40W tube rod fittings, or in
Incandenscent Lamp 35W/60W/100W/200W/300W on
hieghts/ structures on peripreral roads/industrial fittings after
necessary checking.
Nos 9360 Defective
Component
About 312 semiskilled
mandays & 312 unskilled
Mandays are required for
execution of job
6.00 Replacement of fused lamps/accessories i.e. choke, ignitor &
Es/ Bc cap holders etc. in various type of fitting up to 400 W
HPMV / HPSV or 500W/1000W Halogen light fittings installed
on poles/watch towers /buildings / structures/on peripheral
roads after checking and rectification of circuit fault.
Nos 2400 Required
Lamp,
Holder,
choke, ignitor
etc.for
HPMV/SV
lamps
About 80 semiskilled mandays
& 80 unskilled Mandays are
required for execution of job
7.00 Temporary installation & removal of flood lights, It includes
laying of circuit wiring, preparation of holders for lamps, fixing
of lamps, associated switchgear.
NO. 1470 Required
Material
About 49 semiskilled mandays
& 49 unskilled Mandays are
required for execution of job
8.00 Cleaning of glass covers and reflectors of HPMV lamp fittings
/sodium vapour lamp fittings of 18W/35W/70W to1000 Watt
on towers/hieghts/structures on peripheral roads.
Nos 1680 Nil About 42 semiskilled mandays
& 42 unskilled Mandays are
required for execution of job
9.00 Digging of a earth for locating /repairing of cable faults & back
filling of the earth after clearing the fault.
Cubic
MTR
690 NIL About 23 semiskilled mandays
& 23 unskilled Mandays are
required for execution of job
10.00 Fabrication of wooden former for rewinding of motors of all
sizes
NO. 48 Required
material
About 12 semiskilled mandays
are required for execution of
job
Signature of Issuing Authority Page 11 of C Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
RemarksNFL
SUPPLY
Rate AmountS.No Description Unit Quantity
11.00 To make former of taxolite sheet for rewinding of
transformers/Relay coils, contactor coils up to 6" width.
NO. 40 Required
material
About 10 semiskilled mandays
are required for execution of
job
12.00 Fabrication of wooden boards for electrical installation of 4"*4"
sizes.
NO. 36 Required
material
About 12 semiskilled mandays
are required for execution of
job
13.00 Fabrication of terminal plates for any rating of motors. NO. 40 Required
material
About 10 semiskilled mandays
are required for execution of
job
14.00 To make motors slot wedges of bamboos as well as of
bakelite of different HP motors.
SET 115 Required
material
About 23 semiskilled mandays
are required for execution of
job
15.00 Replacement of worn out rubber sealing gaskets for different
H.T & L.T. panels in factory area.
NO. 690 Required
material
About 69 unskilled Mandays
are required for execution of
total qty.
16.00 Replacement of cable trays/racks including handling and
reclamping / dressing of cables.
MR. 240 Cable
trays/racks
About 16 semiskilled mandays
& 16 unskilled Mandays are
required for execution of total
job.
17.00 Replacement of Lighting arrestor rods including connection
with Earthing.
NO. 90 GI strip/
conductor,
Insulators
and Clamps
etc.
About 9 semiskilled mandays
& 9 unskilled Mandays are
required for execution of total
job.
18.00 Installation/ Replacement/ Removal/Readings of Energy
meters single/three phase
18.01 Fixing of Energy meters single/three phase including making
neccessary fixing arrangements and connection etc.the job
includes proper carriage of energy meters from main store/site
store/workshop to the site.
NO. 235 Energy Meter About 47 semiskilled mandays
are required for execution of
job
18.02 Replacement of Energy meters single/three phase. It
including disconnection, reconnections, recommisioning as
required and proper carriage of energy meters to and from
main store/site store/workshop (Old and removed energy
meters are to be returned to NFL site store) .
NO. 290 Energy Meter About 58 semiskilled mandays
are required for execution of
job
18.03 Removal of Energy meters single/three phase after
disconnection and taping of naked wires.
NO. 85 Nil About 17 semiskilled mandays
are required for execution of
job
Signature of Issuing Authority Page 12 of C Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
RemarksNFL
SUPPLY
Rate AmountS.No Description Unit Quantity
19.00 Recording of monthly readings of Energy meters in residential
quarters, markets, religious places, official buildings in
township and construction colony.
NO 43650 Nil About 291 unskilled Mandays
are required for execution of
total qty.
20.00 Carriage of assorted material, tools, tackles, various electrical
items up to 40 Kg. within the plant area.
NO. 4608 Nil About 144 unskilled Mandays
are required for execution of
total qty.
21.00 Carriage of assorted material, tools, tackles, various electrical
items up to 40 Kg. from one Plant to another.
NO. 2000 Nil About 80 unskilled Mandays
are required for execution of
total qty.
22.00 Shifting of Drums as follows:
22.01 Shifting of 200 Ltr. Drum filled with transformer oil / lube oil
from one place to another place within the NFL premises. Half
drum or less than half shall be considered as half and more
than half shall be considered as one drum.
NO. 280 Nil About 7 unskilled Mandays are
required for execution of total
qty.
22.02 Shifting of 200 Ltr. empty Drum from one place to another
place within NFL premises.However the carrier shall be
arranged by NFL.
NO. 120 Nil About 3 unskilled Mandays
are required for execution of
total qty.
23.00 Filling of oil from oil drum to any vessel / Electrical equipment
with the help of mannual / electrical operated pump. (It will
include laying of cable and its connection to the electrical
pump if required.)
Ltr. 9350 Nil About 110 unskilled Mandays
are required for execution of
total qty.
24.00 Shifting of motors within the Plant of all sizes. NO. 960 Nil About 64 unskilled Mandays
are required for execution of
total qty.
25.00 Shifting of motors from plant to Workshop or vice versa of all
sizes.
NO. 810 Nil About 54 unskilled Mandays
are required for execution of
total qty.
26.00 Carriage and placement of ladders A type/ordinary of
following sizes from one plant to another Plant for maint. job
as per instructions of Engineer-in-charge.
26.01 Ladder upto 12 feet length. NO. 3500 Nil About 70 unskilled Mandays
are required for execution of
total qty.
26.02 Ladder more than12 feet upto 18 feet length. NO. 1050 Nil About 35 unskilled Mandays
are required for execution of
total qty.
TOTAL
Signature of Issuing Authority Page 13 of C Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
1.00 Installation, testing, commisioning including carriages of new ceiling
fans/cabin fan at site.This includes installation of regulator and
earthing of the same.
Nos 5
Ceiling Fan,
Regulator
2.00 Removal of ceiling fan/cabin fan including carriage of ceiling fans
from site to workshop/ mainstores as required & providing of
identification tags on the fan.
NO. 25
Nil
3.00 Refixing of ceiling fans/cabin fan including connection & satisfactory
trial run including carriage of ceiling fans from site W/Shop/Main
Stores to site as required.
NO. 10
Nil
4.00 Repair/Replacement of ceiling fan regulator. Nos 135Ceiling Fan
Regulator
5.00 Overhauling of ceiling fans/exhaust fans/cabin fan including greasing
& replacement of bearings & its satisfactory trial run. Consumable
like diesel, mobile oil and split pins are to be supplied by the
contractor.
NO. 395 Bearing/Bushes
6.00 Checking and rectification of ceiling fan/cabin fan faults,
replacement of split pin, in regulator, wiring, including tightening of
connection, switch and rubber reels wherever required. Supply of
split pins will be in the contractor scope.
Nos 450
Nil
7.00 Supply and replacement of defective G.I.rod of different size for
ceiling fans, 25cm to 75cm as required including threading and
drilling of hole for split pins.
Nos 5
Nil
8.00 Supply and replacement of bushes for ceiling /exhaust fans/cabin
fan.Nos 5
Nil
9.00 Supply and replacement of shaft for ceiling /exhaust fans/cabin fan. Nos 5
Nil
S.NoDescription
Unit
Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year 2016-17
(Section-D) Misc. Jobs.
QuantityNFL SUPPLY
Rate Amount
Signature of Issuing Authority Page 14 of D Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
S.NoDescription
Unit QuantityNFL SUPPLY
Rate Amount
10.00 Supply & replacement of electronic regulator of S.S.K./ Polar/
Leader(As required at site) make.The job also includes return of old
& removed regulator to site Stores.
NO. 5
Nil
11.00 Painting of ceiling /exhaust fans/cabin fan includung supply of paints
of superior quality . Nos 50
Nil
12.00 Installation & commissioning of exhaust fan of following size without
louvers/shutters on existing wall openings including grouting of
bolts/supports.
12.01 Exhaust fan 1 Ph, 230V upto size 300/450 mm at any height. NO. 5Exhaust fan
12.02 Exhaust fan 3 Ph, 440V size upto 600 mm at any height. NO. 5
Exhaust fan
13.00 Removal of exhaust fan of following size and carriage of fan to the
store.
13.01 Exhaust fan 1 Ph, 230V upto size 300/450 mm at any height. NO. 5 Nil
13.02 Exhaust fan 3 Ph, 440V size upto 600 mm at any height. NO. 5 Nil
14.00 Installation of louvers/shutters for exhuast fan. NO. 5 Louvers/shutters
15.00 Installation & commissioning of air circulator fans upto 600 mm.
sweep 1 ph/3 Ph. including fixing of its regulator/starter at operating
level and cable termination. It also includes carriage from main
store/site store/workshop.
NO. 5 Air circulator
fan, Regulator/
starter
16.00 Disconnection / Removal of air circulator fans upto 600 mm. Sweep
1 Ph./3 Ph. It includes carriage of fan to the site store/workshop.NO. 5 Nil
17.00 Overhauling of air circulator fans / exhaust fans including removal,
greasing ,replacement of bearings, cleaning, refixing in its position
giving its satisfactory trial run.
NO. 5 Bearing/Bushes
18.00 Supply, replacement of heater element/ thermostat of geysers/
heat convectors/ auto cloves/ boilers/ sterlizers/ inocculator of
different makes & ratings and rectification of faults as given below:-
Signature of Issuing Authority Page 15 of D Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
S.NoDescription
Unit QuantityNFL SUPPLY
Rate Amount
18.01 Supply and replacement of 1.0 K.W element. Nos 5
18.02 Supply and replacement of 1.5K.W element. Nos 5
18.03 Supply and replacement of 2.0 K.W element. Nos 20
18.04 Supply and replacement of 3.0 K.W element. Nos 1 Nil
18.05 Supply and replacement of 6.0 KW element. Nos 1
18.06 Supply and replacement of heater elements of all type of heat
convectors. Nos 2
18.07 Supply and replacement of thermostat of temperature range of 30° C
to 85° C.Nos 15
18.08 Rectification of faults including replacement of internal connection
leads, supply leads and 15 Amp 3 pin plug top. Nos 28 3-core supply leads
and 15 Amp 3 pin
plug top.
18.09 Attending water leakage in geysers, tanks and waterline after
removing its insulation gass wool. Reassemling after repair, fixing it
on position at site
Nos 5 Nil
19.00 Supply, replacement of heating elements, rotary switches and
brass pins & insulator for heaters and hot plates of different makes &
ratings and rectification of faults as given below:-
19.01 Supply and replacement of 1000 watt 10'' (25 cms) long heating rod
for Rod type room heater.Nos 5 Nil
19.02 Supply and replacement of 1000 watt 12'' (30cms) long heating rod
for Rod type room heaterNos 5 Nil
19.03 Supply and replacement of 750 watt heater element with ceramic
bowl for bowl type heater.Nos 5 Nil
19.04 Supply and replacement of 1000watt /2000 watt dual wattage hot
plate element.Nos 10 Nil
Nil
Nil
Signature of Issuing Authority Page 16 of D Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
S.NoDescription
Unit QuantityNFL SUPPLY
Rate Amount
19.05 Supply and replacement of 15 Amp rotary switches (complete
assembly) for hot plates.Nos 5 Nil
19.06 Supply and replacement of Brass pins with double brass nuts and
porcelain male and female insulator for hot plate heaters.Nos 10 Nil
19.07 Rectification of faults including replacement of internal connection
leads, supply leads, 15 Amp 3 pin plug top, tumblar/piano type
switch, brass pins with double brass nuts, porcelain male and
female insulators.
Nos 5 3-core supply
leads and 15
Amp 3 pin plug
top. 20.00 Fabrication, Painting and fixing of MS supports, brackets, clamps,
structure and sheds/canopies etc.
20.01 Supply of material & fabrication of G.I. Brackets, clamps and fixing in
position at site. Kg. 5 Nil
20.02 Fabrication of MS supports, brackets, clamps and structure etc. and
fixing in position at site. Kg. 5 Required fabrication
material i.e. M.S.
angle, flats, pipes
etc.
20.03 Supply of 18 SWG GI sheet and its fabrication for inclined
sheds/canopies on electrical equipment i.e. motors/junction boxes
etc. Fabrication of M.S. angle /flat/Aluminium/GI sheet/ shall be paid
separately.
Sq
Mtr.
5 Required fabrication
material i.e. M.S.
angle, flats, M/S/
/Aluminium sheet
etc.
21.00 Painting of steel tubular poles including brackets with base of red
oxide primer and two coats of aluminium paints. Paint to be supplied
by the contractor.
Nos 80
21.01 Painting of Terminal boxes, pillar boxes, Cross Arms, power and
telephone distribution boxes with base of red oxide primer and two
coats of synthetic enamel paint. Paint to be supplied by the
contractor.
Nos 10
21.02 Writing of numbers and letters with red /black paint for numbers and
alphabets of size 25mm to 50mm on poles, ceiling fans, panels as
required on appropriate size of base in white paint. Paint to be
supplied by the contractor.
Nos 10
NIL
Signature of Issuing Authority Page 17 of D Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
S.NoDescription
Unit QuantityNFL SUPPLY
Rate Amount
22.00 Installation of new Telephone Distribution Boxes. This includes
fabrication of suitable MS frame, grouting of the same at site.
22.01 5/10/20 pair telephone DBs. NO 1DBs, Cable
Glands
22.02 50/100 pair telephone DB's. NO 1DBs, Cable
Glands
23.00 Replacement of telephone Distribution Boxes including cable
termination of incoming and outgoing telephone cables.
23.01 5/10/20 pair telephone DBs. NO 5DBs, Cable
Glands
23.02 50/100 pair telephone DBs. NO 5DBs, Cable
Glands
24.00 Maintenance of Telephone Distribution Boxes.
24.01 5/10/20 pair Telephone DBs. NO 30
NIL
24.02 Maintenance of 50/100 pair Telephone DBs including cleararance of
9 sq. mtr. area of wild growth around the telephone DBs. NO 20
NIL
TOTAL
Signature of Issuing Authority Page 18 of D Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
1.00
Erection of overhead ACSR/earth conductor on the
existing poles.This includes shifting of material from
Main stores to site, sagging, stringing and binding
with insulators.
1.01
LT lines including replacement of defective
insulators, D-shackles, bolts, aerial fuse
etc.whereever required.
MTR. 10000 ACSR/earth
conductor
1.02 11 KV H.T. poles. MTR. 1240 ACSR/earth
conductor
2.00
Removal of existing overhead copper conductor
/ACSR / earthconductor of max. dia equivalent to
6/1/4.09mm conductor from L.T/HT line poles.This
includes removing, re-rolling, weighing and shifting
for returning to Main Stores from site.
MTR. 10000 NIL
3.00Dismantlling and removing of different sizes of
earthwire on the existing poles including
transportation from site to Main Stores.
MTR. 8000 NIL
4.00Fabrication, installation and binding of Aluminium/
G.I. Guards on L.T/H.T overhead lines including
replacement of demaged existing guards.
NO. 111
Fabrication Material,
Porcelain/ceramic
insulator reels of line
guards
5.00
Supply & installation of G.I. Stay wire set size 7/1.54
mm complete with all accessories stay rod Anchor
plate, thimbles,stay clamp turn buckle and porcelain
insulator etc.
NO. 1 NIL
6.00Erection of stranded G.I. Stay wire of size 7/12
SWG. Or 7/1.54 mm. MTR. 13 NIL
7.00Erection of shackle/LT Pin insulators on the existing
cross arms including supply of G.I. Bolts, nuts,
washers.
7.01 Shackle insulators NO. 7Shackle
Insulator.
Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year 2016-17
(Section-E) Overhead Line Jobs.
S.No Description Unit NFL SUPPLY Quantity
Rate Amount
Signature of Issuing Authority Page 19 of E Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In wordsS.No Description Unit NFL SUPPLY Quantity
Rate Amount
7.02 LT Pin insulators. NO. 6 Pin Insulator.
8.00Replacement/Repiar of wooden / FRP cross arms
with FRP cross arms after removing of existing
overhead condutor.
NO. 14 Cross arms
9.00Erection of top hamper with its supporting clamps,
fixing of existing top insulators & erection of existing
overhead conductor on it.
NO. 15
Top-hampers &
supporting
clamps
10.00Fixing of F.R.P/wooden spacer on L.T. overhead
lines. NO. 31
F.R.P/wooden
spacer
11.00
Complete maintenance of 11 KV gang operated
switch, jumper insulators, lightnening arrestor
including all accessories, repair or rectification or
replacement of any part of above. This includes
cleaning of insulators and contacts thoroghly. Supply
of spares, if required, is NFL's responsibility.
NO. 7 G.O. Switch
12.00Checking, cleaning & tightening of overhead line
insulators, PG clamps/ binding wire and guard wires
on the poles of LT/ HT overhead lines.
NO. 32copper/ACSR
conductor
13.00
Replacement of the jumpers of any size of LT/HT
overhead lines, which includes preparing of jumpers
of copper/ACSR conductor or cable including
binding. (supply of material is in NFL scope.
However fabrication of jumper is in the scope of the
contractor).
NO. 65copper/ACSR
conductor
14.00
Stringing (Resagging) of conductors of LT/ HT
overhead lines irrespective of its type or shield/
guard/ neutral/ earth wire but having a span of 60
meters maximum between two poles.
SPAN 9 NIL
15.00Supply & fixing of porcelain aerial fuses of 30 A on
L.T overhead lines including connections with
appropriate jumpers .
NO. 2 NIL
16.00Replacement of lightening arrestors including
disconnection and connection on 11 KV & L.T.
overhead lines.
NO. 2
GI strip/
conductor,
Insulators and
Clamps
TOTAL
Signature of Issuing Authority Page 20 of E Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words NFL SUPPLYRemarks
1.00
Cleaning of cable trenches of various sizes from
450 mm wide x 600 mm deep to 1000 mm wide x
1250 mm deep containing MS angle/support
including cleaning, scraping rust from each arm of
cable rack support and its other chambers, nuts
and bolts etc. and then applying two coats of rust
preventor and two coats of epoxy paints.
1.01Removal of Heavy duty slab above 10 cm thick and
placing them back on the cable trench.Nos 191 Nil
1.02Removal of Light duty slab upto 10 cm. thick and
placing them back on the cable trench.Nos 279 Nil
1.03Cleaning and removal of rust from cable/cable
racks and various arms, application of rust
preventor and epoxy paint on all cable/cable racks.
Mtr. 820
Dencote/ anti
corrosive
paint
1.04
Cleaning of cable trench of various width. Removal
of rubbish containing ash, coal, fuel oil,
accumulated water filled trenches, stacking and
disposal of the same. The choked drain outlets of
the cable trenches are also to be cleaned with
water jets.
MTR 845 Nil
1.05
Sealing of slab joints of cable trenches with
premixed sand bitumen (250mg of bitumen of
80/100 grade is to be mixed with one cubic meter
of river sand ).
MTR 91Bitumen
Compound
1.06
Surface dressing uprooting of small bushes along
the cable trenches 30 cm wide from both side of
the trench and disposed of rubbish at nearest
available place.
MTR 1015 Nil
S.No
Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year 2016-17
(Section-F) Cleaning Jobs.
Rate AmountQuantityUnit Description
Signature of Issuing Authority Page 21 of F Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words NFL SUPPLYRemarks
S.No
Rate AmountQuantityUnit Description
2.00Cleaning of motors parts such as body, fan
covers, foundation bed, radiator, push button
station, site isolator etc.
2.01From fractional H.P to 5HP/3 KW.(420 Nos. per
round x 24 rounds)Nos 10080
Min.288 No. mandays are
required for execution of
job.
2.02above 5 HP to 20 HP/15 KW(125 Nos. per round x
24 rounds)Nos 3000
Min.144 No. mandays are
required for execution of
job.
2.03Above 20 HP to 40 HP/27 KW(150 Nos. per round
x 24 rounds)Nos 3600 Nil
Min.216 No. mandays are
required for execution of
job.
2.04
Above 40 HP to 200HP/149 KW(131 Nos. per round x
12rounds)Nos 1572
Min.144 No. mandays are
required for execution of
job.
2.05
Above 200 HP to 430 HP/320 KW (84 Nos. per round x 12
rounds)Nos 1008
Min.180 No. mandays are
required for execution of
job.
3.00
Cleaning of power panels, lighting panels, lighting
board, sub lighting distribution boards, small power
or control panel etc. (80 Nos. per round x 12
rounds)
Nos 960
Polishing
liquid or
cream
Min.240 No. mandays are
required for execution of
job.
4.00 CLEANING OF TRANSFORMERS.
4.01
6/10 MVA and 35 MVA (10 Nos. per round x 12 rounds)
Nos 120
Min. 240 No. mandays are
required for execution of
job.
4.02
1750 KVA , 2000 KVA and 2250 KVA (22 Nos. per round x
12 rounds)
Nos 264
Min. 240 No. mandays are
required for execution of
job.
4.031250 KVA & 750 KVA (20 Nos. per round x 12
rounds)Nos 240
Min.108 No. mandays are
required for execution of
job.
4.04
Small transformers below 750 KVA.(31 Nos. per round x 12
rounds) Nos 372
Min. 96 No. mandays are
required for execution of
job.
Nil
Nil
Nil
Signature of Issuing Authority Page 22 of F Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words NFL SUPPLYRemarks
S.No
Rate AmountQuantityUnit Description
5.00 Cleaning of substations/Transformers rooms/bays.
5.01
Large sized substations including basement such
as main substation /ammonia substation/SGP
substation. (Surface area 2800 sq mm and
above).(3 Nos. per round x 12 rounds)
Nos 36
Min.240 No. mandays are
required for execution of
job.
5.02
Medium substations such as coal handling
substation ,soot blower MCC rooms, Ammonia
MCC 2 , 5000 Te ammonia storage MCC, BFW
MCC room, 4th boiler substation, HCN chromate,
10 MVA transformers bay, 1750 KVA transformer
bays of unit group of plants and expansion plants,
1250 KVA sub-station, 750KVA sub-station,
emergeny diesel gen. station.(Surface area 600 sq
mtrs.) (80 Nos. per round x 12 rounds)
Nos 960
Min.360 No. mandays are
required for execution of
job.
5.03
Small substations/transformer bays etc. such as fly
wheel MG sets room / UPS rooms, battery rooms,
filter rooms or any other small
substation/transformer bay etc.(surface area below
600 sq m) (60 Nos. per round x 12 rounds)
Nos 720 Nil
Min.240No. mandays are
required for execution of
job.
6.00
Cleaning of cable racks and trays in carbon
recovery /urea plant, SGP (around boilers1, 2 & 3),
NOX plant, NLSP, Silo(CAN & Urea) &
Bagging(CAN & Urea).The cable racks and trays
laid horizontally are to be cleaned of dust, oil, coal
dust mixture and cleaning with jute brush.
6.01Cable trays/racks of size 15cm wide (3000 Metre
per round x 4 rounds)MTR 12000
Min.160 No. mandays are
required for execution of
job.
6.02
Cable trays/racks of size 30 cm wide(3285 Metre per round
x 4 rounds)MTR 13140
Min.216 No. mandays are
required for execution of
job.
Nil
Nil
Signature of Issuing Authority Page 23 of F Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words NFL SUPPLYRemarks
S.No
Rate AmountQuantityUnit Description
6.03Cable trays/racks of size 45cm wide(1300 Metre
per round x 4 rounds)MTR 5200
Min.120 No. mandays are
required for execution of
job.
6.04
Cable trays/racks of size 60 cm wide(3700 Metre per round
x 4 rounds)MTR 14800
Min.432 No. mandays are
required for execution of
job.
6.05Cable trays/racks of size 100cm wide(3500 Metre
per round x 4 rounds)MTR 14000
Min.320 No. mandays are
required for execution of
job.
7.00Uprooting /trimming /pruning trees coming up
beneath over-head lines.Uprooting of bushes
around over-head lines ,poles and substations.
7.01Trimming /pruning /uprooting of trees coming up
beneth the over-head net work if any. (1250 No.per
round x 6 rounds)
Nos 7500 Nil
Min.120 No. mandays are
required for execution of
job.
7.02
Uprooting of bushes (small trees) grass and wild
growth,surface dressing around 9 sq meters of
each RCC/steel tubular poles and then disposal of
rubbish at the nearest suitable place. (200 No.per
round x 12 rounds)
Nos
of
poles
2400 Nil
Min.240No. mandays are
required for execution of
job.
7.03
Uprooting of bushes (small trees) grass and wild
growth,surface dressing around 400 sq meters of
each substation. (20 No.sub-station per round x 4
rounds)
Sq
meter45000 Nil
Min.80 No. mandays are
required for execution of
job.
7.04
Uprooting of wild growth/grass from the pebbels in
the 66 KV Switch Yard , W.T. Plant and out sides
of 66 KV Switch-Yard(6000 sq.mr. per round x 6
rounds).
Sq
meter36000 Nil
Min.360 No. mandays are
required for execution of
job.
8.00Cleaning of Battry Bank (fortnightly) in different
sections as per their Voltages mentioned below:-
8.01
24 V Battery Bank (7 nos. 24 V Banks per round x 24
round)Nos 168
Petroleum
Jelly
Min.144 No. mandays are
required for execution of
job.
Nil
Signature of Issuing Authority Page 24 of F Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words NFL SUPPLYRemarks
S.No
Rate AmountQuantityUnit Description
8.02
48V/50 V Battery Bank (5 nos. Banks per round x 24 round)
Nos 120
Min.144 No. mandays are
required for execution of
job.
8.03
110 V Battery (6 nos. Banks per round x 24 round)
Nos 144
Min.216 No. mandays are
required for execution of
job.
8.04
220 V/240V Battery Bank (10 no Banks per round x 24
round)Nos 240
Min.288 No. mandays are
required for execution of
job.
8.05360 V Battery Bank (6 no Banks per round x 24
round)Nos 144
Min.192 No. mandays are
required for execution of
job.
9.00
Cleaning of air filters of following sizes installed in
the various substations for pressurisation
equipments. It includes removal of filters, cleaning
with water and pressurised air, refixing of filters
after cleaning and drying, replacement of filters.
9.01Filter size upto 600 x 600 mm.( Upto 3600 Sq.
mm.) (10 Nos. Filter per round x 12 round)Nos 120
Min.48 No. mandays are
required for execution of
job.
9.02Filter size upto 1000 x 500 mm.( Upto 500000 Sq.
mm.) (6Nos. Filter per round x 12 round)Nos 72
Min.48 No. mandays are
required for execution of
job.
9.03
Paper Filter Sets of Tranformer oil.This includes
removing of filters from oil filteration set and re-
fixing the same after cleaning.(6 Nos. Filter per
round x 12 round)
Nos 72
Min.48 No. mandays are
required for execution of
job.
10.00Cleaning of Surge counter / lightening arrestor/
Bushing / Insulators of T/ship & switchyard.Nos 600 Nil
Min.80 No. mandays are
required for execution of
job.
11.00Cleaning of gravels in transformer pits 35 MVA /10
MVA /1750 KVA/ 1250 KVA / 1000 KVA / 750 KVA
(50 Nos. Transformer Pits)
Nos 50 Nil
Min.500 No. mandays are
required for execution of
job.
Petroleum
Jelly
TOTAL
Nil
Signature of Issuing Authority Page 25 of F Signature of the Contractor with seal
Estimate No.-NFL/Elect./ARC-2016-17/01/16
In Figures In words In Figures In words
1.00
Supply of Unskilled
Casual Labours for
assistance during
ATA/short
shutdown/unforeseen
breakdowns.
Nos 1150 Nil
2.00
Supply of semi skilled
Casual Labours for
assistance during
ATA/short
shutdown/unforeseen
breakdowns.
Nos 110 Nil
In Figures
Total
Quantity NFL SUPPLY
GRAND TOTAL (A+B+C+D+E+F+G)
Amount
In words
Description
Schedule of Quantity and Rate for Annual Maintenance Rate Contract for Electrical Jobs for the year 2016-17
(Section-G) Casual Labour
Rate Amount
S.No Description Unit
Signature of Issuing Authority Page 26 of G Signature of the Contractor with seal
ABSTRACT FOR (NIT)
SCHEDULE OF QUANTITIES FOR
ARC (E) 2016-17
Estimate No.-NFN/2016-17/Elect./CO/ARC/01/16
Sr. No. Section Description Amount (Rs.)
1 A Cable Laying Jobs
2 B Wiring Jobs
3 C Lighting Jobs
4 D Misc. Jobs
5 E Overhead Line Jobs
6 F Cleaning Jobs
7 G Casual Labour
Total (Sec-A, B, C, D, E, F & G) (In
Figures)
Total (Sec-A, B, C, D, E, F & G) (In Words)