24
SCD 110 Sense | Connect | Detect Operating Instructions

SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

SCD 110 Sense | Connect | Detect Operating Instructions

Page 2: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

About these operating instructions | Compliant use 2 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

Table of contents

1 About these operating instructions 5

1.1 Compliant use ...................................................................................................................... 5

1.2 Definition of special notices .................................................................................................. 5

1.3 Definition of general notices ................................................................................................. 5

2 Safety and environment 5

2.1 Radio frequency radiation exposure and further information ............................................... 6

2.2 Disposal ................................................................................................................................ 6

3 Introduction 6

3.1 Scope of delivery .................................................................................................................. 6

4 Technical specification 7

4.1 Housing ................................................................................................................................ 7

4.2 Dimensions ........................................................................................................................... 7

4.3 Device specification ............................................................................................................. 7

4.4 Operating conditions ............................................................................................................ 7

4.5 Measurement range and accuracies .................................................................................... 8

4.6 Resolution ............................................................................................................................ 8

4.7 Sensors ................................................................................................................................ 8

4.8 Communication .................................................................................................................... 8

4.9 User interface ....................................................................................................................... 8

Page 3: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

About these operating instructions | Compliant use 3 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

4.10 Communication interfaces .................................................................................................... 8

5 First steps 9

5.1 Mounting the SCD ................................................................................................................ 9

5.2 Connecting to the SCD ........................................................................................................ 9

5.3 Configuring the SCD .......................................................................................................... 11

5.4 General information ............................................................................................................ 12

5.5 Thresholds .......................................................................................................................... 13

5.6 Streaming ........................................................................................................................... 13

5.7 Logging and transferring data ............................................................................................ 15

5.8 Removing the SCD ............................................................................................................ 18

5.9 Reusing the SCD ............................................................................................................... 18

6 General operation modes 18

6.1 General behavior ................................................................................................................ 18

6.2 Resetting the SCD ............................................................................................................. 18

6.3 Logging data to the local memory ...................................................................................... 19

6.4 Streaming via BLE (Bluetooth Low Energy) ....................................................................... 19

6.5 Event detection mode ........................................................................................................ 19

7 Maintenance 20

8 Further product related information 20

9 Error description 20

Page 4: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

About these operating instructions | Compliant use 4 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

10 Regulatory and legal information about the SCD 21

10.1 European Union notices ..................................................................................................... 21

10.2 USA: FCC notices .............................................................................................................. 21

10.3 IMDA Singapore notices ..................................................................................................... 21

10.4 ACMA Australia notices ...................................................................................................... 22

10.5 China notice ....................................................................................................................... 22

10.6 Japan notice ....................................................................................................................... 22

10.7 Other certifications ............................................................................................................. 22

10.8 Bluetooth® ......................................................................................................................... 22

10.9 Disposal .............................................................................................................................. 22

10.10 Restrictions of use ......................................................................................................... 22

10.11 Open source license condition ...................................................................................... 23

Page 5: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

About these operating instructions | Compliant use 5 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

1 About these operating instructions This document presents the SCD operating instructions, detailed SCD sensor characteristics as well as communication and management features through Bluetooth. This document refers to SCD firmware version 1.3.0. Detailed instructions on how to proceed are available at: https://www.bosch-connectivity.com/products/sense-connect-detect Ensure that the SCD is working correctly by reading these instructions carefully before using the SCD in your planned application.

1.1 Compliant use The SCD is intended for the following application areas: Environments Residential, commercial, light-industrial, and industrial

During use, observe the following operating conditions: Operating temperature range -20 °C … +85 °C Recommended storage temperature +10 °C … +30 °C Humidity range 0% RH … 100% RH

Validation and testing of any use or operation which requires specific requirements and standards not explicitly mentioned in these documents is the customer s responsibility. See also chapter 10.10 Restrictions of use.

1.2 Definition of special notices

Warning Indicates a hazard that could lead to minor or moderate injuries. Always follow these instructions.

Note Points of emphasis and reminders of device-specific operational features that could affect performance. Always follow these instructions.

1.3 Definition of general notices

2 Safety and environment Warning: Do not open the housing without authorization! Opening the housing without authorization will void any warranty and involves risk of injury to the user. Using the SCD according to its intended use and functions does not require the opening of the housing.

INFO: General information and instructions that must be followed

Tip: Practical advice

Page 6: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

Introduction | Radio frequency radiation exposure and further information 6 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

2.1 Radio frequency radiation exposure and further information The radiated output power of the device is far below the FCC radio frequency exposure limits. Nevertheless, the device must be used in such a manner that the potential for human contact during normal operation is minimized (see device specification, chapter 4.3).

2.2 Disposal Disposing of this product correctly will help save valuable resources and prevent any potential negative effects to human health and the environment, which could otherwise arise from inappropriate waste handling. Please contact the responsible local authority for further details on your nearest designated collection point. Penalties may apply for incorrect disposal of this waste, in accordance with your national legislation. For further information, please refer to chapter 10.9.

3 Introduction The SCD is a multi-sensor device that measures acceleration, magnetic fields, temperature and light. The robust housing and small design make it perfectly suited for industrial retrofit applications, such as condition monitoring and predictive maintenance. Configuring the device enables the user to address a broad variety of use cases.

3.1 Scope of delivery

• SCD device & built-in battery • Quick Start Guide • Packaging unit consists of 10 devices

Note No additional labels or stickers may be attached to the SCD. Otherwise, the proper function of the light sensor cannot be guaranteed.

On button

Green/Red LED

Screw holes

1

2

2 1

3

3

Page 7: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

Technical specification | Housing 7 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

4 Technical specification

4.1 Housing The SCD is built from a robust housing suited for industrial use with a self-adhesive back. The compact design of the SCD fits perfectly in different industrial applications and enables easy, user-friendly mounting in difficult-to-access environments. For mounting instructions, please refer to chapter 5.1. Mounting the SCD.

4.2 Dimensions

4.3 Device specification

4.4 Operating conditions

ATTRIBUTE VALUE Dimension Length 70.9 mm x Width 62 mm x Height 11.3 mm Weight 21 g Power supply non-rechargeable CR2450 3V Li/MnO2, 490 mAh Battery Life up to 2 years depending on configuration and use Enclosure protection class IP 67 Electrical protection class III Sampling rates (Hz) Acceleration : 400, 800, 1600, 3200, 6400

Magnetometer : 10 Temperature: 0.05 Light: 1.25, 10

Memory capacity 1 MB BLE (Bluetooth Low Energy) Activation In Standby: On push button

During operation: Automatic activation every 3 hours Country certifications CE, FCC Environmental certifications RoHS, REACH

ATTRIBUTE RANGE Environments Residential, commercial, light-industrial, and industrial Operating temperature range -20 °C … +85 °C Recommended storage temperature +10 °C … +30 °C Humidity range 0% rH … 100% rH

Page 8: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

Technical specification | Measurement range and accuracies 8 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

4.5 Measurement range and accuracies

Note Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications, depending on installation conditions and environmental influences.

4.6 Resolution

4.7 Sensors

4.8 Communication

4.9 User interface

4.10 Communication interfaces The SCD includes one Bluetooth Low Energy (BLE) communication interface. BLE • Bluetooth Low Energy V4.2 is currently supported. The SCD always acts as a peripheral device to which

other BLE devices like smartphones, tablets, etc. can establish a connection. • The Bluetooth communication interface is used, e.g. by a gateway or a mobile app, to:

Configure the SCD. Transfer data.

SENSOR MEASUREMENT RANGE ACCURACY Acceleration ± 200 g ± 10% Magnetometer ± 1300 µT (X, Y-Axis); ± 2500 µT (Z-

Axis) ± 5%

Temperature -20 °C … + 85 °C ± 0.25 °C Light 0 … 188000 Lux ± 15%

SENSOR RESOLUTION UNIT Acceleration 0.1 g Magnetometer 10 µT Temperature 0.1 °C Light 1 lux

INERTIAL SENSORS ENVIRONMENTAL SENSORS Accelerometer (3-axis) Temperature Magnetometer (3-axis) Light

ATTRIBUTE VALUE Communication

Bluetooth Low Energy BLE 4.2 Range up to 40 m (dependent on external influences)

ATTRIBUTE VALUE SCD Sensor App Free smartphone application for configuration, read-out and

visualization

Page 9: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | Mounting the SCD 9 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

5 First steps

5.1 Mounting the SCD The SCD housing has a self-adhesive back for mounting. The surface must be • flat• dry• cleanin order to mount the SCD.

Mounting the SCD: Peel off the protective film. Stick SCD to the surface.

5.2 Connecting to the SCD

Download the SCD Sensor App. The SCD Sensor App is available for free in the Apple App Storeor Google Play Store.

Apple App Store Google Play Store

Activate Bluetooth on your smartphone. To activate the SCD, press the button on the device for 1 to 3 seconds. Start the SCD Sensor App.

TIP: The SCD can also be attached to the respective device with screws using the premade holes

Page 10: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | Connecting to the SCD 10 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

After you start the app, the help screens offer you a short overview of the most important functions.

When starting the app, the search button is shown. Click on the search button to find devices.

TIP: In order to select the right SCD when multiple are available, move your smartphone/tablet close to the desired SCD.

Page 11: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | Configuring the SCD 11 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

Choose your SCD by tapping on your device in the list of devices to establish the connectionbetween the SCD device and the smartphone / tablet.

5.3 Configuring the SCD

Tap on the Settings icon.

To ensure easy identification of your devices, please rename your SCD by tapping on the pencil andtyping in your preferred name. Then tap Rename.

Note Only certain characters can be used for the device name.

The following characters are permitted: [A-Z][a-z][0-9][@.,;/\|+-*_]

a d b c e f

Page 12: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | General information 12 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

After renaming the device, you must wait 5–10 seconds. Afterward, you must establish the connection again.

5.4 General information

a. See help screens related to the area you are currently in.b. Disconnect: Click on the Disconnect icon if you want to disconnect your device.c. Rename your device and configure thresholds.d. Start / stop data streaming.e. Show the streamed data in a chart.f. Configure logging sampling rates, start / stop logging, download logging data.

Page 13: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | Thresholds 13 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

5.5 Thresholds

The threshold function monitors the streamed or logged values and triggers corresponding alarms via BLE if values are out of a defined range.

Set the threshold values by tapping the Settings icon.

If the values deviate from the defined range, they are displayed in the app in red.

5.6 Streaming

The streaming function transmits sensor values to the app at a fixed rate. Values can be visualized and recorded in the View tab. To start streaming, select the streaming button.

Tap on the streaming button to start streaming the measured data. The data is shown under therespective sensor icon.

Page 14: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | Streaming 14 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

Tap on the Diagram icon.

Select the sensors you want to see in the chart by tapping the sensor icons. The graphs and valuesare then displayed.

TIP: Values outside of the defined range are shown in red.

Page 15: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | Logging and transferring data 15 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

Options using the chart view

a. Refresh: If the user zooms in on the chart, tap on this icon to restore the original view.b. Enable/disable scrolling in the visible window to show all X values in the graph.c. Enable/disable auto scale of the y axis of the graph.d. Start / stop: Tap on this button to show / freeze streaming data in the graph.e. Starts / stops recording the streaming graph.f. Share the CSV of the last recorded session.

5.7 Logging and transferring data The logging function stores raw data in the SCD internal memory. Data can be later transmitted to the SCD app.

The logging settings can be configured by selecting the Logging icon.

a

b

c

d e f

Page 16: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | Logging and transferring data 16 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

Set the desired values. Tap on "Start logging".

Confirm the settings.

Page 17: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

First steps | Logging and transferring data 17 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

The data is stored until the memory is full or logging is stopped.

The data is ready for download.

Note The downloading process may take several minutes. Logging must be stopped in order to proceed with the data transfer.

Page 18: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

General operation modes | Removing the SCD 18 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

5.8 Removing the SCD

5.9 Reusing the SCD After the SCD has been removed, it can be reused. For mounting, proceed as described in chapter 5.1.

6 General operation modes The behavior of the operation modes is described in this chapter. For information on how to configure the SCD or how to retrieve data from it, please refer to chapter 5.

6.1 General behavior The individual sensors in the SCD can be activated / deactivated for measurements.

Additionally, different sampling rates for logging can be specified for each of the four sensors. The rates for the streaming function are fixed.

The reporting of the results is structured accordingly.

6.2 Resetting the SCD If there are problems with the SCD, a restart of the SCD may be necessary. In order to reset the SCD, proceed as follows:

Press the button on the SCD for at least 10 seconds. The LED lights up red once.

INFO: IP67 certification can no longer be guaranteed after removal.

INFO: IP67 certification is no longer guaranteed.

INFO: Do not use any sharp objects to remove the SCD.

TIP: The machine temperature should be below 40 °C.

Run a flat tool without a sharpedge between the SCD andthe surface.

Carefully lift the SCD andrelease it from the machine.

INFO: All stored values are lost in this process. Only the name of the SCD is still stored.

Page 19: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

General operation modes | Logging data to the local memory 19 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

6.3 Logging data to the local memory When the SCD is configured to log measurements to its local memory, a file will be created in the user data memory.

If the local memory is full, logging will be stopped. It is possible to log to memory and stream data via BLE at the same time.

The time until the memory is full depends on the SCD settings.

Examples: Accelerometer @6.4kHz (1 axis) will fill the memory in 60 seconds Accelerometer @3.2kHz (3 axis) will fill the memory in 40 seconds Accelerometer @1.6 kHz (3 axis) will fill the memory in 80 seconds Temperature alone will fill the memory in 52 days

The log file is formatted as a CSV file (comma separated values). The filename corresponds to the time stamp where data was downloaded. Header contains general information about the measurement. The real start of measurement corresponds to the calculation UNIX Timestamp + Delay Start [ms]. After this line, measurements are given according to the defined columns. If all four sensors are present, data is interleaved according to the sampling intervals.

Each line always contains all columns (i.e. the number of commas per line is constant). Each sensor has its own line and column. The SCD microcontroller has an internal time counter which is used for the timestamp deviation against real start of measurement in [ms] when logging to the local memory.

Evaluation takes place according to the pattern "[Sensor type], [Time Stamp], [Accel Data Length], [Data]." Example: [Temperature], [15462], [ ], [33] [Accelerometer], [1272], [504], [13, 1, 16, 15, 6, -21, …, 16, 5, -5]

Note The Accel Data Length data is omitted for Temperature, Light and Magnetometer. • Accel Data Length indicates the number of values measured by the accelerometer.• The measured values of the x, y, z axis are repeated in succession (x, y, z, x, y, z, etc.).• Real time of a sample = UNIX Timestamp + Start Delay + Time Stamp

6.4 Streaming via BLE (Bluetooth Low Energy) As standard, the SCD acts as a Bluetooth Low Energy (BLE) advertiser. This means that another BLE device may detect the SCD when scanning for devices and is able to initiate a connection. Using BLE, it is possible to configure a SCD and continuously receive measurement data from it.

6.5 Event detection mode In event detection mode, the user is able to define thresholds for one or more sensor signals of the SCD. Each time the respective measurement signal crosses the threshold, an event is generated and signaled via the app.

Page 20: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

Maintenance | Event detection mode 20 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

SCD with active threshold surveillance is always visible in BLE, even if the user disconnects from the SCD.

7 Maintenance Warning: Damage to materials can cause risk of fire! Liquid which enters the device can cause short circuits and damage the device. This could cause fire, data loss and incorrect measurements.

8 Further product related information Please find all product related documents and user guides on our website: https://www.bosch-connectivity.com/products/industry-4-0/sense-connect-detect/downloads/

Download the SCD Sensor App

Apple App Store Google Play Store

9 Error description Problem Solution The app does not display any values Check whether you have switched on the

sensors in the app. The light sensor is permanently at 0 Check whether any additional labels have been

attached to the SCD. These can cover the light sensor.

The protective cover is damaged Do not use the device. None of the values are changing—is the sensor defective?

Check whether you have switched on streaming in the app. Check if the sensor you are interested in is active.

Page 21: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

Regulatory and legal information about the SCD | European Union notices 21 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

Connection fails Make sure you get a OS dialog asking for “Pairing”. Make sure you accept pairing.

I get disconnected after a while Make sure a Streaming or Logging session is active. There is a timeout of 2 minutes. If there is no activity sensor will disconnect to save battery.

10 Regulatory and legal information about the SCD Accompanying information

Radio power: 2 mW (peak conducted)

Frequency band: 2400 – 2483.5 MHz

10.1 European Union notices European Union notices

Radio Equipment Directive

Bosch Connected Devices and Solutions GmbH hereby declares that the radio equipment type "SCD" is in compliance with Directive 2014/53/EU (Radio Equipment Directive). The full text of the EU declaration of conformity is available at the following internet address: https://www.bosch-connectivity.com/products/industry-4-0/sense-connect-detect/downloads/ (CISS Declaration of Conformity).

RoHS

The SCD meets the requirements of the Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive).

REACH

The SCD meets the requirements of the Directive 1907/2006 (REACH Directive, as of: July 2019) and does not contain substances of very high concern as specified in the REACH Directive in concentrations which require notification.

10.2 USA: FCC notices FCC has issued an EQUIPMENT AUTHORIZATION to Bosch Connected Devices and Solutions GmbH for SCD according to FCC rule parts 15 C with the FCC ID: 2ADSJCISS

Note: Changes or modifications not expressly approved by Bosch Connected Devices and Solutions GmbH could void the FCC certificate and therefore user's authority to operate the equipment.”

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

10.3 IMDA Singapore notices The SCD has been registered with the Info-communications Media Development Authority under regulation 20(6) of the telecommunications (Dealers) regulations (Cap 323, Rg 6) and approved for sale in Singapore under Dealer's License DB101762.

Page 22: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

Regulatory and legal information about the SCD | ACMA Australia notices 22 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

10.4 ACMA Australia notices This device complies with the requirements of the relevant ACMA Standards made under the Radio communications Act 1992 and the Telecommunications Act 1997.

10.5 China notice This device has passed the type approval by SRRC and has been granted the CMIIT ID: 2018DJ2794

10.6 Japan notice This device is granted pursuant to the Japanese Radio Law (電波法). This device should not be modified (otherwise the granted designation number will become invalid)

10.7 Other certifications The SCD is certified for operation in the European Union, the U.S.A., Singapore, Australia and China.

The certification for the European Union only applies to SCD devices with the CE printed on the housing. The user shall verify before using the SCD in the European Union.

The certification for the United States of America only applies to SCD devices with the FCC ID printed on the housing. The user shall verify before using the SCD in the United States of America.

The certification for Australia only applies to SCD devices with the ACMA label printed on the packaging or on the housing. The user shall verify before using the SCD in Australia.

The certification for China only applies to SCD devices with the CMIIT ID printed on the housing. The user shall verify before using the SCD in China.

The certification for Singapore only applies to SCD devices with the IDMA mark on the housing or with the "Complies with IMDA standards DB101762" notification printed on the front page of the "Quick Start Guide" / Operating Instructions. The user shall verify before using the SCD in Singapore. Use of the SCD is subject to validation and observation of local legal regulation by the customer. For information on other certifications – which gradually may be issued over time – please contact our SCD support at [email protected].

10.8 Bluetooth® The SCD has been granted the Bluetooth® listing by the BT-SIG.

10.9 Disposal The unit, accessories and packaging should be sorted for environmental-friendly recycling. Do not dispose of the device into household and industrial waste!

According to the European Guideline 2012/19/EU, electric and electronic devices that are no longer usable must be collected separately and disposed of in an environmentally correct manner.

10.10 Restrictions of use SCD housing is not to be opened or tampered with. SCD is designed for use in the environmental conditions detailed in this operating instructions. It is the customer's responsibility to validate and test any use or operation under deviating environmental conditions.

Neither the SCD nor a potential product derivation are designed, intended or authorized for use as components in systems intended for surgical implant in the body, or other applications intended to support or sustain life, or for any other application in which the failure of the Bosch product could create a situation where personal injury or death may occur. The same applies for any kind of weapon, or any device or application which is potentially dangerous for human life.

The SCD is designed for monitoring purposes and shall not be used as an element of control and safety in machines under the scope of the Machinery Directive 2006/42/EC.

Bosch Connected Devices and Solutions GmbH shall not be held liable for any damages resulting from any use of the SCD outside/beyond the certified types of operation and/or defined field of application.

Page 23: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

Regulatory and legal information about the SCD | Open source license condition 23 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

10.11 Open source license condition The SCD embedded software contains open source software (OSS) components.

The OSS copyrights and license conditions are provided in the file "DataStreamer_v02.01.01_FOSS_Disclaimer.txt" which can be read after connection of the SCD via USB as a mass storage device to your PC.

For further assistance, please refer to http://www.bosch-connectivity.com/SCD or e-mail [email protected]

Page 24: SCD 110 Sense | Connect | Detect · Note . Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications,

Regulatory and legal information about the SCD | Open source license condition 24 | 24

Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM

Bosch Connected Devices and Solutions GmbH Ludwig-Erhard-Straße 2 72760 Reutlingen Deutschland www.bosch-connectivity.com