design mix

Citation preview

Sheet12

Sheet11

Sheet10

Sheet1LANCO INFRATECH LIMITEDLANCO HILLS TECHNOLOGY PARK PROJECT, MANIKONDAMIX DESIGN( Self compacting concrete )Mix Reference:SCC-070Designed By:Giridhar YadavGrade of Concrete:M 60Date:26.06.08Maximum Size of Aggregate:20mmBasic Data:Brand / Type of Cement::RASI GOLD(PPC)Specific Gravity of Cement::3.15Specific Gravity of Micro Silica2.09Type of Fine aggregate (I)::Natural / River SandSource of Fine aggregate: (I):VijayawadaSpecific gravity of Fine aggregate: (I):2.582Water Absorption of Fine Aggregate: (I):1.20%Type of Coarse Aggregate::CrushedSource of coarse aggregate::LHTPPL CrusherSpecific gravity of coarse aggregate:(Type-1):2.655Specific gravity of coarse aggregate:(Type-2)2.623Combined Specific gravity of C.A & F.A:2.611Size of Coarse Aggregate: (Type I):20mmWater Absorption of Coarse Aggregate (Type I)::0.20%Size of Coarse Aggregate: (Type II):12.5 mmWater Absorption of Coarse Aggregate (Type II)::0.40%Percentage of Fine aggregate (I) in Total Aggregate:45.0%Percentage of 20mm in Total Aggregate:22.0%Percentage of 10mm in Total Aggregate:of 12.5mm in Total Aggregate:33.0%Make of Admixture::BASF% Admixture on weight of cementitious material:Admixture-1(SP):Glenium B233(1.4%)Admixture-2(VMA):Glenium Stream-2(0.3%)Mix ProportionsTotal cementious material:615KgCement:590KgMicro silica:25KgFree Water.:160KgWater for Absorption:12.00KgTotal Water:172.00KgAdmixture:8.610KgVMA:1.845KgSand:729Kg20mm:357kg12.5mm:535KgMix Ratio:Cement:SandCoarse Aggregate( By Weight )11.191.45Water Cementitious Ratio:Free W/C Ratio:0.26Total W/C Ratio:0.28(QA/QC MANAGER)

Sheet2LANCO INFRATECH LIMITEDLANCO HILLS TECHNOLOGY PARK PROJECT, MANIKONDACONCRETE MIX DESIGN - CALCULATION SHEETGrade of ConcreteM 60A.Maximum size of Aggregate20mmB.Characteristic Compressive Strength60MPaC.Standard Deviation:5D.Target Mean Strength: (B) + (1.65 x C)68.25MPaE.Requirement of water per cum of concrete160LitresF.Water - cement ratio for the above Target Strength0.26G.Cement Content obtained from the above615Kgs(E) / (F)H.Minimum Cement Content as per IS 456-2000(for moderate Exposure)J.Cementitious Content finalised615KgsKAbsolute Volumes occupied as per the below given table)MaterialSpecific GravityWeightAbsolute VolumeCement3.155900.187Micro silica2.09250.012Water11600.160Entrapped Air (2%)0.020LTotal volume occupied by Cement + Water+Air0.379MBalance Volume to be occupied by aggregates:1.000 - (I)0.621NVolumes occupied by each aggregates (as per the grading)River Sand020 mm aggregate10 mm aggregateGrading:45.022.033.0Absolute Volumes (obtained as product of M and above value):0.2790.0000.1370.205OWeights of Aggregates (calculated from the absolute volume)(as per the below given table)MaterialCombined Spec. GravityAbsolute VolumeWeight in Kgs.River Sand2.6110.27972920mm0.137357`10 mm0.205535Total Density of Fresh Concrete (Cement+Aggregates+Total Water)2408Kg/m3Mix Proportions:CementWaterFree W/C Ratio6151600.260`CementFine AggregateCoarse AggregateAgg / Cement Ratio1.001.191.452.635(QA/QC MANAGER)

Sheet3LANCO INFRATECH LIMITEDLANCO HILLS TECHNOLOGY PARK PROJECTMANIKONDAMIX OBSERVATIONS & COMPRESSIVE STRENGTH REPORTSL.NOGRADE OF CONCRETEDESCRIPTIONFLOWL-BOX(H2/H1)V-FunnalDATE OF CASTINGDATE OF TESTINGAGE IN DAYSWEIGHT (Kg)DENSITYLOAD (KN)STRESS (Mpa)AVG. STRESS (Mpa)1M-60W/C ratio :0.26%26.06.0729.06.0838.1902.42793041.332cement(RASIGOLD(PPC)) 590kgs8.1302.40998043.5641.783Free water :160Kgs750 mm8.1102.40391040.444Water Absorption 12Kg790 mm1.028.43 Sec03.07.0878.1802.424125055.565Total water 172 Kg770 mm8.2402.441127056.4455.566Micro silica : 25KgAvg Flow8.5402.530123054.677River Sand (45%) :729 Kgs770 mm820 mm Aggregates 357 KgsBy ACT8.022.376151067.11912.5 mm Aggregates :535Kgs7.962.359155068.8969.0410Admixture(1):Glenium B233 (1.4%), 8.61kg8.202.430160071.1111Admixture(2) V M A (0.3%), 1.845kgBy Equation R28=8.09+1.64*Ra=121.30 N/mm224.07.08288.202.430168074.678.402.489167074.2274.818.432.498170075.56

Sheet4