29
Scans • 300 second • A “Blank” scan was taken and the results were subtracted from the other scans.

Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Embed Size (px)

Citation preview

Page 1: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Scans

• 300 second

• A “Blank” scan was taken and the results were subtracted from the

other scans.

Page 2: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Data

Black Pigment Area Orange Pigment Area White Pigment Area

Scans too diffuse for phase analysis

White pigmented area more crystalline structure

More analysis is needed (stay tuned!)

Page 3: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Nylon Testing

Nylon 66 produced last week in the polymer lab

used for Dynamic Mechanical Testing

DMA Mount with sample

Page 4: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Test Results on Nylon66

l

l

ll l l l l l l l

ll

l

ll

l l l l l l l l l l ll

l

l

l

l

l

l

l

p

p

pp

p

p

pp

pp p p

pp

pp

p

p

p

p

p

p

p

p

p

p

p

p

ppp

p

p

p

p

p

p

p

p

p

pp

ppp p

p pppp p p p p p p

p

p

pp

p

p

p

p

p

p

0.10

0.15

0.20

0.25

0.30

[ ]

Tan

Del

tap

10

100

1000

[ ]

Com

plex

Mod

ulus

(M

Pa)

l

0 50 100 150 200 250 300

Temperature (°C)

Sample: nylon66Size: 6.2799 x 0.2500 mmMethod: Temperature Ramp

DMAFile: C:\Users\RET\nylon66300.001Operator: Yi LinRun Date: 17-Jul-2008 14:26Instrument: DMA Q800 V7.4 Build 126

Universal V4.3A TA Instruments

Page 5: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Test Results Manufactured Nylon

l

l

ll l l l l l l l l l

ll

ll

ll

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

p

p

p

p

p

p

p

p

pp

p p p p p pp

pp p

p

pp

pp

pp

ppppppp

ppppppp

pp

p

p

p

p

p

p

ppppppp

0.00

0.05

0.10

0.15

0.20

0.25

[ ]

Tan

Del

tap

10

100

1000

10000

[ ]

Com

plex

Mod

ulus

(M

Pa)

l

0 50 100 150 200 250 300

Temperature (°C)

Sample: nylon66Size: 6.7088 x 0.2700 mmMethod: Temperature Ramp

DMAFile: C:\Users\RET\nylonstring300.002Operator: Yi LinRun Date: 17-Jul-2008 15:56Instrument: DMA Q800 V7.4 Build 126

Universal V4.3A TA Instruments

Page 6: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Comparing Nylons

l

l

ll l l l l l l l

ll

l

ll

l l l l l l l l l l ll

l

l

l

l

l

l

l

p

p

pp

p

p

pp

pp p p

pp

pp

p

p

p

p

p

p

p

p

p

p

p

p

ppp

p

p

p

p

p

p

p

p

p

pp

ppp p

p pppp p p p p p p

p

p

pp

p

p

p

p

p

p

0.10

0.15

0.20

0.25

0.30

[

] Tan

De

ltap

10

100

1000

[

] Co

mpl

ex M

odu

lus

(MP

a)l

0 50 100 150 200 250 300

Temperature (°C)

Sample: nylon66Size: 6.2799 x 0.2500 mmMethod: Temperature Ramp

DMAFile: C:\Users\RET\nylon66300.001Operator: Yi LinRun Date: 17-Jul-2008 14:26Instrument: DMA Q800 V7.4 Build 126

Universal V4.3A TA Instruments

l

l

ll l l l l l l l l l

ll

ll

ll

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

p

p

p

p

p

p

p

p

pp

p p p p p pp

pp p

p

pp

pp

pp

ppppppp

ppppppp

pp

p

p

p

p

p

p

ppppppp

0.00

0.05

0.10

0.15

0.20

0.25

[

] T

an

De

ltap

10

100

1000

10000

[

] C

om

ple

x M

od

ulu

s (M

Pa

)l

0 50 100 150 200 250 300

Temperature (°C)

Sample: nylon66Size: 6.7088 x 0.2700 mmMethod: Temperature Ramp

DMAFile: C:\Users\RET\nylonstring300.002Operator: Yi LinRun Date: 17-Jul-2008 15:56Instrument: DMA Q800 V7.4 Build 126

Universal V4.3A TA Instruments

NYLON 66

NYLON STRING

Nylon 66 had a higher melting point

Nylon String had a higher Complex Modulus

Page 7: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Scintag (2 Theta Diiractometer)

• Diffractometer -is a measuring instrument used for analyzing the structure of a usually crystalline substance from the scattering pattern produced when a beam of radiation or particles (as X rays or neutrons) interacts with it.

Page 8: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Corals-Old and New

Fossil (Devonian) Coral Recent Coral

Page 9: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Fossil CoralPeaks match for Calcite (Calcium Carbonate)

Page 10: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Recent CoralPeaks match Aragonite (Calcium

Carbonate)

Page 11: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Comparison of Corals

Fossil coral

Recent coral

Page 12: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Calcite and Aragonite are Polymorphs.

Polymorphs have the same chemistry but different crystal structures and symmetries.

Aragonite is thermodynamically unstable at standard temperature and pressure

Page 13: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

In order for aragonite to be stable at higher temperatures, there has to be higher pressures

Aragonite forms naturally as the calcareous endoskeleton of warm- and cold-water corals (Scleractina)

How does the coral do it?

Page 14: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Are they real gemstones? or

The case of the star-crossed ruby

Page 16: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Multiwire Ltd. Back Reflection LaueUsed to determine if we have a crystal and what its structure is.

Page 17: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Film is placed between the x-ray source and the sample.

Beams which are defracted in a backward plane are recorded

Page 18: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

One side of the cone of Laue* is defined by the transmitted beam.

The film intersects the cone with the diffraction spots generally lying on the parabola

*The cone of Laue has no relationship to the Cone of Silence.

Page 19: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Diamond?Crystalline structureSome Symmetry

Emerald?No crystallineStructure. Fake.

Ruby?Crystalline StructureGood symmetry

Page 20: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Analysis in GADDS

Arcs= Peaks in Scintag

Dots = Single Crystals

You can’t analyze single crystals in the Scintage XRD.

Page 21: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Analysis of the peaks revealed that theDiamond(?) was actually Yttrium Oxide.

Page 22: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

IT IS A RUBY!!!!

Page 23: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

But why did the star ruby cause Petra’s pacemaker to stop?

Page 24: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Only the shadow knows.

Page 25: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Diffractor

• Niobium Tin on Silicon (Nb3Sn)

• 2 annealed

• 2 unannealed

Page 26: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Nb3Sn (annealed)

Page 27: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

Nb3Sn (unannealed)

Page 28: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

X-Ray Scattering

• Annealed Sample (Nb3Sn)

Page 29: Scans 300 second A “Blank” scan was taken and the results were subtracted from the other scans

X-Ray Scattering

• Unannealed Sample (Nb3Sn)