18
INSTALLATION MANUAL Saunier Duval Clima, S.A. ENGLISH Safety Regulations ............................................. 3 Indoor Units Installation and Dimensions Ducted ........................................................... 4 - 5 Cassette ........................................................ 6 - 8 Ceiling-Floor ................................................ 9 - 10 Installation ..................................................11 - 12 Outdoor Units Dimensions .........................13 - 14 Wiring Diagrams ............................................... 15 Control Units Diagrams ..............................16 - 18 SDCE/HE 050 D/K/F SDCE/HE 065 D/K/F SDCE/HE 085 D/K/F SDCE/HE 105 D/K/F SDCE/HE 105T D/K/F SDCE/HE 130 D SDHE 180 D SDHE 230 D www.saunier-duval.co.uk 2003

Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

INSTALLATION MANUAL

Saunier Duval Clima, S.A.

EN

GLI

SH

Safety Regulations ............................................. 3

Indoor Units Installation and Dimensions

Ducted ........................................................... 4 - 5Cassette ........................................................ 6 - 8Ceiling-Floor ................................................ 9 - 10

Installation ..................................................11 - 12

Outdoor Units Dimensions .........................13 - 14

Wiring Diagrams ............................................... 15

Control Units Diagrams ..............................16 - 18

SDCE/HE 050 D/K/FSDCE/HE 065 D/K/FSDCE/HE 085 D/K/FSDCE/HE 105 D/K/FSDCE/HE 105T D/K/FSDCE/HE 130 DSDHE 180 DSDHE 230 D

www.saunier-duval.co.uk2003

Page 2: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

3

EN

GLI

SH

Page 3: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

3

EN

GLI

SH

INSTALLATION, MAINTENANCE AND REPAIR

1- SAFETY REGULATIONS

1. Prior to any intervention in the appliance, installation, start-up, use and maintenance, the staff in charge of these operations must be familiar with all the instruc-tions and recommendations appearing in the appliance installation manual, likewise the elements in the tech-nical dossier of the product.

2. The staff in charge of the appliance reception must carry out a visual control to verify the damages which might have occurred to the appliance during transport.

3. Installation of the appliance close to a heat source, combustible and corrosive materials or the air intake conduit of an adjacent building is prohibited.

4. The appliance is to be installed, maintained and repai-red by qualified staff pursuant to the demands of the guidelines, current regulations not to mention the trai-ning of the professional him/herself.

5. Check that the mounting and fastening devices are sufficient to withstand the weight of the unit. If they are not, the unit may fall and cause an accident.

6. Do not use any coolant other than R-407C. The mix-ture of gases in the cooling cycle can lead to damage or impaired performance.

7. While connecting the outdoor unit, keep the cabling conduit rigid. Faulty cable fitting can cause overhea-ting, electrical discharges or fire at these connections.

8. Place the drainage hose in a suitable position. An improperly fitted hose will force the water back to the room, thus damaging the furniture.

9. During the appliance maintenance phase, heat sour-ces and cooling fluids must be controlled.

10. The system must always be earthed. If it is not, this may lead to electrical discharges.

11. Prior to intervening the refrigeration circuit, it is compul-sory to stop the appliance for a few minutes to reduce the compressor and piping temperature, because during normal functioning they may reach temperatu-res exceeding 100ºC involve the risk of burns.

13. Any welding intervention is to be performed by quali-fied welders.

14. Use the voltage indicated in the manual. Incorrect vol-tage may cause fires or other problems.

15. Always use original Saunier Duval spare parts. Do not use components removed from defective refrigeration appliances as replacements.

16. It is expressly prohibited to carry out any modifications to the refrigeration circuit, the cooling gas type indica-ted on the characteristics place, likewise application of the appliance outside those application limits appea-ring in the documentation or any other kind of modifi-cation. Any modification will cancel out the EC marking pursuant to the PED (97/23/EC Guideline) and the person who carries out the said modification will be liable for the same.

1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications without previous notice.

2 Saunier Duval cannot foresee all circumstances that could result in hazard potentials.

3 No part of this manual can be copied without written permission.

4 Should you have any queries, please contact your nearest Saunier Duval distributor.

IMPORTANT NOTES

EXTREME OPERATION CONDITIONS

SUMMER - OUTDOOR 0ºC Min. 43ºC Max. - INDOOR 21ºC Min. 32ºC Max.WINTER - OUTDOOR -5ºC Min. 24ºC Max. - INDOOR 15ºC Min. 27ºC Max.

• This A.C. unit has been designed for the operating temperatures specified below, do not let it work outside said ranges.

Page 4: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

4

EN

GLI

SH

5

EN

GLI

SH

2.1.3 INDOOR UNIT INSTALLATION

- Insert and screw down a nut on each supporting rod.- Lift the indoor unit and insert the rods in the holes pro-

vided on the mounting brackets.- Place a washer and nut on each of the rods.- Level out the machine and fix it tightening so that nuts

are pressed against each other.- It is advisable to place a lock nut against the lower nut

on the suspension rods.- This indoor unit has been originally designed for

installation on false ceilings. Where the unit is to be mounted on a location with easy access, the electric wiring bar must be protected to prevent hazardous situations.

2.1.4 DRAIN PIPE INSTALLATION

- Special care should be taken when laying drain tubing, otherwise if any problem occurs the condensed water of the evaporator could spill.

- Do not place the drain pipe in an upwards position otherwise drain water would go back to the unit and spill when the unit would stop.

- Do not connect the drain pipe to the sanitary drains, waste water drains or any other drain facility if a trap is not installed.

- When a common drain pipe is connected to other indoor units, connection positions of each unit should be at a higher level than the common pipe. The common pipe length should be appropriate for the size and number of existing units.

2.1.5 SUSPENSION OF THE INDOOR UNIT

Hang up the indoor unit as shown in the figure below.Parts supplied by the filter:- Suspension Rod- Nut- Washer

2.1.1 INITIAL CHECK

- Install indoor unit allowing for enough clearance around the unit so there is room for handling and maintenance operations as shown below:

- Avoid any obstacles that could impair air take-up or discharge flow.

- Do not install the indoor unit in a machinery workshop or in a kitchen where oil or smoke mist could flow into the indoor unit. Oil would be deposited in the heat exchanger resulting in a reduced unit performance. Also, internal plastic parts could be deformed or they could even break as a result.

- Note the following items when the indoor unit is to be installed in a hospital or premises where electromag-netic waves from medical equipment may be present.

A) Do not install the indoor unit where electromagnetic waves directly impinge on the electric box, the remote control switch or the remote control cable.

B) Install the unit as far as possible from the electromag-netic wave source. A 3 metre clearance should be arranged.

C) Install a noise filter when the power supply produces disturbing noises.

D) Select final location and direction of the indoor unit paying special attention to tubes, cables and mainte-nance.

E) When selecting the indoor unit location, the air ducting network should be borne in mind in order to facilitate distribution.

2.1.2 FIXING THE UNIT

- Use the appropriate fasteners for each structure type paying special attention to any possible transmission of vibrations and noise. Noise or vibration proof items should be provided if it is considered to be necessary.

2- INDOOR UNIT INSTALLATION

NOTE:Is very important the positioning of a siphon in each water-drai-nage.

400

200

500

2.1 DUCTED: INDOOR UNIT

Page 5: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

4

EN

GLI

SH

5

EN

GLI

SH

2.1.6 INDOOR UNIT DIMENSIONS (EDI)

2- INDOOR UNIT INSTALLATION

Units in mm.

MODELS A B C D E F G H J K L Kg.

Conec.

050 EDI 1.000 525 240 878 156 940 170 1.040 246 34 100 29 Weld

065 EDI 1.000 525 240 878 156 940 170 1.040 246 34 100 30 Weld

085 EDI 1.010 666 295 900 196 950 230 1.050 325 34 100 40 Weld

105 EDI 1.210 666 295 1.100 196 1.150 230 1.250 325 34 100 47 Weld

130 EDI 1.315 700 315 1.100 196 1.150 250 1.355 335 34 100 53 Weld

180 EDI 1.400 840 361 1.047 225 1.305 305 1.445 455 34 100 60 Weld

2.1.7 INDOOR UNIT DIMENSIONS (EZHI)

Is very important the posi-tioning of a siphon in each water-drainage.

Units in mm.

Indoor Unit Location

Page 6: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

6

EN

GLI

SH

7

EN

GLI

SH

2- INDOOR UNIT INSTALLATION

2.2.1 Install the indoor unit in a position:

- Having sufficient strength to carry the weight of the indoor unit.

- Where the inlet and outlet grilles are not obstructed and the conditioned air is able to blow all over the room.

- From where pipes can be easily run to the outdoor unit.

- From where condensate can be easily run to drain.- Check the distance between the upper slab and false

ceiling to ensure the unit will suit the distance.

Cassette Indoor Unit:

- Using the installation template open ceiling panels and install the suspension bolts.

- Ensure there is sufficient space around the unit to service it.

2.2 CASSETTE: INDOOR UNIT

2.2.2 INSTALLATION METHOD

MODEL H (mm)

050 EKI 261

065 EKI 263

085 EKI 263

105 EKI 420

- Ensure the ceiling is horizontally level, otherwise condensate water cannot drain.- The casing is fixed to the slab with 4 drop rods. The rods should have two nuts and washers to lock the unit in position.

The Cassette brackets will then hook over the washers.- When lifting the Cassette into position care should be taken not to lift the unit by the drip tray, which could be damaged.- Lift unit (without the air panel) with care by its four corners only. Do not lift unit by the condensate drain discharge pipe

or by the piping connections.- Incline unit and insert it into the false ceiling. Insert the rods into the brackets slot.

With false ceilings minimum height (see table), it might be necessary to remove some T brackets of the false ceiling temporarily.

Page 7: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

6

EN

GLI

SH

7

EN

GLI

SH

2- INDOOR UNIT INSTALLATION

MODEL A (mm)

050 / 065 EKI 3

085 EKI 3

105 EKI 83

- We recommend that screened cable be used in electrically noisy areas.- To avoid electro-magnetic control systeminterference, always separate (5 VCC) low voltage signal wires from (220 VCA)

power line.- Do not install the unit where electromagnetic waves are directly radiated at the infra red receiver on the unit.- Install the unit and components as far as practical (at least five metres away from the electromagnetic wave source).- Install a noise filter if any harmful noise exists in the power supply.

105 EKI 050 / 065 / 085 EKI

2.2.3 INTERCONNECTING WIRING

- Using level guide, line up the unit with a spirit level, and keep dimension between the fiber glass body and the lower part of the false ceiling.

- Line up the unit to the supporting bars of the false ceiling tightening the nuts and counternuts of the threaded rods.- After connection of the condensate drain piping and piping connections, check again that the unit is level.

Page 8: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

8

EN

GLI

SH

9

EN

GLI

SH

2- INDOOR UNIT INSTALLATION

- The side opening allows separate ductwork to be installed for outside air intake and branch ducting. - Cut and remove anti-condensate insulating material.- Install your flanges and conduits to casing. Conduits can be flexible polyester with spring core or corrugated aluminum

externally coated (dia.4 in.) with anti-condensate material (fiberglass 12-25 mm thickness).

Indoor Unit:

- The unit is fitted with a condensate pump with a 500 mm lift.- The unit is provided with 22 mm bore flexible hose 300 mm long.- The flexible hose should be fitted into a 22 mm polyvinyl tube and sealed. The 22 mm drain must be installed with a

downward slope.- On completion the drain line should be insulated.

2.2.4 FRESH AIR RENEWAL AND BRANCH DUCTING

2.2.5 DRAIN PIPEWORK

Model A* B* C D E F050 / 065 EKI 590 590 521 460 700 700

085 EKI 590 1099 521 995 700 1205105 EKI 885 885 665 830 950 950

Units in mm.

2.2.6 CASSETTE INDOOR UNIT DIMENSIONS (EKI)

(*) Minimum dimensions of hollow

Page 9: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

8

EN

GLI

SH

9

EN

GLI

SH

- When the direction are selected, drill 4” (100 mm) dia. hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow. When the pipe is led out from the rear, make a hole at the position shown.

2- INDOOR UNIT INSTALLATION

2.3.1 INSTALLATION PROCEDURE

A. PREPARING INDOOR UNIT INSTALLATION

Remove the intake grille and side cover(s) by removing the tapping screws.

2.3.2 INDOOR UNIT INSTALLATION

A.FLOOR INSTALLATION

A.1 DRILLING FOR PIPING

Select piping and drain direction. The piping and drain can be made in two directions.

- The drain hose can be connected to the drain port either left or right side.

A.2 INSTALLING DRAIN HOSE

Be sure to arrange the drain hose so that it is levelled lower than the drain port of the indoor unit.

2.3 CEILING-FLOOR: INDOOR UNIT

When the directions are installed, drill a 3 1/8” (80 mm) or 6” (150 mm) dia. hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow.

B. CEILING INSTALLATION

Using the distance between drilling holes as shown below, drill holes for piping and anchor bolts.

B.1 DRILLING FOR PIPING

Select piping directions.

- Install the drain hose at the rear, it should not be installed on the top.

Page 10: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

10

EN

GLI

SH

11

EN

GLI

SH

B.4 INSTALLING INDOOR UNIT

Reset the bolts as shown below.

Apply the indoor unit to hangers.

B.2 DRILLING HOLES FOR ANCHOR BOLTS AND INSTALLING THE ANCHOR BOLTS

With a concrete drill, drill four 3/8” (9,5 mm) dia. holes.

2- INDOOR UNIT INSTALLATION

Insert the anchor bolts into the drilled holes, and drive the pins completely into the anchor bolts with a hammer.

B.3 INSTALLING HANGERS

Install the hangers with nuts and spring washers.

Now, securely tighten the bolts in both sides.

B.5 INSTALL THE DRAIN HOSE

Be sure to arrange the drain hose so that its level lower than the drain port of the indoor unit.

Always check that the drain cap is installed to the unused drain port and is fastened with the nylon fastener. If the drain cap is not installed, or is not sufficiently fastened by the nylon fastener, water may drip during the cooling operation.

2.3.3 CEILING-FLOOR INDOOR UNIT DIMENSIONS (EFI)

MODEL A B C D E F kg.

050 EFI 645 955 199 280 185 873 30 065 EFI 645 955 199 280 185 873 30 085 EFI 645 1.250 199 280 185 1.168 40 105 EFI 645 1.750 199 280 185 1.668 56

Units in mm.

Page 11: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

10

EN

GLI

SH

11

EN

GLI

SH

3.2 Pipe connection

3- INSTALLATION

3.1. OUTDOOR UNIT(1) Install de outdoor unit in a place where it will be free from being dirty or getting by rain as much as possible.(2) During heating operation, drain water flows from the outdoor unit. Therefore, install the outdoor unit in a place where the drain water flow will not be obstructed. (Heat pump model only).(3) Do not place animals and plants in the path of the warm air.(4) Take the air conditioner weight into account and select a place where noise and vibration are less.(5) Select a place so that the warm air and noise from the air conditioner do not disturb neighbours.(6) Provide the space so that the air flow is not blocked. Also for efficient operation, leave open three or the four directions front, rear and both sides.(7) When the outdoor unit will be exposed to strong wind, fasten it with bolts at the places indicated by the arrows.(8) When installing the drain pipe, plug another hole () in the bottom of the outdoor unit with drain cap so there is no water leakage.

Option

3.3 Pipe Length

Type A height: Outdoor Unit above Indoor Unit.Type B height: Outdoor Unit below Indoor Unit.(1) Auxiliary siphons every 7 m.NOTE:In vertical layouts always place an oil trap (small siphon) at the beginning of the vertical stretch. In the case of the heat pump and with the outdoor unit below the indoor unit place siphons every 7 m.

Installation Details

PIPE DETAILS

ORIGIN DISTANCIE EN LINEALS m. Models Load R-407C (kg) Lines (‘‘) 15 m (4 curves) 20 m (6 curves) 30 m (8 curves) 50 m (6 curves) Max. Height (m)

Cool Heat Gas Liq. % Aprox. R-407C Oil % Aprox. R-407C Oil % Aprox. R-407C Oil % Aprox. R-407C Oil Over Under (g) (g) (g) (g) (g) (g) (g) (g) IU IU

050

1,7 2,0 5/8” 3/8” 99 250 --- 98 400 --- 96% 800 20 92 1.500 50

45 20 --- --- --- --- --- --- --- --- --- --- --- --- --- ---

065

1,6 1,9 5/8” 3/8” 98 250 --- 96 400 --- 92 800 --- 87 1.500 50

45 20 3/4” 3/8” 100 300 --- 99 500 --- 97 800 20 94 1.500 50

085

2,3 2,6 3/4” 3/8” 100 300 --- 97 500 --- 94 800 20 89 1.500 50

45 20 7/8” 3/8” 102 300 --- 101 500 --- 99 900 20 96 1.600 50

105

2,8 3,55 3/4” 3/8” 97 300 --- 95 500 --- 92 800 20 85 1.500 50

45 20 7/8” 3/8” 101 300 --- 100 500 --- 98 900 20 94 1.600 50

105T 2,8 3,55

3/4” 3/8” 97 300 --- 95 500 --- 91 800 20 85 1.500 50 45 20

7/8” 3/8” 101 300 --- 100 500 --- 98 900 20 94 1.600 50

130

3,8 4,2 3/4” 1/2” 96 500 --- 93 850 20 88 1.500 50 80 2.800 100

45 20 7/8” 1/2” 102 500 --- 100 900 20 97 1.500 50 91 2.900 100

180*

-- 6,0 7/8” 1/2” 96 900 --- 93 1.500 20 88 2.700 50 80 5.100 100

45 20 7/8” 1/2” 102 900 --- 100 1.500 20 97 2.700 50 91 5.100 100

230*

-- 8,4 1-1/8” 5/8”(1) 97 1.500 --- 95 2.500 --- 92 4.500 50 87 8.500 100

45 20 1-3/8” 5/8”(1) 102 1.800 --- 101 3.000 --- 99 5.400 50 97 10.200 100

(1) It isn’t necessary to isolate this line of liquid.

(* Without loading, value for 7.5 m. Model 180: 120 g/m; Model 230: 200 g/m)

Page 12: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

12

EN

GLI

SH

13

EN

GLI

SH

3.7 POWER

(1) The rate voltage of this product is monophase (230V/1Ph/50 Hz) or triphase (400V/3Ph/50Hz).

(2) Perform wiring work in accordance with standards so that the room air conditioner can be operated safely and positively.

3.8 ELECTRICAL WIRING

(1) Connect the connection cords fi rmly to the terminal block. Imperfect installation may cause a fire.

(2) If the indoor unit connection cord (to the outdoor unit) and power supply are wired incorrectly, the air conditioner may be damaged.

(3) Always connect the ground wire.

3.9 MAINTENANCE INSTRUCTIONS

- Never add oil to the appliance; the compressor is filled with polyaldohol oil, a special oil which cannot tolerate the presence of other oils.

- The instruments used for filling, pressure measure-ments, emptying under vacuum and recovering the fluid, must be compatible and only used for the R-407C fluid.

- The weight of the refrigerant contained in the storage bottle must be checked constantly. Do not use it from the moment the remaining weight is less than 10% of the total weight.

- In the case of a new charge do not use the charging cylinder, use a balance and a dip pipe type R-407C cylinder, charge the weight of R-407C as per the value indicated on the unit’s identification plate (for “split sys-tems”, refer to the installation instructions as the charge must consider the length of the connecting lines).

- The charge must be undertaken in liquid phase.- In the case of leakage, do not complete the charge:

recover the remaining refrigerant or recycling and per-form a total charge. Recovery, recycling or the destruc-tion of the fluid must be done in compliance with the laws in force in the country concerned.

- If the refrigerant circuit is opened, you must avoid the entry of air into the circuit as much as possible, replace the filter drier and perform the “vacuum operation” at a minimum level of 3.0 mbar (static).

3- INSTALLATION

3.5 HEAT INSULATION ON THE PIPE JOINTS

- Put coupler heat insulator on the joints.

AIR PURGE

- Check if the piping connections are secure.- Check that the stems of both 3- way valves are closed

fully.- Operate the vacuum pump and start pump down.- Pump down the system for at least 15 minutes, then

check if the compound pressure gauge reads - 100kPa (- 76 cm Hg, -1bar)

- At the end of pump down, close the low pressure side gauge of the gauge manifold fully and stop the vacuum pump.

- Slowly loosen the valve stem of the 3- way valve.- Firmly tighten both 3- way valves blank cap and the

charging port cap.

3.4 CHECKING THE PIPE CONNECTIONS FOR GAS LEAKING

- For both the indoor and outdoor unit sides, check the joints for gas leaking by the use of a gas leakage detector without fail when the pipes are connected.

ADDITIONAL CHARGE

- Refrigerant suitable for a piping length of 10 m. is char-ged in the indoor unit at the factory.

- When the piping is longer than 10 m., additional char-ging is necessary. (See 3.3)

3.6 GAS LEAKAGE INSPECTION

WARNING!- After connecting the piping, check the joints for gas leakage with gas leak detector.

Page 13: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

12

EN

GLI

SH

13

EN

GLI

SH

4.1 OUTDOOR UNIT DIMENSIONS

4- OUTDOOR UNIT DIMENSIONS

Models 050 / 065

Models 105 / 105T / 130

050 - 065

Liq. 3/8"

Gas 5/8"

A 105 - 105T 130

Liq. 3/8" 1/2"

Gas 3/4" 3/4"

Model 180

085

Liq. 3/8"

Gas 3/4"

Model 085

180

Liq. 1/2"

Gas 7/8"

Page 14: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

14

EN

GLI

SH

15

EN

GLI

SH

Model 230

Units in mm.

4.2 OUTDOOR UNIT LOCATION

Units in mm.

Location for a correct air flow

4.1 OUTDOOR UNIT DIMENSIONS

4- OUTDOOR UNIT DIMENSIONS

Units in mm.

230

Liq. 5/8"

Gas 1 1/8"

Page 15: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

14

EN

GLI

SH

15

EN

GLI

SH

5- WIRING DIAGRAMS

* Don’t forget the earth connection

Riht section mm2 MODELS Power Supply* Up to 25 m. Magnetothermique Differential

(V/Ph/Hz)

Manoeuvre Force Type D I∆n

SDCE/HE 050 D/K/F 230/1/50 1,5 2,5 15 A 0,03 A

SDCE/HE 065 D/K/F 230/1/50 1,5 2,5 20 A 0,03 A

SDCE/HE 085 D/K/F 230/1/50 1,5 4,0 25 A 0,03 A

SDCE/HE 105 D/K/F 230/1/50 1,5 4,0 32 A 0,03 A

SDCE/HE 105T D/K/F 400/3/50 1,5 2,5 10 A 0,03 A

SDHE 130 D 400/3/50 1,5 2,5 16 A 0,03 A

SDHE 180 D 400/3/50 1,5 4,0 16 A 0,03 A

SDHE 230 D 400/3/50 1,5 4,0 30 A 0,03 A

050 / 065 / 085 / 105

The installation of electric assault to the machine should have a Bipolar or Tetrapolar switch according to machine model, (mono-phase or treephase), of at least 3 mm of separation among contacts (norm EN-60335-2-40).

To ensure that this appliance complies with EN-61000-3-11 standard verify that the service current supply capacity is >100A at the interface point.

105T / 130 / 180 230

PAD WIRING DIAGRAM

SERIES 2003

Heat Pump Option

Cooling Only Option

Dry Cool FanHour

Prog.

Dry Auto Cool Heat FanHour

Prog.

Page 16: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

16

EN

GLI

SH

17

EN

GLI

SH

6- CONTROL UNITS DIAGRAMS

6.1 DUCTED INDOOR UNITS

HTR Heater Relay AS Deflector Relay CN4 ON-OFF Switch Conn. 4WV 4-Way Valve Relay M-L-H Fan Relay TFULL Inner Jumper Float ODH Outdoor Unit Fan Relay COMP Compressor Relay ROOM Room Temp. Sensor WTP Condensation Pump Relay F1 Fuse ID I. Unit Coil Sensor CN1 Louver Connector CN6 Receiver Connector OD O. Unit Coil Sensor

6.2 CASSETTE INDOOR UNITS

Page 17: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

16

EN

GLI

SH

17

EN

GLI

SH

HTR Heater Relay AS Deflector Relay CN4 ON-OFF Switch Conn. 4WV 4-Way Valve Relay M-L-H Fan Relay TFULL Inner Jumper Float ODH Outdoor Unit Fan Relay COMP Compressor Relay ROOM Room Temp. Sensor WTP Condensation Pump Relay F1 Fuse ID I. Unit Coil Sensor CN1 Louver Connector CN6 Receiver Connector OD O. Unit Coil Sensor

6- CONTROL UNITS DIAGRAMS

6.3 CEILING-FLOOR INDOOR UNITS

HTR Heater Relay AS Deflector Relay CN4 ON-OFF Switch Conn. 4WV 4-Way Valve Relay M-L-H Fan Relay TFULL Inner Jumper Float ODH Outdoor Unit Fan Relay COMP Compressor Relay ROOM Room Temp. Sensor WTP Condensation Pump Relay F1 Fuse ID I. Unit Coil Sensor CN1 Louver Connector CN6 Receiver Connector OD O. Unit Coil Sensor

6.4 OUTDOOR UNIT (EXCEPT 085 ECO/EHO UNITS)

Page 18: Saunier Duval Clima, S.A. - Pièces de Rechange...1 Saunier Duval, along the lines of its continuous pro-duct quality improvement policy, reserves the rights to modify the specifications

18

EN

GLI

SH

6- CONTROL UNITS DIAGRAMS

6.5 OUTDOOR UNITS 085 ECO/EHO

9002

439

/ V02

+

R S T

Com

p.

V.4

.V. I

N

Pot

. Ven

t..

Pre

sost

ato

V.4

.V. O

UT

Sol

enoi

de

Bob

ina

FAN

230 w

Sen

sor

Pre

sión

de A

spira

ción

L N L N G

L L L L L LCON1

CON2 CON3

TE

RM

OS

TA

TO

(C

ompr

esor

)

V4V

IN

Pot

. VE

NT

.

PRESOSTATO

V4V

OU

T

SO

LEN

.

BO

BIN

A (

Com

pres

or)

L N G

VDR2

VDR1

ICO

C4

L7

C7

C5LED1

R10

R7

L2

TRC1

R15

TRC3TRC2TRC1

R11

R14R13R12

N7N1

RSST

R6R5R4R3

+ -

S S

PRESOS.TERMOS. V.4.V.

+ + + + +LED2 LED3 LED4 LED5

CON4

IC7 IC8 IC9 IC10IC4IC3

TEST

DB1

DB2

R25R24BOBINA

FANLED8LED6 LED7

SOLEN.V.4.V. OUTC11

RA1

+

+ + +

R23

+

R27

R28

+-

S

S

+-

S

SDB3

CON5

C14

C10

C9 C13C12

C18

C15REG1 R22 C16

C17

5VSeñ

al

0V

JP1

LED10

XTAI1

R17

R21

R20

+

NT

C a

spira

ción

NT

C a

mbi

ente

ext

erio

r

Pre

sión

0VSeñ

al

5V

NT

C d

eses

carc

he

Klix

on

230 w

230 w