Santa Rosa-01. Crude Assay Final (1)

Embed Size (px)

Citation preview

  • 8/11/2019 Santa Rosa-01. Crude Assay Final (1)

    1/3

    Units AnalystDateMethodResultTest

    Analytical Report

    Sample Number: 141988-001

    Date Reported: 8/10/2004

    CORE LABORATORIES

    CARRERA 39 NO 168-52/56

    SANTA FE DE BOGOTA, D.C.

    COLUMBIA SOUTH AMERICA,

    Date Received: 5/14/2004

    Description: Petrotesting

    Sample Date:

    Sample ID: Santa Rosa 1 Crude

    Sample as Received

    URIEL SANCHEZ

    CORE LABORATORIES

    8210 Mosley Rd.

    Houston, TX 77075

    713 943-9776 Telephone

    713 943-3846 Facsimile

    Distillation Data

    Deg @ 60 F15.9 DBC5/20/2004ASTM D-287API Gravity

    60/60 Deg. F0.9600 ASTM D-1298Specific Gravity

    mg KOH/g3.02 CB5/19/2004ASTM D-664Acid Number

    WT %2.2 JT5/20/2004ASTM D-6560Asphaltene

    WT %8.31 JM5/19/2004ASTM D-4530Carbon Residue-Micro

    cSt @90F2152 VS5/24/2004ASTM D-445Kinematic Viscosity

    cSt @122 F518 JM6/7/2004ASTM D-445Kinematic Viscosity

    cSt @210 F42.21 VS6/1/2004ASTM D-445Kinematic Viscosity

    cSt @90 f2113 VS6/1/2004ASTM D-445 RCKKinematic Viscosity

    Light Ends Analysis

    LV %0.01 CCASTM D-5134Mod.Methane

    LV %0.01Ethane

    LV %< 0.01Propane

    LV %< 0.01Iso-Butane

    LV %< 0.01N-Butane

    LV %< 0.01Neopentane

    LV %0.01Iso-Pentane

    LV %< 0.01N-Pentane

    LV %0.64Hexanes

    LV %99.32Heptanes Plus

    Metals By ICP

    ppm wt40 KC5/20/2004ASTM D-5708Nickel

    ppm wt3352 CB6/9/2004ASTM D-4629Nitrogen Total by Chemilum.

    Page 1

    The analytical results, opinions or interpretations contained in this report are based upon information and material supplied by the client for whose exclusive and confidential use this report has beenmade. The analytical results, opinions or interpretations expressed represent the best judgment of Core Laboratories. Core Laboratories, however, makes no warranty or representation, express orimplied, of any type, and expressly disclaims same as to the productivity, proper operations or profitableness of any oil, gas, coal, or other mineral, property, well or sand in connection with which suchreport is used or relied upon for any reason whatsoever. This report shall not be reproduced, in whole or in part, without the written approval of Core Laboratories.

  • 8/11/2019 Santa Rosa-01. Crude Assay Final (1)

    2/3

    Units AnalystDateMethodResultTest

    Analytical Report

    Sample Number: 141988-001

    Date Reported: 8/10/2004

    CORE LABORATORIES

    CARRERA 39 NO 168-52/56

    SANTA FE DE BOGOTA, D.C.

    COLUMBIA SOUTH AMERICA,

    Date Received: 5/14/2004

    Description: Petrotesting

    Sample Date:

    Sample ID: Santa Rosa 1 Crude

    Sample as Received

    URIEL SANCHEZ

    CORE LABORATORIES

    8210 Mosley Rd.

    Houston, TX 77075

    713 943-9776 Telephone

    713 943-3846 Facsimile

    Deg F+30 JM5/19/2004ASTM D-97Pour Point

    lbs/1000bbls7.9 DRG8/9/2004ASTM D-3230Salt Content

    LV %< 0.05 DBC8/3/2004ASTM D-4007Sediment & Water

    Simulated Distillation-Crude

    Deg F359 DM5/19/2004ASTM D-5307IBP

    Deg F4995 % off

    Deg F56810 % off

    Deg F62115 % off

    Deg F66920 % offDeg F71425 % off

    Deg F75830 % off

    Deg F80035 % off

    Deg F84040 % off

    Deg F88145 % off

    Deg F92550 % off

    Deg F97155 % off

    Deg F---60 % off

    Deg F---65 % off

    Deg F---70 % off

    Deg F---75 % offDeg F---80 % off

    Deg F---85 % off

    Deg F---90 % off

    Deg F---95 % off

    @ 1000 Deg.58.1% Recovered

    @ 1000 Deg.41.9% Residue

    Page 2

    The analytical results, opinions or interpretations contained in this report are based upon information and material supplied by the client for whose exclusive and confidential use this report has beenmade. The analytical results, opinions or interpretations expressed represent the best judgment of Core Laboratories. Core Laboratories, however, makes no warranty or representation, express orimplied, of any type, and expressly disclaims same as to the productivity, proper operations or profitableness of any oil, gas, coal, or other mineral, property, well or sand in connection with which suchreport is used or relied upon for any reason whatsoever. This report shall not be reproduced, in whole or in part, without the written approval of Core Laboratories.

  • 8/11/2019 Santa Rosa-01. Crude Assay Final (1)

    3/3

    Units AnalystDateMethodResultTest

    Analytical Report

    Sample Number: 141988-001

    Date Reported: 8/10/2004

    CORE LABORATORIES

    CARRERA 39 NO 168-52/56

    SANTA FE DE BOGOTA, D.C.

    COLUMBIA SOUTH AMERICA,

    Date Received: 5/14/2004

    Description: Petrotesting

    Sample Date:

    Sample ID: Santa Rosa 1 Crude

    Sample as Received

    URIEL SANCHEZ

    CORE LABORATORIES

    8210 Mosley Rd.

    Houston, TX 77075

    713 943-9776 Telephone

    713 943-3846 Facsimile

    WT %1.31 CB5/19/2004ASTM D-4294Sulfur, Total by X-Ray Fluoresc.

    Metals By ICP

    ppm wt88 KC5/20/2004ASTM D-5708Vanadium

    Approved By:

    Dan B. Carlson

    Laboratory Supervisor

    Page 3

    The analytical results, opinions or interpretations contained in this report are based upon information and material supplied by the client for whose exclusive and confidential use this report has beenmade. The analytical results, opinions or interpretations expressed represent the best judgment of Core Laboratories. Core Laboratories, however, makes no warranty or representation, express orimplied, of any type, and expressly disclaims same as to the productivity, proper operations or profitableness of any oil, gas, coal, or other mineral, property, well or sand in connection with which suchreport is used or relied upon for any reason whatsoever. This report shall not be reproduced, in whole or in part, without the written approval of Core Laboratories.