4
Same Look. Same Installation. New Technology . It’s all about efficiency. The MagForce™ High Efficiency Motor System offers a 90% motor efficiency rating, which is up to 12% higher than traditional submersible motor designs. With permanent magnet technology, you can now offer an investment payback of less than 2 years in most long- or continuous-run applications*. They get a trusted product, you become their solution provider. *Results based on field trial data. franklinwater.com

Same Look. Same Installation. New Technology · Motor MagForce™ Induction HP Length Weight Length Weight 7.5 25" 105 lbs 24.2" 108 lbs 10 25.4" 116 lbs 15 28" 129 lbs 20 31.2" 126

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Same Look. Same Installation. New Technology · Motor MagForce™ Induction HP Length Weight Length Weight 7.5 25" 105 lbs 24.2" 108 lbs 10 25.4" 116 lbs 15 28" 129 lbs 20 31.2" 126

Same Look. Same Installation.

New Technology.It’s all about efficiency. The MagForce™ High Efficiency

Motor System offers a 90% motor efficiency rating,

which is up to 12% higher than traditional submersible

motor designs. With permanent magnet technology,

you can now offer an investment payback of less

than 2 years in most long- or continuous-run

applications*. They get a trusted product,

you become their solution provider.

*Results based on field trial data.

franklinwater.com

Page 2: Same Look. Same Installation. New Technology · Motor MagForce™ Induction HP Length Weight Length Weight 7.5 25" 105 lbs 24.2" 108 lbs 10 25.4" 116 lbs 15 28" 129 lbs 20 31.2" 126

GROUNDBREAKING EFFICIENCY90% efficiency rating is 10-12% greater than standard induction motor construction. Typical high-duty rate systems can have a payback* of 1 to 2 years. * Field trial data.

SIMPLIFIED INVENTORY MANAGEMENTThree motor sizes cover pump horsepowers ranging from 7.5 to 60. Fewer SKUs simplify your inventory.

SMALLER FOOTPRINTLighter and easier to handle than standard induction motors and, like all submersible motor systems, provides a smaller above ground footprint when compared to line shaft turbines.

HORSEPOWER BOOSTCapable of a 13.6% horsepower boost achieved by increasing the motor’s shaft speed to a true 60 hertz, 3600 rpm**. This allows increased pump output in terms of water volume and total dynamic head pressure without having to pull the system from the well.** Not to exceed the PM motor’s max amp rating.

FEATURES & BENEFITS

A PACKAGED DEALWhen ordered, the motor is shipped with a customized variable frequency drive panel that is preprogrammed for use with a transducer-controlled pump system. This allows simple startup, compatibility with a variety of application types, and is guaranteed to optimize performance and maximize system life. The drive control panel also features real-time monitoring, protection, and customizable application-specific programming software as needed to cover all customer requirements.

SLASH ELECTRICITY CONSUMPTIONSince the motor has rare earth magnets, there is less electrical energy loss, which translates into greater power output per dollar spent on power input. This saves operational costs every time the motor is run; the more it is used, the more can be saved.

 FULLY SUPPORTEDComes fully supported by the industry’s leading Technical Support professionals and Field Service Engineers.

= Unique to the Franklin Electric Experience

Page 3: Same Look. Same Installation. New Technology · Motor MagForce™ Induction HP Length Weight Length Weight 7.5 25" 105 lbs 24.2" 108 lbs 10 25.4" 116 lbs 15 28" 129 lbs 20 31.2" 126

0 $2,500 $5,000 $7,500 $10,000 $12,500 $15,000 $17,500 $20,000 $22,500 $25,000

7.5

10

15

20

25

30

40

50

60

MOT

OR H

ORSE

POW

ER

COST SAVINGS OVER TIME

$1,970

$3,415

$4,730 $7,883

$4,989 $8,315

$5,759 $9,599

$7,716 $12,861

$12,596 $20,993

$14,313

$14,350$4,783

$4,199

$1,920

$1,663

$1,577

$1,138

$657

$2,572

$4,771 $23,856

$23,916

$5,691

$3,283 89% EFFICIENT (vs. 80% for Induction Motor)

92% EFFICIENT (vs. 81% Ind.)

91% EFFICIENT (vs. 82% Ind.)

91% EFFICIENT (vs. 83% Ind.)

91% EFFICIENT (vs. 83% Ind.)

91% EFFICIENCT (vs. 79% Ind.)

92% EFFICIENT (vs. 83% Ind.)

92% EFFICIENT(vs. 84% Ind.)

92% EFFICIENT(vs. 82% Ind.)

After 1 Year

After 3 Years

After 5 Years

KEY

OPERATION COST SAVINGS

The MagForce™ Permanent Magnet Motor System is the smarter choice over line shaft turbine systems and standard submersible induction motors. Here’s why…

• Unlike turbine systems, no line shaft, bearings, or pedestal is needed

• Compact motor provides reduced bearing loads and increased reliability

• Obtain the same HP and pump output in a simplified, compact package

• Results in lower installation and maintenance costs

Shaft

Shaft Bearing

ElectricalSupply

Pump

Motor

Inlet

Impellers

Motor

Housing

Mounting

Drive Shaft

Shaft

Shaft Bearing

ElectricalSupply

Pump

Motor

Inlet

Impellers

Motor

Housing

Mounting

Drive Shaft

LINE SHAFT TURBINEMAGFORCE™ VS

* Based on electric costs of $0.10 USD/kwh running at 100% duty.** Efficiencies generated by Franklin Electric lab tested date.

MOTOR TYPE MagForce™ Line Shaft Submersible Induction

SIZE

COST

NOISE

MAINTENANCE

EFFICIENCY

PERFORMANCE

GOOD:  BETTER:  BEST:

A SMARTER CHOICE

Page 4: Same Look. Same Installation. New Technology · Motor MagForce™ Induction HP Length Weight Length Weight 7.5 25" 105 lbs 24.2" 108 lbs 10 25.4" 116 lbs 15 28" 129 lbs 20 31.2" 126

Mi9046 04-19

POWER DENSITY

Obtain the same HP and pump output in a simplified, compact package. Compare the physical size of the MagForce™ and standard submersible induction systems in the chart below:

Motor MagForce™ Induction

HP Length Weight Length Weight7.5

25" 105 lbs24.2" 108 lbs

10 25.4" 116 lbs15 28" 129 lbs20

31.2" 126 lbs30.6" 145 lbs

25 33.1" 156 lbs30 35.7" 174 lbs40

39.8" 156 lbs40.8" 202 lbs

50 55.3" 300 lbs60 61.3" 330 lbs

Eric McElroy | Co-Owner of Irrigation Pumps and Power, Inc.

I just thought it was a no-brainer to get these out in the field. The most intriguing part is the fact that it’s 10–12 percent more efficient. Energy savings you will attain should pay for itself within a year.”

IDEAL FOR LONG-RUN APPLICATIONS

• Groundwater remediation

• Drainage water level control

• Municipal/Utility water supply

• Construction site dewatering

• High volume and industrial livestock operations

• Mine site dewatering and tank level control

• Well supply geothermal HVAC systems

• Pivot irrigation systems

Mi9046 04-19