28
Safety Safety Officer Officer State Practical State Practical Skill Skill Final Exam Final Exam

Safety Officer

Embed Size (px)

DESCRIPTION

Safety Officer. State Practical Skill Final Exam. Create a Incident Safety Plan State Practical Skill Exam. Using the “Structure Fire Safety Report” complete the 3 page form and submit for evaluation from the information in this presentation - PowerPoint PPT Presentation

Citation preview

Safety OfficerSafety OfficerState Practical Skill State Practical Skill

Final ExamFinal Exam

Create a Incident Safety PlanCreate a Incident Safety PlanState Practical Skill ExamState Practical Skill Exam

Using the “Structure Fire Safety Using the “Structure Fire Safety Report” complete the 3 page form and Report” complete the 3 page form and submit for evaluation from the submit for evaluation from the information in this presentationinformation in this presentation

Forms need to be filled out completely, Forms need to be filled out completely, and clearly printed. and clearly printed.

This skill will be completed in front of This skill will be completed in front of the Evaluator in the classroom.the Evaluator in the classroom.

Each slide will be shown for up to 2 Each slide will be shown for up to 2 minutes eachminutes each

Create a Incident Safety Create a Incident Safety PlanPlan

Students will fill out forms during Students will fill out forms during presentation.presentation.

Students will have 5 minutes at end of Students will have 5 minutes at end of presentation to finish forms.presentation to finish forms.

Students may use a blank sheet of Students may use a blank sheet of paper to take notes during the paper to take notes during the presentation.presentation.

NO DISCUSSION during this examNO DISCUSSION during this exam Students must complete this skill aloneStudents must complete this skill alone

Let’s BeginLet’s Begin

No talking from the students No talking from the students beyond this slidebeyond this slide

Units DispatchedUnits Dispatched

Engines, Truck, and Rescue Engines, Truck, and Rescue Companies are staffed with either 3 or Companies are staffed with either 3 or 4 personnel which includes an officer, 4 personnel which includes an officer, engineer, and firefighters. engineer, and firefighters.

The squad is an ALS unit with one The squad is an ALS unit with one medicmedic

An accountability system is used by An accountability system is used by the fire department. Helmet tags are the fire department. Helmet tags are used for personnel and vehicle. used for personnel and vehicle.

Fire Department Fire Department DispatchDispatch

Incident # 10-255Incident # 10-255Date: Date: use exam dateuse exam date9915 Mount Vernon Road9915 Mount Vernon Road1315 hours – dispatch1315 hours – dispatchResidential fireResidential fire

Side D & A

Units DispatchedUnits Dispatched Engine 1, crew of fourEngine 1, crew of four Engine 2, crew of fourEngine 2, crew of four Truck 4, crew of fourTruck 4, crew of four Engine 3, crew of threeEngine 3, crew of three Rescue 1, crew of fourRescue 1, crew of four Squad 2, crew of twoSquad 2, crew of two Battalion Chief 2 & 4Battalion Chief 2 & 4 ISO Unit #205ISO Unit #205

Fire Department DispatchFire Department Dispatch 1319 hours – first unit on scene (Eng. 1319 hours – first unit on scene (Eng.

2)2)– Confirms working two story wood frame Confirms working two story wood frame

residential fireresidential fire 1321 hours - BC 2 arrives and takes 1321 hours - BC 2 arrives and takes

commandcommand– IC Post setup in the street on side AIC Post setup in the street on side A– Engine 1 & 3 arrive on sceneEngine 1 & 3 arrive on scene

1322 hours – ISO Unit #205 arrives & 1322 hours – ISO Unit #205 arrives & reports to Incident Command post reports to Incident Command post (ICP)(ICP)

Arriving UnitsArriving Units

1322 hrs. Truck 4 arrives1322 hrs. Truck 4 arrives– 17 personnel on the scene17 personnel on the scene

1323 hrs Rescue 1 arrives and 1323 hrs Rescue 1 arrives and assigned RIT on A side of structureassigned RIT on A side of structure

Garage is fully involvedGarage is fully involved Water supply established by Engine 1 Water supply established by Engine 1

hitting the hydrant at the cornerhitting the hydrant at the corner

Side D & C

Arriving UnitsArriving Units IC announce offensive attack in place.IC announce offensive attack in place. Engine 2 crew performing a primary Engine 2 crew performing a primary

search with a 1 ¾” hoseline on first floor. search with a 1 ¾” hoseline on first floor. They enter the structure on the A sideThey enter the structure on the A side

Engine 1 is assigned to deploy a 1 ¾” line Engine 1 is assigned to deploy a 1 ¾” line around to the B side of the structure for around to the B side of the structure for fire attack from B-C cornerfire attack from B-C corner

1327 hrs. Engine 3 crew arrives and are 1327 hrs. Engine 3 crew arrives and are assigned to second floor for search with 1 assigned to second floor for search with 1 ¾” line, they enter on the A side¾” line, they enter on the A side

Side C

Scene ActionScene Action The fire was located on the B end of The fire was located on the B end of

the structure, involving the garage the structure, involving the garage and extends to the second floor and and extends to the second floor and into the attic.into the attic.

1330 hrs. Truck 4 is placed in front of 1330 hrs. Truck 4 is placed in front of structure and crew is lifted above the structure and crew is lifted above the structure to monitor operationsstructure to monitor operations

Side C & B

Scene ActionScene Action

Staging is setup in front of Truck 4Staging is setup in front of Truck 4 Interior crews advise there is no Interior crews advise there is no

basementbasement 1331 hrs BC 4 arrives and assigned 1331 hrs BC 4 arrives and assigned

Operation ChiefOperation Chief 1332 hrs Engine 3 reports heavy fire on 1332 hrs Engine 3 reports heavy fire on

second floorsecond floor Ventilation took place by breaking out Ventilation took place by breaking out

windows on first and second floorswindows on first and second floors

Side B

FIRE

Overview of the area

Hydrant

ICRehab

Staging

N

Incident Incident InformationInformation

Squad 2 is assigned rehab and setup Squad 2 is assigned rehab and setup across the streetacross the street

26 personnel on the scene26 personnel on the scene For this practical, PPE and SCBA are For this practical, PPE and SCBA are

being used satisfactorybeing used satisfactory CO levels being monitored by Truck CO levels being monitored by Truck

4’s crew4’s crew

Incident InformationIncident InformationAt 1335 Engine 2 crew At 1335 Engine 2 crew

reports all clear on first floorreports all clear on first floorAt 1335 hrs IC orders crews At 1335 hrs IC orders crews

to evacuate structure.to evacuate structure.–IC orders operations to IC orders operations to defensive mode.defensive mode.

Master streams deployed Master streams deployed to side A and Dto side A and D

Utilities InformationUtilities Information Utilities on at time of fire, they enter Utilities on at time of fire, they enter

the structure from B side the structure from B side Utilities include electric, natural gasUtilities include electric, natural gas Breaker panel located rear wall in Breaker panel located rear wall in

garagegarage IC calls dispatch to contact utilities IC calls dispatch to contact utilities

for disconnection of servicesfor disconnection of services

Incident InformationIncident Information Structure has engineered floor joistsStructure has engineered floor joists Home built 4 years oldHome built 4 years old Exposures on B and D sides about 20 to Exposures on B and D sides about 20 to

25 feet away. 25 feet away. IC orders Operations to send crews to IC orders Operations to send crews to

rehab after their second air bottle.rehab after their second air bottle.

Incident InformationIncident Information 1336 hrs IC ask for PAR1336 hrs IC ask for PAR 1345 hrs fire knock down on B 1345 hrs fire knock down on B

sideside 1346 hrs. Crews continue 1346 hrs. Crews continue

operations in defensive modeoperations in defensive mode

1352 hrs IC marks fire under 1352 hrs IC marks fire under controlcontrol

Incident InformationIncident Information 1353 IC orders crews to start 1353 IC orders crews to start

overhaul operationsoverhaul operations IC orders Truck 4’s crew to continue IC orders Truck 4’s crew to continue

to monitor CO level inside structure to monitor CO level inside structure during overhaulduring overhaul

All units remains in SCBA until levels All units remains in SCBA until levels reduce to under 35 ppmreduce to under 35 ppm

1359 hrs IC calls for PAR1359 hrs IC calls for PAR

TIME to FINISHTIME to FINISH

You have 5 minutes from now to You have 5 minutes from now to complete the forms and submit them complete the forms and submit them to the Evaluator. to the Evaluator.

On an actual incident the reports On an actual incident the reports would be submitted to the IC and would be submitted to the IC and inserted into the Incident Action Plan.inserted into the Incident Action Plan.

TIME UP!TIME UP! You will be asked to hand the You will be asked to hand the

Evaluator your forms.Evaluator your forms.

Time may be given after all forms Time may be given after all forms have been turned in to discuss the have been turned in to discuss the plans and any issues with the scene. plans and any issues with the scene. This will be with the Instructor while This will be with the Instructor while the Evaluator is evaluating the forms.the Evaluator is evaluating the forms.

What’s Your Call?What’s Your Call? Would you call for an offensive Would you call for an offensive

or defensive attack on this fire? or defensive attack on this fire? Why? Why?

Is there enough resources for Is there enough resources for this fire?this fire?

What are the hazards on this What are the hazards on this fire?fire?

If this home had a basement If this home had a basement would it change your tactics? would it change your tactics?