3
CipherLab RS30 Series Efficiently Delivers Patient Records along with Nurses’ Tasks Everywhere BACKGROUND Case Study Founded in 1900, a China hospital has grown into an innovative and modern hospital with about 7,000 staffs and 4,000 beds to serve more than 4.28 million patients and emergency cases. Being awarded as one of China’s Top 10 Units of Professional Ethics Construction, the hospital has stood out as a leader hospital by its outstanding performance in manifold fields, including medical care, teaching and research. As one of top medical institutions in China, correct and efficient records in HIS system are always the hospital’s highlight in business management. So, many years ago, the hospital adopted the solution in which nurses and doctors respectively adopted mobile computers and iPads to replace paperwork and improved efficiency. However, as time goes by, they have encountered new challenges and problems in nurses’ mobile computers as follow. Heavy Weight : The existing mobile computer weighs 650g, which makes nurses feel fatigued easily while carry- ing it around for tasks everywhere. Small Display : Equipped only 3” display, the mobile computer’s readability can’t allow nurses to check all necessary information at one time and require often scrolling and panning. Poor Data Entry : The sensitivity of the mobile com- puter’s keypads is poor and requires twice or triple-pressing for data entry. In the other hand, the existing vendor is unable to reply all technical issues within 72 hours. The down time caused by un-functional devices is too long for hospital operation and negatively affect nurses’ daily works. Safeguard Patients through HIS System Always Up-to-date

Safeguard Patients through HIS System Always Up-to-date · 2017. 9. 2. · medical care, teaching and research. As one of top medical institutions in China, correct and e˛cient records

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Safeguard Patients through HIS System Always Up-to-date · 2017. 9. 2. · medical care, teaching and research. As one of top medical institutions in China, correct and e˛cient records

CipherLab RS30 Series E�ciently Delivers Patient Records alongwith Nurses’ Tasks Everywhere

BACKGROUND

Case Study

Founded in 1900, a China hospital has grown into an innovative and modern hospital with about 7,000 sta�s and 4,000 beds to serve more than 4.28 million patients and emergency cases. Being awarded as one of China’s Top 10 Units of Professional Ethics Construction, the hospital has stood out as a leader hospital by its outstanding performance in manifold �elds, including medical care, teaching and research.

As one of top medical institutions in China, correct and e�cient records in HIS system are always the hospital’s highlight in business management. So, many years ago, the hospital adopted the solution in which nurses and doctors respectively adopted mobile computers and iPads to replace paperwork and improved e�ciency. However, as time goes by, they have encountered new challenges and problems in nurses’ mobile computers as follow.

Heavy Weight : The existing mobile computer weighs 650g, which makes nurses feel fatigued easily while carry-ing it around for tasks everywhere.

Small Display : Equipped only 3” display, the mobile computer’s readability can’t allow nurses to check all necessary information at one time and require often scrolling and panning.

Poor Data Entry : The sensitivity of the mobile com-puter’s keypads is poor and requires twice or triple-pressing for data entry.

In the other hand, the existing vendor is unable to reply all technical issues within 72 hours. The down time caused by un-functional devices is too long for hospital operation and negatively a�ect nurses’ daily works.

Safeguard Patientsthrough HIS System

Always Up-to-date

Page 2: Safeguard Patients through HIS System Always Up-to-date · 2017. 9. 2. · medical care, teaching and research. As one of top medical institutions in China, correct and e˛cient records

Balance between Lightweightand RuggednessThe RS30 series weighs only approximate 260 g for easy carrying, however, its ruggedness achieves the standard of IP54 and 1.2 m drop resistance to reduce device downtime caused by accidental drops, dust and water splash.

Superior User Experience inBig Display and Multi-touch PanelAllowing nurses to do tasks on 4.7” display with multi-touch panel, the RS30 series supports more viewable data at one time to speed up information checking while the intuitive user experience as smartphone users’ also improves the e�ciency of operation.

Auto-detect Sensibilityfor Touch PanelThe touch panel of RS30 series is high sensible and enables automatic detection for bared �ngertip and latex glove of up to 0.2 mm thickness. As the manual settings are eliminated, it’s convenient for nurses to operate the RS30 series regardless of a latex glove.

Optional Value-added AccessoriesThe RS30 series comes with various accessories to further strengthen its performance. The hospital also adopted its charging cradle and protective boot for their extra bene�ts. The charging cradles are located at every nursing station to always charge the devices out of service, meanwhile, to further prevent miss-placement. Moreover, armed with protective boot, the RS30 series is enhanced to survive from multiple drops at 1.5 m, which closes to the height of bedside infusion. The protective boot minimizes the damages caused by accidental drops due to careless operation while they are scanning the barcodes on infusions.

Therefore, while the new branch with 3,000 beds will be o�cially put into use in the near future, the hospi-tal starts to search for new solutions for the branch where the challenges and problems are supposed to be solved.

PROPOSED SOLUTIONThus, in addition to meet nurses’ inquiries, including ruggedness, working hours, and reliable wireless connectivity, the new solution must be Android-based and improve those unfavorable factors, such as weight, display and data entry.

In the course of new solution searching, the hospi-tal has transferred its HIS system from Windows® to Android operating system, and also develops various apps running on Android mobile device for di�erent tasks. Those tasks, including patient information, treatment and vital sign records, specimen analysis, etc, will be directly accom-plished and managed through the apps on mobile device. It’s also the same device that nurses use to keep HIS system up-to-date in real-time.

CipherLab has proposed RS30 series touch mobile computer, which can fully suit users’ applications with its featured designs.

Page 3: Safeguard Patients through HIS System Always Up-to-date · 2017. 9. 2. · medical care, teaching and research. As one of top medical institutions in China, correct and e˛cient records

For more information, please visit us at www.cipherlab.com, or call your local sales representative.

From the initial stage of consultation to the testing and deployment stages, CipherLab’s instant technical support earns the trust from hospital management. Once the deployment in the new branch is completed undoubtedly, the hospital will continuously adopt the RS30 series to replace existing mobile computers in other 2 branches, and the quantity will totally reach approximate 2000 units. In the meantime, regarding the consistency, the hospital also starts to evaluate the practicability to replace doctors’ iPads with the RS30 series.

NURSE’S COMMENTS ON RS30

“The RS30 minimizes the errors in data entry and enables on-the-spot recording at bedside. It greatly improves the e�ciency.”

ーNurse in nursing station

“Every nurse needs to take care 6 patients on average every day, and repeat numerous information checking and matching. The RS30 is not only easy to carry, but also convenient to check all the informa-tion we need at one time through its big display.”

ーNurse in outpatient department

Nurse’s Working Follow for Specimen CollectionNurse’s Working Follow for Specimen Collection

Download theroute of specimen

collection

Arrive atpatient’sbedside

Sign in HISwith nurse’s ID

Back tonursing station

Go to nextpatient Update HIS

Scan barcodeon patient’swristband

Send barcodeinformationback to HIS

Change tothe correctcontainer

Scan barcode oncontainer, such as tube or blood bag

Collect specimen accordingto the medical information

displayed on RS30

Suspend the specimencollection and call the lab

to check the errors

No

These 2barcodes meet

the recordin HIS

Yes

NoNo

Accomplishthe route

Yes

Yes

NoNo

Nurse checksif she/he took

the wrongcontainer

CipherLab Electronics Trading (Shanghai) Co., Ltd.J Room, 4F, No.728 West Yan’an Rd. Changning District, ShanghaiChina 200050Tel +86 21 3368 0288Toll Free 400 920 0285Fax +86 21 3368 0286

HEADQUARTERSCipherLab Co., Ltd.12F, 333 Dunhua S. Rd., Sec.2Taipei, Taiwan 10669Tel +886 2 8647 1166Fax +886 2 8732 3300www.cipherlab.com

CipherLab USA Inc.2552 Summit Ave.Plano, Texas, USA 75074Tel +1 469 241 9779Toll Free 888 300 9779Fax +1 469 241 0697

CipherLab EuropeFlight Forum 40,5657 DB Eindhoven,The NederlandsTel + 31 (0) 40 295 1510