Smoke Extract FansSafeAir

Issue 3

Page 2: SafeAir

8/14/2019 SafeAir

http://slidepdf.com/reader/full/safeair 2/6

5.000

10.000

15.000

20.000

25.000

 You have to understand fire to master smoke extraction

Perfect smoke extraction in the case of fire not only demands

absolute understanding of the techniques used – it also calls

for an understanding of the nature of fire and the flow of fumes.

Nicotra Gebhardt  sets standards in both aspects – by using

CFD to simulate the flow of smoke, for example.

We can offer you the world’s largest range of mechanical

smoke extraction solutions – compiled in this brand new SafeAir

catalogue. With our wall, roof, radial, axial and pulse fans,

Conflagration gases and fumes emitted by burning 10 kg of each material

 Amount of smoke

in m3 /h

    C   e   l   l   u   l   o   s

   e   p   a   p   e   r

   H   a   r   d   P   V    C

   F   o   a   m

    r   u   b   b   e   r

   K   e   r   o   s   e   n   e   h   e   a   t   i   n   g   o   i   l

   F   l   e   x   i   b

   l   e    f   o   a   m

   P   e

   t   r   o   l   e   u   m

   H   a   r   d   b   o   a   r   d

   B   i   r   c   h   p   l   y   w   o   o   d

    G   R   P

   P   o   l   y   p   r

   o   p   y   l   e   n   e

   L   i   n   o   l   e   u   m

    C   h

   i   p   b   o   a   r   d

we master every form of smoke extraction, whatever the

application. We thereby ensure maximum safety throughout any

building – from the underground car park to the roof – and comply

with all the statutory norms for building fire protection.

Find out about our range of modern smoke extraction systems

in this catalogue and see for yourself what good value intelligent

smoke extract fans from Nicotra Gebhardt are. And above all:

act on it before it is too late! We would be happy to advise you.

Page 3: SafeAir

8/14/2019 SafeAir

http://slidepdf.com/reader/full/safeair 3/6

• • • • • • • • •

• • • •• • •

• • ••• • •

•••••• ••

•••

• • •• • • •

• • • •

• • • •

21

3

4

5

6

4

5

10

5

7

8

3

5

5

5

5   5

4

4

4

     1    4 .     0     0     0

     m     ³     /     h

     3     0     0

      °     C    –      1     2     0

     m     i    n

     3     1 .     0     0     0

     m     ³     /     h

     3     7 .     0     0     0

     m     ³     /     h 

     5     7 .     0     0     0

     m     ³     /     h

     6     5

 .     0     0     0

     m     ³     /     h

     1     5     0 .     0     0     0

     m     ³     /     h 

    4     0     0

      °     C    –      1     2     0

     m     i    n

     6     0     0

      °     C    –      1     2     0

     m     i    n

   R   D   M

   5   6    |   R   D   M

   5   7

   R   W   M

   5   7

   R   E   M

   B   U    |   R   E   M

   B   I

   R   E   R   1   3    |   R   E   R   1   7

    S   L    C    S

   A    G   M

   R    G   M

   P   P    S   P  -    S   y   s   t   e   m

Flow rate Conveying medium Drive type Material

     D     i    r    e    c

     t     d    r     i    v    e

    D    i   s

  c    h   a   r   g 

  e

     B    e     l     t     d    r

     i    v    e

     A     l    u    m

     i    n     i    u    m

      G    a     l    v    a

    n     i    s    e    d     s     t    e    e

     l

      C    o    a     t    e    d

     s     t    e    e     l 

     I    n    s    u     l    a     t     i    n    g  

     c    a    s     i    n    g  

Thrust up to 52 N

 As necessary

Thrust up to 75 N

Page 4: SafeAir

8/14/2019 SafeAir

http://slidepdf.com/reader/full/safeair 4/6

1

6

9

4 3

11

5

7

4

10

9

11

8

2

1 5 9

2

3

6

7

8

11

10

4

Safe smoke extraction solutions from the cellar to the roof!

 genovent  smoke extractor roof fans, RDM 57 SLCS axial smoke extractor fan Smoke detector switchgear

 genovent  smoke extractor roof fan, RDM 56 RWM 57 smoke extractor wall fan Optical smoke detector

Radial smoke ex tractor fan, REM BU/RER 13; 17 AGM Jet fan prevent smoke extractor pulse fan  Duct – F 90

2 Radial fans for PPV system RGM Jetfan prevent smoke extractor pulse fan 

Page 5: SafeAir

8/14/2019 SafeAir

http://slidepdf.com/reader/full/safeair 5/6

21

3

4

5

6

4

5

10

5

7

8

3

5

5

5

5   5

4

4

4

Smoke Extract Roof FansRDM 56/57 genovent ® 

 Vertical discharge, motor separated from airflow,with outlet flaps, snow load class SL 1000

° Specifications

° Relative noise level

° Sample applications

° Accessories

Smoke Extract Wall fansRWM 57 Horizontal discharge, for wall installation,motor separated from airflow

° Specifications

° Relative noise level

° Sample applications° Accessories

Smoke Extract Centrifugal Fanswith direct drive REM REM BU without insulating casingREM BI with insulating casing

° Specifications

° Sample applications

° Accessories

Smoke Extract Centrifugal Fanswith belt drive RER rotavent ® RER 13 – welded, coatedRER 17 – lock-seamed, galvanised

° Specifications

° Technical specifications

° Accessories

 Axial Smoke Extract Fan Unit with direct drivewith direct drive SLCS

 Axial fan based on the pulse fan principle,conflagration gas motor in airflow

° Specifications

° Accessories

Impulse Smoke Extraction FansJetfan AGM 

 Axial fan based on the pulse fan principle,conflagration gas motor in airflow

° AGM 01/11, AGM 02/12, 300 °C – 120 min.

° Specifications AGM 01/11, AGM 02/12

° AGM 06/16 for ventilation of CO-gases

° Specifications AGM 06/16

Positive Pressure Smoke Protection – SystemFor indoor stairwells, corridorsand emergency tunnels

Impulse Smoke Extraction FansRetfan AGM Centrifugal fan based on the pulse fan principle,conflagration gas motor in airflow

° RGM 91, 300 °C – 120 min.

° Specifications RGM 91

° RGM 96 for ventilation of CO-gases

° Specifications RGM 96

Page 6: SafeAir

8/14/2019 SafeAir

http://slidepdf.com/reader/full/safeair 6/6

Nicotra Gebhardt S.p.A 

 Via Modena, 1824040 Zingonia (Bergamo)Italy

Phone +39 (0)35 873 111

Fax +39 (0)35 884 319E-Mail [email protected]

www.nicotra-gebhardt.com

Nicotra Gebhardt GmbH

Gebhardtstrasse 19-2574638 WaldenburgGermany

Phone +49 (0)7942 101 0

Fax +49 (0)7942 101 170E-Mail [email protected]

www.nicotra-gebhardt.com

Nicotra Gebhardt worldwide

SPAIN

Ctra. Alcalá-Villar del Olmo, Km. 2,83028810 Villalbilla-MadridPhone +34 918-846110Fax +34 918-859450E-mail [email protected]

c/.Coso, 67-75, esc. 1.a,1.oB

50001 ZaragozaPhone +34 976-290550Fax +34 976-298127E-mail [email protected]

BELGIUM

Haeghensgoed, 13 - 00/019270 LaarnePhone +32 (0)9-336-00-01Fax +32 (0)9-336-00-05E-mail [email protected]

FRANCE

8 chemin des Mûriers BP 32469745 Genas cedex.Phone 0033 (0)472790120Fax 0033 (0)472790121E-mail [email protected]

SWEDEN

Box 237Kraketorpsgatan 3043123 MölndalPhone 0046 31-874540Fax 0046 31-878590E-mail [email protected]://www.nicotra-gebhardt.se/

GREAT BRITAIN

Unit D, Rail Mill WayParkgate Business Park RotherhamSouth YorkshireS62 6JQPhone +044 01709-780760Fax +044 01709-780762E-mail [email protected]

Monarch House1-7 Smyth RoadBedminsterBristolPhone +44 (0)870 043-5207Fax +44 (0)870 043-5212E-mail [email protected] http://www.kiloheat.co.uk/

MALAYSIA

Lot 1799, Jalan Balakong Taman Perindustrian Bukit Belimbing43300 Seri KembanganSelangorPhone +603 8961-2588Fax +603 8961-8337E-mail [email protected]

THAILAND

6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road,Kwang Jomthong, Khet Jomthong,Bangkok 10150Phone +662 476-1823-6Fax +662 476-1827E-mail [email protected]

SINGAPORE

No. 15 West Coast Highway# 04-08 Pasir Panjang BuildingSingapore 117861Phone (065) 6265-1522Fax (065) 6265-2400E-mail [email protected]

 AUSTRALIA 

47 Jesica Road,Campbellfield, VIC 3061Phone +613 9357-7464Fax +613 9357-8700E-mail [email protected]

INDIA 

Plot no 28f, Sector-31Kasna, Greater Noida-201308U.P. INDIA Phone +91 0120-4203400Fax +91 0120-4203401E-mail [email protected]

CHINA 

88 Tai‘An Road, XinQiao, ShiJi, PanyuGuangzhou 511450

PR CHINAPhone +86 (0)20-39960570Fax +86 (0)20-39960569E-mail [email protected]

UNITED STATES

1503 W. Misty Breeze CirKaysville, UT 84037Phone 001(801) 544-9909Fax 001(801) 315-9400Mobile 001(801) 694-0353E-mail [email protected]

   E   N  -   S   E   F   2 .   1

  –   P   D   F   1  -   0   9 .   2

   0   1   0