Click here to load reader
Upload
talianu-iulia
View
212
Download
0
Embed Size (px)
Citation preview
8/14/2019 SafeAir
http://slidepdf.com/reader/full/safeair 1/6
Smoke Extract FansSafeAir
Issue 3
8/14/2019 SafeAir
http://slidepdf.com/reader/full/safeair 2/6
5.000
10.000
15.000
20.000
25.000
You have to understand fire to master smoke extraction
Perfect smoke extraction in the case of fire not only demands
absolute understanding of the techniques used – it also calls
for an understanding of the nature of fire and the flow of fumes.
Nicotra Gebhardt sets standards in both aspects – by using
CFD to simulate the flow of smoke, for example.
We can offer you the world’s largest range of mechanical
smoke extraction solutions – compiled in this brand new SafeAir
catalogue. With our wall, roof, radial, axial and pulse fans,
Conflagration gases and fumes emitted by burning 10 kg of each material
Amount of smoke
in m3 /h
C e l l u l o s
e p a p e r
H a r d P V C
F o a m
r u b b e r
K e r o s e n e h e a t i n g o i l
F l e x i b
l e f o a m
P e
t r o l e u m
H a r d b o a r d
B i r c h p l y w o o d
G R P
P o l y p r
o p y l e n e
L i n o l e u m
C h
i p b o a r d
we master every form of smoke extraction, whatever the
application. We thereby ensure maximum safety throughout any
building – from the underground car park to the roof – and comply
with all the statutory norms for building fire protection.
Find out about our range of modern smoke extraction systems
in this catalogue and see for yourself what good value intelligent
smoke extract fans from Nicotra Gebhardt are. And above all:
act on it before it is too late! We would be happy to advise you.
8/14/2019 SafeAir
http://slidepdf.com/reader/full/safeair 3/6
• • • • • • • • •
• • • •• • •
• • ••• • •
•••••• ••
•
•••
• • •• • • •
• • • •
•
•
•
•
•
• • • •
21
3
4
5
6
4
5
10
5
7
8
3
5
5
5
5 5
4
4
4
1 4 . 0 0 0
m ³ / h
3 0 0
° C – 1 2 0
m i n
3 1 . 0 0 0
m ³ / h
3 7 . 0 0 0
m ³ / h
5 7 . 0 0 0
m ³ / h
6 5
. 0 0 0
m ³ / h
1 5 0 . 0 0 0
m ³ / h
4 0 0
° C – 1 2 0
m i n
6 0 0
° C – 1 2 0
m i n
R D M
5 6 | R D M
5 7
R W M
5 7
R E M
B U | R E M
B I
R E R 1 3 | R E R 1 7
S L C S
A G M
R G M
P P S P - S y s t e m
Flow rate Conveying medium Drive type Material
D i r e c
t d r i v e
D i s
c h a r g
e
B e l t d r
i v e
A l u m
i n i u m
G a l v a
n i s e d s t e e
l
C o a t e d
s t e e l
I n s u l a t i n g
c a s i n g
Thrust up to 52 N
As necessary
Thrust up to 75 N
8/14/2019 SafeAir
http://slidepdf.com/reader/full/safeair 4/6
1
6
9
4 3
11
5
7
4
10
9
11
8
2
1 5 9
2
3
6
7
8
11
10
4
Safe smoke extraction solutions from the cellar to the roof!
genovent smoke extractor roof fans, RDM 57 SLCS axial smoke extractor fan Smoke detector switchgear
genovent smoke extractor roof fan, RDM 56 RWM 57 smoke extractor wall fan Optical smoke detector
Radial smoke ex tractor fan, REM BU/RER 13; 17 AGM Jet fan prevent smoke extractor pulse fan Duct – F 90
2 Radial fans for PPV system RGM Jetfan prevent smoke extractor pulse fan
8/14/2019 SafeAir
http://slidepdf.com/reader/full/safeair 5/6
21
3
4
5
6
4
5
10
5
7
8
3
5
5
5
5 5
4
4
4
Smoke Extract Roof FansRDM 56/57 genovent ®
Vertical discharge, motor separated from airflow,with outlet flaps, snow load class SL 1000
° Specifications
° Relative noise level
° Sample applications
° Accessories
Smoke Extract Wall fansRWM 57 Horizontal discharge, for wall installation,motor separated from airflow
° Specifications
° Relative noise level
° Sample applications° Accessories
Smoke Extract Centrifugal Fanswith direct drive REM REM BU without insulating casingREM BI with insulating casing
° Specifications
° Sample applications
° Accessories
Smoke Extract Centrifugal Fanswith belt drive RER rotavent ® RER 13 – welded, coatedRER 17 – lock-seamed, galvanised
° Specifications
° Technical specifications
° Accessories
Axial Smoke Extract Fan Unit with direct drivewith direct drive SLCS
Axial fan based on the pulse fan principle,conflagration gas motor in airflow
° Specifications
° Accessories
Impulse Smoke Extraction FansJetfan AGM
Axial fan based on the pulse fan principle,conflagration gas motor in airflow
° AGM 01/11, AGM 02/12, 300 °C – 120 min.
° Specifications AGM 01/11, AGM 02/12
° AGM 06/16 for ventilation of CO-gases
° Specifications AGM 06/16
Positive Pressure Smoke Protection – SystemFor indoor stairwells, corridorsand emergency tunnels
Impulse Smoke Extraction FansRetfan AGM Centrifugal fan based on the pulse fan principle,conflagration gas motor in airflow
° RGM 91, 300 °C – 120 min.
° Specifications RGM 91
° RGM 96 for ventilation of CO-gases
° Specifications RGM 96
8/14/2019 SafeAir
http://slidepdf.com/reader/full/safeair 6/6
Nicotra Gebhardt S.p.A
Via Modena, 1824040 Zingonia (Bergamo)Italy
Phone +39 (0)35 873 111
Fax +39 (0)35 884 319E-Mail [email protected]
www.nicotra-gebhardt.com
Nicotra Gebhardt GmbH
Gebhardtstrasse 19-2574638 WaldenburgGermany
Phone +49 (0)7942 101 0
Fax +49 (0)7942 101 170E-Mail [email protected]
www.nicotra-gebhardt.com
Nicotra Gebhardt worldwide
SPAIN
Ctra. Alcalá-Villar del Olmo, Km. 2,83028810 Villalbilla-MadridPhone +34 918-846110Fax +34 918-859450E-mail [email protected]
c/.Coso, 67-75, esc. 1.a,1.oB
50001 ZaragozaPhone +34 976-290550Fax +34 976-298127E-mail [email protected]
BELGIUM
Haeghensgoed, 13 - 00/019270 LaarnePhone +32 (0)9-336-00-01Fax +32 (0)9-336-00-05E-mail [email protected]
FRANCE
8 chemin des Mûriers BP 32469745 Genas cedex.Phone 0033 (0)472790120Fax 0033 (0)472790121E-mail [email protected]
SWEDEN
Box 237Kraketorpsgatan 3043123 MölndalPhone 0046 31-874540Fax 0046 31-878590E-mail [email protected]://www.nicotra-gebhardt.se/
GREAT BRITAIN
Unit D, Rail Mill WayParkgate Business Park RotherhamSouth YorkshireS62 6JQPhone +044 01709-780760Fax +044 01709-780762E-mail [email protected]
Monarch House1-7 Smyth RoadBedminsterBristolPhone +44 (0)870 043-5207Fax +44 (0)870 043-5212E-mail [email protected] http://www.kiloheat.co.uk/
MALAYSIA
Lot 1799, Jalan Balakong Taman Perindustrian Bukit Belimbing43300 Seri KembanganSelangorPhone +603 8961-2588Fax +603 8961-8337E-mail [email protected]
THAILAND
6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road,Kwang Jomthong, Khet Jomthong,Bangkok 10150Phone +662 476-1823-6Fax +662 476-1827E-mail [email protected]
SINGAPORE
No. 15 West Coast Highway# 04-08 Pasir Panjang BuildingSingapore 117861Phone (065) 6265-1522Fax (065) 6265-2400E-mail [email protected]
AUSTRALIA
47 Jesica Road,Campbellfield, VIC 3061Phone +613 9357-7464Fax +613 9357-8700E-mail [email protected]
INDIA
Plot no 28f, Sector-31Kasna, Greater Noida-201308U.P. INDIA Phone +91 0120-4203400Fax +91 0120-4203401E-mail [email protected]
CHINA
88 Tai‘An Road, XinQiao, ShiJi, PanyuGuangzhou 511450
PR CHINAPhone +86 (0)20-39960570Fax +86 (0)20-39960569E-mail [email protected]
UNITED STATES
1503 W. Misty Breeze CirKaysville, UT 84037Phone 001(801) 544-9909Fax 001(801) 315-9400Mobile 001(801) 694-0353E-mail [email protected]
E N - S E F 2 . 1
– P D F 1 - 0 9 . 2
0 1 0