2
s e c u r e p o w e r Uninterruptible Power Supplies 200 Series 10KVA 15KVA 20KVA 30KVA SA Uninterruptible Power Supplies Features: 3 Phase Input / 1 Phase Output (6kVA - 30kVA) state of the art, PWM and IGBT technology, producing microprocessor controlled pure sinewave output to critical loads. Tescom 200 Series are, True Online, Double Conversion UPS Systems, manufactured with the Galvanic isolation transformer at the inverter output. Efficiency up to 91%. Static by-pass. LCD panel providing detailed information. 128 recorded event history. RS232 and dry contacts for communication and remote monitoring. Input/Output customization, possible. Compatible with international standards. 5 year full warranty. Supply of spare parts guaranteed for 10 years. Designed and manufactured under TUV-ISO9001 certification.

SA Uninterruptible Power Supplies 200 Series - Tescom SAtescomsa.co.za/downloads/Tescom-200-10-30kVA-series.pdf · Uninterruptible Power Supplies 200 Series ... 230/400 Vac 3 phase

Embed Size (px)

Citation preview

secure

pow

er

Uninterruptible Power Supplies

200 Series10KVA 15KVA 20KVA 30KVA

S AUninterruptible Power Supplies

Features:

3 Phase Input / 1 Phase Output(6kVA - 30kVA)

state of the art, PWM and IGBT technology, producing microprocessor controlled puresinewave output to critical loads.

Tescom 200 Series are, True Online, Double Conversion UPS Systems, manufactured with the

Galvanic isolation transformer at the inverter output.

Efficiency up to 91%.

Static by-pass.

LCD panel providing detailed information.

128 recorded event history.

RS232 and dry contacts for communication and remote monitoring.

Input/Output customization, possible.

Compatible with international standards.

5 year full warranty.

Supply of spare parts guaranteed for 10 years.

Designed and manufactured under TUV-ISO9001 certification.

Uninterruptible Power Supplies

All products are manufactured to the following standards:

R

ISO 9001

MANAGEMENT SERVICE

www.tescomsa.co.za [email protected]

200 Series10KVA 15KVA 20KVA 30KVA

S AUninterruptible Power Supplies

S AUninterruptible Power Supplies

* Due to continuous product improvements specifications are subject to change without further notice.

Unit 1 Blue Sky Factories,19 Drakensberg Drive, Longmeadow West Business Park1609Tel: +27 11 608 1221Fax: 086 550 5712

AccessoriesNet Agent II :

Rm2000 :

ML-100 :

US-4 and US-8 :

SNMP (int. card or ext. with adapter)

Remote monitoring panel

Communication port multiplier

Multiple server shut-down unit

MD-1 :

MD-NET :

RSC-24:

Modbus over RS485 interface

Modbus over TCP interface

RS232/RS485 converter

MODEL

Power (kVA)

Power (kW)

Weight without Batteries (kg)

210

10

7

125

3x20A

215

15

10,5

190

3x30A

220

20

14

200

3x40A

230

30

21

230

3x60A

230/400 Vac 3 phase + N, +/- 15%

0,7

230 Vac, +/- 1%

50 Hz (60Hz on request)

Electronic short circuit protection

< 3%

Dry contacts & RS232

Sealed Lead Acid - Maintenance Free

Automatic circuit breaker

Optional Automatic every 72 hrs

T-mon UPS Management Software

Galvanic isolation transformer at the input

<10% (with 18 Pulse rectifier) Except 206 & 207

Maintenance by-pass switch for complete isolation (for 206, 207 & 210)

<5% (with 18 Pulse rectifier + filter) Except 206 & 207

N+1 Systems (hot standby, redundant, symetric parallel)

0,95 - 0,98 (with 18 Pulse rectifier)

In some 18Pulse applications, the standard chassis dimensions may change

0 C - 40 C

90% max.

IP20

< 1000m above sea level

3:1

100% - 125% load: 10 min

125% - 150% load: 1 min

> 150% load: by pass

86-90%

30

405 VDC

300 VDC

< 55 dBA

1225x505x650

20

270 VDC

200 VDC

< 50 dBA

950x265x740

Internal

+/- 2% (line synchronized)

+/- 0,2% (free running)

230 Vac, +/- 10%

50 Hz (60Hz on request), +/- 5%

EN50091-2 Class A

INPUT

OUTPUT

BATTERIES

GENERAL

OPTIONS

Voltage

Power factor

Voltage

Frequency

Short circuit protection

Total harmonic distortion (THD)

Communication

Type

Battery protection

Battery test

Software

Input transformer

Input THD *

MBS

Parallel operation

Input Power Factor *

(*)

Temperature range

Relative humidty (non condensed)

Protection degree

Altitude

Crest factor

Overload protection

Efficiency at 100% load

Number of Batteries

Float Charging voltage

End of discharge voltage

Acoustic noise

Dimensions (mm) HxWxD

Battery cabniet

Frequency tolerance

By-pass Voltage

Current

Input frequency

EMI

25 CBattery ambient temperature C