1591
FTOS Command Line Reference Guide for the S4810 System FTOS 8.3.12.0 Publication Date: August 2012

S4810 FTOS Command Reference Guide, FTOS 8.3.12€¦ · 28/08/2012  · guide contains a chapter with a list of the RFCs and MIBs (management information base files) supported. Audience

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

  • FTOS Command Line ReferenceGuide for the S4810 System

    FTOS 8.3.12.0

    Publication Date: August 2012

  • Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

    CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

    WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

    Information in this publication is subject to change without notice.© 2012 Dell Force10. All rights reserved.

    Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.

    Trademarks used in this text: Dell™, the DELL logo, Dell Precision™, OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, KACE™, FlexAddress™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®, Xeon®, Core™ and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD® is a registered trademark and AMD Opteron™, AMD Phenom™, and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, MS-DOS® and Windows Vista® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat Enterprise Linux® and Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® is a registered trademark and SUSE ™ is a trademark of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware®, Virtual SMP®, vMotion®, vCenter®, and vSphere® are registered trademarks or trademarks of VMWare, Inc. in the United States or other countries.

    Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

    August 2012

  • | 3

    1 About this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Information Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

    2 CLI Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Accessing the Command Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Multiple Configuration Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Navigating the Command Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Obtaining Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Using the Keyword No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Filtering show Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

    Displaying All Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22Filtering Command Output Multiple Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

    Command Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23EXEC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23EXEC Privilege Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23CONFIGURATION Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23INTERFACE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23LINE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24TRACE-LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24MAC ACCESS LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25IP ACCESS LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25ROUTE-MAP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25PREFIX-LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26AS-PATH ACL Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26IP COMMUNITY LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26REDIRECT-LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26SPANNING TREE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Per-VLAN SPANNING TREE Plus Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27RAPID SPANNING TREE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27MULTIPLE SPANNING TREE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28PROTOCOL GVRP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28ROUTER OSPF Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28ROUTER RIP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28ROUTER ISIS Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29ROUTER BGP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29VLT DOMAIN Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

    Determining the Chassis Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

    3 File Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31Basic File Management Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

  • 4 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Upgrading the C-Series FPGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63

    4 Control and Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

    5 802.1ag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155

    6 802.1X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168

    7 Access Control Lists (ACL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183Commands Common to all ACL Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183Common IP ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186Standard IP ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190Extended IP ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198Common MAC Access List Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233Standard MAC ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236Extended MAC ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241IP Prefix List Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247Route Map Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252AS-Path Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271IP Community List Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275

    8 Bidirectional Forwarding Detection (BFD). . . . . . . . . . . . . . . . . . . . . . . .281Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .281Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .281

    9 Border Gateway Protocol IPv4 (BGPv4) . . . . . . . . . . . . . . . . . . . . . . . . .297Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297BGPv4 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .298MBGP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383BGP Extended Communities (RFC 4360) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .409

    10 Bare Metal Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .419Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .419Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .419

  • | 5

    11 Content Addressable Memory (CAM) . . . . . . . . . . . . . . . . . . . . . . . . . . .423Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .423CAM Profile Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .423

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .424CAM IPv4flow Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .437CAM Layer 2 ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .440

    12 Control Plane Policing (CoPP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445

    13 Data Center Bridging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .451Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .451

    DCB Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .451PFC Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .451ETS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .452DCBX Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .452

    14 Dynamic Host Configuration Protocol (DHCP) . . . . . . . . . . . . . . . . . . . .485Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .485Commands to Configure the System to be a DHCP Server . . . . . . . . . . . . . . . . . . . . .485Commands to Configure Secure DHCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .492

    15 Equal Cost Multi-Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501

    16 FIPS Cryptography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .511Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .511

    FIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .511

    17 FIP Snooping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .517Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .517

    FIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .517

    18 Force10 Resilient Ring Protocol (FRRP) . . . . . . . . . . . . . . . . . . . . . . . .529Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .529Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .529

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .529

  • 6 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om 19 GARP VLAN Registration (GVRP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537

    Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .538

    20 High Availability (HA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .549Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .549Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .549

    21 ICMP Message Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .561

    22 Internet Group Management Protocol (IGMP) . . . . . . . . . . . . . . . . . . . .563Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .563IGMP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .563

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .563IGMP Snooping Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .575

    Important Points to Remember for IGMP Snooping . . . . . . . . . . . . . . . . . . . . . . . .575Important Points to Remember for IGMP Querier . . . . . . . . . . . . . . . . . . . . . . . . . .576

    23 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .581Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .581Basic Interface Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .581Port Channel Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .640Time Domain Reflectometer (TDR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .651

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .651UDP Broadcast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .653

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .653

    24 IPv4 Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .657Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .657Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .657

    25 IPv6 Access Control Lists (IPv6 ACLs) . . . . . . . . . . . . . . . . . . . . . . . . .715Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .715

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .715IPv6 ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .716IPv6 Route Map Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .743

    26 IPv6 Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .749Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .749Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .749

  • | 7

    27 IPv6 Border Gateway Protocol (IPv6 BGP). . . . . . . . . . . . . . . . . . . . . . .769Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .769IPv6 BGP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .769IPv6 MBGP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .836

    28 iSCSI Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .863Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .863

    29 Intermediate System to Intermediate System (IS-IS) . . . . . . . . . . . . . . .871Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .871Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .871

    30 Link Aggregation Control Protocol (LACP) . . . . . . . . . . . . . . . . . . . . . . .917Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .917Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .917

    31 Layer 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .925Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .925MAC Addressing Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .925Virtual LAN (VLAN) Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .946Far-End Failure Detection (FEFD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .956

    Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .956Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .957

    32 Link Layer Discovery Protocol (LLDP) . . . . . . . . . . . . . . . . . . . . . . . . . .965Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .965Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .965LLDP-MED Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .975

    33 Multicast Source Discovery Protocol (MSDP). . . . . . . . . . . . . . . . . . . . .985Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .985Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .985

    34 Multiple Spanning Tree Protocol (MSTP) . . . . . . . . . . . . . . . . . . . . . . . .997Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .997Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .997

    35 Multicast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1013Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1013IPv4 Multicast Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1013IPv6 Multicast Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1023

  • 8 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om 36 Neighbor Discovery Protocol (NDP) . . . . . . . . . . . . . . . . . . . . . . . . . . .1029

    Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1029Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1029

    37 Object Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1037Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1037IPv4 Object Tracking Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1037IPv6 Object Tracking Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1049

    38 Open Shortest Path First (OSPFv2) . . . . . . . . . . . . . . . . . . . . . . . . . . .1055Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1055OSPFv2 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1055

    39 PIM-Sparse Mode (PIM-SM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1117Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1117IPv4 PIM-Sparse Mode Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1117IPv6 PIM-Sparse Mode Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1141

    40 Port Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1153Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1153Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1153

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1153

    41 Private VLAN (PVLAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1159Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1159Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1159

    Private VLAN Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1159

    42 Per-VLAN Spanning Tree Plus (PVST+) . . . . . . . . . . . . . . . . . . . . . . .1169Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1169Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1169

    43 Quality of Service (QoS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1183Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1183Global Configuration Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1183Per-Port QoS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1184Policy-Based QoS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1194

    Important Points to Remember — multicast-bandwidth option . . . . . . . . . . . . . . .1209Queue-Level Debugging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1233

  • | 9

    44 Routing Information Protocol (RIP) . . . . . . . . . . . . . . . . . . . . . . . . . . . .1243Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1243Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1243

    45 Remote Monitoring (RMON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1263Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1263Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1263

    46 Rapid Spanning Tree Protocol (RSTP) . . . . . . . . . . . . . . . . . . . . . . . . .1277Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1277Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1277

    47 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1289Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1289Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1289AAA Accounting Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1290Authorization and Privilege Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1293Authentication and Password Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1297RADIUS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1310TACACS+ Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1316Port Authentication (802.1X) Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1319

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1320SSH Server and SCP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1329Trace List Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1344Secure DHCP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1354

    48 Service Provider Bridging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1361Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1361Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1361

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1361

    49 sFlow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1367Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1367

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1367Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1368

    50 Simple Network Management Protocol and Syslog . . . . . . . . . . . . . . .1379Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1379SNMP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1379

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1380Syslog Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1397

  • 10 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om 51 S-Series Stacking Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1411

    Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1411Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1411

    52 Storm Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1421Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1421Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1421

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1421

    53 Spanning Tree Protocol (STP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1431Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1431Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1431

    54 System Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1443Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1443Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1443

    55 VLAN Stacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1461Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1461Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1461

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1461

    56 S4810 u-Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1473Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1473Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1473

    57 Uplink Failure Detection (UFD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1477Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1477Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1477

    58 Virtual Link Trunking (VLT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1487Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1487Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1487

    59 Virtual Router Redundancy Protocol (VRRP) . . . . . . . . . . . . . . . . . . . .1499Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1499IPv4 VRRP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1499IPv6 VRRP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1512

    60 S-Series Debugging and Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . .1519Offline Diagnostic Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1519

  • | 11

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1519Buffer Tuning Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1522Hardware Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1527

    61 SNMP Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1539

    63 Command Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1581

  • 12 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om

  • About this Guide | 13

    1About this Guide

    This book provides information on the FTOS Command Line Interface (CLI). It includes some information on the protocols and features found in FTOS and on the Dell Force10 systems supported by FTOS (C-Series c, E-Series e, and S-Series s).

    This chapter includes:

    • Objectives• Audience• Conventions• Related Documents

    ObjectivesThis document is intended as a reference guide for the FTOS command line interface (CLI) commands, with detailed syntax statements, along with usage information and sample output.

    For details on when to use the commands, refer to the FTOS Configuration Guide. That guide contains a chapter with a list of the RFCs and MIBs (management information base files) supported.

    AudienceThis document is intended for system administrators who are responsible for configuring or maintaining networks. This guide assumes you are knowledgeable in Layer 2 and Layer 3 networking technologies.

  • 14 | About this Guide

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Conventions

    This document uses the following conventions to describe command syntax:

    Information SymbolsTable 1-1 describes symbols contained in this guide.

    Related DocumentsFor more information about the system, refer to the following documents:

    Convention Description

    keyword Keywords are in bold and should be entered in the CLI as listed.parameter Parameters are in italics and require a number or word to be entered in the CLI.{X} Keywords and parameters within braces must be entered in the CLI.[X] Keywords and parameters within brackets are optional.x | y Keywords and parameters separated by bar require you to choose one.x||y Keywords and parameters separated by a double bar enables you to choose any or all of them.

    Table 1-1. Information Symbols

    Symbol Brief Description

    Note This symbol signals important operational information.

    Caution This symbol signals information about situations that could result in equipment damage or loss of data.

    Warning This symbol signals information about hardware handling that could result in injury.

    c C-Series This symbol indicates that the selected feature is supported on the C-Series.

    e E-Series This symbol indicates that the selected feature is supported on the E-Series TeraScale AND E-Series ExaScale.

    et E-SeriesTeraScale

    This symbol indicates that the selected feature is supported on the E-Series TeraScale platform only.

    ex E-SeriesExaScale

    This symbol indicates that the selected feature is supported on the E-Series ExaScale platform only.

    s S-Series This symbol indicates that the selected feature is supported on the S-Series.

  • About this Guide | 15

    • FTOS Configuration Guide • Installation and maintenance guides for your system• Release Notes for your system and FTOS version

  • 16 | About this Guide

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om

  • CLI Basics | 17

    2CLI Basics

    This chapter describes the command structure and command modes. FTOS commands are in a text-based interface that allows you to use launch commands, change the command modes, and configure interfaces and protocols.

    This chapter covers the following topics:

    • Accessing the Command Line• Multiple Configuration Users• Navigating the Command Line Interface• Obtaining Help• Using the Keyword No• Filtering show Commands• Command Modes

    Accessing the Command LineWhen the system boots successfully, you are positioned on the command line in the EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session. When you Telnet into the switch, you are prompted to enter a login name and password.

    The following text is an example of a successful Telnet login session.

    telnet 172.31.1.53Trying 172.31.1.53...Connected to 172.31.1.53.Escape character is '^]'.Login: usernamePassword: FTOS>

    Once you log into the switch, the prompt provides you with current command-level information (refer to Table 2-1).

  • 18 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Multiple Configuration Users

    When a user enters the CONFIGURATION mode and another user(s) is already in that configuration mode, FTOS generates an alert warning message similar to the following:

    FTOS#conf

    % Warning: The following users are currently configuring the system:

    User "" on line console0 User "admin" on line vty0 ( 123.12.1.123 ) User "admin" on line vty1 ( 123.12.1.123 ) User "Irene" on line vty3 ( 123.12.1.321 )FTOS#conf

    When another user enters the CONFIGURATION mode, FTOS sends a message similar to the following, where the user in this case is “admin” on vty2:

    % Warning: User "admin" on line vty2 "172.16.1.210" is in configuration

    Navigating the Command Line InterfaceThe Command Line Interface (CLI) prompt displayed by FTOS is comprised of:

    • “hostname”— the initial part of the prompt, “FTOS” by default. You can change it with the hostname command, as described in hostname.

    • The second part of the prompt, reflecting the current CLI mode, as shown in Table 2-1.

    The CLI prompt changes as you move up and down the levels of the command structure. Table 2-1 lists the prompts and their corresponding command levels, called modes. Starting with the CONFIGURATION mode, the command prompt adds modifiers to further identify the mode. The command modes are explained in Command Modes.

    Note: Some of the following modes are not available on C-Series or S-Series.

    Table 2-1. Command Prompt and Corresponding Command Mode

    Prompt CLI Command Mode

    FTOS> EXEC

    FTOS# EXEC Privilege

    FTOS(conf)# CONFIGURATION

  • CLI Basics | 19

    Obtaining HelpAs soon as you are in a command mode there are several ways to access help.

    • To obtain a list of keywords at any command mode, do the following:

    FTOS(conf-if)#FTOS(conf-if-gi-0/0)#FTOS(conf-if-te-0/0)#FTOS(conf-if-fo-0/0)#FTOS(conf-if-lo-0)#FTOS(conf-if-nu-0)#FTOS(conf-if-po-0)#FTOS(conf-if-vl-0)#FTOS(conf-if-so-0/0)#FTOS(conf-if-ma-0/0)#FTOS(conf-if-range)#

    INTERFACE

    FTOS(config-ext-nacl)#FTOS(config-std-nacl)#

    IP ACCESS LIST

    FTOS(config-line-aux)#FTOS(config-line-console)#FTOS(config-line-vty)#

    LINE

    FTOS(config-ext-macl)#FTOS(config-std-macl)#

    MAC ACCESS LIST

    FTOS(config-mon-sess)# MONITOR SESSION

    FTOS(config-span)# STP

    FTOS(config-mstp)# MULTIPLE SPANNING TREE

    FTOS(config-pvst)# Per-VLAN SPANNING TREE Plus

    FTOS(config-rstp)# RAPID SPANNING TREE

    FTOS(config-gvrp)# PROTOCOL GVRP

    FTOS(config-route-map)# ROUTE-MAP

    FTOS(conf-nprefixl)# PREFIX-LIST

    FTOS(conf-router_rip)# ROUTER RIP

    FTOS(conf-redirect-list)# REDIRECT

    FTOS(conf-router_bgp)# ROUTER BGP

    FTOS(conf-router_ospf)# ROUTER OSPF

    FTOS(conf-router_isis)# ROUTER ISIS

    FTOS(conf-trace-acl)# TRACE-LIST

    FTOS(config-vlt-domain) VLT DOMAIN

    Table 2-1. Command Prompt and Corresponding Command Mode

    Prompt CLI Command Mode

  • 20 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om • Enter a ? at the prompt or after a keyword. There must always be a space

    before the ?.• To obtain a list of keywords with a brief functional description, do the following:

    • Enter help at the prompt.• To obtain a list of available options, do the following:

    • Type a keyword followed by a space and a ? • Type a partial keyword followed by a ?

    • A display of keywords beginning with the partial keyword is listed.

    The following text illustrates the results of entering ip ? at the prompt.

    FTOS(conf)#ip ?access-list Named access-list as-path BGP autonomous system path filter community-list Add a community list entry domain-list Domain name to complete unqualified host namedomain-lookup Enable IP Domain Name System hostname translationdomain-name Define the default domain name fib FIB configuration commands ftp FTP configuration commands host Add an entry to the ip hostname table max-frag-count Max. fragmented packets allowed in IP re-assemblymulticast-routing Enable IP multicast forwarding name-server Specify address of name server to use pim Protocol Independent Multicast prefix-list Build a prefix list radius Interface configuration for RADIUS redirect-list Named redirect-list route Establish static routes scp SCP configuration commands source-route Process packets with source routing header optionsssh SSH configuration commands tacacs Interface configuration for TACACS+ telnet Specify telnet options tftp TFTP configuration commands trace-group Named trace-list trace-list Named trace-list FTOS(conf)#ip

    When entering commands, you can take advantage of the following timesaving features:

    • The commands are not case sensitive.• You can enter partial (truncated) command keywords. For example, you can enter

    int gig int interface for the interface gigabitethernet interface command.

    • Use the TAB key to complete keywords in commands. • Use the up arrow key to display the last enabled command.• Use either the Backspace key or the Delete key to erase the previous character.

  • CLI Basics | 21

    Use the left and right arrow keys to navigate left or right in the FTOS command line. Table 2-2 defines the key combinations valid at the FTOS command line.

    Using the Keyword NoTo disable, delete, or return to default values, use the no form of the commands. For most commands, if you type the keyword no in front of the command, you will disable that command or delete it from the running configuration. In this document, the no form of the command is discussed in the Command Syntax portion of the command description.

    Filtering show CommandsYou can filter the display output of a show command to find specific information, to display certain information only, or to begin the command output at the first instance of a regular expression or phrase.

    Table 2-2. Short-cut Keys and their Actions

    Key Combination Action

    CNTL-A Moves the cursor to the beginning of the command line.

    CNTL-B Moves the cursor back one character.

    CNTL-D Deletes character at cursor.

    CNTL-E Moves the cursor to the end of the line.

    CNTL-F Moves the cursor forward one character.

    CNTL-I Completes a keyword.

    CNTL-K Deletes all characters from the cursor to the end of the command line.

    CNTL-L Re-enters the previous command.

    CNTL-N Return to more recent commands in the history buffer after recalling commands with Ctrl-P or the up arrow key

    CNTL-P Recalls commands, beginning with the last command

    CNTL-R Re-enters the previous command.

    CNTL-U Deletes the line.

    CNTL-W Deletes the previous word.

    CNTL-X Deletes the line.

    CNTL-Z Ends continuous scrolling of command outputs.

    Esc B Moves the cursor back one word.

    Esc F Moves the cursor forward one word.

    Esc D Deletes all characters from the cursor to the end of the word.

  • 22 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om When you execute a show command, followed by a pipe ( | ) and one of the

    parameters listed below and a regular expression, the resulting output either excludes or includes those parameters, as defined by the parameter:

    • display — display additional configuration information• except— display only text that does not match the pattern (or regular expression)• find — search for the first occurrence of a pattern • grep — display text that matches a pattern• no-more — do not paginate the display output • save — copy output to a file for future use

    The grep command option has an ignore-case sub-option that makes the search case-insensitive. For example, the commands:

    • show run | grep Ethernet would return a search result with instances containing a capitalized “Ethernet,” such as interface GigabitEthernet 0/0.

    • show run | grep ethernet would not return the search result, above, because it only searches for instances containing a non-capitalized “ethernet.”

    Executing the command show run | grep Ethernet ignore-case would return instances containing both “Ethernet” and “ethernet.”

    Displaying All Output

    To display the output all at once (not one screen at a time), use the no-more after the pipe. This is similar to the terminal length screen-length command except that the no-more option affects the output of just the specified command.For example:

    FTOS#show running-config|no-more

    Filtering Command Output Multiple Times

    You can filter a single command output multiple times. Place the save option as the last filter. For example:

    FTOS# command | grep regular-expression | except regular-expression | grep other-regular-expression | find regular-expression | no-more | save

    Note: FTOS accepts a space before or after the pipe, no space before or after the pipe, or any combination. For example:

    FTOS#command | grep gigabit |except regular-expression | find regular-expression

  • CLI Basics | 23

    Command ModesTo navigate to various CLI modes, you need to use specific commands to launch each mode. Navigation to these modes is discussed in the following sections.

    EXEC Mode

    When you initially log in to the switch, by default, you are logged into the EXEC mode. This mode allows you to view settings and to enter the EXEC Privilege mode to configure the device. While you are in the EXEC mode, the > prompt is displayed following the “hostname” prompt, as described above, which is “FTOS” by default. You can change it with the hostname command. Refer to the command hostname. Each mode prompt is preceded by the hostname.

    EXEC Privilege Mode

    The enable command accesses the EXEC Privilege mode. If an administrator has configured an “Enable” password, you will be prompted to enter it here.

    The EXEC Privilege mode allows you to access all commands accessible in EXEC mode, plus other commands, such as to clear ARP entries and IP addresses. In addition, you can access the CONFIGURATION mode to configure interfaces, routes, and protocols on the switch. While you are logged in to the EXEC Privilege mode, the # prompt is displayed.

    CONFIGURATION Mode

    In the EXEC Privilege mode, use the configure command to enter the CONFIGURATION mode and configure routing protocols and access interfaces.

    To enter the CONFIGURATION mode:

    1. Verify that you are logged in to the EXEC Privilege mode.2. Enter the configure command. The prompt changes to include (conf).

    From this mode, you can enter INTERFACE by using the interface command.

    INTERFACE Mode

    Use the INTERFACE mode to configure interfaces or IP services on those interfaces. An interface can be physical (for example, a Gigabit Ethernet port) or virtual (for example, the Null interface).

    Note: Some of the following modes are not available on C-Series or S-Series.

  • 24 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om To enter INTERFACE mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the interface command followed by an interface type and interface number that is

    available on the switch. 3. The prompt changes to include the designated interface and slot/port number, as outlined

    in Table 2-3.

    LINE Mode

    Use the LINE mode to configure console or virtual terminal parameters.

    To enter LINE mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the line command. You must include the keywords console or vty and their line num-

    ber available on the switch.The prompt changes to include (config-line-console) or (con-fig-line-vty).

    You can exit this mode by using the exit command.

    TRACE-LIST Mode

    When in the CONFIGURATION mode, use the trace-list command to enter the TRACE-LIST mode and configure a Trace list.

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the ip trace-list command. You must include the name of the Trace list. The prompt

    change to include (conf-trace-acl).

    Table 2-3. Interface prompts

    Prompt Interface Type

    FTOS(conf-if)# INTERFACE mode

    FTOS(conf-if-gi-0/0)# Gigabit Ethernet interface followed by slot/port information

    FTOS(conf-if-te-0/0)# Ten Gigabit Ethernet interface followed by slot/port information

    FTOS(conf-if-fo-0/0)# Forty Gigabit Ethernet interface followed by slot/port information

    FTOS(conf-if-lo-0)# Loopback interface number.

    FTOS(conf-if-nu-0)# Null Interface followed by zero

    FTOS(conf-if-po-0)# Port-channel interface number

    FTOS(conf-if-vl-0)# VLAN Interface followed by VLAN number (range 1 to 4094)

    FTOS(conf-if-so-0/0)# SONET interface followed by slot/port information.

    FTOS(conf-if-ma-0/0)# Management Ethernet interface followed by slot/port information

    FTOS(conf-if-range)# Designated interface range (used for bulk configuration; refer to interface range).

  • CLI Basics | 25

    You can exit this mode by using the exit command.

    MAC ACCESS LIST Mode

    While in the CONFIGURATION mode, use the mac access-list standard or mac access-list extended command to enter the MAC ACCESS LIST mode and configure either standard or extended access control lists (ACL).

    To enter MAC ACCESS LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Use the mac access-list standard or mac access-list extended command. You must include

    a name for the ACL.The prompt changes to include (conf-std-macl) or (conf-ext-macl).

    You can return to the CONFIGURATION mode by entering the exit command.

    IP ACCESS LIST Mode

    While in the CONFIGURATION mode, use the ip access-list standard or ip access-list extended command to enter the IP ACCESS LIST mode and configure either standard or extended access control lists (ACL).

    To enter IP ACCESS LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Use the ip access-list standard or ip access-list extended command. You must include a

    name for the ACL.The prompt changes to include (conf-std-nacl) or (conf-ext-nacl).

    You can return to the CONFIGURATION mode by entering the exit command.

    ROUTE-MAP Mode

    While in the CONFIGURATION mode, use the route-map command to enter the ROUTE-MAP mode and configure a route map.

    To enter ROUTE-MAP mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Use the route-map map-name [permit | deny] [sequence-number] command. The prompt

    changes to include (route-map).

    You can return to the CONFIGURATION mode by entering the exit command.

  • 26 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om PREFIX-LIST Mode

    While in the CONFIGURATION mode, use the ip prefix-list command to enter the PREFIX-LIST mode and configure a prefix list.

    To enter PREFIX-LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the ip prefix-list command. You must include a name for the prefix list.The prompt

    changes to include (conf-nprefixl).

    You can return to the CONFIGURATION mode by entering the exit command.

    AS-PATH ACL Mode

    Use the AS-PATH ACL mode to configure an AS-PATH Access Control List (ACL) on the E-Series. Refer to Chapter 7, Access Control Lists (ACL).

    To enter AS-PATH ACL mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the ip as-path access-list command. You must include a name for the AS-PATH

    ACL.The prompt changes to include (config-as-path).

    You can return to the CONFIGURATION mode by entering the exit command.

    IP COMMUNITY LIST Mode

    Use the IP COMMUNITY LIST mode to configure an IP Community ACL on the E-Series. Refer to Chapter 7, Access Control Lists (ACL).

    To enter IP COMMUNITY LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the ip community-list command. You must include a name for the Community

    list.The prompt changes to include (config-community-list).

    You can return to the CONFIGURATION mode by entering the exit command.

    REDIRECT-LIST Mode

    Use the REDIRECT-LIST mode to configure a Redirect list on the E-Series, as described in the E-Series FTOS Command Line Reference Guide Chapter 39, Policy-based Routing (PBR).

    To enter REDIRECT-LIST mode:

  • CLI Basics | 27

    1. Verify that you are logged in to the CONFIGURATION mode.2. Use the ip redirect-list command. You must include a name for the Redirect-list.The

    prompt changes to include (conf-redirect-list).

    You can return to the CONFIGURATION mode by entering the exit command.

    SPANNING TREE Mode

    Use the STP mode to enable and configure the Spanning Tree protocol, as described in Chapter 52, Spanning Tree Protocol (STP).

    To enter STP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol spanning-tree stp-id command.

    You can return to the CONFIGURATION mode by entering the exit command.

    Per-VLAN SPANNING TREE Plus Mode

    Use PVST+ mode to enable and configure the Per-VLAN Spanning Tree (PVST+) protocol, as described in Chapter 41, Per-VLAN Spanning Tree Plus (PVST+).

    To enter PVST+ mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol spanning-tree pvst command.

    You can return to the CONFIGURATION mode by entering the exit command.

    RAPID SPANNING TREE Mode

    Use PVST+ mode to enable and configure the RSTP protocol, as described in Chapter 45, Rapid Spanning Tree Protocol (RSTP).

    To enter RSTP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol spanning-tree rstp command.

    You can return to the CONFIGURATION mode by entering the exit command.

    Note: The protocol is PVST+, but the plus sign is dropped at the CLI prompt

  • 28 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om MULTIPLE SPANNING TREE Mode

    Use MULTIPLE SPANNING TREE mode to enable and configure the Multiple Spanning Tree protocol, as described in Chapter 33, Multiple Spanning Tree Protocol (MSTP).

    To enter MULTIPLE SPANNING TREE mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol spanning-tree mstp command.

    You can return to the CONFIGURATION mode by entering the exit command.

    PROTOCOL GVRP Mode

    Use the PROTOCOL GVRP mode to enable and configure GARP VLAN Registration Protocol (GVRP), as described in Chapter 18, GARP VLAN Registration (GVRP).

    To enter PROTOCOL GVRP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol gvrp command syntax.

    You can return to the CONFIGURATION mode by entering the exit command.

    ROUTER OSPF Mode

    Use the ROUTER OSPF mode to configure OSPF, as described in Chapter 37, Open Shortest Path First (OSPFv2).

    To enter ROUTER OSPF mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Use the router ospf {process-id} command.The prompt changes to include

    (conf-router_ospf-id).

    You can switch to the INTERFACE mode by using the interface command or you can switch to the ROUTER RIP mode by using the router rip command.

    ROUTER RIP Mode

    Use the ROUTER RIP mode to configure RIP on the C-Series or E-Series, as described in Chapter 43, Routing Information Protocol (RIP).

    To enter ROUTER RIP mode:

  • CLI Basics | 29

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the router rip command.The prompt changes to include (conf-router_rip).

    You can switch to the INTERFACE mode by using the interface command or you can switch to the ROUTER OSPF mode by using the router ospf command.

    ROUTER ISIS Mode

    Use the ROUTER ISIS mode to configure ISIS on the E-Series, as described in the E-Series E-Series FTOS Command Line Reference Guide chapter Intermediate System to Intermediate System (IS-IS).

    To enter ROUTER ISIS mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the router isis [tag] command.The prompt changes to include (conf-router_isis).

    You can switch to the INTERFACE mode by using the interface command or you can switch to the ROUTER RIP mode by using the router rip command.

    ROUTER BGP Mode

    Use the ROUTER BGP mode to configure BGP on the C-Series or E-Series, as described in Chapter 9, Border Gateway Protocol IPv4 (BGPv4).

    To enter ROUTER BGP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the router bgp as-number command.The prompt changes to include

    (conf-router_bgp).

    You can return to the CONFIGURATION mode by entering the exit command.

    VLT DOMAIN Mode

    Use VLT DOMAIN mode to enable and configure the VLT domain protocol, as described in Chapter 57, Virtual Link Trunking (VLT).

    To enter VLT DOMAIN mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the config-vlt-domain command.

    You can return to the CONFIGURATION mode by entering the exit command.

  • 30 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Determining the Chassis Mode

    The chassis mode in FTOS determines which hardware is being supported in an E-Series chassis. The chassis mode is programmed into an EEPROM on the backplane of the chassis and the change takes place only after the chassis is rebooted. Configuring the appropriate chassis mode enables the system to use all the ports on the card and recognize all software features.

  • File Management | 31

    3File Management

    OverviewThis chapter contains commands needed to manage the configuration files and includes other file management commands found in FTOS. The commands in this chapter are supported by FTOS on Dell Force10 platforms, as indicated by the characters that appear under each of the command headings: e E-Series, c C-Series, s S-Series, S4810.

    This chapter contains these sections:

    • Basic File Management Commands• Upgrading the C-Series FPGA

    Basic File Management CommandsThe commands included in this chapter are:

    • boot config• boot host• boot network• boot system• boot system gateway• cd• change bootflash-image• copy• copy (Streamline Upgrade)• copy running-config startup-config• delete• dir• download alt-boot-image• download alt-full-image• download alt-system-image• format (C-Series and E-Series)

  • 32 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om • format flash (S-Series)

    • format flash (Z9000)• logging coredump• logging coredump server• pwd• rename• boot system• show bootvar• show file• show file-systems• show linecard • show os-version• show running-config• show startup-config• show version• upgrade (E-Series version)• upgrade (C-Series version)• upgrade (S-Series management unit and Z9000) • upgrade fpga-image

    boot configce Set the location and name of the configuration file that is loaded at system start-up (or

    reload) instead of the default startup-configuration.

    Syntax boot config {remote-first | rpm0 file-url | rpm1 file-url}

    Parameters

    Defaults Not configured.

    Command Modes CONFIGURATION

    CommandHistory

    remote-first Enter the keywords remote-first to attempt to load the boot configuration files from a remote location.

    rpm0 Enter the keywords rpm0 first to specify the local boot configuration file for RPM 0.rpm1 Enter the keywords rpm1 first to specify the local boot configuration file for RPM 1.file-url Enter the location information:

    • For a file on the internal Flash, enter flash:// followed by the filename.• For a file on the external Flash, enter slot0:// followed by the filename.

    Version 7.5.1.0 Introduced on C-SeriesE-Series original Command

  • File Management | 33

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (copy running-config startup-config or write)......

    Dell Force10 strongly recommends using local files for configuration (RPM0 or RPM1 flash or slot0).

    When you specify a file as the boot config file, it is listed in the boot variables (bootvar) as LOCAL CONFIG FILE. If you do not specify a boot config file, then the startup-configuration is used, although the bootvar shows LOCAL CONFIG FILE = variable does not exist. When you specify a boot config file, the switch reloads with that config file, rather than the startup-config. Note that if you specify a local config file which is not present in the specified location, then the startup-configuration is loaded.

    The write memory command always saves the running-configuration to the file labeled startup-configuration. When using a LOCAL CONFIG FILE other than the startup-config, use the copy command to save any running-configuration changes to that local file.

    The following text is an example of output for show bootvar with no boot configuration:

    FTOS#show bootvarPRIMARY IMAGE FILE = flash://FTOS-EF-8.2.1.0.binSECONDARY IMAGE FILE = flash://FTOS-EF-7.6.1.0.binDEFAULT IMAGE FILE = flash://FTOS-EF-7.5.1.0.binLOCAL CONFIG FILE = variable does not existPRIMARY HOST CONFIG FILE = variable does not existSECONDARY HOST CONFIG FILE = variable does not existPRIMARY NETWORK CONFIG FILE = variable does not existSECONDARY NETWORK CONFIG FILE = variable does not existCURRENT IMAGE FILE = flash://FTOS-EF-8.2.1.0.binCURRENT CONFIG FILE 1 = flash://startup-configCURRENT CONFIG FILE 2 = variable does not existCONFIG LOAD PREFERENCE = local firstBOOT INTERFACE GATEWAY IP ADDRESS = variable does not exist

    The following text is an example of output for show bootvar with a boot configuration:

    FTOS#show bootvarPRIMARY IMAGE FILE = flash://FTOS-EF-8.2.1.0.binSECONDARY IMAGE FILE = flash://FTOS-EF-7.6.1.0.binDEFAULT IMAGE FILE = flash://FTOS-EF-7.5.1.0.binLOCAL CONFIG FILE = variable does not existPRIMARY HOST CONFIG FILE = variable does not existSECONDARY HOST CONFIG FILE = variable does not existPRIMARY NETWORK CONFIG FILE = variable does not existSECONDARY NETWORK CONFIG FILE = variable does not existCURRENT IMAGE FILE = flash://FTOS-EF-8.2.1.0.binCURRENT CONFIG FILE 1 = flash://CustomerA.cfgCURRENT CONFIG FILE 2 = variable does not existCONFIG LOAD PREFERENCE = local firstBOOT INTERFACE GATEWAY IP ADDRESS = variable does not exist

  • 34 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Related

    Commands

    boot hostc e Set the location of the configuration file from a remote host.

    Syntax boot host {primary | secondary} remote-url

    Parameters

    Defaults Not configured.

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (using the copy command).

    RelatedCommands

    boot networkc e Set the location of the configuration file in a remote network.

    Syntax boot network {primary | secondary} remote-url

    Parameters

    Defaults None

    show bootvar Display the variable settings for the E-Series boot parameters.

    primary Enter the keywords primary to attempt to load the primary host configuration files.

    secondary Enter the keywords secondary to attempt to load the secondary host configuration files.

    remote-url Enter the following location keywords and information:• For a file on an FTP server, enter ftp://user:password@hostip/filepath• For a file on a TFTP server, enter tftp://hostip/filepath

    Version 7.5.1.0 Introduced on C-SeriesE-Series original Command

    show bootvar Display the variable settings for the E-Series boot parameters.

    primary Enter the keywords primary to attempt to load the primary network configuration files.

    secondary Enter the keywords secondary to attempt to load the secondary network configuration files.

    remote-url Enter the following location keywords and information:• For a file on an FTP server, enter ftp://user:password@hostip/filepath• For a file on a TFTP server, enter tftp://hostip/filepath

  • File Management | 35

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (using the copy command).

    RelatedCommands

    boot systemc e Tell the system where to access the FTOS image used to boot the system.

    Syntax boot system {rpm0 | rpm1} (default | primary | secondary} file-url

    Parameters

    Defaults Not configured.

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (using the copy command) and reload system.

    Version 7.5.1.0 Introduced on C-SeriesE-Series original Command

    show bootvar Display the variable settings for the E-Series boot parameters.

    rpm0 Enter the keyword rpm0 to configure boot parameters for RPM0.rpm1 Enter the keyword rpm1 to configure boot parameters for RPM1.default After entering rpm0 or rpm1, enter the keyword default to specify the parameters

    to be used if those specified by primary or secondary fail. The default location should always be the internal flash device (flash:), so that you can be sure that a verified image is available there.

    primary After entering rpm0 or rpm1, enter the keyword primary to configure the boot parameters used in the first attempt to boot FTOS.

    secondary After entering rpm0 or rpm1, enter the keyword secondary to configure boot parameters used if the primary operating system boot selection is not available.

    file-url To boot from a file:• on the internal Flash, enter flash:// followed by the filename.• on an FTP server, enter ftp://user:password@hostip/filepath• on the external Flash, enter slot0:// followed by the filename.• on a TFTP server, enter tftp://hostip/filepath

    Version 7.5.1.0 Introduced on C-SeriesE-Series original Command

  • 36 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Related

    Commands

    boot system gatewayc e Specify the IP address of the default next-hop gateway for the management subnet.

    Syntax boot system gateway ip-address

    Parameters

    Command Modes CONFIGURATION

    UsageInformation

    Saving the address to the startup configuration file preserves the address in NVRAM in case the startup configuration file is deleted.

    CommandHistory

    RelatedCommands

    cd c e s Change to a different working directory.

    Syntax cd directory

    Parameters

    Command Modes EXEC Privilege

    CommandHistory

    change bootflash-imagec e Change boot flash image from which to boot.

    Syntax change bootflash-image {cp | linecard linecard-slot | rp}

    change bootflash-image Change the primary, secondary, or default boot image configuration.boot system gateway Specify the IP address of the default next-hop gateway for the

    management subnet.

    ip-address Enter an IP address in dotted decimal format.

    Version 7.5.1.0 Introduced on C-SeriesE-Series original Command

    change bootflash-image Change the primary, secondary, or default boot image configuration.

    directory (OPTONAL) Enter one of the following:• flash: (internal Flash) or any sub-directory• slot0: (external Flash) or any sub-directory (C-Series and E-Series only)

    Version 7.6.1.0 Introduced on S-SeriesVersion 7.5.1.0 Introduced on C-SeriesE-Series original Command

  • File Management | 37

    Parameters

    Defaults Not configured.

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    A system message appears stating that the bootflash image has been changed. You must reload the system before the system can switch to the new bootflash image.

    copyc e s Copy one file to another location. FTOS supports IPv4 and IPv6 addressing for FTP,

    TFTP, and SCP (in the hostip field).

    Syntax copy source-file-url destination-file-url

    Parameters

    Command Modes EXEC Privilege

    cp Enter the keyword cp to change the bootflash image on the Control Processor on the RPM.

    linecard linecard-slot Enter the keyword linecard followed by the slot number to change the bootflash image on a specific line card.C-Series Range: 0-7 E-Series Range: 0 to 13 on the E1200; 0 on 6 on the E600, and 0 to 5 on the E300.

    rp Enter the keyword rp to change the bootflash image on the RPM Route Processor.

    Version 7.5.1.0 Introduced on C-SeriesE-Series original Command

    file-url Enter the following location keywords and information:• To copy a file from the internal FLASH, enter flash:// followed by the filename.• To copy a file on an FTP server, enter ftp://user:password@hostip/filepath• To copy a file from the internal FLASH on RPM0, enter rpm0flash://filepath• To copy a file from the external FLASH on RPM0, enter rpm0slot0://filepath• To copy a file from the internal FLASH on RPM1, enter rpm1flash://filepath• To copy a file from the external FLASH on RPM1, enter rpm1slot0://filepath• To copy the running configuration, enter the keyword running-config.• To copy the startup configuration, enter the keyword startup-config.• To copy using Secure Copy (SCP), enter the keyword scp: (If scp: is entered in

    the source position, then enter the target URL; If scp: is entered in the target position, first enter the source URL; refer to the examples below.)

    • To copy a file on the external FLASH, enter slot0:// followed by the filename.• To copy a file on a TFTP server, enter tftp://hostip/filepathExaScale only• To copy a file from a USB drive on RPM0, enter rpm0usbflash://filepath• To copy a file from an external USB drive, enter usbflash://filepath

  • 38 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Command

    History

    UsageInformation

    FTOS supports a maximum of 100 files, at the root directory level, on both the internal and external Flash.

    The usbflash and rpm0usbflash commands are supported on E-Series ExaScale platform only. Refer to the FTOS Release Notes for a list of approved USB vendors.

    When copying a file to a remote location (for example, using Secure Copy (SCP)), enter only the keywords and FTOS prompts you for the rest of the information.

    For example, when using SCP, you can enter copy running-config scp: The running-config is the source, and the target is specified in the ensuing prompts. FTOS prompts you to enter any required information, as needed for the named destination—remote destination, destination filename, user ID and password, etc.

    When you use the copy running-config startup-config command to copy the running configuration (the startup configuration file amended by any configuration changes made since the system was started) to the startup configuration file, FTOS creates a backup file on the internal flash of the startup configuration.

    FTOS supports copying the running-configuration to a TFTP server or to an FTP server:

    copy running-config tftp:

    copy running-config ftp:

    The following text is an example of the output when the running-configuration is copied:

    FTOS#copy running-config scp:/Address or name of remote host []: 10.10.10.1Destination file name [startup-config]? old_runningUser name to login remote host? ******Password to login remote host? ******

    In this example — copy scp: flash: — specifying SCP in the first position indicates that the target is to be specified in the ensuing prompts. Entering flash: in the second position means that the target is the internal Flash. In the following example, the source is on a secure server running SSH, so the user is prompted for the UDP port of the SSH server on the remote host.

    FTOS#copy scp: flash:Address or name of remote host []: 10.11.199.134Port number of the server [22]: 99

    Version 8.4.1.0 Added IPv6 addressing support for FTP, TFTP, and SCP.Version 8.2.1.0 Added usbflash and rpm0usbflash commands on E-Series ExaScaleVersion 7.6.1.0 Introduced on S-Series and added SSH port number to SCP prompt sequence

    on all systems.Version 7.5.1.0 Introduced on C-SeriesE-Series original Command

  • File Management | 39

    Source file name []: test.cfgUser name to login remote host: adminPassword to login remote host: Destination file name [test.cfg]: test1.cfg

    RelatedCommands

    copy (Streamline Upgrade)c e Copy a system image to a local file and update the boot profile.

    Syntax copy source-url target-url [boot-image [synchronize-rpm [external]]]

    Parameters

    Defaults No default behavior

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    In this streamline copy command, the source image is copied to the primary RPM and then, if specified, to the standby RPM. After the copy is complete, the new image file path on each RPM is automatically configured as the primary image path for the next boot. The current system image (the one from which the RPM booted) is automatically configured as the secondary image path.

    FTOS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP.

    cd Change working directory.

    source-url Enter the source file in url format. The source file is a valid Dell Force10 release image. Image validation is automatic.

    target-url Enter the local target file in url format.boot-image Enter the keyword boot-image to designate this copy command as a

    streamline update.synchronize-rpm Enter the keyword synchronize-rpm to copy the new image file to the peer

    RPM. external Enter the keyword external to designate the target device on the peer RPM

    as external flash (instead of the default internal flash).Default: Internal Flash

    Version 8.4.1.0 Added IPv6 addressing support for FTP, TFTP, and SCP.Version 7.5.1.0 Introduced on C-SeriesVersion 6.1.1.0 Introduced

    Note: The keywords boot-image, synchronize-rpm, and external can be used on the Primary RPM only.

  • 40 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om copy running-config startup-config

    c e Copy running configuration to the startup configuration.

    Syntax copy running-config startup-config {duplicate}

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    This command is useful for quickly making a changed configuration on one chassis available on external flash in order to move it to another chassis.

    When you use the copy running-config startup-config duplicate command to copy the running configuration to the startup configuration, FTOS creates a backup file on the internal flash of the startup configuration.

    deletec e s Delete a file from the flash. Once deleted, files cannot be restored.

    Syntax delete flash-url [no-confirm]

    Parameters

    Command Modes EXEC Privilege

    CommandHistory

    dirc e s Display the files in a file system. The default is the current directory.

    Syntax dir [filename | directory name:]

    Version 7.5.1.0 Introduced on C-SeriesVersion 6.3.1.0 Introduced

    flash-url Enter the following location and keywords:• For a file or directory on the internal Flash, enter flash:// followed by the

    filename or directory name.• For a file or directory on the external Flash, enter slot0:// followed by the

    filename or directory name.no-confirm (OPTIONAL) Enter the keyword no-confirm to specify that FTOS does not

    require user input for each file prior to deletion.

    Version 7.6.1.0 Introduced on S-SeriesVersion 7.5.1.0 Introduced on C-SeriesE-Series original Command

  • File Management | 41

    Parameters

    Command Modes EXEC Privilege

    CommandHistory

    Example FTOS#dir Directory of flash:

    1 -rwx 6478482 May 13 101 16:54:34 E1200.BIN

    flash: 64077824 bytes total (57454592 bytes free)FTOS#

    RelatedCommands

    download alt-boot-imagec e Download an alternate boot image to the chassis.

    Syntax download alt-boot-image file-url

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade command.

    For software upgrade details, refer to the FTOS Release Notes.

    RelatedCommands

    download alt-full-imagee Download an alternate FTOS image to the chassis.

    filename | directory name: (OPTIONAL) Enter one of the following:• For a file or directory on the internal Flash, enter flash://

    followed by the filename or directory name.• For a file or directory on the external Flash, enter slot0://

    followed by the filename or directory name:

    Version 7.6.1.0 Introduced on S-SeriesVersion 7.5.1.0 Introduced on C-SeriesE-Series original Command

    cd Change working directory.

    Version 7.7.1.0 Removed from E-Series and C-SeriesVersion 7.5.1.0 Introduced on C-SeriesE-Series original Command

    upgrade (E-Series version) Upgrade the bootflash or boot selector versions.upgrade (C-Series version) Upgrade the bootflash or boot selector versions.

  • 42 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Syntax download alt-full-image file-url

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade command.

    For software upgrade details, refer to the FTOS Release Notes.

    RelatedCommands

    download alt-system-imagee Download an alternate system image (not the boot flash or boot selector image) to the

    chassis.

    Syntax download alt-system-image file-url

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade command.

    For software upgrade details, refer to the FTOS Release Notes.

    RelatedCommands

    format (C-Series and E-Series)ce Erase all existing files and reformat a file system. Once the file system is formatted,

    files cannot be restored.

    Syntax format filesystem: [dosFs1.0 | dosFs2.0]

    Parameters

    Version 7.7.1.0 Removed form E-SeriesVersion 6.5.1.0 Introduced

    upgrade (E-Series version) Upgrade the bootflash or boot selector versions

    Version 7.7.1.0 Removed from E-SeriesVersion 6.5.1.0 Introduced

    upgrade (E-Series version) Upgrade the bootflash or boot selector versions

    filesystem: Enter one of the following:• To reformat the internal Flash, enter flash:• To reformat the external Flash, enter slot0:

    dosFs1.0 Enter the keyword dosFs1.0 to format in DOS 1.0 (the default)dosFs2.0 Enter the keyword dosFs2.0 to format in DOS 2.0

  • File Management | 43

    Default DOS 1.0 (dosFs1.0)

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    When you format flash:

    1. The startup-config is erased.

    2. All cacheboot data files are erased and you must reconfigure cacheboot to regain it.

    3. All generated SSH keys are erased and you must recreate them.

    4. All archived configuration files are erased.

    5. All trace logs, crash logs, core dumps, and call-home logs are erased.

    6. In-service Process patches are erased.

    After reformatting is complete, three empty directories are automatically created on flash: CRASH_LOG_DIR, TRACE_LOG_DIR and NVTRACE_LOG_DIR.

    Note: Version option is available on LC-ED-RPM only. LC-EE3-RPM, LC-EF-RPM, and LC-EF3-RPM supports DOS 2.0 only.

    RelatedCommands

    format flash (S-Series)s Erase all existing files and reformat the filesystem in the internal flash memory. Once

    the filesystem is formatted, files cannot be restored.

    Syntax format flash:

    Default flash memory

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    You must include the colon (:) when entering this command.

    Caution: This command deletes all files, including the startup configuration file. After executing this command, consider saving the running config as the startup config (use the write memory command or copy run start).

    Version 7.5.1.0 Introduced on C-SeriesE-Series original Command

    show file Display contents of a text file in the local filesystem. show file-systems Display information about the file systems on the system.

    Version 7.8.1.0 Introduced on S-Series

  • 44 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Related

    Commands

    format flash (Z9000) z Erase all existing files and reformat the file system in the internal flash memory or

    the USB drive. Once the file system is formatted, files cannot be restored.

    Syntax format [flash: | slot0: | usbflash: ]

    Parameters

    Default flash memory

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    You must include the colon (:) when entering this command.

    Caution: This command deletes all files, including the startup configuration file. So, after executing this command, consider saving the running config as the startup config (use the write memory command or copy run start).

    logging coredumpc e s

    zEnable coredump.

    Syntax logging coredump {cp | linecard {number | all} | rps}

    Parameters

    Defaults The kernel coredump is enabled by default for RP 1 and 2 on E-Series. The kernel coredump for CP and application coredump are disabled on all systems by default.

    Command Modes CONFIGURATION

    copy Copy the current configuration to either the startup-configuration file or the terminal.

    show file Display contents of a text file in the local filesystem. show file-systems Display information about the file systems on the system.

    flash: | slot0: | usbflash:

    flash: Reformat the file system in the internal flash memory.slot0: Reformat the file system in the external flash memory, i.e., SSD. usbflash: Reformat the file system in the usbflash.

    Version 8.3.11.1 Introduced on the Z9000

    cp Enable coredump for the CP.linecard Enable coredump for a linecard.rps Enable coredump for RP 1 and 2.

  • File Management | 45

    CommandHistory

    UsageInformati