11
Ericsson Internal STANDARD MODULE OVERVIEW 1 (11) Prepared (also subject responsible if other) No. EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F Standard Module Overview Passive In-building Antenna System Products

S M O - Passive in-building Antenna System Products

Embed Size (px)

DESCRIPTION

S M O - Passive in-building Antenna System Products

Citation preview

  • Ericsson Internal STANDARD MODULE OVERVIEW 1 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    Standard Module Overview

    Passive In-building Antenna System Products

  • Ericsson Internal STANDARD MODULE OVERVIEW 2 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    Contents 1 Revision history ...................................................................................3 2 Introduction..........................................................................................3 3 Reading and using this document .......................................................3 4 Preferred products...............................................................................4 4.1 In-building antennas ............................................................................4 4.2 Antenna near products ........................................................................4 4.3 Fire retardant feeder cables ................................................................5 4.4 Connectors ..........................................................................................6 4.5 1/4" jumper cables...............................................................................7 4.6 Adapters ..............................................................................................7 5 Other products.....................................................................................8 5.1 In-building antennas ............................................................................8 5.2 Antenna near products ........................................................................8 5.3 Radiating cables..................................................................................9 6 Phase out products ...........................................................................10 6.1 In-building antennas ..........................................................................10 6.2 Antenna near products ......................................................................10 6.3 Fire retardant feeder cables ..............................................................10 6.4 Connectors ........................................................................................11 6.5 Antenna near products ......................................................................11 7 Terminology and abbreviations .........................................................11

  • Ericsson Internal STANDARD MODULE OVERVIEW 3 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    1 Revision history Rev. Date Description

    C 2004-04-29 New products: KRF 201 306/2, KRF 201 329/2, FAB 102 1044/04, /05 and /06.Cancelled products: KRF 201 306/1 and KRF 201 329/1.

    D 2004-08-25 New products: KRE 101 2000/1 and 2001/1.

    E 2006-04-20 New product: KRF 102 186/1. Cancelled product: KRE 101 1924/1. Classification changed to Preferred products: KRE 101 1910/1. Classification changed to Other products: KRE 101 1861/1.

    F 2007-04-17 Product updates: KRE 101 2001/1 frequency range updated. New products: ZHC 901 19/1, /2, and /3, ZHC 901 21/1, /2, /3 , /4 and /5 UML 901 08/1, ZHC 901 22/1, FAB 102 1943/1 and /2, FAB 102 989/1, FAB 102 1944/1, RPT 899 024/1, RNT 899 065/1, RPT 899 95/1, RNT 899 066/1, RPT 899 97/1, RPT 987 25/1, RNT 899 067/1 and RPT 899 89/1 Phase out products: KRE 101 1861/1, KRF 102 246/2, /3 and /4, KRF 102 247/1, /2 and /3, ZYA 402 04/1, FAB 102 1044/06, FAB 102 1044/03, RPT 403 178/01, RPT 403 177/01, KRF 111 53/1

    2 Introduction

    This document is a standard module overview for the following passive in-building antenna system products:

    In-building antennas Antenna near products Fire retardant feeder cables Connectors 1/4" jumper cables Adapters Radiating cables

    3 Reading and using this document

    Always make sure that you have the latest revision of this document, since the contents may change without notice.

    Preferred in-building antenna system products described in chapter 4 shall always be the first choice. Other in-building antenna system products described in chapter 5 shall only be used if there are no suitable options among the preferred products. Products described in chapter 6 are being phased out.

  • Ericsson Internal STANDARD MODULE OVERVIEW 4 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    4 Preferred products

    4.1 In-building antennas

    Ericsson P/N Supplier P/N Height[mm]

    f [MHz]

    HBW []

    Gain [dBi]

    Connector Links

    KRE 101 2000/1 Kathrein 800 10248

    231 806-960+1710-2500

    90 7 N(f) incl. 1m jumper cable

    1301-spec

    KRE 101 2001/1 Kathrein 800 10249

    94 806-960+1425-3800+5150-6000

    Omni 2 N(f) 1301-spec

    KRE 101 1971/1 Kathrein 800 10137

    78 876-960+1710-2500

    Omni 2 N(f) 1301-spec

    KRE 101 1910/1 Kathrein 800 10173

    85 876-960+1710-2500

    Omni 2 N(f) 1301-spec

    4.2 Antenna near products

    Ericsson P/N Supplier P/N Description f [MHz]

    Connector Links

    KRF 102 168/1 - WLAN injector 806-2170+ 2400-2483

    N(f) Brochure

    KRY 101 1841/1 - Multicasting Matrix 806-960 N(f) Brochure

    KRY 101 1841/2 - Multicasting Matrix 1710-2200 N(f) Brochure

    KRF 201 329/2 - Combining box 806-960+ 1710-1880+ 1920-2170

    N(f) Brochure

    KRF 201 306/2 - Combining box

    806-960+ 1710-2170

    N(f) Brochure

    ZHC 901 19/1 - 2-way Power Splitter 800-2700 N(f) Brochure

    ZHC 901 19/2 - 3-way Power Splitter 800-2700 N(f) Brochure

    ZHC 901 19/3 - 4-way Power Splitter 800-2700 N(f) Brochure

    ZHC 901 21/1 - 6 dB Directional Coupler 800-2700 N(f) Brochure

    ZHC 901 21/2 - 10 dB Directional Coupler 800-2700 N(f) Brochure

    ZHC 901 21/3 - 15 dB Directional Coupler 800-2700 N(f) Brochure

    ZHC 901 21/4 - 20 dB Directional Coupler 800-2700 N(f) Brochure

    ZHC 901 21/5 - 30 dB Directional Coupler 800-2700 N(f) Brochure

    UML 901 08/1 - Terminating load, 2 W 0-3000 N(m) -

    ZYA 402 05/1 Kathrein K62 26 21 1

    Terminating load, 25 W 0-2200 N(m) 1301-spec

  • Ericsson Internal STANDARD MODULE OVERVIEW 5 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    4.3 Fire retardant feeder cables

    Ericsson P/N Description Diameter [mm]

    Minimum bending radius [mm]

    FAB 102 1044/05 3/8" LDF2 fire retardant feeder cable on drum, 300 m 11 95

    FAB 102 1044/02 3/8" LDF2 fire retardant feeder cable on drum, 500 m 11 95

    FAB 102 1044/04 1/2" LDF4 fire retardant feeder cable on drum, 300 m 16 125

    FAB 102 1044/01 1/2" LDF4 fire retardant feeder cable on drum, 500 m 16 125

    FAB 102 1943/2 7/8" AVA5 fire retardant feeder cable on drum, 300 m 29 254

    FAB 102 1943/1 7/8" AVA5 fire retardant feeder cable on drum, 500 m 29 254

    FAB 102 989/1 1 1/4" LDF6 fire retardant feeder cable on drum, 400m 39,8 380

    FAB 102 1944/1 1 5/8" AVA7 fire retardant feeder cable on drum, 300 m 51,1 385

    The feeder cables are UV-resistant, halogen free according to IEC 754-2 and fire retardant according to CATVR/ UL 1666 (riser cabel test) CATV/ UL 1581(vertical tray flame test), IEC 60332-3(vertical bunched cabel), IEEE 383 (vertical tray flame test) CATVX/ UL VW-1 (vertical wire flame test), IEC 60332-1(vertical single cable).

    The feeder cables are suitable for indoor and outdoor use.

    Minimum bending radius data refers to repeated bending (guaranteed minimum number of bends: 15).

    Note: Recommended tools: Feeder preparation and installation tool sets can be found in Implementation Team Products Standard Module Overview, 131 22-COH 109 395.

    If fire retardant properties are not required, lower cost standard feeder cables can be found in the Feeder System Standard Module Overview, 131 22-COH 109 393/3. Connectors will fit as long as the cable has the same size and code, e.g. 7/8 AVA5.

    If CATVP (plenum), UL 910 cables are required, typical for ducts and plenums, please contact Strategic Product Manager for more information.

  • Ericsson Internal STANDARD MODULE OVERVIEW 6 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    4.4 Connectors

    Ericsson P/N Description

    RPT 403 179/01 N (m) connector for 3/8" LDF2 feeder cable

    RPT 899 024/1 N (m) positive stop connector, 1/2" LDF4

    RNT 899 065/1 N (f) positive stop connector, 1/2" LDF4

    RPT 899 95/1 N (m) positive stop connector, 7/8" AVA5 and AL5

    RNT 899 066/1 N (f) positive stop connector, 7/8" AVA5, and AL5

    RPT 899 97/1 N(m) one piece connector, 1 1/4" LDF6

    RPT 987 25/1 N (m) positive stop connector, 1 5/8" AVA7 and AL7

    RNT 899 067/1 N (f) positive stop connector, 1 5/8" AVA7 and AL7

    Note: Recommended tools: Feeder preparation and installation tool sets can be found in Implementation Team Products Standard Module Overview, 131 22-COH 109 395.

    If DIN 7-16 connectors are required, they can be found in the Feeder System Standard Module Overview, 131 22-COH 109 393/3.

  • Ericsson Internal STANDARD MODULE OVERVIEW 7 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    4.5 1/4" jumper cables

    Ericsson P/N Connectors Length [m] Jumper loss [dB] (including 0,2 dB connector loss)

    900 MHz 1800 MHz 2000 MHz 2200 MHz

    TSR 951 101/01 N(m) - N(f) 0,5 0,3 0,35 0,35 0,35

    TSR 951 101/02 N(m) - N(f) 1 0,4 0,45 0,5 0,5

    TSR 951 101/03 N(m) - N(f) 2 0,6 0,75 0,75 0,8

    TSR 951 103/1 N(m) - N(m) 0,5 0,3 0,35 0,35 0,35

    TSR 951 103/2 N(m) - N(m) 1 0,4 0,45 0,5 0,5

    TSR 951 103/3 N(m) - N(m) 2 0,6 0,75 0,75 0,8

    Cable data:

    1/4" FSJ1 is UV-resistant, halogen free according to IEC 754-2 and have fire retardant jacketing according to: CATVR/ UL 1666 (riser cabel test) Therfore, cabels meeting this requirement can also be used in the folowing lower level categories: CATV/ UL 1581(vertical tray flame test), IEC 60332-3(vertical bunched wires or cabel), IEEE 383 (vertical tray flame test) CATVX/ UL VW-1 (vertical wire flame test), IEC 60332-1(vertical single wire or cable).

    The jumpers are suitable for indoor and outdoor use.

    Diameter: 7,4 mm Minimum bending radius: 25 mm (repeated bending, guaranteed minimum number of bends: 15).

    Note: If fire retardant jumper cables with DIN 7-16 interface are required, they can be found in the Feeder System Standard Module Overview, 131 22-COH 109 393/3.

    4.6 Adapters

    Ericsson P/N Description

    RPT 403 182/01 Adapter N(m) - 7-16(m)

    RPT 403 181/01 Adapter N(f) - 7-16(m)

    RPT 403 184/01 Adapter N(m) - TNC(m)

    RPT 403 180/01 Adapter N(f) - TNC(m)

    RPT 403 183/01 Adapter N(m) - N(m)

    RPT 899 89/1 Adapter N(m) - N(f), right angle

  • Ericsson Internal STANDARD MODULE OVERVIEW 8 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    5 Other products

    5.1 In-building antennas

    Ericsson P/N Supplier P/N Height[mm]

    f [MHz]

    HBW []

    Gain [dBi]

    Connector Links

    KRE 101 1941/1 Kathrein 741 573

    64 1710-2500 Omni 2 N(f) 1301-spec

    5.2 Antenna near products

    Ericsson P/N Supplier P/N Description f [MHz]

    Connector Links

    KRF 102 186/1 - Triplex combiner with power monitoring port

    806-960+ 1710-1880+ 1920-2170

    N(f) Brochure

    KRF 102 217/1 Kathrein 791 145

    Diplex filter 50-1000+ 1600-2000

    N(f) 1301-spec

    KRF 102 239/1 Kathrein K63 23 60 01

    Adjustable power tapper 824-960+ 1710-2170

    N(f) 1301-spec

    KRF 102 248/1 Kathrein 860 10023

    Adjustable power tapper 870-960+ 1710-2500

    N(f) 1301-spec

    ZHC 901 22/1 - Hybrid coupler, 3 dB 800-2700 N(f) Brochure

    KRF 111 53/2 Microlab/FXR CA-84D

    Hybrid coupler, 3 dB 700-2700 7-16(f) 1301-spec

    ZYA 402 02/1 Kathrein K62 26 30 1

    Terminating load, 50 W 0-2200 N(f) 1301-spec

  • Ericsson Internal STANDARD MODULE OVERVIEW 9 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    5.3 Radiating cables

    Ericsson P/N Description

    FAB 102 801/01 3/8" Andrew RXL2-2RNT radiating cable on 250 m drum

    FAB 102 805/01 Installation kit for 3/8" radiating cable (2x N(f) connectors, 2 W load, sealing set)

    FAB 102 802/01 1/2" Andrew RXL4-1RNT radiating cable on 250 m drum

    FAB 102 806/01 Installation kit for 1/2" radiating cable (2x N(f) connectors, 2 W load, sealing set)

    FAB 102 803/01 7/8" Andrew RXL5-1RNT radiating cable on 500 m drum

    FAB 102 807/01 Installation kit for 7/8" radiating cable (2x 7-16(f) connectors, 20 W load, sealing set)

    FAB 102 804/01 1 1/4" Andrew RXL6-1RNT radiating cable on 300 m drum

    FAB 102 808/01 Installation kit for 1 1/4" radiating cable (2x 7-16(f) connectors, 20 W load, sealing set)

    The radiating cables are halogen free according to IEC 754-2 and have fire retardant jacketing according to CATVR/ UL 1666 (riser cabel test) CATV/ UL 1581(vertical tray flame test), IEC 60332-3(vertical bunched cabel), IEEE 383 (vertical tray flame test) CATVX/ UL VW-1 (vertical wire flame test), IEC 60332-1(vertical single cable).

    The radiating cables are only suitable for indoor use, i.e. not UV protected.

    Radiating cables exhibit a fading characteristic that is a result of the multi path nature of the cable. Typically, a fade will occur approximately every wavelength. The depth of the fade is dependant not only on the cable design but also on the multi path environment. The depth of fading can be quantified by calculating the ratio between the median value of the coupling loss (50%) to the coupling loss that occurs less than 5% of the time. This produces the ratio of the 50 to 95% values. For the coupled mode RXL cables above that ratio is typically 11 dB. By adding that factor to the 50% coupling loss values stated in the table below, the approximate level that will be achieved at least 95% of the time at the terminated end of the cable at 2 m distance can be derived.

    900 MHz 1800 MHz 2400 MHz

    Ericsson P/N Attenuation [dB/100 m]

    50% coupling loss

    at 2 m [dB10dB]

    Attenuation[dB/100 m]

    50% coupling loss

    at 2 m [dB10dB]

    Attenuation [dB/100 m]

    50% coupling loss

    at 2 m [dB10dB]

    Diameter[mm]

    Minimum bending radius[mm]

    FAB 102 801/01 12,1 68 17,4 74 20,8 74 11 95

    FAB 102 802/01 9,5 68 13,1 73 15,7 73 19 125

    FAB 102 803/01 5,1 72 7,6 84 9,2 76 29 254

    FAB 102 804/01 4,0 77 5,6 84 6,9 76 41 380

    The attenuation and 50% coupling loss data is valid for a radiating cable spaced 5 cm from a wall.

  • Ericsson Internal STANDARD MODULE OVERVIEW 10 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    6 Phase out products

    6.1 In-building antennas

    Ericsson P/N Supplier P/N Height[mm]

    f [MHz]

    HBW []

    Gain [dBi]

    Connector Links

    KRE 101 1861/1 Kathrein 741 572

    78 824-960+1429-2170

    Omni 2 N(f) 1301-spec

    6.2 Antenna near products

    Ericsson P/N Supplier P/N Description f [MHz]

    Connector Links

    KRF 102 246/2 Kathrein 860 10017

    2-way power splitter 800-2500 N(f) 1301-spec

    KRF 102 246/3 Kathrein 860 10018

    3-way power splitter 800-2500 N(f) 1301-spec

    KRF 102 246/4 Kathrein 860 10019

    4-way power splitter 800-2500 N(f) 1301-spec

    KRF 102 247/1 Kathrein 860 10020

    7 dB power tapper 800-2500 N(f) 1301-spec

    KRF 102 247/2 Kathrein 860 10021

    10 dB power tapper 800-2500 N(f) 1301-spec

    KRF 102 247/3 Kathrein 860 10022

    15 dB power tapper 800-2500 N(f) 1301-spec

    ZYA 402 04/1 Kathrein K62 26 11 1

    Terminating load, 2 W 0-2200 N(m) 1301-spec

    6.3 Fire retardant feeder cables

    Ericsson P/N Description Diameter [mm]

    Minimum bending radius [mm]

    FAB 102 1044/06 7/8" LDF5 fire retardant feeder cable on 300 m drum 28 250

    FAB 102 1044/03 7/8" LDF5 fire retardant feeder cable on 500 m drum 28 250

  • Ericsson Internal STANDARD MODULE OVERVIEW 11 (11)

    Prepared (also subject responsible if other) No.

    EAB/FJN/SR Niklas Hoppe 131 22-COH 109 396/1 Uen Approved Checked Date Rev Reference

    EAB/FJN/SR [Aart Hasselaar] 2007-04-17 F

    6.4 Connectors

    Ericsson P/N Description

    RPT 403 178/01 N (m) connector for 1/2" LDF4 feeder cable

    RPT 403 177/01 N (m) connector for 7/8" LDF5 feeder cable

    6.5 Antenna near products

    Ericsson P/N Supplier P/N Description f [MHz]

    Connector Links

    KRF 111 53/1 Microlab/FXR CA-84N

    Hybrid coupler 700-2700 N(f) 1301-spec

    7 Terminology and abbreviations

    f Frequency

    HBW Horizontal beam width P/N Product number

    1 Revision history 2 Introduction3 Reading and using this document4 Preferred products4.1 In-building antennas4.2 Antenna near products4.3 Fire retardant feeder cables4.4 Connectors4.5 1/4" jumper cables4.6 Adapters

    5 Other products5.1 In-building antennas5.2 Antenna near products5.3 Radiating cables

    6 Phase out products6.1 In-building antennas6.2 Antenna near products6.3 Fire retardant feeder cables6.4 Connectors6.5 Antenna near products

    7 Terminology and abbreviations