Introduction

Introduction of the product range The RXM miniature relay range includes:1 12 A relays with 2 C/O contacts, 10 A relays with 3 C/O contacts, 6 A relays with

4 C/O contacts and 3 A “low level” relays with 4 C/O contacts. All these relays have the same dimensions.

2 Sockets with mixed or separate contact terminals.3 Protection modules (diode, RC circuit or varistor).4 Metal hold-down clip for all sockets.5 Plastic hold-down ejector clip for all sockets.6 2-pole bus jumper that can be used on sockets with separate contact terminals

in order to simplify wiring when creating a jumper between the coil terminals.7 Clip-in ID tags for all the sockets except RXZE2M114.

Relay description1 Spring return push-to-test button for checking contact operation (green: DC coil,

red: AC coil).2 Mechanical “relay status” indicator.3 Optional removable lock-down door enables continuous engagement of the

contacts for test or maintenance purposes. During normal operation, this lock-down door must always be in the closed position.

4 Bipolar LED indicating the relay status.5 Removable ID tag for relay identification.6 Four notches for DIN rail mounting adapter or panel mounting adapter with

mounting lugs.7 Eight, eleven or fourteen quick-connect pins.8 Finger grips for easy removal of the relay from a socket.9 Mounting adapter for direct mounting of the relay on a panel.10 Mounting adapter for direct mounting of the relay on a DIN rail.

Socket description Sockets with mixed contact terminals (1)

1 Connection by screw clamp terminals or box lug connector.2 Fourteen female contacts for the relay pins.3 Location for protection modules.4 Locking components for plastic and metal hold-down clips.5 Locating slot for mounting on DIN rail.6 Two or four mounting holes for panel mounting.

Sockets with separate contact terminals (2)1 Connection by screw connector.2 Connection by push-in spring clamp terminals. No tool is required to insert the

cable.3 Eight, eleven or fourteen female contacts for the relay pins.4 Location for protection modules.5 Locking components for plastic and metal hold-down clips. 6 Locating slot for mounting on DIN rail.7 Two mounting holes for panel mounting.8 Location for bus jumpers (see “Mounting on Sockets” section on

www.schneider-electric.com).9 Location for clip-in ID tag.

(1) The inputs are mixed with the relay coil terminals, with the outputs being located on the opposite side of the socket.

(2) The inputs and outputs are separated from the relay coil terminals.

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

9 9 10

2

6 9

17

3

45

6 8

Outputs

Inputs

Relay coil terminals6

1

2

3

4

5

Outputs

Inputs

Relay coil terminals

5

6

12

7

3

4

56

8

7

6

2

1

5

3

4

or

Page 4: RXM miniature relays

4

Zelio™ Plug-In RelaysRXM miniature relays

Specifications

General specificationsConforming to standards IEC/EN 61810-1, UL 508, CSA C22-2 n° 14Product certifications cULus File E164862 CCN NLDX, NLDX7; cURus File E164862 CCN NLDX2, NLDX8; CSA; CE; Lloyds

Register; GOST; RoHS compliantAmbient air temperature around the device

Storage °C (F) - 40… + 85 (-40... +185)Operation °C (F) - 40… + 55 (-40... +131)

Vibration resistanceconforming to IEC/EN 60068-2-6

In operation 3 gn (35...150 Hz), +/- 1 mm (10...35 Hz) with and without retention clipNot operating 5 gn (35...150 Hz), +/- 1 mm (10...35 Hz) with and without retention clip

Degree of protection Conforming to IEC/EN 60529

IP 40

Shock resistanceconforming to IEC/EN 60068-2-27

In operation 10 gn (11 ms) with retention clipNot operating 30 gn (11 ms) with retention clip

Protection category RT IMounting position Any

Insulation specificationsRated insulation voltage (Ui) V 250 (IEC), 300 (UL, CSA)Rated impulse withstand voltage (Uimp) kV 4 (1.2/50 ms) for RXM 2ppppp and RXM 3ppppp; 2.5 (1.2/50 ms) for RXM 4pppppDielectric strength(rms voltage)

Between coil/contact Vac 2000Between poles Vac 2000Between contacts Vac 1300

Contact specificationsRelay type RXM 2ABppp RXM 3ABppp RXM 4ABppp RXM 4GBppp

Number and type of contacts 2 C/O 3 C/O 4 C/O 4 C/O low levelContact materials Ag alloy with Au flash Ag with Au flash -

bifurcatedConventional thermal current (Ith)

For ambient temperature y 55 °C

A 12 10 6 3

Rated operational current in utilization categories AC-1 and DC-1

Conforming to IEC

N.O. 12 10 6 2N.C. 6 5 3 1

Switching current Minimum mA 10 3Switching voltage Maximum V 250 Vac / 28 Vdc (IEC); 300 Vac / 30 Vdc (UL)

Minimum V 17 Vdc 5 VdcNominal load (conforming to IEC, resistive, 100K cycles)

A 12 at 250 Vac (100K cycles) 10 at 250 Vac (100K cycles) 6 at 250 Vac (100K cycles) 3 at 250 Vac (100K cycles)(1)

A 12 at 28 Vdc (100K cycles) 10 at 28 Vdc (100K cycles) 6 at 28 Vdc (100K cycles) 3 at 28 Vdc (100K cycles)(1)

Rated operational current (conforming to UL)

Resistive A 12 at 277 Vac (100K cycles) 10 at 277 Vac (100K cycles) 6 at 277 Vac (200K cycles) 3 at 277 Vac (100K cycles)(1)A 12 at 120 Vac (200K cycles) 10 at 120 Vac (200K cycles) 8 at 120 Vac (200K cycles) 3 at 120 Vdc (100K cycles)(1)A 12 at 30 Vdc (100K cycles) 10 at 30 Vdc (100K cycles) 8 at 30 Vdc (200K cycles) 3 at 30 Vdc (100K cycles)(1)

Motor hp 1/2 at 120 Vac (6K cycles) 1/3 at 120 Vac (6K cycles) 1/3 at 120 Vac (6K cycles) 1/16 at 120 Vac (6K cycles)(1)hp 1 at 277 Vac (6K cycles) 1 at 277 Vac (6K cycles) 1/2 at 277 Vac (6K cycles) 2.8 A FLA at 120 Vac

Pilot Duty B300 B300 B300 5 A make, 0.5 A break, 3A continuous at 120 Vac(1)

Switching capacity Maximum AC VA 3000 2500 1500 750DC W 336 280 168 84

Minimum mW 170 15Maximum operating rateIn operating cycles per hour

No-load 18 000Under load 1200

Utilization coefficient 20 %Mechanical durability Cycles 10 000 000(1) When mounted horizontally

Electrical durability of contactsResistive load (AC)

Reduction coefficient for inductive load (AC) (depending on power factor cos j)

Maximum switching capacity on resistive load (DC)

A RXM 2ABppp B RXM 3ABppp C RXM 4ABppp D RXM 4GBppp Durability (inductive load) = durability (resistive load) x reduction coefficient.

105

106

107

2 30 1

A BDC

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,81

Red

uctio

n co

effic

ient

(A)

0,1

1

200 2500 5028 100 150

10

3

6

CDBA

Cur

rent

c

Voltage (Vdc)

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

Page 5: RXM miniature relays

5

Zelio™ Plug-In RelaysRXM miniature relays

Specifications (continued)

Coil specificationsAverage consumption AC VA 0.9–1.2

DC W 0.8–1.1Drop-out voltage threshold AC u 0.15 Uc

DC u 0.1 UcOperating time(response time)

Between coil energization and making of the On-delay contact

AC ms 20 (max.)DC ms 20 (max.)

Between coil de-energization and making of the Off-delay contact

AC ms 20 (max.)DC ms 20 (max.)

Control circuit voltage Uc V 12 24 48 110 120 125 220 230 240Relay control voltage codes JD BD ED FD – GD MD – –

DC supply Average resistance at 20 °C ± 10% W 160 650 2560 13 440 – 17 360 48 400 – –Operating voltage limits Min. Vac 9.6 19.2 38.4 88 – 100 176 – –

Max. Vac 13.2 26.4 52.8 121 – 138 242 – –Relay control voltage codes – B7 E7 F7 – – P7 U7

AC supply Average resistance at 20 °C ± 15% W – 177 708 – 3630 – – 16 270 17 720Operating voltage limits Min. Vdc – 19.2 38.4 – 96 – – 184 192

Max. Vdc – 26.4 52.8 – 132 – – 253 264

Socket specificationsSocket type RXZE2S108M RXZE2S111M RXZE2S114M RXZE2S114S RXZE2M114M RXZE2M114Relay types used RXM2ppppp RXM3ppppp RXM4ppppp RXM2ppppp

RXM4pppppRXM2ppppp (1)RXM4ppppp

RXM2ppppp (1)RXM4ppppp

Contact terminal arrangement Separate MixedWire connection method Box lug connectors Spring clamp

terminalsBox lug connectors Screw clamp

terminalsProduct certifications cURus File E172326 CCN SWIV2, SWIV8; CSA; CE; GOST; Lloyds; RoHS compliantConforming to standards IEC 61984, UL 508, CSA 22.2 No. 14

Electrical specificationsConventional thermal current (Ith) A 12 10 12 (2-Pole),

6 (4-Pole)10

Maximum operating voltage Vac 250 (IEC)

Insulation specificationsBetween adjacent output contacts Vrms 2500Between input and output contacts Vrms 2500Between contacts and DIN rail Vrms 2500

General specificationsAmbient air temperaturearound the device

Operation °C (°F) - 40…+ 40 (- 40…+ 104)Storage °C (°F) - 40…+ 85 (- 40…+ 185)

Degree of protection Conforming to IEC/EN 60529

IP 20

Connection Solid wire without cable end

1 conductor 0.5…2.5 mm2 - AWG 20…AWG 14 0.5…1.5 mm2 AWG 20…AWG 16

0.5…2.5 mm2 AWG 20…AWG 14

0.5… 1.5 mm2 AWG 20…AWG 16

2 conductors 0.5…1.5 mm2 - AWG 20…AWG 16Flexible wire with cable end

1 conductor 0.25…2.5 mm2 - AWG 22…AWG 14 0.5…1.5 mm2 AWG 20…AWG 16

0.25…2.5 mm2 AWG 22…AWG 14

0.25…1 mm2

AWG 22…AWG 172 conductors 0.25…1 mm2 - AWG 22…AWG 17 0.5…1.5 mm2

AWG 20…AWG 160.25…1 mm2 - AWG 22…AWG 17

Maximum tightening torque / Screw size Nm 1 / M3 screwMounting On 35 mm DIN rail / on panelMounting on DIN rail By plastic clip By metal

compression spring

By plastic clip

Terminal referencing IEC, NEMABus jumper (Ith: 5 A) Yes NoCompatibility with the plastic hold-down ejector clip

Yes

Compatibility with the metal hold-down clip YesProtection module compatibility All RXM040W, RXM041pp, RXM021pp

Clip-in ID tag compatibility Yes (see page 6 for more information) NoWire connection method Screw connector Spring clamp

terminalsScrew connector Screw clamp

terminals

(1) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.

(1) (2)

mmin.

mmin.

9 ~ 110.35 ~ 0.43

2.5

0.09

8

F

F

1 2

1 2 3 4

F

F F

F

F

F

Page 6: RXM miniature relays

6

Zelio™ Plug-In RelaysRXM miniature relays

References

Miniature relays with lockable test button only (sold in lots of 10) Control circuit voltage

Number and type of contacts - Thermal current (Ith)2 C/O - 12 A 3 C/O - 10 A 4 C/O - 6 AUnit reference

Weight Unit reference

Weight Unit reference

Weight

V kg (lb) kg (lb) kg (lb)12 Vdc RXM2AB1JD 0.037 (0.082) RXM3AB1JD 0.037 (0.082) RXM4AB1JD 0.037 (0.082)24 Vdc RXM2AB1BD 0.037 (0.082) RXM3AB1BD 0.037 (0.082) RXM4AB1BD 0.037 (0.082)48 Vdc RXM2AB1ED 0.037 (0.082) RXM3AB1ED 0.037 (0.082) RXM4AB1ED 0.037 (0.082)110 Vdc RXM2AB1FD 0.037 (0.082) RXM3AB1FD 0.037 (0.082) RXM4AB1FD 0.037 (0.082)220 Vdc – – – – RXM4AB1MD 0.037 (0.082)

24 Vac RXM2AB1B7 0.037 (0.082) RXM3AB1B7 0.037 (0.082) RXM4AB1B7 0.037 (0.082)48 Vac RXM2AB1E7 0.037 (0.082) RXM3AB1E7 0.037 (0.082) RXM4AB1E7 0.037 (0.082)120 Vac RXM2AB1F7 0.037 (0.082) RXM3AB1F7 0.037 (0.082) RXM4AB1F7 0.037 (0.082)230 Vac RXM2AB1P7 0.037 (0.082) RXM3AB1P7 0.037 (0.082) RXM4AB1P7 0.037 (0.082)240 Vac – – – – RXM4AB1U7 0.037 (0.082)

Miniature relays with LED and lockable test button (sold in lots of 10) 12 Vdc RXM2AB2JD 0.037 (0.082) RXM3AB2JD 0.037 (0.082) RXM4AB2JD 0.037 (0.082)24 Vdc RXM2AB2BD 0.037 (0.082) RXM3AB2BD 0.037 (0.082) RXM4AB2BD 0.037 (0.082)48 Vdc RXM2AB2ED 0.037 (0.082) RXM3AB2ED 0.037 (0.082) RXM4AB2ED 0.037 (0.082)110 Vdc RXM2AB2FD 0.037 (0.082) RXM3AB2FD 0.037 (0.082) RXM4AB2FD 0.037 (0.082)125 Vdc – – – – RXM4AB2GD 0.037 (0.082)

24 Vac RXM2AB2B7 0.037 (0.082) RXM3AB2B7 0.037 (0.082) RXM4AB2B7 0.037 (0.082)48 Vac RXM2AB2E7 0.037 (0.082) RXM3AB2E7 0.037 (0.082) RXM4AB2E7 0.037 (0.082)120 Vac RXM2AB2F7 0.037 (0.082) RXM3AB2F7 0.037 (0.082) RXM4AB2F7 0.037 (0.082)230 Vac RXM2AB2P7 0.037 (0.082) RXM3AB2P7 0.037 (0.082) RXM4AB2P7 0.037 (0.082)

Miniature relays with LED only (sold in lots of 10) 12 Vdc RXM2AB3JD 0.037 (0.082) – – RXM4AB3JD 0.037 (0.082)24 Vdc RXM2AB3BD 0.037 (0.082) – – RXM4AB3BD 0.037 (0.082)110 Vdc RXM2AB3FD 0.037 (0.082) – – RXM4AB3FD 0.037 (0.082)125 Vdc – – – – RXM4AB3GD 0.037 (0.082)

24 Vac RXM2AB3B7 0.037 (0.082) – – RXM4AB3B7 0.037 (0.082)48 Vac RXM2AB3E7 0.037 (0.082) – – RXM4AB3E7 0.037 (0.082)120 Vac RXM2AB3F7 0.037 (0.082) – – RXM4AB3F7 0.037 (0.082)230 Vac RXM2AB3P7 0.037 (0.082) – – RXM4AB3P7 0.037 (0.082)

RXM4AB1BD

RXM4AB1F7

RXM4AB2BD

RXM4AB2F7

RXM2AB3F7

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

Page 7: RXM miniature relays

7

Zelio™ Plug-In RelaysRXM miniature relays

References (continued)

Miniature relays with low level contacts, lockable test button only (sold in lots of 10) Control circuit voltage

Number and type of contacts Thermal current (Ith)4 C/O - 3 AUnit reference

Weight

V kg (lb)12 Vdc RXM4GB1JD 0.037 (0.082)24 Vdc RXM4GB1BD 0.037 (0.082)48 Vdc RXM4GB1ED 0.037 (0.082)110 Vdc RXM4GB1FD 0.037 (0.082)

24 Vac RXM4GB1B7 0.037 (0.082)48 Vac RXM4GB1E7 0.037 (0.082)120 Vac RXM4GB1F7 0.037 (0.082)230 Vac RXM4GB1P7 0.037 (0.082)

Miniature relays with low level contacts, with LED and lockable test button (sold in lots of 10) 12 Vdc RXM4GB2JD 0.037 (0.082)24 Vdc RXM4GB2BD 0.037 (0.082)48 Vdc RXM4GB2ED 0.037 (0.082)110 Vdc RXM4GB2FD 0.037 (0.082)

24 Vac RXM4GB2B7 0.037 (0.082)48 Vac RXM4GB2E7 0.037 (0.082)120 Vac RXM4GB2F7 0.037 (0.082)230 Vac RXM4GB2P7 0.037 (0.082)240 Vac RXM4GB2U7 0.037 (0.082)

Miniature relays with low level contacts, with LED only (sold in lots of 10) 12 Vdc RXM4GB3JD 0.037 (0.082)24 Vdc RXM4GB3BD 0.037 (0.082)48 Vdc RXM4GB3ED 0.037 (0.082)110 Vdc RXM4GB3FD 0.037 (0.082)

24 Vac RXM4GB3B7 0.037 (0.082)48 Vac RXM4GB3E7 0.037 (0.082)120 Vac RXM4GB3F7 0.037 (0.082)230 Vac RXM4GB3P7 0.037 (0.082)

RXM4GB1BD

RXM4GB2BD

RXM4GB3F7

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

Page 8: RXM miniature relays

8

Zelio™ Plug-In RelaysRXM miniature relays

References (continued)

SocketsContact terminal arrangement

Connection Relay type Sold in lots of

Unit reference

Weightkg (lb)

Mixed Screw clamp terminals RXM2pppp (3)RXM4pppp

10 RXZE2M114 (1) 0.048 (0.106)

Screw connector RXM2pppp (3)RXM4pppp

10 RXZE2M114M (1) 0.056 (0.124)

Separate Spring clamp terminals RXM2pppp (3)RXM4pppp

10 RXZE2S114S (2) 0.070 (0.154)

Box lug connector RXM2pppp 10 RXZE2S108M (2) 0.058 (0.128)RXM3pppp 10 RXZE2S111M (1) 0.066 (0.146)RXM4pppp 10 RXZE2S114M (1) 0.070 (0.154)

Protection modulesDescription Voltage For

use withSold in lots of

Unit reference

Weight

V kg (lb)Diode 6...250 Vdc All sockets 20 RXM040W 0.003 (0.007)

RC circuit 24...60 Vac All sockets 20 RXM041BN7 0.010 (0.022)110...240 Vac All sockets 20 RXM041FU7 0.010 (0.022)

Varistor 6...24 Vac / Vdc All sockets 20 RXM021RB 0.003 (0.007)24...60 Vac / Vdc All sockets 20 RXM021BN 0.003 (0.007)110...240 Vac / Vdc All sockets 20 RXM021FP 0.003 (0.007)

Timing relaysDescription For

use withUnit reference

2 or 4 timed C/O contacts Sockets RXZEppppp REXL2pp (4) REXL4pp (4)

AccessoriesDescription For

use withSold in lots of

Unit reference

Weightkg (lb)

Metal hold-down clip All sockets 10 RXZ400 0.001 (0.002)Plastic hold-down ejector clip All sockets 10 RXZR335 0.005 (0.011)Bus jumper 2-pole (Ith: 5 A) All sockets with separate contacts 10 RXZS2 0.005 (0.011)

Mounting adapter for DIN rails (5)

All relays 10 RXZE2DA 0.004 (0.009)

Mounting adapter with mounting lugs for panel

All relays 10 RXZE2FA 0.002 (0.004)

Clip-in ID tags All relays (sheet of 108 legends) 10 RXZL520 0.080 (0.176)All sockets except RXZE2M114 and RXZE2S114S 10 RXZL420 0.001 (0.002)RXZE2S114S socket 10 RSZL300 0.001 (0.002)

(1) Thermal current Ith: 10A(2) Thermal current Ith: 12A(3) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A. (4) Please consult the "Zelio Time timing relays" catalog.(5) Test button becomes inaccessible if used with DIN rail mounting adapter or panel mounting adapter and terminals face the user.

RXZ400

RXM041pp7

RXZE2M114M + Relay RXM4AB1F7

REXL4pp

Page 9: RXM miniature relays

9

Zelio™ Plug-In RelaysRXM miniature relays

Dimensions

DimensionsMiniature relaysRXMpppppp RXM2 RXM3 RXM4

Common view Pin side view

SocketsRXZE2M114 RXZE2M114M

Common side view RXZE2S108M RXZE2S111M RXZE2S114M

(1) Relays(2) Protection module(3) Metal hold-down clip(4) 2 elongated holes Ø 3.5 x 6.5(5) 2 bus jumpers

(1)

(2)(3)

25.51.00

347

A214

A113

246

448

145

12

1

11

9

21

10

31

11

41

12

22

2

32

3

42

4

(4)19

0.75

401.58

301.18

90.3523

0.91

210.8330

1.18692.72

70.28

39.5

1.56

61 2.40

3.5

0.14

79 3.11

(4)

mmin.

3.50.14

170.67

431.69

23.50.93

501.97 27

1.0667

2.64

40 1.58

80 3.15

448

347

246

145

424

323

222

121

A1

13

A2

1441

12

31

11

21

10

11

9

(3)

(1)

(2)

mmin.

70.28

3.50.14

190.75

612.40

291.14

230.91 70

2.767

0.28

3.5

0.14

79 3.11

(3) (2)

(1)

(5)

mmin.

23.50.9327

1.06

38 1.50

4112

119

448

145

A113

A214

424

121

3.50.14

319

346

A1

13

A2

14

323

218

245

222

117

144

121

23.50.9327

1.06

38 1.50

3.50.14

23.50.9327

1.06

38 1.50

3.50.14

4112

3111

2110

119

448

347

246

145

42

4

32

3

22

2

12

1

A1

13

A2

14

401.58

210.83

27 1.06

90.35

60.24

2.50.10

2.50.10

21

6.3

0.25

6.3

0.25

4.2

0.17

4.2

0.17

13.20.52

2.50.10

2.50.10

4.40.17

21

13.20.52

6.60.26

6.60.26

2.50.10

2.50.1013.2

0.52

4.40.17

4.40.17

4.40.17

mmin.

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

Page 10: RXM miniature relays

10

mmin.

311.22

94 3.70

281.10

(4)

(1)

(2)

(3)

98 3.86

522.05

702.76

803.15

Dimensions (continued)Sockets (continued)RXZE2S114S Socket only RXZE2S114S Socket with RXM relay and retention clip

(1) Relay(2) Protection module(3) Metal retention clip(4) I.D. tag

RXZE2S114S Socket with RXM relay and ejector clip

(1) Relay(2) Protection module(3) Ejector clip(4) I.D. tag

Zelio™ Plug-In RelaysRXM miniature relays

Dimensions (continued)

mmin.

311.22

94 3.70

281.10

(4)

(1)

(2)

(3)

98 3.86

522.05

702.76

762.99

35.51.40mm

in.29.51.16

23.50.93

311.2222

0.877.5

0.30

94 3.70 90 3.

54

15 0.59

28 1.10

48 1.89

1.2

0.05

Plastic ejector clip RXZR335 Metal retention clip RXZ400 ID tag RSZL300

572.24

27 1.06

8.0

0.3

14.50.6

7.20.3

22 0.87

421.65

0.80.03

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

Page 11: RXM miniature relays

11

Zelio™ Plug-In RelaysRXM miniature relays

Dimensions (continued)

Dimensions (continued)Plastic hold-down clip and clip-in ID tagsRXZR335 RXZL420 Mounting on all sockets (1)

(1) Clip-in ID tags for all sockets except RXZE2M114

Bus jumper Metal hold-down clipRXZS2 Mounting on sockets with separate contacts

(view from below)RXZ400

Example of bus jumper mounting on sockets

(1) 2 bus jumpers (polarity A2)(2) 2 bus jumpers (polarity A1)

Mounting adapter for rails (1) Mounting adapter for panelRXZE2DA RXZE2FA

(1) Test button becomes inaccessible

572.24

27 1.06

12

14,2

26,5

81

94,5

(1)

2,2 7,

3

25

22

2,3(1)(1)

(2)(2)

22 0.87

421.65

0.80.03

38

6 424

348

23

51

48 49

3,5

43 38

4

24

3,5

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

Page 12: RXM miniature relays

12

Wiring diagramsMiniature relaysRXM2ppppp RXM3ppppp RXM4ppppp

Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.

Sockets RXZE2M114 RXZE2M114M RXZE2S108M

347

14A2 A1

13

246

844 14

5

1

119

2110

3111

4112

2312223242

4

448

347

246

145

12312223242

4

14A2 A1

13

14 13

1021

9

9

5

1

111131

1241

1241 11

9

844 14

5

A1

13

A2

A1A214

424

121

INPUT

Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.RXZE2S111M RXZE2S114M RXZE2S114S

A1

13

A2

A1A214

319

346

3

218

245

2

117

144

32 22 121

INPUT

A1

13

A2

A1A214

4112

3111

2110

119

448

347

246

145

424

323

222

121

INPUT

Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.Protection modules RXM040W RXM041ppp RXM021ppp

– A2

+ A1

– A2

+ A1

– A2

+ A1

A2

A1

414442

111412

1

125

149

11

4

428

4412

4113

A1

14

A2

A2

A1

313432

212422

111412

1

12

4

147

11

2

22

5

248

21

3

32

6

349

3113

A1

14

A2

A2

A1

414442

212422

313432

111412

1

125

149

11

4

428

4412

41

2

226

2410

21

3

327

3411

3113

A1

14

A2

Zelio™ Plug-In RelaysRXM miniature relays

Wiring diagrams

4112

424

448

3111

323

347

2110

222

246

119

14 13

12

A2 A1

A2 A1

14 13

1

145

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

Page 13: RXM miniature relays

13

Wiring instructions for RXZE2S114S socketRecommended wire strip length Recommended removal tool: flat blade,

parallel tipOpenings for wiring and removal tool

(1) Wiring opening(2) Removal tool opening

Wiring insertion Wiring removal

Recommended wiring for RXZE2S114S socketFlexible wiring with cable end

1 wire 0.5 to 1.5 mm2 – 20 to 16 AWG

2 wires 0.5 to 1.5 mm2 – 20 to 16 AWG

Solid wiring without cable end

1 wire 0.5 to 1.5 mm2 – 20 to 16 AWG

2 wires 0.5 to 1.5 mm2 – 20 to 16 AWGNote: Allow only one wire per terminal opening

(1) (2)

mmin.

mmin.

9 ~ 110.35 ~ 0.43

2.5

0.09

8

F

F

1 2

1 2 3 4

F

F F

F

F

F

(1) (2)

mmin.

mmin.

9 ~ 110.35 ~ 0.43

2.5

0.09

8

F

F

1 2

1 2 3 4

F

F F

F

F

F

(1) (2)

mmin.

mmin.

9 ~ 110.35 ~ 0.43

2.5

0.09

8

F

F

1 2

1 2 3 4

F

F F

F

F

F

(1) (2)

mmin.

mmin.

9 ~ 110.35 ~ 0.43

2.5

0.09

8

F

F

1 2

1 2 3 4

F

F F

F

F

F

(1) (2)

mmin.

mmin.

9 ~ 110.35 ~ 0.43

2.5

0.09

8

F

F

1 2

1 2 3 4

F

F F

F

F

F

1 Wiring (cable) terminal opening2 Removal tool opening

12

35.51.40mm

in.29.51.16

23.50.93

311.2222

0.877.5

0.30

94 3.70 90 3.

54

15 0.59

28 1.10

48 1.89

1.2

0.05

Zelio™ Plug-In RelaysRXM miniature relays

Wiring instructions for RXZE2S114S socket

Introduction:page 2

Specifications page 4

References:page 6

Dimensions:page 9

Wiring:page 12

Page 14: RXM miniature relays

The information and dimensions in this catalog are provided for the convenience of our customers. While this information is believed to be accurate, Schneider Electric reserves the right to make updates and changes without prior notification and assumes no liability for any errors or omissions.

Zelio, Schneider Electric and logo, and “Make the most of your energy” are trademarks or registered trademarks of Schneider Electric or its affiliates in the United States and other countries. Other trademarks used herein are the property of their respective owners.

Design: Schneider ElectricPhotos: Schneider Electric

© 2013–2014 Schneider Electric. All rights reserved. 5/20148501DB1301

www.schneider-electric.comSchneider Electric USA, Inc.8001 Knightdale Blvd. Knightdale, NC 27545

USA Customer Care CenterTel: 888-778-2733

Schneider Electric Canada5985 McLaughlin Rd.Missassauga, Ontario, Canada L5R 1B8

Canada Customer Care CenterTel: 800-565-6699