7/23/2019 Ruvolum70 Manual en 03 080729 http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 1/35  Manual for the software to dimension the TECCO ®  slope stabilization system © Geobrugg AG Protection Systems CH - 8590 Romanshorn, Switzerland July 2008 – E03/DF TECCO ® The slope stabilization system This manual describes the most fundamental functions of the dimensioning program. Please read these operating instructions prior to installation and before you use the program for the first time. Keep this reference book close at hand at all times. RUVOLUM ®  7.0

Ruvolum70 Manual en 03 080729

  • Upload
    gparrat

  • View
    215

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 1/35

 

Manual for the software

to dimension the TECCO® 

slope stabilization system

© Geobrugg AGProtection SystemsCH - 8590 Romanshorn, Switzerland

July 2008 – E03/DF

TECCO®

The slope stabilization system

This manual describes the most fundamental functions of the dimensioning program.Please read these operating instructions prior to installation and before you usethe program for the first time. Keep this reference book close at hand at all times.

RUVOLUM® 7.0

Page 2: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 2/35

 

Page 3: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 3/35

RUVOLUM® 7.0 page 1 / 33

PREFACE

Geobrugg AG, Protection Systems, is grateful to you for using the RUVOLUM® 7.0 software. Every effort

is made to give you the best possible support in the dimensioning of the TECCO® slope stabilization sys-

tem.

RUVOLUM® 7.0 offers the possibility of considering streaming pressure and accelerations due to earth-

quake in horizontal as well as in vertical direction. The calculations can be done on the basis of Interna-

tional as well as American Units in English, German, French, Italian, Spanish, Portuguese, Rumanian and

Polish.

This manual provides you with the most important references and function descriptions to enable you to

use the program correctly. The aim has been to develop a program which, despite its complexity of struc-ture and application, is as clear and straightforward as possible as far as aspects of graphic presentation

and user-friendliness are concerned.

Numerous parameters need to be entered for the dimensioning operations. It is the responsibility of the

user of this program to select and enter these parameters correctly.

Sincere thanks are expressed to Ana María Brisbé York who, in close cooperation with Geobrugg AG,

Protection Systems, has developed the software in a competent and professional manner.

Geobrugg AG, Protection Systems

Daniel Flum

July 2008

Page 4: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 4/35

RUVOLUM® 7.0 page 2 / 33

PRODUCT LIABILITY CLAUSE OF

GEOBRUGG AG, PROTECTION SYSTEMS

Rockfall, landslides, debris flows or avalanches are sporadic and unpredictable. Causes can be e.g. hu-

man (construction, etc.) or environmental (weather, earthquakes, etc.). Due to the multiplicity of factors

affecting such events it is not and cannot be an exact science that guarantees the safety of individuals

and property.

However, by the application of sound engineering principles to a predictable range of parameters and by

the implementation of correctly designed protection measures in identified risk areas the risks of injury

and loss of property can be reduced substantially.

Inspection and maintenance of such systems are an absolute requirement to ensure the desired protec-tion level. The system safety can also be impaired by events such as natural disasters, inadequate di-

mensioning parameters or failure to use the prescribed standard components, systems and original parts;

and/or corrosion (caused by pollution of the environment or other man-made factors as well as other ex-

ternal influences).

Page 5: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 5/35

RUVOLUM® 7.0 page 3 / 33

TABLE OF CONTENTS

1. INTRODUCTION................................................................................................................................... 4

2. PURPOSE OF THE SLOPE STABILIZATION SYSTEM...................................................................... 5

3. FUNDAMENTALS................................................................................................................................. 6

4. ELEMENTS OF THE SLOPE STABILIZATION SYSTEM.................................................................... 7

5. INSTALLATION OF THE PROGRAM................................................................................................... 8

6. OPENING THE PROGRAM................................................................................................................ 12

7. START PAGE...................................................................................................................................... 13

8. STRUCTURE OF THE PROGRAM.................................................................................................... 14

9. TAB PROJECT.................................................................................................................................... 15

10. TAB INPUT QUANTITIES................................................................................................................... 20

11. TAB ELEMENTS OF THE SYSTEM................................................................................................... 27

12. TAB PROOFS OF BEARING SAFETY............................................................................................... 31

Page 6: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 6/35

RUVOLUM® 7.0 page 4 / 33

1. INTRODUCTION

The software RUVOLUM® 7.0 serves to dimension the TECCO® slope stabilization system consisting of

the high-tensile steel wire mesh TECCO® G65 / 3 mm with a wire diameter of 3.0 mm and an incircle

diameter of the mesh of 65 mm, system spike plates and adequate nailing.

The software is based on the homonymous RUVOLUM® concept. This concept is basically applicable to

all slope stabilization systems which are commonly available on the market and which allow for a flexible

application of the nails both horizontally and in the slope's fall-line.

The RUVOLUM®  concept investigates both simple wedge-shaped and composite mechanisms liable to

break out from the area close to the surface between the individual nails down to a depth of approxi-

mately 1.5 to 2.0 m maximum. It can be applied to soil slopes as well as superficially and heavily disinte-

grated, loosened or weathered rock slopes.

If, depending on the prevailing geological circumstances, potential sliding surfaces exist at deeper levels,

the overall stability of the slope must be analyzed in addition to the investigation of the instabilities close

to the surface, and the protection measures must be dimensioned accordingly.

In-depth information about the dimensioning concept (model approach, sliding mechanisms, equilibrium

relationships and equations) and about the application of flexible slope stabilization systems in soil as well

as strongly weathered, loosened rock slopes is provided in the Summary of Published Technical Papers

in the Period of 1998 – 2006 .

Investigation of slope-parallel instabilities

near the surface in the RUVOLUM ®  concept

Investigation of local, simple, wedge-shaped

as well as composite instabilities between the

individual nails in the RUVOLUM ®  concept

Page 7: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 7/35

RUVOLUM® 7.0 page 5 / 33

2. PURPOSE OF THE SLOPE STABILIZATION SYSTEM

The purpose of the TECCO® slope stabilization system is to stabilize instabilities close to the surface and,

depending on the prevailing subsoil circumstances and where applicable, also fault mechanisms with

deeper sliding surfaces. Within the framework of the present explanations the investigations are limited to

the area near the surface.

For the individual proofs of bearing safety it is necessary to determine the maximum stress on the sys-

tem. These stresses are established by the investigation of the equilibriums of simple wedge-shaped as

well as composite faults. By a concept adapted to the case on hand and correct dimensioning it must be

guaranteed that the slope stabilization system is able to absorb the occurring stresses and that, with the

appropriate safety factors taken into account; it can pass them on to the stable subsoil outside the insta-

bility under examination.

If the slope stabilization system is planned as a permanent solution (which is normally the case), it must

be guaranteed that the system can absorb the determined maximum stresses during the construction's

entire life span. Reference is made in the technical literature on the TECCO® system concerning protec-

tion against corrosion.

If the subsoil is prone to weathering, additional measures may have to be taken to oppose further loosen-

ing and erosion. One possible measure is to cover the surface with an erosion protection mat before the

steel wire mesh is laid out and to suitably green the protected slope after completion of the installation

work.

Page 8: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 8/35

RUVOLUM® 7.0 page 6 / 33

3. FUNDAMENTALS

The TECCO® slope stabilization system is a flexible system with a static function. Corresponding defor-

mations of the subsoil are required before the system can display its maximum stabilizing effect. This

must be kept in mind especially in the case of constructions which do not allow any or only a minor de-

formation such as e.g. in the area of the road edge on the downslope side. Under certain circumstances

additional measures with a stiffening effect may be required, for example a concrete bar in combination

with infiltration dowelling.

With the TECCO® slope stabilization system each row of nails must be offset by half a horizontal distance

between nails in relation to the next row. In this way the maximum possible bodies liable to break out

between the individual nails are clearly defined. This forms the basis for the RUVOLUM®  concept. The

horizontal distance between nails is denoted by parameter 'a' and the one in the direction of fall by 'b'.

With older protection systems the type of nail arrangement was often influenced by the actual type of

mesh or rope net cover. The nails were usually positioned in a checkered pattern.

The concept underlying the TECCO® system is such that the system can be tensioned actively with a

certain force V against the subsoil to be stabilized. This is affected by tightening of the nuts with the aid of

a torque spanner or by means of a suitable feed press, i.e. by pressing the spike plates firmly onto or

slightly into the ground. Optimal tensioning of the slope stabilizing system can be achieved if the area

around the nail head is slightly recessed. If the mortar reaches too far up the nail, with the result that the

system cannot be tensioned at all or only insufficiently, it must be chipped away to the appropriate level

right around the nail. In the RUVOLUM® concept the force V is taken into account in the investigation of

slope-parallel instabilities as an outer force with a stabilizing effect, and can be selected variably.

For further application-technical information reference is made here to the system manual of the TECCO® 

system.

Page 9: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 9/35

RUVOLUM® 7.0 page 7 / 33

4. ELEMENTS OF THE SLOPE STABILIZATION SYSTEM

The TECCO® slope stabilization system consists of the high-tensile steel wire mesh TECCO® G65 / 3

mm, the TECCO® system spike plate and a corresponding nailing. While the first two elements are given,

different possibilities exist for the choice of the nail type.

The high-tensile steel wire mesh TECCO ® 

 G65 / 3 mm

Mesh size: x · y = 83 · 143 mm = 3.27 · 5.63 in (+/- 3%)

Incircle diameter of the mesh: Di = 65 mm = 2.56 in (+/- 3%)

Wire diameter: d = 3.0 mm = 0.118 in

Tensile strength of the steel wire: f y ≥ 1'770 N/mm

2  = 256 ksi

Tensile strength of the mesh: zm = 150 kN/m = 10.2 kips/ft

Bearing resistance of the mesh against puncturing: DR = 180 kN = 40.4 kips

B. resist. of the mesh against shearing-off at the spike plate: PR = 90 kN = 20.2 kips

B. resist. of the mesh against slope-parallel tensile stress: ZR = 30 kN = 6.7 kips

The TECCO ® 

 system spike plate

Basic shape: diamond-shaped

Length: 330 mm = 13.00 in

Width: 190 mm = 7.49 inThickness: 10 mm = 0.39 in

Hole diameter: 40 mm (+/- 2 mm) = 1.58 in (+/- 0.80 in)

Two lengthwise bridges in the spike plate serve to increase the plate's bending resistance and to guide

the optional boundary ropes. Ball-type nuts should be used to secure the spike plates.

Soil or rock nails

The following nail types can be used as soil or rock nails:

•  GEWI D = 25 mm, DYWIDAG D = 25 mm (Grade 75)

•  GEWI D = 28 mm, DYWIDAG D = 28 mm (Grade 75)

•  GEWI D = 32 mm, DYWIDAG D = 32 mm (Grade 75)

•  TITAN 30/11

•  IBO R32S, IBO R32N

 Alternatively, other nail types can be used if suited. In principle each nail must satisfy the static proofs.

 Additionally, the nail diameter and the corresponding (ball) nut must be matched to the hole diameter of

the system spike plate. A suitable corrosion protection must be envisaged for the nail as a permanent

measure, unless rusting away of usually 4.0 mm (= 0.158 in) with reference to the nail's diameter is taken

into account.

Page 10: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 10/35

RUVOLUM® 7.0 page 8 / 33

5. INSTALLATION OF THE PROGRAM

The software RUVOLUM® 7.0 will be installed on your computer with the aid of an installation assistant

which can be called by double-clicking the ‘setup.exe’ file on the inserted CD-R. The installation is in eng-

lish. Next to the ‘setup.exe’ file, the software manual can be found on the CD-R as a pdf as well.

In the first window you are welcomed by the installation assistant. Click 'Next' to continue. In the second

window the target address needs to be stated for the installation of the RUVOLUM® program. In case of

not altering the target address using the ‘Change’ button, the program will be installed in C:\Program

Files\RUVOLUM 7.0\ as proposed. The assistant also arranges for a link from the RUVOLUM® program

to the desktop.

Page 11: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 11/35

RUVOLUM® 7.0 page 9 / 33

In the third window the installation assistant informs you that it is ready for the installation. By clicking

‘Install’ you start the installation of the RUVOLUM® program on your computer. The fifth and last window

confirms that the program has been installed successfully.

Page 12: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 12/35

RUVOLUM® 7.0 page 10 / 33

If the software RUVOLUM®  7.0 is already installed and you place the CD-R in the corresponding disk

drive and if you would like to install the software by double-clicking the ‘setup.exe’ file, the installation

assistant welcomes you again. After clicking ‘Next’, the assistant offers you the possibility to choose be-

tween ‘Modify’, ‘Repair’ and ‘Remove’.

In this case, it is generelly recommended to quit the program by clicking ‘Cancel’ then. In case of choos-

ing ‘Modify’ or ‘Repair’, respectively, it cannot be guaranteed that all existing project data can be called

after properly again.

If you would like to remove the software RUVOLUM® 7.0 from you computer, it is recommended not to

use the function ‘Remove’ therefore. Instead, the program should be removed via ‘Software’ in the Con-

trol Panel.

Page 13: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 13/35

RUVOLUM® 7.0 page 11 / 33

Documents in the file C:\Program Files\RUVOLUM 7.0\:

•  DATOS

  datos.CDX

  datos.dbf

  newnails.CDX

  newnails.dbf

  preferen.dbf

  projecto.CDX

  projecto.dbf

•  SYS

  LenguaAL.CDX

  lenguaal.DBF

  LenguaBR.CDX

  lenguabr.DBF

  LenguaEN.CDX

  lenguaen.DBF  LenguaES.CDX

  lenguaes.DBF

  LenguaFR.CDX

  lenguafr.DBF

  LenguaIT.CDX

  lenguait.DBF

  LenguaPL.CDX

  lenguapl.DBF

  LenguaPO.CDX  lenguapo.DBF

  LenguaRM.CDX

  lenguarm.DBF

•  msvcr71.dll

•  ReportBuilder.app

•  ReportOutput.app

•  ReportPreview.app

•  RUVOLUM 7.0.exe

Page 14: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 14/35

RUVOLUM® 7.0 page 12 / 33

6. OPENING THE PROGRAM

In principle there are two possibilities of starting the dimensioning program:

1. After installation, a link to the program in file C:\Program Files\RUVOLUM 7.0\ was established on

your desktop. You can start the RUVOLUM® program by double-clicking this link.

2. The program can also be started by double-clicking the file 'RUVOLUM 7.0.exe' in C:\ProgramFiles\RUVOLUM 7.0\.

Page 15: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 15/35

RUVOLUM® 7.0 page 13 / 33

7. START PAGE

The start page of the program contains information on the version, the application area and the compa-

nies involved in the development of the program. RUVOLUM® 7.0 offers the possibility of considering

streaming pressure and accelerations due to earthquake in horizontal as well as vertical direction. The

calculation can be done on the basis of International as well as American Units in English, German,

French, Italian, Spanish, Portuguese, Rumanian and Polish.

 Any time language or unit are changed, they are defined as standard.

The start page is only displayed after opening of the program.

By clicking 'Start' you reach the dimensioning program.

By clicking 'Exit' you can quit the dimensioning program.

Page 16: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 16/35

RUVOLUM® 7.0 page 14 / 33

8. STRUCTURE OF THE PROGRAM

The dimensioning program has four tabs:

1. Project

2. Input quantities

3. Elements of the system

4. Proofs of bearing safety

General information on the project is compiled in the first tab 'Project'. The second tab 'Input quantities'

permits selection of various parameters and the stabilization system can be dimensioned. The character-

istics and bearing resistances of the elements are compiled in the third tab 'Elements of the system',

where the possibility exists of altering the specifications of the nail types, defining new nail types and de-

leting types that are no longer required. In the last tab 'Proofs of bearing safety' details of the total of five

proofs of bearing safety can be viewed. By this means the dimensioning values of the determined maxi-

mum stresses are compared with the dimensioning values of the bearing resistances.

Page 17: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 17/35

RUVOLUM® 7.0 page 15 / 33

9. TAB PROJECT

When the dimensioning program is opened, the project and project number that were entered last are

displayed, including details on the place, special designation of the location, information on the project

and maybe also the date of doing the calculation as well as the user.

The list underneath shows a summary of the calculations made under the project in question plus the

most important parameters including nail types used. The meaning of the individual parameters is ex-

plained in the next chapter.

It is possible to change from the currently displayed project to the next or the previous one, to define a

new one, to display an overview of the individual projects, to delete calculations as well as projects and to

show the outputs or to print those out.

Printing of result sheets

Preview of result sheets

Delete a calculation, a project

Overview of projects

New project

Back to previous project

Go to next project

Page 18: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 18/35

RUVOLUM® 7.0 page 16 / 33

The very fist time, you will enter the program, the cells are deactivated. To establish the first project, the

button ‘New project’ needs to be selected. Depending on the unit activated on the start page, the new

project will be based on International or American units.

If International units were chosen when creating a new project the first time, these will be the default units

the next time the program is entered. If American units were chosen, then any new projects will display

 American units.

Once units are established in an existing project they cannot be changed afterwards anymore. To enter a

new project based on different units, you need to restart the program, to change the units and to select

then ‘New project’.

Page 19: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 19/35

RUVOLUM® 7.0 page 17 / 33

The RUVOLUM® 7.0 version has the capability to print out several calculations at once. To do this, the

corresponding boxes need to be activated by ticking. Furthermore, appendix numbers can be introduced

as well.

Page 20: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 20/35

RUVOLUM® 7.0 page 18 / 33

If a project consists of numerous calculations and if a specific calculation needs to be altered, there is an

elegant way to show the corresponding input quantities by double-clicking the number of the specific cal-

culation in the chart in the project sheet.

Deletion of a calculation / a project

If specific calculations should be deleted, the individual calculations need to be activated by ticking first

before clicking the command ‘Delete a calculation, a project’. In case of activating all calculations, the

whole project will be irreparably deleted. In this case the display will show the previous project.

Page 21: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 21/35

RUVOLUM® 7.0 page 19 / 33

Overview of individual projects

The overview shows all projects from top to bottom in the order of the dates on which they were last ed-

ited. To be able to process a certain project or to view its calculations you can double-click the line inquestion. The overview is then closed and the desired project is retrieved.

By double-clicking the grey bar above the column marked 'Project No.' it is possible to alter the order of

the project numbers from ascending (bottom to top) to descending. By double-clicking the bar above the

column with the locations it is possible to sort the projects alphabetically.

Page 22: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 22/35

RUVOLUM® 7.0 page 20 / 33

10. TAB INPUT QUANTITIES

Tab 'Input quantities' is the central tab for  dimensioning of the TECCO® slope stabilization system. It in-

cludes all geometrical and geotechnical parameters as well as load cases. By the introduction of partial

safety factors it is possible to dimension the system in line with the partial safety concept. If the system is

to be dimensioned in the traditional manner according to the global safety concept, all partial safeties can

be put equal 1.00. In this case the model uncertainty correction factor corresponds to the global safety.

With the aid of the drop-down lists the horizontal distance between nails can be selected independent of

the distance between nails in the fall-line, or identical to it. The nail type, moreover, can be defined with-

out or with rusting away taken into account. Furthermore, the load cases “Earthquake” considering hori-

zontal and vertical accelerations as well as “Streaming pressure” can be taken into account.

Masked-in in the head area are the project number, the number of the current calculation and the total

number of calculations. The following buttons are arranged on the side:

Printing of result sheets

Preview of result sheets

New calculation

Back to previous calculation

Go to next calculation

Page 23: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 23/35

RUVOLUM® 7.0 page 21 / 33

Button „New calculation“

If the button 'New calculation' is clicked, all input parameters of the last calculation are taken over. This

enables a very efficient execution of different calculations with e.g. different nail types or different layerthicknesses.

Page 24: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 24/35

RUVOLUM® 7.0 page 22 / 33

Button ‘Result sheets 1 and 2’ 

By activating this button a new window is displayed with the result sheets (as known from the preview in

the project tap, but for one calculation only). The first sheet summarizes the input quantities, load casesand system elements and provides an overview of the established proofs of bearing safety. The second

result sheet presents all proofs of bearing safety in a detailed manner.

Saving the individual calculations

The program saves every change and adaptation continuously. This is why suitable care must be exer-

cised when calling up older calculations. Changes must be made in a controlled manner and consciously.

They are irrevocable.

It is recommended to regularly carry out backups of the folder C:\Program Files\RUVOLUM 7.0 for safety

reasons.

Page 25: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 25/35

RUVOLUM® 7.0 page 23 / 33

Ranges of values of the input quantities in International Units

The chart below shows an overview of the minimum, maximum and default values as well as of the in-

crements in International Units. The default values are called up when a new project and thereby auto-matically a new calculation is established.

Input quantity parameter min. max. default increment 

Slope inclination α [degrees] 0.0 90.0 60.0 1.0

Nail distance horizontal a [m] 1.00 5.00 2.70 0.05

Nail distance in line of slope b [m] 1.00 5.00 2.70 0.05

Layer thickness t [m] 0.00 5.00 1.00 0.05

Radius of pressure cone, top ζ [m] 0.00 1.00 0.15 0.05

Inclination of pressure cone to horizontal δ [degrees] 30.0 90.0 45.0 1.0

Friction angle ground (charact. value)  ϕk [degrees] 0.0 60.0 32.0 0.5

Cohesion ground (characteristic value) ck [kN/m2] 0.0 50.0 0.0 1.0

Volume weight ground (charact. value) γk [kN/m3] 0.0 30.0 20.0 0.5

Slope-parallel force Zd [kN] 0.0 20.0 15.0 5.0

Pretensioning force of the system V [kN] 0.0 50.0 30.0 10.0

Nail inclination to horizontal Ψ [degrees] 0.0 90.0 20.0 5.0

Partial safety corr. value for friction angle γϕ [-] 1.00 2.00 1.25 0.05

Partial safety correction value for cohesion γc [-] 1.00 2.00 1.50 0.05

Partial safety corr. value for volume weight γγ [-] 1.00 2.00 1.00 0.05

Model uncertainty correction value γmod [-] 1.00 2.00 1.10 0.05

Coeffic. of vertical accel. due to earthquake εv [-] 0.000 1.000 0.000 0.005

Coeffic. of horiz. accel. due to earthquake εh [-] 0.000 1.000 0.000 0.005

It is recommended to alter the input quantities by means of the arrow keys as a matter of principle. How-

ever, the possibility exists also to adapt the values by marking them with the mouse and overwriting them.

IMPORTANT !!

Each entry or alteration must be confirmed with ENTER or with a mouse click in an empty area

to execute all required calculations and to update the results.

Page 26: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 26/35

RUVOLUM® 7.0 page 24 / 33

Ranges of values of the input quantities in American Units

The chart below shows an overview of the minimum, maximum and default values as well as of the in-

crements in American Units. The default values are called up when a new project and thereby automati-cally a new calculation is established.

Input quantity parameter min. max. default increment 

Slope inclination α [degrees] 0.0 90.0 60.0 1.0

Nail distance horizontal a [ft] 3.00 16.00 9.00 ¼

Nail distance in line of slope b [ft] 3.00 16.00 9.00 ¼

Layer thickness t [ft] 0.00 16.00 3.00 ¼

Radius of pressure cone, top ζ [in] 0.00 40.00 6.0 1.0

Inclination of pressure cone to horizontal δ [degrees] 30.0 90.0 45.0 1.0

Friction angle ground (charact. value)  ϕk [degrees] 0.0 60.0 32.0 0.5

Cohesion ground (characteristic value) ck [lbs/ft2] 0.0 1000.0 0.0 10.0

Volume weight ground (charact. value) γk [lbs/ft3] 0.0 200.0 130.0 5.0

Slope-parallel force Zd [kips] 0.0 4.4 3.3 1.1

Pretensioning force of the system V [kips] 0.0 11.0 7.0 1.0

Nail inclination to horizontal Ψ [degrees] 0.0 90.0 20.0 5.0

Partial safety corr. value for friction angle γϕ [-] 1.00 2.00 1.25 0.05

Partial safety correction value for cohesion γc [-] 1.00 2.00 1.50 0.05

Partial safety corr. value for volume weight γγ [-] 1.00 2.00 1.00 0.05

Model uncertainty correction value γmod [-] 1.00 2.00 1.10 0.05

Coeffic. of vertical accel. due to earthquake εv [-] 0.000 1.000 0.000 0.005

Coeffic. of horiz. accel. due to earthquake εh [-] 0.000 1.000 0.000 0.005

It is recommended to alter the input quantities by means of the arrow keys as a matter of principle. How-

ever, the possibility exists also to adapt the values by marking them with the mouse and overwriting them.

IMPORTANT !!

Each entry or alteration must be confirmed with ENTER or with a mouse click in an empty area

to execute all required calculations and to update the results.

Page 27: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 27/35

RUVOLUM® 7.0 page 25 / 33

Conversions

The following conversions are taken into account.

 American – International Units International – American Units

1 ft 0.3048 m 1 m 3.281 ft

1 in 25.4 mm 1 mm 0.0394 in

1 in2  645.2 mm

2  1 mm

2  0.00155  in

1 lb(s) 0.4536 kg 1 kg 2.20462 lbs

1 lb(s) 4.4482 N 1 N 0.22481 lbs

1 lb(s) 0.0044482 kN 1 kN 224.81 lbs

1 kip(s) 4.4482 kN 1 kN 0.22481 kips

1 lbs/ft 1.4882 kg/m 1 kg/m 0.6719 lbs/ft1 lbs/ft 0.0149 kN/m 1 kN/m 68.519 lbs/ft

1 lbs/ft2  0.0479 kN/m

2  1 kN/m

2  20.88 lbs/ft

1 lbs/ft3  0.1571 kN/m

3  1 kN/m

3  6.365 lbs/ft

1 ksi 6.895 N/mm2  1 N/mm

2  0.145 ksi

Dimensioning values of the geotechnical parameters

In the standard mode the TECCO®

 slope stabilization system is dimensioned in line with the partial safetyconcept. Hereby the characteristic values of the ground are transformed into dimensioning values accord-

ing to the relationships listed below, whereby the corresponding partial safety correction values are taken

into account:

ϕd  = arctan ( tan ϕk / γϕ )

cd  = ck / γc

γd  = γk · γγ 

ϕk  = characteristic value of the friction angle

ck  = characteristic value of the cohesion

γk  = characteristic value of the volume weight

γϕ  = partial safety correction value for friction angle

γc  = partial safety correction value for cohesion

γγ  = partial safety correction value for volume weight

ϕd  = dimensioning value of the friction angle

cd  = dimensioning value of the cohesion

γd  = dimensioning value of the volume weight

Page 28: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 28/35

RUVOLUM® 7.0 page 26 / 33

Overview of the results of the proofs of bearing safety

On the basis of the selected input quantities, if at least one proof of bearing safety is not established, a

corresponding message will display.

The input quantities must be selected in such a manner that all proofs of bearing safety concerning both

the nail and the mesh are established.

Page 29: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 29/35

RUVOLUM® 7.0 page 27 / 33

11. TAB ELEMENTS OF THE SYSTEM

The third tab displays an overview of the bearing resistances of the individual system elements in Interna-

tional or American Units. Seeing that this program serves for the dimensioning of the TECCO® slope sta-

bilization system, the types of applied mesh and of the spike plate inclusive of the corresponding bearing

resistances are given.

The bottom part shows a summary of the bearing resistances and the cross-section surface of the applied

nail type. Moreover, it is stated whether or not any rusting away of the nail is considered. If rusting away

is taken into account, the nail diameter is in standard mode reduced by 4.0 mm (0.158 in) for the determi-

nation of the bearing resistances.

 Analogously to tab 'Input quantities', the head section of tab 'Elements of the system' shows the projectnumber, the number of the current calculation and the total number of calculations.

For the program user's freedom in the selection and specification of nail types, the possibility is provided

in button 'Nail types' to alter existing nail types, to delete them or to define new ones.

The next two windows display after activation of button 'Nail types' once with International and once with

 American Units. The values stated are based on information provided by the manufacturer.

There are basically two charts. In the top chart with the white background the names of the nail types and

the values can be altered. The values in the bottom chart with the grey background are calculated from

the applicable relationships.

Page 30: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 30/35

RUVOLUM® 7.0 page 28 / 33

Page 31: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 31/35

RUVOLUM® 7.0 page 29 / 33

To alter the specifications of an existing nail type it is possible to overwrite the values. To define a new,

additional nail type, a new line can be inserted by clicking button .

The following lines must be filled in under all circumstances when altering an existing nail type and alsowhen defining a new one: nail type, the external diameter DE, the internal diameter DI if ≠ 0, rusting away

∆ and the yielding point f y. The tensile strength f t and the nail's weight G per running meter or per foot,

respectively, are only informative and do not necessarily have to be stated. If a cell is empty, this corre-

sponds to the value 0.

To delete an existing nail type, place the cursor anywhere on the corresponding line and click button .

 A window is then displayed asking whether or not this nail type should really be deleted.

In the second column there is the possibility of activating the corresponding nail type by ticking it, or to

deactivate it by removing the tick. Activated means that this nail type is shown in the drop-down list in tab

'Input quantities'. If a nail type is not active, it does not appear in the drop-down list either.

.

Page 32: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 32/35

RUVOLUM® 7.0 page 30 / 33

If a nail type used in an older calculation is deactivated or has even been deleted and this particular older

calculation is retrieved, an empty field is displayed in the drop-down list. The old nail type still exists in the

background memory. If, for example, the slope inclination or the ground's friction angle are altered and no

new nail type is selected, the proofs of bearing safety continue to be established with the old nail type.The name of the old nail type continues to be shown in the overview chart of tab 'Project'. It is only after

selection of a new nail type by means of the drop-down list that the proofs are established with the bear-

ing resistances of this new type.

Page 33: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 33/35

RUVOLUM® 7.0 page 31 / 33

12. TAB PROOFS OF BEARING SAFETY

Compiled in the last tab are the individual proofs of bearing safety concerning the investigation of local

instabilities between the individual nails as well as the investigation concerning slope-parallel instabilities

near the surface. The displays in red color next to the buttons inform you whether or not the individual

proofs of bearing safety are established.

 Analogously to the tabs 'Input quantities' and 'Elements of the system', the head section again shows the

project number, the number of the current calculation as well as the total number of calculations.

Page 34: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 34/35

RUVOLUM® 7.0 page 32 / 33

The two windows below show the proofs of bearing safety concerning the investigation of local instabili-

ties between the nails.

The next three windows show the proofs of bearing safety concerning the investigation of slope-parallel

instabilities close to the surface.

Page 35: Ruvolum70 Manual en 03 080729

7/23/2019 Ruvolum70 Manual en 03 080729

http://slidepdf.com/reader/full/ruvolum70-manual-en-03-080729 35/35