36
Drawing nr. Contents of drawing SPBC01-1E-EN Plinth, horizontal installation SPBC01-2E-EN Plinth, horizontal installation SPBC01-3E-EN Plinth, horizontal installation SPBC01-4E-EN Plinth, horizontal installation SPBC01-5E-EN Plinth, vertical and diagonal installation SPBC01-6E-EN Plinth, detail SPBC01-7E-EN Plinth, detail SPBC01-8E-EN Plinth, detail SPBC02-1E-EN Joint between panels, horizontal installation SPBC02-2E-EN Joint between panels, vertical and diagonal installation SPBC02-3E-EN Joint between panels, horizontal, vertical and diagonal installation SPBC03-1E-EN Vertical joint, horizontal inst., rectangle steel column, option 1 SPBC03-2E-EN Vertical joint, horizontal inst., rectangle steel column, option 2 SPBC04-1E-EN External corner, horizontal inst., rectangle steel column, option 1 SPBC04-2E-EN External corner, horizontal inst., rectangle steel column, option 2 SPBC05-1E-EN Internal corner, horizontal inst., rectangle steel column SPBC06-1E-EN Parapet, horizontal installation, side eaves SPBC06-2E-EN Parapet, horizontal installation, end eaves SPBC06-3E-EN Parapet, vertical and diagonal inst., side eaves SPBC06-4E-EN Parapet, vertical and diagonal inst., end eaves SPBC06-5E-EN Cantilever eaves, horizontal inst., side eaves, prof. sheet SPBC06-6E-EN Cantilever eaves, horizontal inst., end eaves, prof. sheet SPBC06-7E-EN Vapour barrier and insulation supp. flashing fastening SPBC07-1E-EN Window, horizontal installation SPBC07-2E-EN Window, horizontal installation SPBC07-3E-EN System window, horizontal installation, large window SPBC07-4E-EN System window, horizontal installation, large window SPBC08-1E-EN Door, horizontal installation SPBC08-2E-EN Door, horizontal installation SPBC08-3E-EN Overhead door, horizontal installation SPBC08-4E-EN Overhead door, horizontal installation SPAC09-1E-EN Horizontal joint between panels, vertical inst. rectangle steel beam, option 1 SPAC09-2E-EN Horizontal joint between panels, vertical inst. concrete slab, option 2 SPAC09-3E-EN Horizontal joint between panels, vertical inst. concrete slab, option 3 City sector Building type Block Site/Reg. nr. File nr. Drawing type Contents of drawing Scale Building, Name and address Date Drawn by Designer Checked Work nr. Work nr. Drw. nr. Rev. Nr. Ruukki Poland Ltd St. Łukowska 7/9 64-600 OBORNIKI POLAND www.ruukki.com Ruukki ® Patina Panel Ruukki 17.05.2021 BASE DETAIL DRAWINGS External walls (34 pcs)

Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Drawing nr. Contents of drawing

SPBC01-1E-EN Plinth, horizontal installation

SPBC01-2E-EN Plinth, horizontal installation

SPBC01-3E-EN Plinth, horizontal installation

SPBC01-4E-EN Plinth, horizontal installation

SPBC01-5E-EN Plinth, vertical and diagonal installation

SPBC01-6E-EN Plinth, detail

SPBC01-7E-EN Plinth, detail

SPBC01-8E-EN Plinth, detail

SPBC02-1E-EN Joint between panels, horizontal installation

SPBC02-2E-EN Joint between panels, vertical and diagonal installation

SPBC02-3E-EN Joint between panels, horizontal, vertical and diagonal installation

SPBC03-1E-EN Vertical joint, horizontal inst., rectangle steel column, option 1

SPBC03-2E-EN Vertical joint, horizontal inst., rectangle steel column, option 2

SPBC04-1E-EN External corner, horizontal inst., rectangle steel column, option 1

SPBC04-2E-EN External corner, horizontal inst., rectangle steel column, option 2

SPBC05-1E-EN Internal corner, horizontal inst., rectangle steel column

SPBC06-1E-EN Parapet, horizontal installation, side eaves

SPBC06-2E-EN Parapet, horizontal installation, end eaves

SPBC06-3E-EN Parapet, vertical and diagonal inst., side eaves

SPBC06-4E-EN Parapet, vertical and diagonal inst., end eaves

SPBC06-5E-EN Cantilever eaves, horizontal inst., side eaves, prof. sheet

SPBC06-6E-EN Cantilever eaves, horizontal inst., end eaves, prof. sheet

SPBC06-7E-EN Vapour barrier and insulation supp. flashing fastening

SPBC07-1E-EN Window, horizontal installation

SPBC07-2E-EN Window, horizontal installation

SPBC07-3E-EN System window, horizontal installation, large window

SPBC07-4E-EN System window, horizontal installation, large window

SPBC08-1E-EN Door, horizontal installation

SPBC08-2E-EN Door, horizontal installation

SPBC08-3E-EN Overhead door, horizontal installation

SPBC08-4E-EN Overhead door, horizontal installation

SPAC09-1E-EN Horizontal joint between panels, vertical inst. rectangle steel beam, option 1

SPAC09-2E-EN Horizontal joint between panels, vertical inst. concrete slab, option 2

SPAC09-3E-EN Horizontal joint between panels, vertical inst. concrete slab, option 3

City sector

Building type

Block Site/Reg. nr. File nr.

Drawing type

Contents of drawing ScaleBuilding, Name and address

Date

Drawn by

Designer

Checked

Work nr. Work nr. Drw. nr. Rev.

Nr.

Ruukki Poland Ltd

St. Łukowska 7/9

64-600 OBORNIKI

POLAND www.ruukki.com

Ruukki ® Patina Panel

Ruukki

17.05.2021

BASE DETAIL DRAWINGS

External walls (34 pcs)

Page 2: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

SANDWICH PANELS

001. Ruukki ® Patina Panel 150, 160, 170, 180, 200, 230

FLASHINGS

100-103. Standard purlins and starter tracks

104-109. Purlins and other t ≥ 2 mm fastening flashings

111-119. Plinth flashings

131-159. Vertical seam-, external- and internal corner

flashings

161-179. Eave flashings

181-194. Window- and door flashings

195-199. Flashings used in uplifted roofs

FASTENERS

201. Self-drilling element screw, washer with sealing,

stainless steel

202. Self-drilling element screw, without washer,

stainless steel

215. Countersink washer

231. Flashing fastener, washer with sealing,

stainless steel

232. Flashing fastener, without washer, stainless steel

234. Flat headed flashing fastener for concrete

242. Fastener screw, without washer, stainless steel

243. Fastener screw, without washer, stainless steel

255. Spike fastener, without washer

265. Fastener screw to wood, washer with sealing,

stainless steel

270. Installation sleeve

SEALANTS AND INSULATIONS

300. Expandable sealing band

301. Plinth sealing expanding

302. Sealing tape for flashings

303. Sealing tape for frame

306. ISO-BUTYL self adhesive tape 2x10mm

307. Sealing strip Nordic

308. Self adhesive butylband

309. Sealing strip corner Nordic

310. Mineral wool

311. Mineral wool

312. Mineral wool batten

321. Sealing compound

325.Sealing compound during installation

327. Elastic polyurethane, eg. Illbruck FM330

330. PU insulation

331. EPDM sealing

332. Separating piece EPDM

333. Separating strip EPDM

341. Plywood

342. L-profile

350. PVC tape

351. Rubber o-ring sealing

352. Lead-in rubber grommet

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC00-0E-EN

Ruukki

17.05.2021

Accessory numbers in details

Ruukki ® Patina Panel

Page 3: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

48

≥ 40

25

- +

111. COR-TEN Plinth flashing (installed simultaneously with elements)

131. COR-TEN Vertical joint flashing

231. Flashing fastener, washer with sealing *

265. /S3H55042WA4B/ Fastener *, wood c/c600

312. Mineral wool batten

341. Plywood, if necessary

Ruukki's delivery

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC01-1E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Option 1

Horizontal installation, plinth, vertical section

Ruukki ® Patina Panel

234

100

312

001

131

265

SPBC01-6E

341

111

001. Ruukki ® Patina Panel

308

350

308. Self adhesive butylband

350. PVC tape

301

231

301. /EA3PSE/ Plinth sealing, expanding (wider sealing on internal side)

Special care should be taken

to ensure the smoothness of the

top of plinth, tolerance ± 5 mm

100. /EA1U___/ Starter track

*Screw material stainless steel

234. Flat head flashing fastener to concrete

or

Page 4: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

≥ 40

25

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC01-2E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Option 2

Horizontal installation, plinth, vertical section

Ruukki ® Patina Panel

100. /EA1U___/ Starter track

265. /S3H55042WA4B/ Fastener *, wood c/c600

306. ISO-BUTYL self adhesive tape 2x10 mm

308. Self adhesive butylband

312. Mineral wool batten

350. PVC tape

Ruukki's delivery

115. Support flashing (installed simultaneously with elements)

131. COR-TEN Vertical joint flashing

001. Ruukki ® Patina Panel

100

312

265

001

131

SPBC01-6E

255

115

111

308

306

350

111. COR-TEN Plinth flashing (installed simultaneously with elements)

301. /EA3PSE/ Plinth sealing, expanding (wider sealing on internal side)

301

Special care should be taken

to ensure the smoothness of the

top of plinth, tolerance ± 5 mm

*Screw material stainless steel

48

234. Flat head flashing fastener to concrete

234

301

or

Page 5: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

48

≥ 40

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC01-3E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Option 3

Horizontal installation, plinth, vertical section

Ruukki ® Patina Panel

312. Mineral wool batten

131. COR-TEN Vertical joint flashing

265. /S3H55042WA4B/ Fastener *, wood c/c600

Ruukki's delivery

231. Flashing fastener, washer with sealing *

25

001. Ruukki ® Patina Panel

001

131

SPBC01-7E

231

116

255

115

306

100

312

332

100. /EA1U___/ Starter track

115. Support flashing (installed simultaneously with elements)

116. COR-TEN Plinth flashing (can be installed after element installation)

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

301. /EA3PSE/ Plinth sealing, expanding (wider sealing on internal side)

265

Special care should be taken

to ensure the smoothness of the

top of plinth, tolerance ± 5 mm

*Screw material stainless steel

234. Flat head flashing fastener to concrete

321

321. /EA3SM312___/ Sealing compound

234

301

or

Page 6: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC01-4E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Option 3

Horizontal installation, plinth, vertical section

Ruukki ® Patina Panel

Ruukki's delivery

48

≥ 40

25

001. Ruukki ® Patina Panel

001

131

SPBC01-7E

116

100

312

333

321

312. Mineral wool batten

131. COR-TEN Vertical joint flashing

265. /S3H55042WA4B/ Fastener *, wood c/c600

301. /EA3PSE/ Plinth sealing, expanding (wider sealing on internal side)

100. /EA1U___/ Starter track

115. Support flashing (installed simultaneously with elements)

116. COR-TEN Plinth flashing (can be installed after element installation)

306. ISO-BUTYL self adhesive tape 2x10 mm

321. /EA3SM312___/ Sealing compound

333. /CA3SE410/ Separating strip EPDM

265

Special care should be taken

to ensure the smoothness of the

top of plinth, tolerance ± 5 mm

*Screw material stainless steel

255

115

306

234. Flat head flashing fastener to concrete

234

301

or

Page 7: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

≥ 3

0

301

234

234

118

326

105

302

234

001

131

SPBC01-8E

326

201

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC01-5E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Plinth, vertical section

vertical and diagonal installation

Ruukki ® Patina Panel

118. Cover flashing, according to project

Ruukki's delivery

201. Self-drilling element screw, washer with sealing *

105. /EA1L75/ Support L-purlin, (t=3mm)

255. /S5R48038/ Spike fastener, concrete c/c600

302. /EA3SS410/ Sealing tape

321. /EA3SM312___/ Sealing compound

326. /EA3SM312___/ Sealing compound during

inst. to outer female groove full length of element

231. Flashing fastener, washer with sealing * and inner female groove 60 mm from panel end

231

116

332

321

≥ 40

001. Ruukki ® Patina Panel

352/332

115. Support flashing (installed with elements)

116. COR-TEN Plinth flashing (can be installed afterwards)

131. COR-TEN Vertical joint flashing

301. /EA3PSE/ Plinth sealing, expanding

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

*Screw material stainless steel

255

115

306

48

234. Flat head flashing fastener to concrete

301

(wider sealing on internal side)

Page 8: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC01-6E-EN

Ruukki

17.05.2021

1:1

Horizontal installation, plinth, detail

Ruukki ® Patina Panel

Special care should be taken to ensure the

smoothness of the top of plinth, tolerance ± 5 mm

Elastic sealing strip,

installed on site

Page 9: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC01-7E-EN

Ruukki

17.05.2021

1:1

Horizontal installation, plinth, detail

Ruukki ® Patina Panel

Special care should be taken to ensure the

smoothness of the top of plinth, tolerance ± 5 mm

Elastic sealing strip,

installed on site

Page 10: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC01-8E-EN

Ruukki

17.05.2021

1:1

Plinth, detail

vertical and diagonal installation

Ruukki ® Patina Panel

Special care should be taken to ensure the

smoothness of the top of plinth, tolerance ± 5 mm

Sealing compound to female groove

during installation

Sealing compound

after installation

Page 11: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC02-1E-EN

Ruukki

17.05.2021

1:2

Vertical section

Horizontal installation, joint between panels,

Ruukki ® Patina Panel

11

00

±2

11

00

±2

Ruukki's delivery

325. /EA3SM312___/ Sealing compound during installation to outer female groove

to length equivalent to vertical joint flashing width and inner female groove in length of sealing

001

325

001

001. Ruukki ® Patina Panel

Elastic sealing strip,

installed in the factory

Protective film

is installed in the factory

Elastic sealing strip,

installed on site

Page 12: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

-

+

326. /EA3SM312___/ Sealing compound during installation to outer female groove in full length of element and

Ruukki's delivery

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC02-2E-EN

Ruukki

17.05.2021

1:2

Joint between panels, horizontal section

and diagonal installation

Ruukki ® Patina Panelvertical-

inner female groove 60 mm from panel end

001

001

1100 ±21100 ±2

001. Ruukki ® Patina Panel

326

Protective film

is installed in the outer groove

joint as a standard in the factory

Elastic sealing strip,

installed in the factory

Elastic sealing strip,

installed on site

Page 13: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC02-2E-EN

Ruukki

17.05.2021

1:1

Joint between panels

horizontal, vertical- and diagonal installation

Ruukki ® Patina Panel

Horizontal installation:

Sealing compound during installation to outer female groove. Length equivalent to width of vertical joint

flashing. It is important that the groove is completely filled with mastic sealant, i.e. it must be applied before

interlocking the joint.

Vertical installation:

Sealing compound during installation to outer female groove in full length of panel and inner female groove

60 mm in length. It is important that the groove is completely filled with mastic sealant, i.e. it must be applied

before interlocking the joint.

Vertical joint flashing

- +

Sealing

Vertical joint flashing

Separating piece EPDM

Sealing compound during installation,

length equivalent to width of vertical joint flashing

-

+

Sealing compound during installation,

length equivalent to width of vertical joint flashing

Protective film is installed in the outer

groove joint as a standard in the factory.

Elastic sealing strip is installed on site.

Page 14: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC03-1E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Vertical joint, horizontal section, option 1

Horizontal installation

Ruukki ® Patina Panel

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

303. /EA3SS1210/ Sealing tape

Ruukki's delivery

325. /EA3SM312___/ Sealing compound during inst.

to outer female groove in length equivalent to

vertical joint flashing width and inner female groove

from panel end to sealing

+

-

001. Ruukki ® Patina Panel

325

325

231

332/333

131

312

307

201

001

321

352/332

131. COR-TEN vertical joint flashing

307. /EA3JSN7525/ Joint sealing Nordic

312. Mineral wool batten

321. /EA3SM312___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

≥ 30

≥ 50

30

303

327

327. Elastic polyurethane foam

*Screw material stainless steel

Page 15: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Ruukki's delivery

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC03-2E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Vertical joint, horizontal section, option 2

Horizontal installation

Ruukki ® Patina Panel

215, requires preholes 27 mm

+

-

001. Ruukki ® Patina Panel

325

312

307

202

001

351

202. Self-drilling element screw, without washer *

231. Flashing fastener, washer with sealing *

215. /EA2W40-910S/ Countersink washer

325. /EA3SM312___/ Sealing compound during inst.

to outer female groove in length equivalent to

vertical joint flashing width and inner female groove

from panel end to sealing

131. COR-TEN vertical joint flashing

307. /EA3JSN7525/ Joint sealing Nordic

312. Mineral wool batten

321. /EA3SM312___/ Sealing compound

325

≥ 30

≥ 50

30

303

327

303. /EA3SS1210/ Sealing tape 332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

351. Rubber o-ring sealing

327. Elastic polyurethane foam

*Screw material stainless steel

231

332/333

131

321

Page 16: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

+

-

b

50

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC04-1E-EN

22.09.2021

Ruukki

17.05.2021

1:2

External corner, horizontal section, option 1

Horizontal installation

Ruukki ® Patina Panel

141. COR-TEN external corner flashing

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

Ruukki's delivery

312. Mineral wool batten

325. /EA3SM312___/ Sealing compound during inst.

to outer female groove in length equivalent to

Facing sheet cutting at site

by length b = element thickness

309. /EA3JSCN30025/ Joint sealing corner Nordic

vertical joint flashing width and inner female groove

from panel end to sealing

231

332/333

201

141

001

312

325

309

001. Ruukki ® Patina Panel

321

352/332

321. /EA3SM312___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

30 ≥ 30

327

303

303. /EA3SS1210/ Sealing tape 327. Elastic polyurethane foam

*Screw material stainless steel

30 ≥ 30

Page 17: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC04-2E-EN

22.09.2021

Ruukki

17.05.2021

1:2

External corner, horizontal section, option 2

Horizontal installation

Ruukki ® Patina Panel

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

Ruukki's delivery

145. /EA1EC10-__/External corner flashing, t =1 /1.2 mm

Facing sheet cutting at site

by length b = element thickness

+

-

b

50

231

332/333

201

131

001

312

325

309

001. Ruukki ® Patina Panel

321

352/332

145

131. COR-TEN external corner flashing

312. Mineral wool batten

309. /EA3JSCN30025/ Joint sealing corner Nordic

325. /EA3SM312___/ Sealing compound during inst.

to outer female groove in length equivalent to

vertical joint flashing width and inner female groove

from panel end to sealing

321. /EA3SM312___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

30 ≥ 30

327

303

303. /EA3SS1210/ Sealing tape 327. Elastic polyurethane foam

*Screw material stainless steel

131

Page 18: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC05-1E-EN

22.09.2021

Ruukki

17.05.2021

1:5

Internal corner, horizontal section

Horizontal installation

Ruukki ® Patina Panel

-

+

+

001. Ruukki ® Patina Panel

≥ 30

≥ 50

001

234

242

201

312

325

231

332/333

201

312

307

151

325

325

50

321

352/332

151. COR-TEN internal corner flashing

152. Internal corner flashing, t = 0.6 mm, according to project

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

234. Flat head flashing fastener

242. Fastener screw, without washer

307. /EA3JSN7525/ Joint sealing Nordic

312. Mineral wool batten

321. /EA3SM312___/ Sealing compound

325. /EA3SM312___/ Sealing compound during installation to outer female groove

332. /CA3SP814/ Separating piece EPDM

352. Lead-in rubber grommet

in length equivalent to vertical joint flashing width and inner female groove from panel end to sealing

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

30

303

327

303. /EA3SS1210/ Sealing tape

327. Elastic polyurethane foam

Screw drilling tip can be

cut off after installation

152 if necessary

152 if necessary

*Screw material stainless steel

Page 19: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC06-1E-EN

Ruukki

17.05.2021

1:5

Bitumen roofing felt, vertical section

Horizontal installation, parapet, side eaves

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

- +

265

001

131

163

232

161

312

101

162

311

171

350

332/333

306

101. /EA1D___/ Purlin

131. COR-TEN vertical joint flashing

162. Cover flashing, t = 0.6 mm, according to project

163. Perforated storm flashing, t = 0.6 mm, acc. to project

161. COR-TEN eave flashing, t = 0.7 mm, acc. to project

171. Insulation support flashing, t = 0.6 mm,

according to project

232. Flashing fastener, without washer *

265. Fastener screw to wood, washer with sealing *

311. Mineral wool

312. Mineral wool batten

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

Horizontal

support studwork

Plywood

Vertical

support studwork

Waterproofing is not fastened

to structures below L~400 mm

Reverse dip is made of Leca-gravel,

Siporex chips or woolsheets cut to form

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Secondary steel supports (t-steel)

for the element according to

structural designer.

Vapour barrier and insulation support

fastening, check SPBC06-7E

of the panel)

*Screw material stainless steel

Page 20: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC06-2E-EN

Ruukki

17.05.2021

1:5

Bitumen roofing felt, vertical section

Horizontal installation, parapet, end eaves

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

001

131

312

101

265

311

172

332/333

163

232

161

306

350

101. /EA1D___/ Purlin

131. COR-TEN vertical joint flashing

163. Perforated storm flashing, t = 0.6 mm, acc. to project

161. COR-TEN eave flashing, t = 0.7 mm, acc. to project

172. Insulation support flashing, t = 0.6 mm,

according to project

232. Flashing fastener, without washer *

265. Fastener screw to wood, washer with sealing *

311. Mineral wool

312. Mineral wool batten

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

Horizontal

support studwork

Plywood

Vertical

support studwork

Waterproofing is not fastened

to structures below L~400 mm

Ventilation grooves

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Secondary steel supports (t-steel)

for the element according to

structural designer.

Vapour barrier and insulation support

fastening, see SPBC06-7E

of the panel)

*Screw material stainless steel

Page 21: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

- +

102. /EA1EP___/ Purlin

103. Flashing for fastening / insulation support flashing,

162. Cover flashing, t = 0.6 mm, according to project

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

Ruukki's delivery

163. Perforated storm flashing, t = 0.6 mm, acc. to project

161. Eave flashing, t = 0.6 mm, according to project

232. Flashing fastener, without washer *

265. Fastener screw to wood, washer with sealing *

326. /EA3SM312___/ Sealing compound during inst.

to outer male groove full length of element and

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Vapour barrier and insulation support

fastening, see SPBC06-7E

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC06-3E-EN

Ruukki

17.05.2021

1:5

Bitumen roofing felt, vertical section

and diagonal inst. Parapet, side eaves

Ruukki ® Patina Panel vertical-

t=3 mm, according to project

inner female groove 60 mm in length of element

001

201

131

326

326

102

Horizontal

support studwork

Plywood

Vertical

support studwork

162

Waterproofing is not fastened

to structures below L~400 mm

311

Reverse dip is made of Leca-gravel,

Siporex chips or woolsheets cut to form

103

242

163

161

306

232

350

265

332/333

321

332/333

352/332

001. Ruukki ® Patina Panel

135. COR-TEN flashing

306. ISO-BUTYL self adhesive tape 2x10 mm

321. /EA3SM312___/ Sealing compound

311. Mineral wool

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

of the panel)

242. Fastener screw, without washer *

*Screw material stainless steel

Page 22: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

- +

102. /EA1EP___/ Purlin

104. Flashing for fastening / insulation support flashing,

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

Ruukki's delivery

163. Storm flashing, t = 0.6 mm, according to project

161. Eave flashing, t = 0.6 mm, according to project

232. Flashing fastener, without washer *

242. Fastener screw, without washer *

265. Fastener screw to wood, washer with sealing *

311. Mineral wool

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC06-4E-EN

Ruukki

17.05.2021

1:5

Bitumen roofing felt, vertical section

and diagonal inst. Parapet, end eaves

Ruukki ® Patina Panel vertical-

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Vapour barrier and insulation support

fastening, see SPBC06-7E

t=3 mm, according to project

326. /EA3SM312___/ Sealing compound during inst.

to outer male groove full length of element and

inner female groove 60 mm in length of element

102

001

326

326

Horizontal

support studwork

Plywood

Vertical

support studwork

Waterproofing is not fastened

to structures below L~400 mm

311

104

242

Ventilation grooves

265

332/333

163

232

161

306

350

201

131

321

332/333

352/332

001. Ruukki ® Patina Panel

135. COR-TEN flashing

306. ISO-BUTYL self adhesive tape 2x10 mm

321. /EA3SM312___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

of the panel)

*Screw material stainless steel

Page 23: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC06-5E-EN

Ruukki

17.05.2021

1:5

Rofiled sheet roof deck, vertical section

Horizontal installation, cantilever eaves, side eaves

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

167

171

311

312

101

232

001

131

167

350

231

332/333

321

311. Mineral wool

Ruukki's delivery

171. Insulation support flashing, t = 0.6 mm, according to project

232. Flashing fastener, without washer *

231. Flashing fastener, washer with sealing *

164. COR-TEN storm flashing, t = 0.7 mm, according to project

131. COR-TEN vertical joint flashing

312. Mineral wool batten

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

101. /EA1D___/ Purlin

167. COR-TEN eave flashing, t = 0.7 mm, according to project

321. /EA3SM312___/ Sealing compound

Plywood

Wooden wedge

Load bearing profiled sheet

sealed with a flashing on both sides

Perforated profiled sheet

Water drainage system

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Element is cut at the point where it intersects

with the steel structure. Vapour barrier is

taped around the steel.

Vapour barrier and insulation support

fastening, see SPBC06-7E

of the panel)

*Screw material stainless steel

Page 24: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC06-6E-EN

Ruukki

17.05.2021

1:5

Rofiled sheet roof deck, vertical section

Horizontal installation, cantilever eaves, end eaves

Ruukki ® Patina Panel

172

311

312

101

232

168

265

131

001

001. Ruukki ® Patina Panel

350

231

332/333

311. Mineral wool

Ruukki's delivery

172. Insulation support flashing, t = 0.6 mm, according to project

232. Flashing fastener, without washer *

231. Flashing fastener, washer with sealing *

312. Mineral wool batten

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

101. /EA1D___/ Purlin

168. COR-TEN eave flashing, t = 0.7 mm, according to project

321. /EA3SM312___/ Sealing compound

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Element is cut at the point where it intersects

with the steel structure. Vapour barrier is

taped around the steel.

Vapour barrier and insulation support

fastening, see SPBC06-7E

Ventilation

grooves

Load bearing profiled sheet

sealed with

a flashing on both sides

Plywood

164. COR-TEN storm flashing, t = 0.7 mm, according to project

131. COR-TEN vertical joint flashing

265. Fastener screw to wood, washer with sealing *

of the panel)

*Screw material stainless steel

321

Page 25: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC06-7E-EN

Ruukki

17.05.2021

1:2

and insulation support flashing fastening

Horizontal installation, Vapour barrier

Ruukki ® Patina Panel

232

232

173

302

171. Insulation support flashing, t = 0.6 mm, according to project

172. Insulation support flashing, t = 0.6 mm

173. Flat flashing to vapour barrier fastening, t = 0.6 mm, according to project

232. Flashing fastener, without washer

302. /EA3SS410/ Sealing tape, between panel and vapour barrier

Ruukki's delivery

171 / 172, to be cut at panel support

Vapour barrier movable joint

Page 26: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC07-1E-EN

22.09.2021

Ruukki

17.05.2021

1:5

Window, vertical section

Horizontal installation

Ruukki ® Patina Panel

- +

001. Ruukki ® Patina Panel

321

234

234

321

103

001

231

181

231

186

187

231

306

350

350

332/333

332/333

306

188

186. Support- / cover flashing, t = 0.6 mm, acc. to project

187. COR-TEN External window sill, t=0.7 mm

Ruukki's delivery

231. Flashing fastener, washer with sealing *

321. /EA3SM312___/ Sealing compound

181. COR-TEN Drip flashing, t = 0.7 mm, acc. to project

103. /EA1W___/ Window purlin

188. Support- / cover flashing, t = 0.6 mm, acc. to project

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

350. PVC tape

/333. /CA3SE410/ Separating strip EPDM

300

300. /EA3SWE54318/ Expandable sealing

Note! Openings must be taken into account in dimensioning of elements.

Note! When thermal purlin (window purlin, for example) is used around the opening, the thermal holes of the purlin must

be sealed with tape (aluminium tape, for example) from the inside of the purlin to ensure tightness of the purlin.

Note! Remember to seal the grooves of the elements joining the window during the installation with elastic sealant to

outer female groove to length equivalent to vertical joint flashing widht).

Supporting structures, if necessary, according to structural designer .

*Screw material stainless steel

321

234. Flat head flashing fastener

312. /EAWS___/ Mineral wool band

(plastic tape facing inside)

312

300

312

Page 27: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC07-2E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Window, horizontal section

Horizontal installation

Ruukki ® Patina Panel

-

+

001. Ruukki ® Patina Panel

001

321

234

103

188

231

231

325

325

332/333

306

350

332/333

321

188. COR-TEN Cover flashing, t = 0.7 mm, acc. to project

231. Flashing fastener, washer with sealing *

234. Flat head flashing fastener

321. /EA3SM312___/ Sealing compound

103. /EA1W___/ Window purlin

Ruukki's delivery

325. /EA3SM312___/ Sealing compound during inst.

to outer and inner female grooves

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape

300

Note! Openings must be taken into account in dimensioning of elements.

Note! When thermal purlin (window purlin, for example) is used around the opening, the thermal holes of the purlin must

be sealed with tape (aluminium tape, for example) from the inside of the purlin to ensure tightness of the purlin.

Note! Remember to seal the grooves of the elements joining the window during the installation with elastic sealant to

outer female groove to length equivalent to vertical joint flashing widht.

Supporting structures, if necessary, according to structural designer.

*Screw material stainless steel

312

300. /EA3SWE54318/ Expandable sealing

312. /EAWS___/ Mineral wool band

(plastic tape facing inside)

Page 28: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

≥ 5

0≥ 5

0

- +

321

321

001

321

231

201

182

183

321

321

231

201

185

332/333

350

001. Ruukki ® Patina Panel

332/333

231

332/333

350

306

352/332

352

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC07-3E-EN

22.09.2021

Ruukki

17.05.2021

1:5

vertical section, large window, supporting structure

Horizontal installation, system window,

Ruukki ® Patina Panel

Note! Openings must be taken into account in dimensioning of elements.

Note! System window is installed during installation of elements. Fastening according to window manufacturers

instructions.

Note! Remember to seal the grooves of the elements joining the window during the installation with sealant to outer

female groove to length equivalent to vertical joint flashing and inner female groove in length of sealing (SPBC02-1E).

Supporting structures according to structural designer.

Ruukki's delivery

183. Storm flashing, t = 0.6 mm, according to project

185. COR-TEN Cover flashing, t = 0.7 mm, acc. to project

201. Self-drilling element screw, washer with sealing *

321. /EA3SM312___/ Sealing compound

182. COR-TEN Drip flashing, t = 0.7 mm, acc. to project

231. Flashing fastener, washer with sealing *

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

350. PVC tape

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

303

303

303. /EA3SS1210/ Sealing tape

*Screw material stainless steel

300

312

300

312

300. /EA3SWE54318/ Expandable sealing

(plastic tape facing inside)

312. /EAWS___/ Mineral wool band

Page 29: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

≥ 50

-

+323

185

201

001

325

321

350

332/333

231

321

332/333

325

001. Ruukki ® Patina Panel

352/332

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC07-4E-EN

22.09.2021

Ruukki

17.05.2021

1:2

horizontal section, large window

Horizontal installation, system window,

Ruukki ® Patina Panel

Note! Openings must be taken into account in dimensioning of elements.

Note! System window is installed during installation of elements. Fastening according to window manufacturers

instructions.

Note! Remember to seal the grooves of the elements joining the window during the installation with sealant to outer

female groove to length equivalent to vertical joint flashing and inner female groove in length of sealing (SPBC02-1E).

Supporting structures according to structural designer.

185. COR-TEN cover flashing, t = 0.7 mm, acc. to project

201. Self-drilling element screw, washer with sealing *

Ruukki's delivery

231. Flashing fastener, washer with sealing *

321. /EA3SM312___/ Sealing compound

325. /EA3SM312___/ Sealing compound during inst.

to outer and inner female grooves

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape

352. Lead-in rubber grommet

303. /EA3SS1210/ Sealing tape

303

*Screw material stainless steel

300

312

300. /EA3SWE54318/ Expandable sealing

(plastic tape facing inside)

312. /EAWS___/ Mineral wool band

Page 30: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC08-1E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Door, vertical section

Horizontal installation

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

321

310

100

191

232

234

321

001

231

232

181

189

332/333

350

321

306

321

350

191. Cover flashing, t = 0.6 mm,

231. Flashing fastener, washer with sealing * 321. /EA3SM312___/ Sealing compound

310. Mineral wool

181. COR-TEN Drip flashing, t = 0.7 mm,

101. EA1D___/ Door frame stud

189. Cover flashing, t = 0.6 mm,

234. Flat head flashing fastener

232. Flashing fastener, without washer *

Ruukki's delivery

according to project

according to project

according to project 306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape

300

Note! Openings must be taken into account in dimensioning of elements.

Note! Remember to seal the grooves of the elements joining the door during the installation with elastic sealant to outer

female groove to length equivalent to vertical joint flashing widht (SPBC02-1E).

Supporting structures, if necessary, according to structural designer.

*Screw material stainless steel

312

300. /EA3SWE54318/ Expandable sealing

(plastic tape facing inside)

312. /EAWS___/ Mineral wool band

Page 31: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

-

+

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC08-2E-EN

22.09.2021

Ruukki

17.05.2021

1:2

Door, horizontal section

Horizontal installation

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

234

321

232

310

191

100

321

192

232

231

001

325

332/333

321

350

231. Flashing fastener, washer with sealing *

232. Flashing fastener, without washer *

321. /EA3SM312___/ Sealing compound

310. Mineral wool

191. Cover flashing, t = 0.6 mm, according to project

192. COR-TEN Cover flashing, t = 0.7 mm, acc. to project

101. EA1D___/ Door frame stud 312. Mineral wool batten

234. Flat head flashing fastener

Ruukki's delivery

325. /EA3SM312___/ Sealing compound during

inst. to outer and inner female grooves

332. /CA3SP814/ Separating piece EPDM

333. /CA3SE410/ Separating strip EPDM

350. PVC tape

312

Note! Openings must be taken into account in dimensioning of elements.

Note! Remember to seal the grooves of the elements joining the door during the installation with elastic sealant to outer

female groove to length equivalent to vertical joint flashing widht (SPBC02-1E).

Supporting structures, if necessary, according to structural designer.

*Screw material stainless steel

300

300. /EA3SWE54318/ Expandable sealing

(plastic tape facing inside)

Page 32: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC08-3E-EN

Ruukki

17.05.2021

1:5

Overhead door, vertical section

Horizontal installation

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

303

330

193

201

231

332/333

001

330

342

331

101

232

312

194

350

321

332/333

321

352/332

201. Self-drilling element screw, washer with sealing *

321. /EA3SM312___/ Sealing compound

231. Flashing fastener, washer with sealing *

193. COR-TEN drip- / cover flashing, t = 0.7 mm, acc. to project

Ruukki's delivery

330. PU insulation

331. EPDM sealing

342. L-profile

101. EA1D___/ Door frame stud

232. Flashing fastener, without washer *

312. Mineral wool batten

194. Drip- / cover flashing, t = 0.6 mm, acc. to project

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape

352. Lead-in rubber grommet

Note! Openings must be taken into account in dimensioning of elements.

Note! Remember to seal the grooves of the elements joining the door during the installation with elastic sealant to outer

female groove to length equivalent to vertical joint flashing widht (SPBC02-1E).

Supporting structures according to structural designer.

303. /EA3SS1210/ Sealing tape

*Screw material stainless steel

Page 33: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

+

-

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC08-4E-EN

Ruukki

17.05.2021

1:5

Overhead door, horizontal section

Horizontal installation

Ruukki ® Patina Panel

001

231

201

193

330

342

331

101

312

232

325

332/333

194

330

350

001. Ruukki ® Patina Panel

321

332/333

321

352/332

231. Flashing fastener, washer with sealing *

193. COR-TEN Cover flashing, t = 0.7 mm, acc. to project

201. Self-drilling element screw, washer with sealing *

302. /EA3SS410/ Sealing tape

Ruukki's delivery

330. PU insulation

331. EPDM sealing

342. L-profile

232. Flashing fastener, without washer *

101. EA1D___/ Door frame stud

312. Mineral wool batten

325. /EA3SM312___/ Sealing compound during

inst. to outer and inner female grooves

194. Drip- / cover flashing, t = 0.6 mm, acc. to project

321. /EA3SM312___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape

352. Lead-in rubber grommet

Note! Openings must be taken into account in dimensioning of elements.

Note! Remember to seal the grooves of the elements joining the door during the installation with elastic sealant to outer

female groove to length equivalent to vertical joint flashing widht (SPBC02-1E).

Supporting structures according to structural designer.

303

*Screw material stainless steel

Page 34: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC09-1E-EN

Ruukki

16.12.2021

1:5

Horizontal joint, Vertical section, option 1

Vertical installation,

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel, vertical installation

- +

001

131

332/333

231

201

303

327

310

321

131. COR-TEN Vertical joint flashing

158. Horizontal joint flashing, HIARC t = 0.6 mm

201. Self-drilling element screw, washer with sealing *

327. Elastic polyurethane foam

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

231. Flashing fastener, washer with sealing*

*Screw material stainless steel

352/332

158

332/333

332

231

325. /EA3SM310___/ Sealing compound during inst.

303. /EA3SS1210/ Sealing tape

310. Mineral wool

321. /EA3SM310___/ Sealing compound

to outer female groove in full length of panel

and inner female groove from panel end to sealing

325

325

325

Gap between panel

sheet and flashing for

water drainage

325

Page 35: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC09-2E-EN

Ruukki

16.12.2021

1:5

Horizontal joint, Vertical section, option 2

Vertical installation,

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel, vertical installation

-

+

001

131

332/333

231

201

303

327

310

321

131. COR-TEN Vertical joint flashing

158. Horizontal joint flashing, HIARC t = 0.6 mm

201. Self-drilling element screw, washer with sealing *

310. Mineral wool

327. Elastic polyurethane foam

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

231. Flashing fastener, washer with sealing*

*Screw material stainless steel

352/332

158

332/333

332

231

321. /EA3SM310___/ Sealing compound

201

352/332

+

Steel structure according

structural designer

Steel structure according

structural designer

159

159. Cover flashing, acc. to project

325

302. /EA3SS410/ Sealing tape

302

303. /EA3SS1210/ Sealing tape

325. /EA3SM310___/ Sealing compound during inst.

to outer female groove in full length of panel

and inner female groove from panel end to sealing

303

325

Gap between panel

sheet and flashing for

water drainage

325

325

Page 36: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External walls

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPBC09-3E-EN

Ruukki

16.12.2021

1:5

Horizontal joint, Vertical section, option 3

Vertical installation,

Ruukki ® Patina Panel

-

+

001

131

332/333

231

201

303

103

310

321

131. COR-TEN Vertical joint flashing

158. Horizontal joint flashing, HIARC t = 0.6 mm

201. Self-drilling element screw, washer with sealing *

327. Elastic polyurethane foam

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

231. Flashing fastener, washer with sealing*

*Screw material stainless steel

352/332

158

332

332

231

321. /EA3SM310___/ Sealing compound

+

Steel structure according

structural designer

159

159. Cover flashing, acc. to project

001. Ruukki ® Patina Panel, vertical installation

103. /EA1W___/ Window purlin, oval holes on the sides

350. PVC tape (on the panel ext. surface

350

under purlin)

Steel structure according

structural designer

327

302. /EA3SS410/ Sealing tape

303. /EA3SS1210/ Sealing tape

325. /EA3SM310___/ Sealing compound during inst.

to outer female groove in full length of panel

and inner female groove from panel end to sealing

157

157. Support flashing, HIARC t = 0.6 mm

302

310. Mineral wool

159

302

325

325

Gap between panel

sheet and flashing for

water drainage

325

325