Upgrading the OptiX RTN 620 to the Hybrid Radio FAQ
Transmission Network Marketing Support Dept, 2009-8-17
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 2
How to check the ODU hardware version?
Answer:
Use Navigator to execute command : cfg-get-bdversion:Bid
Example: :cfg-get-bdversion:18
BOARD-VERSION
BID BD-TYPE RVER DVER HVER ONLINE-FLAG BDVER-TIME
18 odu 0x01 0x0a 0x0004 online 2009-05-13 11:00:00
Total records :1
RVER means main version, DVER means sub version,
HVER means hardware version
So this ODU software version is 1.10,hardware version is 0x0004
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 3
There is LICENSE_LOST alarm when the SCC version is upgraded from R1 to R2/R3
Answer: There is no license control in R1 version. and R2/R3 add
this function. So we need to load the license again when the SCC
version is upgraded from R1 to R2/R3.
It doesn’t not need to load the license again if the current version is
already R2/R3
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 4
There is NO_BD_SOFT alarm in IF1A(IF1B)card when the SCC board is upgraded from R1 to R2/R3
Reason:
For R1 version, the SCC board only support one FPGA file,R2/R3
support 2 FPGA file. If the second FPGA is not loaded, there will be
NO_BD_SOFT alarm
Solution: We need to load the load the second FPGA file if1p.pga to
IF1A(IF1B) card
Remark: The board will be reset when the FGPA file is activated, the
service will be down
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 5
How to calculate the TDM license?
Example:
One RTN620 NE has 2 direction, one direction is 1+1 protection, work
mode is 16E1 、 16 QAM , the other direction is 1+0,work mod is 4E1、QPSK
If the link is 1+1 protection (HSB/FD/SD), the license should be doubled
so the license should be 2×16E1 + 4E1=36E1 at least.
Huawei RTN license have 8E1 、 16E1 、 32E1 、 48E1 、 64E1 、 128E1 、
MAX
type.
So 48E1 license should be loaded in this NE
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 6
Does Hybrid support 1+1 Protection(HSB/FD/SD)?
Answer: Yes
Remark:
There is no data cross connection platform in RTN600,so EMS6
board is needed to realize the 1+1 Protection.
For detailed configuration, please check the attachment
Hybrid MW 1+1 Preotection