Agenda• Control PC Network Connection Setup• Configure RTD

– RTD License Installation – RTD Environment Configuration– Archives

• Basic RTD use– Opening a test– Running a test– Execution View– Results View

• Protocol Analyzer• Campaign Manager• Command Line Interface• Documentation• Support

Page 3: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

UE

Control PC

Ethernet Switch

ME7834L & Control PC Setup

Page 4: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

License Installation• When starting RTD for the first time, or after

clearing the license:

• To clear the license:Start Menu > All Programs > Rapid Test Designer > License Utilities >

Clear License

Page 5: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Environment Manager• RTD Tools menu

• -> Options

•“C2K Procedures” & “MD8470 Parameters” for MD8470A setup

•“UTRAN-GERAN L3 Procedures” & “MD8480 Parameters” for MD8480 setup

•“LTE Layer 3 Procedures” & “MD8430 Parameters” for MD8430 setup

Page 6: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

C2K Procedures• For ME7843L system with two MD8470s, add second element under Group

Page 7: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

UTRAN-GERAN L3 Procedures• ipAddress set for MD8480C based on serial number

• Serial number 6200??wxyz -> ipAddress 1.1.1wx.1yz

• ueIPAddressIPv4 set for ME7834L data plane

Page 8: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

LTE Layer 3 Procedures• ipAddressIPv4 set for ME7834L data plane

Page 9: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

MD8430 Parameters• ipAddress set for MD8430A based on serial number

• Serial number 6200abcdef -> ipAddress 1.1ab.1cd.1ef

Page 10: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

MD8470 Parameters• Add elements to match the number of MD8470s in the configuration

Page 11: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

MD8480 Parameters• ipAddress set for MD8480C based on serial number

• Serial number 6200??wxyz -> ipAddress 1.1.1wx.1yz

Page 12: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Common Parameters• Set cable loss correction files

• Use full paths for correction files • Set instrumentMap tomatch ME7834L configuration

Page 13: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Archives• To add an archive:

1. Click Add Archive

2. Browse to Archive Location

3. Name Archive

Page 14: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Opening a Test

• Click Open…

• Use drop-down menu to select archive

• Select test

and click Open

Page 15: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Running Tests

• Once test has opened, simply click the Run button

• RTD moves to Execution view, and test starts to run

Page 16: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Execution View

Timers in use

User Events

Runtime MessagesDiagram View

Stop Button

Run Comments

User Input Command

Runtime Data

Message SequenceChart

Page 17: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Results View

Results Navigator

Verdict Criteria

Message Detail

Message Sequence Chart

Historic Design

Protocol Analyzer

Page 18: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Protocol Analyzer

• Message Sequence Chart and TTCN views

• Selectable layers

• Green = Configuration• Red = Protocol

• Time stamps for reference

• RTD procedure block separators

Page 19: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Campaigns

• Drag and drop testcases into campaign

• Overwrite default timeout for specific tests

• Individual repeat condition for each test• Run once• Run until fail or max runs• Run until pass or max runs

Page 20: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Campaign Results

• Results are displayed for individual campaign runs, and an overview can be displayed to compare with past runs

Page 21: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Command Line Interface

• Create batch files for automated testing of sequences of testcases

• Can be run remotely using a client PC connected to the control PC

Page 22: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Documentation

• Stored in C:\Program Files\Anritsu\Rapid Test Designer\4.10.0\Docs– MX786201A_4.10.0_Customer_Release_Note.pdf– RTD (Rapid Test Designer) User Guide -

MX786201A.pdf– RTD_Quick_Start_Guide.pdf– RTD_Tutorial_Help.pdf– Reference Manual and Parameters doc for each

procedure library

Page 23: RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License Installation –RTD Environment Configuration –Archives Basic

Support1. Register at https://secure.eu.anritsu.com/wireless-support/index.php

2. Raise tickets online or send email to: