5
COMM. GARBAGE RES. GARBAGE PMT 6 CLASS B BICYCLES RESIDENTIAL OUTDOOR AMENITY / GARDEN EXIT 01 COMM. RETAIL COMMERCIAL LOADING BAY O.H. GATE RETAIL STORE 2,170 sf RETAIL STORE 2,700 SF RAMP DN @10% MAIL O.H.GATE RESIDENTIAL LOBBY LANE OAK STREET W 16TH AVE RT-2 C2 RT-2 EXIT VENT B B A A C C REFER TO LANDSCAPE DRAWINGS DN @14% DN @10% DATE DRAWN BY CHECKED BY SCALE JOB NUMBER GROUND FLOOR DATE 1/8" = 1'- 0" A-3.01 NOTES REVISIONS PLOT INFO. DATE DRAWN BY CHECKED BY SCALE JOB NUMBER 3195 OAK STREET VANCOUVER, B.C. MIXED USE RESIDENTIAL BUILDING SS AB 1281 N 1. DEC 23 2012 ISSUED FOR REZONING NO. DATE REMARKS

RT-2 C2 - Vancouver · rt-2 c2 rt-2 roof terrace unit c7 unit c8 c9 −1b − 515 sf c10 −1b − 449 sf c11 −2b − 915 sf b b a a c c date drawn by checked by scale job number

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RT-2 C2 - Vancouver · rt-2 c2 rt-2 roof terrace unit c7 unit c8 c9 −1b − 515 sf c10 −1b − 449 sf c11 −2b − 915 sf b b a a c c date drawn by checked by scale job number

COMM. GARBAGE

RES. GARBAGE

PMT

6 CLASS BBICYCLES

RESIDENTIALOUTDOORAMENITY /GARDEN

EXIT

01

COMM.RETAIL

COMMERCIAL LOADING BAY

O.H. GATE

RETAIL STORE2,170 sf

RETAIL STORE2,700 SF

RA

MP D

N @

10%

MAIL

O.H.GATE

RESIDENTIALLOBBY

LANE

OA

K S

TR

EET

W 16TH AVE

RT-2 C2

RT-2

EXIT

VENT

BB

AA

CC

REFER TOLANDSCAPEDRAWINGS

DN

@14%

DN

@10%

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

GROUND

FLOOR

DATE

1/8" = 1'- 0"

A-3.01

NOTES

REVISIONS

PLOT INFO.

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

3195 OAK STREETVANCOUVER, B.C.

MIXED USE RESIDENTIAL BUILDING

SS

AB

1281

N

1. DEC 23 2012 ISSUED FOR REZONING

NO. DATE REMARKS

Page 2: RT-2 C2 - Vancouver · rt-2 c2 rt-2 roof terrace unit c7 unit c8 c9 −1b − 515 sf c10 −1b − 449 sf c11 −2b − 915 sf b b a a c c date drawn by checked by scale job number

1B

625 SF

DEN

BALCONY

BALCONY

BALCONY

1B

558 SF

2B

788 SF

2B

835 SF

BALCONY

BALCONY

BALCONY

LANE

OA

K S

TR

EET

W 16TH AVE

RT-2 C2

RT-2

ROOF

TERRACE @

L2

2B

773 SF

2B

816 SF

ROOF

TERRACE @

L2

1B

510 SF

BALCONY

4 62 53 71

1B

526 SF

1B

609 SF

1B

591 SF

UNIT C1

UNIT C2

UNIT C3

UNIT C4

UNIT B1

UNIT B2 UNIT B3

UNIT B4

UNIT B5

UNIT B6

4 62 5

B

D

F

A

3

C

7

E

1

BB

AA

CC

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

LEVEL 2

DATE

1/8" = 1'- 0"

A-3.02

NOTES

REVISIONS

PLOT INFO.

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

3195 OAK STREETVANCOUVER, B.C.

MIXED USE RESIDENTIAL BUILDING

SS

AB

1281

N

1. DEC 23 2012 ISSUED FOR REZONING

NO. DATE REMARKS

Page 3: RT-2 C2 - Vancouver · rt-2 c2 rt-2 roof terrace unit c7 unit c8 c9 −1b − 515 sf c10 −1b − 449 sf c11 −2b − 915 sf b b a a c c date drawn by checked by scale job number

LANE

OA

K S

TR

EET

W 16TH AVE

RT-2 C2

RT-2

OUTDOOR

AMENITY

REFER TO

LANDSCAPE

DRAWINGS

ROOF

TERRACE

4 62 5

B

D

F

A

3

C

7

E

1

BALCONY

2B

785 SF

BALCONY

BALCONY

BALCONY

2B

828 SF

1B

510 SF

BALCONYBALCONY

2B

766 SF

1B

604 SF

1B

552 SF

1B

609 SF

2B

850 SF

UNIT C5

UNIT C2a

UNIT C3a

UNIT C6

UNIT B7 UNIT B3a

UNIT B4 UNIT B5

BB

AA

CC

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

LEVEL 3

DATE

1/8" = 1'- 0"

A-3.03

NOTES

REVISIONS

PLOT INFO.

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

3195 OAK STREETVANCOUVER, B.C.

MIXED USE RESIDENTIAL BUILDING

SS

AB

1281

N

1. DEC 23 2012 ISSUED FOR REZONING

NO. DATE REMARKS

Page 4: RT-2 C2 - Vancouver · rt-2 c2 rt-2 roof terrace unit c7 unit c8 c9 −1b − 515 sf c10 −1b − 449 sf c11 −2b − 915 sf b b a a c c date drawn by checked by scale job number

LANE

OA

K S

TR

EET

W 16TH AVE

RT-2 C2

RT-2OUTDOOR

AMENITY @

L3

ROOF

TERRACE @

L3

BALCONY

4 62 5

B

D

F

A

3

C

7

E

1

BALCONY

2B

785 SF

BALCONY

BALCONY

BALCONY

2B

828 SF

1B

510 SF

BALCONYBALCONY

2B

766 SF

1B

604 SF

1B

552 SF

1B

609 SF

2B

850 SF

UNIT C5

UNIT C2a

UNIT C3a

UNIT C6

UNIT B7 UNIT B3a

UNIT B4 UNIT B5

BAY WINDOW @ L5

BAY WINDOW @ L4

BB

AA

CC

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

LEVEL 4-5

DATE

1/8" = 1'- 0"

A-3.04

NOTES

REVISIONS

PLOT INFO.

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

3195 OAK STREETVANCOUVER, B.C.

MIXED USE RESIDENTIAL BUILDING

SS

AB

1281

N

1. DEC 23 2012 ISSUED FOR REZONING

NO. DATE REMARKS

Page 5: RT-2 C2 - Vancouver · rt-2 c2 rt-2 roof terrace unit c7 unit c8 c9 −1b − 515 sf c10 −1b − 449 sf c11 −2b − 915 sf b b a a c c date drawn by checked by scale job number

ROOF

TERRACE

ROOF

TERRACE

ROOF

TERRACE

2B+DEN

1,105 SF

2B+DEN

1,027 SF

LANE

OA

K S

TR

EET

W 16TH AVE

RT-2 C2

RT-2

ROOF

TERRACE

UNIT C7

UNIT C8

C9 −1B −

515 SF

C10 −1B −

449 SF

C11 −2B −

915 SF

BB

AA

CC

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

LEVEL 6

DATE

1/8" = 1'- 0"

A-3.05

NOTES

REVISIONS

PLOT INFO.

DATE

DRAWN BY

CHECKED BY

SCALE

JOB NUMBER

3195 OAK STREETVANCOUVER, B.C.

MIXED USE RESIDENTIAL BUILDING

SS

AB

1281

N

1. DEC 23 2012 ISSUED FOR REZONING

NO. DATE REMARKS