2
Specication Sheet 2036.B 7/2011 201 Ivyland Road Ivyland, PA 18974 USA TEL: (215) 293-0401 FAX: (215) 293-0445 http://www.lmipumps.com ROYTRONIC EXCEL™ Series AD Metering Pump Notes: 1. Where X = control codes 9, 8, 2. 2. Liquid End model codes ending with NI, SI, NM, SM, NU, SU, NP or SP. 3. Liquid End model codes ending with AI, HI, AM, HM, AU, HU, AP or HP. 4. Type 316 stainless steel or PTFE may be specied. 5. PVDF, PVC, Polypropylene, or Type 316 stainless steel may be specied. 6. PVDF, Polypropylene, or Type 316 stainless steel may be specied. 7. 6 ft. (1.8 m) of vinyl suction tubing may be specied in place of polyethylene for the suction side only. 1/4” pipe thread may be specied. GENERAL Chemical metering pumps shall be positive displacement, Liquifram™ type pumps with a NEMA 4X/IP-65 enclosure. The external signal/ equipment interface shall meet IP-68 standards. Relevant model codes are NSF Certied, UL/CUL or CE certied. Output volume shall be adjustable while pumps are in operation from zero to maximum capacity of: ROYTRONIC EXCEL™ Series AD with FASTPRIME™ Liquid End AD91, AD81, AD21 AD94, AD84, AD24 AD95, AD85, AD25 AD96, AD86, AD26 0.21 GPH 0.50 GPH 1.0 GPH 2.0 GPH (0.8 liters per hour) (1.9 liters per hour) (3.8 liters per hour) (7.6 liters per hour) Chemical metering pumps shall be capable, without a hydraulically backed diaphragm, of injecting solutions against pressures up to: ROYTRONIC EXCEL™ Series AD with FASTPRIME™ Liquid End AD91, AD81, AD21 AD94, AD84, AD24 AD95, AD85, AD25 AD96, AD86, AD26 250 psi 250 psi 110 psi 50 psi (17.2 bar) (17.2 bar) (7.6 bar) (3.5 bar) The FastPrime™ Liquid End 2 shall be equipped with a valve that allows for opening the head to atmospheric pressure to assist in pump priming. The AutoPrime™ Liquid End 3 shall be equipped with a valve that allows for constant removal of vapors and gasses inherent in effervescent chemicals. The AutoPrime™ valve shall enable the pump to be primed automatically. NOTE: AutoPrime™ liquid ends will recirculate a percentage of discharge chemical back to supply. Depending on application, output may be reduced up to 50%. Variables include supplier piping, stroke length and speed setting. Maximum pressure is 150 psi for ADX1, ADX4, 110 psi for ADX5, 50 psi for ADX6 models 1 . PUMP SPEED: All models are 120 strokes per minute max. SERIES AD2 Series AD2 metering pumps shall have a liquid crystal display to indicate stroke speed of the pump and theoretical ow. Control and adjustment for stroke frequency shall be by means of a tactile keypad. Adjustment for stroke length shall be by means of a readily accessible dial knob. A pulse indicator light shall ash green between strokes when pumping. The pump shall be equipped with an on/off button and a low level oat switch Input. When the low level sensor registers empty, the low level indicator light shall turn red and the pump shall turn off when it registers an empty level. SERIES AD8 Series AD8 metering pumps shall have a liquid crystal display to indicate stroke speed of the pump and theoretical ow. Control shall be selectable between internal and external modes as well as stroke frequency adjustment by means of a tactile keypad. Adjustment for stroke length shall be by means of a readily accessible dial knob. A pulse indicator light shall ash green between strokes when pumping in internal mode, and yellow between strokes when pumping in external mode. When in external mode, Series AD8 units shall accept 4-20 mA input signal or external pulse signal for control of pump speed. The pump shall be capable to support external connection requirements for remote start/stop or pulse divide/multiply functions or a power supply for remote powered devices. The pump shall be equipped with an on/ off button and a dual low level oat switch input. When the dual low level sensor registers empty, the low level indicator light shall turn yellow when a low level is registered and red when an empty level is registered. The pump shall turn off when it registers an empty level. The pump shall be equipped with a universal voltage supply capability. SERIES AD9 Series AD9 metering pumps shall have a graphical display to indicate stroke speed of the pump and theoretical ow. Control shall be selectable between internal and external modes as well as stroke frequency adjustment by means of a tactile keypad. Adjustment for stroke length shall be by means of a readily accessible dial knob. The pump shall have the following control modes: Manual, mA, pulse multiply/batch accumulate, pulse divide and timer. Conguration mode settings shall allow for specic pump category settings and adjustments. A pulse indicator light shall ash green between strokes when pumping in internal mode, and yellow between strokes when pumping in external mode. When in external mode, Series AD9 units shall accept 4-20 mA input signal or external pulse signal for control of pump speed. The pump shall be capable to support external connection requirements for remote start/stop or pulse divide/multiply options or output for a power supply for remote powered devices. The pump shall be capable to support external connection capabilities for a digi-pulse or ow meter input or ow meter sensor. The pump shall be capable to support external connection for a remote internal/external input or 4-20 mA output or pacing output or alarm output. The pump shall be equipped with an on/off button and a dual low level oat switch input. When the dual low level sensor registers empty, the low level indicator light shall turn yellow when a low level is registered and red when an empty level is registered. The pump shall turn off when it registers an empty level. The pump shall be equipped with a universal voltage supply capability. DRIVE The pump drive shall be totally enclosed with no exposed moving parts. Electronic pulser shall be supplied with quick connect terminals at least .110” wide (2.79 mm). Electronics shall be housed in a chemical resistant enclosure for maximum protection against chemical spillage. Electrical power consumption shall not exceed 25 watts per hour under full speed and maximum pressure conditions. Pump weight shall not exceed 10 lbs (4.75 kg). PRESSURE RELIEF The LMI 4-Function Valve installed with a FastPrime TM or AutoPrime TM Liquid End is recommended to provide automatic pressure relief. MATERIAL Chemical metering pump housing shall be of chemically resistant glass ber reinforced thermoplastic. All exposed fasteners shall be stainless steel. Chemical metering pump valves shall be ball type, with ceramic balls 4 . Valves shall be serviceable by replacing the cartridge valve assembly. Pump head shall be of transparent acrylic 5 material capable of resisting the pumped chemical. Fittings and connections at pump head shall be PVC 6 . CHECK VALVES AND TUBING A total of 16 ft (4.8 m) of polyethylene tubing 7 shall be provided per pump complete with compression connections. A foot valve with integral one piece strainer shall be provided for the suction line, and an injection check/back pressure valve with ½” NPT male connection for the injection point.

ROYTRONIC EXCEL™ Series AD Metering Pump...AD95, AD85, AD25 AD96, AD86, AD26 – – – 250 psi 250 psi 110 psi 50 psi (17.2 bar) (17.2 bar) (7.6 bar) (3.5 bar) The FastPrime Liquid

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

  • Specification Sheet

    2036.B 7/2011

    201 Ivyland RoadIvyland, PA 18974 USA

    TEL: (215) 293-0401FAX: (215) 293-0445

    http://www.lmipumps.com

    ROYTRONIC EXCEL™ Series AD Metering Pump

    Notes:1. Where X = control codes 9, 8, 2.2. Liquid End model codes ending with NI, SI, NM, SM, NU, SU, NP or SP.3. Liquid End model codes ending with AI, HI, AM, HM, AU, HU, AP or HP.4. Type 316 stainless steel or PTFE may be specified.

    5. PVDF, PVC, Polypropylene, or Type 316 stainless steel may be specified.6. PVDF, Polypropylene, or Type 316 stainless steel may be specified.7. 6 ft. (1.8 m) of vinyl suction tubing may be specified in place of polyethylene

    for the suction side only. 1/4” pipe thread may be specified.

    GENERALChemical metering pumps shall be positive displacement, Liquifram™ type pumps with a NEMA 4X/IP-65 enclosure. The external signal/equipment interface shall meet IP-68 standards. Relevant model codes are NSF Certified, UL/CUL or CE certified. Output volume shall be adjustable while pumps are in operation from zero to maximum capacity of:

    ROYTRONIC EXCEL™ Series AD with FASTPRIME™ Liquid End

    AD91, AD81, AD21 AD94, AD84, AD24 AD95, AD85, AD25 AD96, AD86, AD26

    – – – –

    0.21 GPH 0.50 GPH 1.0 GPH 2.0 GPH

    (0.8 liters per hour) (1.9 liters per hour) (3.8 liters per hour) (7.6 liters per hour)

    Chemical metering pumps shall be capable, without a hydraulically backed diaphragm, of injecting solutions against pressures up to:

    ROYTRONIC EXCEL™ Series AD with FASTPRIME™ Liquid End

    AD91, AD81, AD21 AD94, AD84, AD24 AD95, AD85, AD25 AD96, AD86, AD26

    – – –

    250 psi 250 psi 110 psi 50 psi

    (17.2 bar) (17.2 bar) (7.6 bar) (3.5 bar)

    The FastPrime™ Liquid End2 shall be equipped with a valve that allows for opening the head to atmospheric pressure to assist in pump priming. The AutoPrime™ Liquid End3 shall be equipped with a valve that allows for constant removal of vapors and gasses inherent in effervescent chemicals. The AutoPrime™ valve shall enable the pump to be primed automatically.

    NOTE: AutoPrime™ liquid ends will recirculate a percentage of discharge chemical back to supply. Depending on application, output may be reduced up to 50%. Variables include supplier piping, stroke length and speed setting. Maximum pressure is 150 psi for ADX1, ADX4, 110 psi for ADX5, 50 psi for ADX6 models1.

    PUMP SPEED:All models are 120 strokes per minute max.

    SERIES AD2Series AD2 metering pumps shall have a liquid crystal display to indicate stroke speed of the pump and theoretical flow. Control and adjustment for stroke frequency shall be by means of a tactile keypad. Adjustment for stroke length shall be by means of a readily accessible dial knob. A pulse indicator light shall flash green between strokes when pumping. The pump shall be equipped with an on/off button and a low level float switch Input. When the low level sensor registers empty, the low level indicator light shall turn red and the pump shall turn off when it registers an empty level.

    SERIES AD8Series AD8 metering pumps shall have a liquid crystal display to indicate stroke speed of the pump and theoretical flow. Control shall be selectable between internal and external modes as well as stroke frequency adjustment by means of a tactile keypad. Adjustment for stroke length shall be by means of a readily accessible dial knob. A pulse indicator light shall flash green between strokes when pumping in internal mode, and yellow between strokes when pumping in external mode. When in external mode, Series AD8 units shall accept 4-20 mA input signal or external pulse signal for control of pump speed. The

    pump shall be capable to support external connection requirements for remote start/stop or pulse divide/multiply functions or a power supply for remote powered devices. The pump shall be equipped with an on/off button and a dual low level float switch input. When the dual low level sensor registers empty, the low level indicator light shall turn yellow when a low level is registered and red when an empty level is registered. The pump shall turn off when it registers an empty level. The pump shall be equipped with a universal voltage supply capability.

    SERIES AD9Series AD9 metering pumps shall have a graphical display to indicate stroke speed of the pump and theoretical flow. Control shall be selectable between internal and external modes as well as stroke frequency adjustment by means of a tactile keypad. Adjustment for stroke length shall be by means of a readily accessible dial knob. The pump shall have the following control modes: Manual, mA, pulse multiply/batch accumulate, pulse divide and timer. Configuration mode settings shall allow for specific pump category settings and adjustments. A pulse indicator light shall flash green between strokes when pumping in internal mode, and yellow between strokes when pumping in external mode. When in external mode, Series AD9 units shall accept 4-20 mA input signal or external pulse signal for control of pump speed. The pump shall be capable to support external connection requirements for remote start/stop or pulse divide/multiply options or output for a power supply for remote powered devices. The pump shall be capable to support external connection capabilities for a digi-pulse or flow meter input or flow meter sensor. The pump shall be capable to support external connection for a remote internal/external input or 4-20 mA output or pacing output or alarm output. The pump shall be equipped with an on/off button and a dual low level float switch input. When the dual low level sensor registers empty, the low level indicator light shall turn yellow when a low level is registered and red when an empty level is registered. The pump shall turn off when it registers an empty level. The pump shall be equipped with a universal voltage supply capability.

    DRIVEThe pump drive shall be totally enclosed with no exposed moving parts. Electronic pulser shall be supplied with quick connect terminals at least .110” wide (2.79 mm). Electronics shall be housed in a chemical resistant enclosure for maximum protection against chemical spillage. Electrical power consumption shall not exceed 25 watts per hour under full speed and maximum pressure conditions. Pump weight shall not exceed 10 lbs (4.75 kg).

    PRESSURE RELIEFThe LMI 4-Function Valve installed with a FastPrimeTM or AutoPrimeTM Liquid End is recommended to provide automatic pressure relief.

    MATERIALChemical metering pump housing shall be of chemically resistant glass fiber reinforced thermoplastic. All exposed fasteners shall be stainless steel. Chemical metering pump valves shall be ball type, with ceramic balls4. Valves shall be serviceable by replacing the cartridge valve assembly. Pump head shall be of transparent acrylic5 material capable of resisting the pumped chemical. Fittings and connections at pump head shall be PVC6.

    CHECK VALVES AND TUBINGA total of 16 ft (4.8 m) of polyethylene tubing7 shall be provided per pump complete with compression connections. A foot valve with integral one piece strainer shall be provided for the suction line, and an injection check/back pressure valve with ½” NPT male connection for the injection point.

  • © 2010, 2011 Milton Roy Company–All Rights ReservedSpecifications Subject to Change

    FASTPRIME, AUTOPRIME AND ROYTRONIC EXCEL are trademarks of Milton Roy Company

    NOTE: ALL DIMENSIONS ARE IN INCHES [MM]. DIMENSIONS SHOWN ARE FOR LARGEST LIQUID END. DIMENSIONS WILL VARY DEPENDING ON LIQUID END SELECTED.

    4.06103.2

    4.60116.8

    11.23

    285.1

    FASTPRIME LIQUID ENDS

    12.65

    321.3

    11.50292.1

    7.76

    197

    7.68195.1

    7.98202.6

    1.2231

    3.1279.2

    4.06103.2

    8.41

    213.6

    4.30109.3

    AUTOPRIME LIQUID ENDS

    12.65

    321.3

    11.50292.1

    7.76

    197

    7.98202.6

    7.68195.1

    3.7094

    1.2231

    6.27159.1

    4.24107.7

    2.1253.8

    0.348.6

    3.52

    89.5

    6.50165.1

    A0.2

    05.1

    0.4511.4

    VIEW A

    MOUNTING INFORMATION