12
Royce Total Suspended Solids Systems

Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

Embed Size (px)

Citation preview

Page 1: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

Royce Total SuspendedSolids Systems

Page 2: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

Portable and Continuous TSS Systems

• Two complete analyzers in one package (TSS & Interface Level)

• Microprocessorbased

• Automaticranging

• Simple,insitucalibration

• Electronicself-diagnostics

• Ninevoltbatterywithautomaticshutoff

• Waterproof,ruggedhousing

• Automaticranging

• Simpletouseinsitucalibration

• Menudriventexthelpscreens

• Electronicselfdiagnostics

• Digitalcommunicationswithisolationandsurgeprotection

• Isolatedcurrentorvoltageoutputs

• Upto2set-pointrelaysperchannel

• Userselectablecalibrationcurves

• Backlitdisplay(7110/7120)

• Menudriventexthelpscreens

• Phasedarraysourceforautomaticcolorcompensation (Model73B/73PSensor)

• Automaticambientlightcompensationonallsensors

• NEMA4X(IP65)enclosure

MODEL 711 PORTABLE MLSS/ILA SYSTEM

MODEL 7110/7120 SINGLE/DUAL CHANNEL ANALYZER

MODEL 7011A SINGLE CHANNEL ANALYZER

2

Model711PortableMLSS/ILASystem

FEATURES

FEATURES

Model7110/7120Series Continuous System

Page 3: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

TheSeries7110/7120WaterProcessAnalyzerisasingleordualchannelsolidsmonitoringsystemthatoffersthelatestindigital communicationwhileutilizingoneortwoRoyceTSSsensors.Sensorsdonothavetobethesamemodel.TheSeries8000WaterProcessAnalyzercanbemadeuptoa4-channelsystemthatwillincorporateuptoanytwoTSSsensorsplustwoDissolvedoxygensensors.Whileitcanbepurchasedasadualchannel,3-channelor4-channelsystem,thesensorcombinationsarealmostunlimited.

TheModel7011ATotalSuspendedSolids(TSS)AnalyzerisatriedandtrueperformerthathasanchoredtheRoycelineofsolidsanalyzersforyears.ThemostwidelyusedTSSanalyzerintheindustry,theModel7011AistheprimarysinglechannelofferingintheRoycelineofanalyzers.

Instrument Ambient Conditions:Temperature:-10to50ºCHumidity:0to100%

Input Power:80–260VAC,60/50Hzor12VDC

Outputs:Fourisolated4–20mAperanalyzer600ohmsmaximumFourRelayswithprogrammablehysteresis10Aresistive@250VACRS-485&Modbus(Standard)ProfibusDP(Optional)

Readout Device:Harshenvironment,fourline,20CharacterbacklitLCDdigitaldisplay

Calibration:Push-buttonforIn-SitucalibrationtoaknownvalueforTSS

Enclosure:NEMA4X(IP65)Fiberglass

Weight:5.5Lbs(2.5kgms)

Range:0–10,000and0–80,000mg/L(SensorDependent)

Standard Outputs:4–20mAor0–1VDC(Isolated)RS-485serialport(isolatedandsurgeprotected)

Standard Setpoints:Two programmable setpoint relaysAllrelaysareformCrated250VAC,7Ampsresistive

Readout Device:Harshenvironment,2.2”x1.5”LCDdigitaldisplay

Input Power:Switchselectable115/230VAC,60/50Hz

Enclosure:NEMA4X(IP65)Fiberglass

Instrument Ambient Conditions:Temperature:-10to50ºCWithHeater:-40to50ºCHumidity:0to100%

Analyzer Options:NEMA4XenclosurewithquickdisconnectforsensorRearRailmountingkitJB-93junctionboxwithquickdisconnectforsensor

Weight:5.5Lbs(2.5kgms)

3

ContinuousMonitoringandControlSolidsAnalyzers

SPECIFICATIONS

Model7110/7120Analyzers

SPECIFICATIONS

Page 4: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

18.5REQUIRED FORMAINTENANCE

DOOR SWING OUT

13.5REQUIRED FORMAINTENANCE

U–BOLT FOR2” HAND RAIL(2 SUPPLIED)

14.0

12.0

TECHNOLOGIES

MENU ENTER

WATER PROCESS ANALYZER

WATER PROCESS ANALYZER

1/4–20 UNCINSERT, 4 PLCS0.31 CLEARANCE DRILL

(4) 1/4–20 X 0.500 LONG PAN HEAD SCREWS SUPPLIED WITH MOUNTING KIT

BACK VIEW

FRONT VIEW

9.37

8.30

10.50TECHNOLOGIES

MENU ENTER

10–24X1.00 LG S.S.PAN HEAD SCREW

SIDE VIEW

18.5

13.00

NOTES:1. CONSTRUCTION POLYCARBONATE NEMA 4X ENCLOSURE2. APPROXIMATE WEIGHT: 6 LBS.

WATER PROCESS ANALYZER

10.50

4

14.0

12.0

TECHNOLOGIES MODEL 7011A

SUSPENDED SOLIDS ANALYZER

18.5REQUIRED FORMAINTENANCE

DOOR SWING OUT

13.5REQUIRED

FORMAINTENANCE

U–BOLT FOR2” HAND RAIL(2 SUPPLIED)

TECHNOLOGIES MODEL 7011A

SUSPENDED SOLIDS ANALYZER

FRONT VIEW

8.45

7.3210–24X1.00 LG S.S.PAN HEAD SCREW

MODEL 7011A ANALYZER DIMENSIONS, RAIL KIT OUTLINE AND MOUNTING

SERIES 7110/7120 ANALYZERS

Page 5: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

Type:SingleGapOptical

Range:10–1500mg/l

Resolution:1mg/l

Accuracy:±5%ofreadingor±5mg/l,whicheverisgreater

Repeatability:±1%ofreadingor±2mg/l, whicheverisgreater

Operating Limits:Temperature:0–50ºCPressure:0–50PSIG

Size:4.5inchessquare

Weight:5.5Lbs(2.5kgms)

Construction:Chemicallyresistantpolyurethane opticsinpolyurethanehousing

TheModel72Aisforlowrangescommonlyexperiencedineffluentstreams(10–1500mg/l).Itincorporatesauniqueautomaticambient lightcompensatingtechnologythatallowsforcleanwatermonitoringinsitu,withoutrequiringsampleintakelinesforreflectionchambers.Automaticselfcleaningisavailable.

• Thesensorcableisa5conductorshielded22AWG.Itis availablein25and50footlengthsasstandard.

• Aconnectorforquickdisconnecttothemonitorisprovided asstandardonthesensorandanalyzer.TheconnectoronthesensorisrequiredwhenusedwiththeJB-93junctionbox.

• AllRoycesuspendedsolidssensorsareequippedforanair orwaterjetcleaning.

FLOW DIRECTION

1-1/2” PVC PIPE(CUSTOMER SUPPLIED)

PROBE PIPE MOUNTING BRACKET KIT

ROYCE COMPRESSOR OR VALVE FOR HOUSE

AIR/WATER

1/4” AIR TUBING @ 60 PSI

(TO COMPRESSOR ASSEMBLY OR SOLENOID VALVE)

CLEANING JET

1 1/2” PVC PIPE(CUSTOMER SUPPLIED)1/4” AIR TUBING

@60 PSI

1/4” COMPRESSIONFITTING

(ROYCE SUPPLIED)

CABLE TO ANALYZEROR JUNCTION BOX

FLOWDIRECTION

4.75

3.87

Range: 10–1500mg/l, Construction: MoldedEpoxy/PVC

Limits: Temp.0–50ºCPressure:0–20PSIG

Optical:3”FlangedSpoolMounted;AirorWaterJetSelf-Cleaning

5

SPECIFICATIONS SENSOR MOUNTING

SPECIFICATIONSTheModel72Pisalowrange,flowthroughversionofthepopularModel72A.CommonlyusedinoutfallplumbingofpackagedWWTP’s,portablepotablewatersystems,backwashfilterlinesandotherprocesswaterlinesforthemeasurementoflowlevelsuspendedsolids.

Model72PFlowThroughLowRangeTSSSensor

Model72ALowRangeTSSSensor

Page 6: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

Type: SingleGap,Optical;selfcleaning.Model73Bhasphased

arrayemitter/receptorcombinationforautomaticcolor compensation

Range: 300–3,000upto300–30,000mg/l 0–3%

Accuracy: ±5%ofreadingor±100mg/l,whicheverisgreater

Repeatability: ±1%ofreadingor±20mg/l,whicheverisgreater

Operating Limits: Temperature:0–50ºC Pressure:0–50PSIG

Size: 2.5”Dx3.3”L

Weight: 12ounces(.34kgms)

Construction: Chemicallyresistantpolyurethaneoptics Moldedpolymerhousing

• Thesensorcableisa8conductorshielded22AWG.Itisavailablein25and50footlengthsasstandard.

• Aconnectorforquickdisconnecttothemonitorispro-

vided onthesensorandanalyzer.Theconnectoronthesensoris requiredwhenusedwiththeJB-93junctionbox.

• AllRoycesuspendedsolidssensorsareequippedforanair orwaterjetcleaning.

TheModel73BsubmersiblesensorisdesignedformixedliquorsuspendedsolidsorMLSStypicallyfoundinaerationbasins.Thissensorusesphasedarraycolorcompensationtocorrelatelightabsorptionwithsuspendedsolids.

1 1/2” PVC PIPE(CUSTOMER SUPPLIED)

ROYCE COMPRESSOROR VALVE FOR

HOUSE AIR/WATER

• Thesensorcableisa5conductorshielded22AWG.Itis availablein25and50footlengthsasstandard.

• Aconnectorforquickdisconnecttothemonitorisprovided onthesensorandanalyzer.Theconnectoronthesensoris requiredwhenusedwiththeJB-93junctionbox.

• AllRoycesuspendedsolidssensorsareequippedforanair orwaterjetcleaning.

SENSORCABLE

1/4” OLD TUBINGFOR JET CLEAN

3”–150# ANSI FLANGE(SCH. 80 PVC)

+

7.6+.5–

+ +

+

+

2.90

6.00

7.50

7.50

6

MODEL 72P SENSOR MOUNTING

MODEL 73B SUBMERSIBLE MLSS SENSOR

SPECIFICATIONS

Page 7: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

TheModel73Pin-lineMLSSsensoriscommonforusewithin-linemixedliquorapplications,septicwasteinfluentapplications,andpackagedWWTPRAS,WASMLSSandinfluentlines.

Mid-Range:ColorCompensated;Pipeinsertion;AirorWaterJetSelfCleaning

Range: 300–3,000upto300–30,000mg/l,0–3%

Construction: MoldedEpoxy/PVCLimits:Temp.0–50ºCPressure:0–20PSIG

• Thesensorcableisa8conductorshielded22AWG.Itisavailablein25and50footlengthsasstandard.

• Aconnectorforquickdisconnecttothemonitoris

providedonthesensorandanalyzer.Theconnectoron thesensorisrequiredwhenusedwiththeJB-93junction box.

• AllRoycesuspendedsolidssensorsareequippedforanair orwaterjetcleaning.

1/4” TO 1/3”DRAIN HOLE

4.9 (73B)4.7 (75A)

1.85

2.10

2.00

1 1/2” (NPT) THREADS OR MALE ADAPTER

PVC COUPLING

1 1/2” FNPT

1/4” COMPRESSION FITTINGFOR JET CLEAN TUBING(ROYCE SUPPLIED)

FLOWDIRECTION

RUBBER SEAL

SEAL ASSEMBLYROYCE SUPPLIED

SAFETY CABLETOP VIEW

FLO

W

INSERTION STOP

NUT

FLOWDIRECTION

RUBBER SEAL

SEAL ASSEMBLYROYCE SUPPLIED

SAFETY CABLETOP VIEW

FLO

W

INSERTION STOP

NUT

7

MODELS 73P SENSOR MOUNTING

Model73PFlowThroughMLSSSensors

Page 8: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

Type:SingleGap,Optical;selfcleaningwaterjet

74A Range:800–8,000upto800–80,000mg/l,0-8%

76A Range:300–3,000upto300–30,000mg/l,0-3%

Accuracy:74A:±5%ofreadingor±150mg/l,whicheverisgreater76A:±5%ofreadingor±100mg/l,whicheverisgreater

Repeatability:74A:±1%ofreadingor±30mg/l,whicheverisgreater76A:±1%ofreadingor±30mg/l,whicheverisgreater

Operating Limits:Temperature:0–50ºCPressure:0–50PSIG

Size:2”insertionDx19”L2”NPTmalepipeinsertionnipple

Weight:16pounds(7kgms)

Construction:316SSinsertionshaftandlensholdersChemicallyresistantpolyurethaneoptics

• Thesensorcableisa8conductorshielded22AWG.Itisavailablein25and50footlengthsasstandard.

• Aconnectorforquickdisconnecttothemonitoris

provided onthesensorandanalyzer.TheconnectoronthesensorisrequiredwhenusedwiththeJB-93junctionbox.

• CleaningconnectionsuppliedbyRoycetohousewateris

3/8”compressionfitting.

• Cleaningpressuremustbe20PSIGgreaterthanline

pressure.

• AllRoycesuspendedsolidssensorsareequippedforanair

or waterjetcleaning

TheModel74Aand76Ain-linesensorsareusedinWAS(WasteActivatedSludge)andRAS(ReturnActivatedSludge)lineapplications.ThesesensorsofferautomaticwaterJetcleaningofthesensoropticsbyhousesuppliedwater.

FLO

W

FLO

W

2” NPT. X 3” LONG3/8” S.S. NIPPLE

MAXIMUM DISTANCE TOMIDDLE OF PIPE

TO INSURE IMMERSIONOF SENSOR = 5.78

14.5

CONNECT 3/8” TUBINGFOR CLEANING FLUID

3/8” COMPRESSION (ROYCE SUPPLIED)

CHECK VALVE(ROYCE SUPPLIED)

BALL VALVE HANDLEIN OPEN POSITION

(CLOSED = 9.0” SWING)

8.0

ADDITIONAL CLEARANCE SPACEREQUIRED FOR SENSORINSTALLATION AND REMOVAL

LENGTH OF PROTRUDING PORTION WITH SENSOR INSTALLED17.63

12.6LENGTH OF PROTRUDING PORTION

WITH SENSOR REMOVED

1.4

SENSORHEAD

8

MODELS 74A & 76A OUTLINE AND MOUNTING

Model74Aand76AHighDensityPipeInsertionSensors

SPECIFICATIONS

Page 9: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

Construction:PolystyreneNEMA4X(IP65)

Options:RailMountingKit

Weight:JB-93:2LbsWithrailmountkit:.5Lbs

8.5

4.9

8.5 4.9

U–BOLT FOR2” HAND RAIL(2 SUPPLIED)

MOUNTING ON EITHER HORIZONTAL OR VERTICAL RAIL

TECHNOLOGIES

9

JB-93JunctionBox

RAIL KIT OUTLINE AND MOUNTING

Page 10: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

Channels: One,TwoorFour

Compatibility: AllRoyceAnalyzers

Compressor Ambient Conditions: 0to70ºC -10to70ºCwithoptionalheater

Input Power: 115VAC,50–60Hzor 230VAC,50–60Hz +10%to-15%

Outputs: Uptofour,1/4”pushseal bulkheadconnections

Enclosure Protection: Ventportfitted

Enclosure: NEMA4X(IP65)

Enclosure Dimensions: JC-1–14”Wx12”Hx6”D JC-2or4–17.5”Wx16”Hx10.5”D DoorHingesUp

Weight: JC-1–26lbs,11.8kgms JC-2–37lbs,16.8kgms JC-4–40lbs,18.2kgms

ThesensoropticsareJetCleanedbyanairorwaterblastacrosstheopticsonatimedbasiswhichiscontrolledbytheparentinstrument.Cleaningfrequencyanddurationofthejetblastare programmed by theusertomeetthedemandoftheapplicationwhereoptical surfaces are soiled by organic or biologicalfouling.

AllRoycesuspendedsolidssensorsareequippedforJetCleaningofthesensoropticsbyhousesuppliedairorwaterusingasolenoid.Aminimumof30PSIGandamaximumof60PSIGisrequiredforhouseairorwater.

TheRoyceCompressorAssemblyiscompatiblewith submersibleMLSSsensorsandisavailableasanoption.

TheModel74Aand76Ain-linesensorscannotusetheRoyceCompressorAssembly.

AnindustrialgradehighoutputcompressorisusedonallRoyceJC Seriescompressorcleaningsystems.Byusingthesamecompressorformultipleinstrumentsensors,thecostpersensoris drastically reduced.AnyRoyceanalyzercanoperateanyJCSeriescompressor. Infact,amulti-channelJC-2orJC-4canbeused on any combination ofRoycedissolvedoxygenortotalsuspended solidssensorsatonetime.

TheModelsJC1,2,and4areallavailableineither115VACor230VACversions,andallelectricalpartsareCEcertified.

MODEL JC-1 COMPRESSOR – SINGLE CHANNEL MODEL JC-4 COMPRESSOR – FOUR CHANNEL

COMPRESSOR OUTPUT 1/4” TUBING

BULKHEADFITTING

BOTH POSITIONS SHOWN, ONLY ONE U-BOLT REQUIRED ON VERTICAL RAIL

U-BOLT FOR2” DIA HANDRAILMINIMUM OF 3 PLACES(3 SUPPLIED)

1/2” NPT CLEARANCEHOLE WITH PLUG,2 PLACES

MOUNT PANEL WITH 2 U-BOLTS ON HORIZONTAL RAIL,

1 U-BOLT ON VERTICAL RAIL

TECHNOLOGIES

10

RoyceJCSeriesCompressorAssemblyforSubmersibleMLSSSensorJetCleanforOptics

SPECIFICATIONS

Page 11: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

TheRoyceModel711PortableSuspendedSolids/InterfaceLevelAnalyzerisarugged,waterproofinstrumentdesignedfortherigors ofremotesampling.Themeterprovidesreliableoperationin wastetreatmentplants,rivers,lakesandotheraqueoussystems.Themeterwillreadineithergramsperliterwheninthesuspendedsolidsmodeorrelativedensitypercentagewhileintheinterfacelevelmodeofoperation.

TheModel711storesthecalibrationvaluesforsuspendedsolidsand interface level in two separate nonvolatile memory locations allowingtheusertoswitchbetweenoperationalmodeswithouthavingtorecalibrate.Theneteffectistwoanalyzersinone.

Duetothefullutilizationofthemicroprocessor,calibrationvaluesarestoredsothatrecalibrationisnotrequiredonadailybasis.Ifthesensoriscleanedafteruse,monthlycalibrationisusuallymorethansufficientforproperoperationineithermodeofcalibration.

TheModel711analyzerutilizestheModel71mediumrangesensor.TheModel71isarugged,reliablesensingelementthathaspolymeropticalgradelenses.Itwasdesignedspecifically tomeettherigorousdemandsthatarearequirementforaportablesensor.

• Two analyzers in one package: SwitchfromSolidsmeasurementtoInterfacelevelwithout losingcalibration.

• Automaticranging: Goescompletelyovertheoperatingrangeoftheanalyzer withmanualadjustment.

• Simple,insitucalibration.

Range:.01–10gramsperliter(10to10,000mg/l)

Readout Device:Harshenvironment,1/2”LCDdigitaldisplay

Input Power:Standard9Vbattery

Enclosure:Waterproof

Size:7”Lx3.2”Wx1.5”D

Weight:1.5pounds(.68kgms)

Type:SingleGap,Optical

Accuracy: ±5%ofreadingor±100mg/l,whicheverisgreater

Repeatability:±1%ofreadingor±20mg/l,whicheverisgreater

Range:.01–10g/l

Operating Limits:Temperature,0–65ºCPressure,0º50PSIG

Size:4”Lx2”D

Weight:1pound(.45kgms)

Construction:PolyurethanebodyOpticalgradepolymerlenses

• Model711ruggedSuspendedSolidsanalyzer

• Model71ruggedSSsensorwith8metersor25feetof

cable andwaterproof,militaryconnector.

• Cableisscaledinonefootincrements.

• Velcro“gripstrap”whichcanconverttoahandybelt

holder.

• 9Vbattery.

• Detailedinstructionmanual.

11

Model711PortableSuspendedSolidsandInterfaceLevelAnalyzer

SPECIFICATIONS

SUPPLIED STANDARD WITH MODEL 711 SYSTEMSPECIFIC FEATURES

Page 12: Royce Total Suspended Solids Systems · The Series 7110/7120 Water Process Analyzer is a single or dual channel solids monitoring system that offers the latest in digital communication

151GrahamRoadPOBox9010CollegeStation,Texas77842-9010

(979)690-1711(800)653-1711USA/CanadaFAX(979)690-0440

www.roycetechnologies.comE-mail:[email protected]

Publication 37620812

MEASUREMENT TECHNOLOGIES BY ROYCE

Dissolved Oxygen Monitoring and Control• SingleandMulti-channelAnalyzers

• BioreactorandLagoonSystems

Total Suspended Solids Monitoring and Control• PortableAnalyzers

• SingleandMulti-channelAnalyzers

• Solidsdensity

Interface Level analyzers• Primary,SecondaryandThickenerAnalyzers

Royce,aXylembrand,provideshighqualitymonitoringandcontrol instrumentation and sensors specifically designed for municipalandindustrialwastewatertreatmentapplications.Recognizedthroughoutthewastewatertreatmentindustryasexpertsinthebiologicalwastewatertreatmentprocess.